Comments
Honestly ... unsure ... The OBIS specs is not defining such IDs ... Whats the meaning of them? Seems like the manufactorer invested them himself :-( Can I please get a debug lkog to see the message returned? Is this coming anytime data coming in or just sometimes? |
Is this coming anytime data coming in. I contacted the manufacturer for this Info and for now I'm waiting for a feedback.
|
Ok, if it comes always then it seems wrong in response ... but as said formally not defined for OBIS :-( Lets see what they answer |
This issue has been automatically marked as stale because it has not had recent activity. It will be closed if no further activity occurs within the next 7 days. Please check if the issue is still relevant in the most current version of the adapter and tell us. Also check that all relevant details, logs and reproduction steps are included and update them if needed. Thank you for your contributions. |
@joerghildering Aand, any answer from manifacturer? |
@Apollon77 Unfortunately not |
This issue has been automatically marked as stale because it has not had recent activity. It will be closed if no further activity occurs within the next 7 days. Please check if the issue is still relevant in the most current version of the adapter and tell us. Also check that all relevant details, logs and reproduction steps are included and update them if needed. Thank you for your contributions. |
This issue has been automatically marked as stale because it has not had recent activity. It will be closed if no further activity occurs within the next 7 days. Please check if the issue is still relevant in the most current version of the adapter and tell us. Also check that all relevant details, logs and reproduction steps are included and update them if needed. Thank you for your contributions. |
I´m using the ELSTER 1440 and the smartmeter adapter in iobroker an got this in the protocol:
Error while parsing D0 content: ignore complete part Error: Invalid Obis String 1-1:30D
Error while parsing D0 content: ignore complete part Error: Invalid Obis String 1-1:7D
Error while parsing D0 content: ignore complete part Error: Invalid Obis String 1-1:1D
Could you please add this strings?
The text was updated successfully, but these errors were encountered: