You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Hi,
I am from CSIRT-MU, and I have a couple of questions about ipfixcol2.
When using a PEN biflow mode, the reverse ipfix attributes are in a format XXXXX@reverse:YYYYY@reverse but when I use a SPLIT biflow mode then the reverse attributes are in another form XXXXXX:YYYYY@reverse (missing @reverse in the first part).
We think that it is an inconsistency.
I tried to investigate how does it internally works and if I get it right then If I use PEN biflow mode then internally in code there are two separated PEN configurations for each direction, but in SPLIT mode there is only one PEN conf, so the PEN name is not different for the reverse direction.
Would it be possible to unify this behaviour across different biflow modes somehow?
Also, would it be possible to add the possibility to adjust the form of a reverse suffix(@reverse)?
The text was updated successfully, but these errors were encountered:
yes, you are right that the naming is slightly inconsistent between these two modes. It was probably necessary to internally distinguish two PEN scopes in biflow mode. Nevertheless, I will try to look whether its possible to solve it soon.
Regarding the second question, yes, it would be possible, for example, by adding additional parameter to the scope definition, which will redefine the default value @reverse. However, is it really necessary to redefine it? Why would you like to change it?
Hi,
I am from CSIRT-MU, and I have a couple of questions about ipfixcol2.
When using a PEN biflow mode, the reverse ipfix attributes are in a format
XXXXX@reverse:YYYYY@reverse
but when I use a SPLIT biflow mode then the reverse attributes are in another formXXXXXX:YYYYY@reverse
(missing@reverse
in the first part).We think that it is an inconsistency.
I tried to investigate how does it internally works and if I get it right then If I use PEN biflow mode then internally in code there are two separated PEN configurations for each direction, but in SPLIT mode there is only one PEN conf, so the PEN name is not different for the reverse direction.
Would it be possible to unify this behaviour across different biflow modes somehow?
Also, would it be possible to add the possibility to adjust the form of a reverse suffix(
@reverse
)?The text was updated successfully, but these errors were encountered: