Prometheus Monitoring Safety Device (PromMSD)

tl;dr: The watcher of the watchers for Prometheus and Alertmanager.

What?

Just like train drivers have a dead man's handle (or dead man's switch, in US English) this is the same concept for Prometheus and Alertmanager.

One way to think of this is it inverts alerting: If an alert stops being received this will generate and deliver an alert to alertmanager instances. A key point to note is this does not have persistent state -- it needs to receive alerts first, then it will alert for the lack of alerts later.

Why the name?

A "dead man's" device is more correctly called a "Driver Safety Device", this is your safety check for your monitoring, so it's monitoring safety rather than driver safety.

Alternatives

prommsd may not be the best approach for everyone. Here are some alternatives:

  • Monitor your Prometheus instance from another one
  • Use cloud services, like Dead Man's Snitch (see here for one way to configure it).

Why write this then?

In more complex setups this can be a shared instance, that doesn't require every Prometheus have an exact pair, or additional configuration elsewhere. Additionally it can deliver to different alertmanager instances than the Prometheus instance.

It also provides some level of round-trip testing, i.e. a probe for your Prometheus and Alertmanager together, and once you have prommsd running within your infrastructure, it can easily be enabled with a standard rule on your Prometheus instances, rather than needing configuration elsewhere.

Setup

Alerting rule

Configure an alerting rule to always alert if your instance is healthy. The simplest is just expr: 1. We recommend a slightly more advanced rule (see below). While checking the "up" status of yourself may seen redundant, it provides a basic end-to-end sanity check of your Prometheus instance consistency and potentially your service discovery.

groups:
  - name: heartbeat
    rules:
      # This alert should always fire
      - alert: ExpectedAlertHeartBeat
        expr: sum(up{job="prometheus"}) by (job, namespace, cluster) > 0
        # Extra safety: if a Prometheus is restarting frequently don't fire straight
        # away. (Ideally you also have something detecting if jobs are restarting, maybe
        # via Kubernetes metrics, but this provides some extra confidence.)
        for: 30s
        labels:
          severity: heartbeat
        annotations:
          summary: |
            Expected alert to test {{ $labels.job }} presence
          # These are parameters, see below...
          msd_identifiers: job namespace cluster
          msd_alertname: NoAlertConnectivity
          msd_override_labels: severity=critical
          msd_activation: 10m
          msd_alertmanagers: |
            http://local.alertmanager
            http://alertmanager1.fully.qualified:xxx
            http://alertmanager2.fully.qualified:xxx
          msda_summary: Alert connectivity from {{ $labels.namespace }} in {{ $labels.cluster }} is degraded.
          msda_description: Alerts aside from this alert may not be delivered. Check Prometheus and Alertmanager health.

Parameters:

  • msd_identifiers: Labels to use to uniquely identify an alert. (Often "job" would be enough, but because the monitoring safety device is a shared instance you may also need to include namespace, or other variables). Space separated.
  • msd_alertname: Alert name to use for the triggered alert.
  • msd_override_labels: All the labels from the alert will be copied, but override these (key=value string, with space separator).
  • msd_activation: Duration after no alert is seen to trigger an alert. (Can use Go durations, e.g. "60s", "10m".)
  • msd_alertmanagers: Space separated list of alertmanager URLs. Recommended to have your local one here and at least one remote one. On Kubernetes you may wish to repeat the same instance as both the in-cluster and out-of-cluster address, assuming you can reach the ingress, this can allow you to share the configuration between clusters without changes. You can also specify webhook+http://host/... to directly target a alertmanager compatible webhook.
  • msda_NAME: NAME will become an annotation on the generated alert.

The alert that will be raised once msd_activation is reached will have all the labels from the original alert (except "alertname" and "severity") as labels, in addition to any labels set in msd_override_labels overriding those labels.

Annotations will be added from parameters called msda_*, e.g. msda_summary becomes summary.

Sending to a webhook

The recommended configuration is to route the alerts this generates via an alertmanager, but in some cases it is useful to send straight to a webhook component. Specifying webhook+http://webhook/alert in msd_alertmanagers will allow you to do this.

It is expected that prommsd is connected to a system that understands incidents, as it will repeat notifications frequently.

Sending to Slack

In addition to webhooks, it is possible to send a message to Slack. This is designed to work with the "Incoming WebHooks" Slack app.

To use, ensure you have the "Incoming WebHooks" app added on your Slack workspace. Then add the integration to a channel, which will give you a URL; add that URL to your msd_alertmanagers annotation prefixed with slack+. This will look something like: slack+https://hooks.slack.com/AN-ID/ANOTHER-ID...

Alert routing

In the alertmanager configuration, set an alert route that routes severity=heartbeat to a receiver called prommsd:

route:
  # ...

  routes:
      - match:
          severity: heartbeat
        receiver: prommsd
        # Always set group_interval to a very short non-zero
        # duration: prommsd does its own grouping and alertmanager
        # requires non-zero.
        group_interval: 1s
        repeat_interval: 1m

An entry in the receivers section for prommsd:

receivers:
  - name: prommsd
    webhook_configs:
      - send_resolved: false
        url: http://localhost:9799/alert

It is possible to use continue: true and deliver to additional prommsd instances running elsewhere. In general we don't recommend this be instances far away from this, as that is replacing connectivity monitoring -- use a blackbox probe instead. In particular this could be very noisy if there is a connectivity issue whereas a Prometheus alert can be grouped and more easily silenced.

Monitoring of the monitor

A rule to verify prommsd is running. We recommend to only run on one Prometheus instance, e.g. in the Prometheus in Kubernetes namespace that runs this, if there's a Prometheus instance per namespace:

groups:
  - name: prommsd
    rules:
      - alert: JobDown
        expr: up{job="prommsd"} == 0 or absent(up{job="prommsd"})
        for: 5m
        labels:
          severity: critical
        annotations:
           summary: "Expected {{ $labels.job }} to be running to monitor the monitor"

Running

go build ./cmd/prommsd

./prommsd

We hope to provide a Docker image soon.

Checking

There is a status interface available on the HTTP port. In addition Go's x/net/trace is available.

Metrics

Standard Go metrics are provided.

Overall metrics:

  • prommsd_build_info has build information.
  • prommsd_alertcheck_monitored_instances a gauge with the currently monitored number of instances.

Alert reception:

  • prommsd_alerthook_received_total heartbeat alerts received on "/alert"
  • prommsd_alerthook_errors_total errors handling the heartbeats

Alert sending:

  • prommsd_alertmanager_sent_total alerts sent to alertmanager (firing and resolved)
  • prommsd_alertmanager_errors_total errors sending to alertmanager (with a type label for the kind of failure)

These metrics mostly exist for debugging issues, for prommsd itself we recommend simply monitoring that the prommsd job is up via Prometheus. You should also monitor your alertmanager is sending alerts separately.

Limitations

This approach aims to be very simple and all state is stored in memory, this means a restart of the service will lose the pending alerts. This may sound bad but actually in many cases isn't a problem -- this is good at noticing a Prometheus or Alertmanager instance having problems. (Persisting some state between restarts may be something we consider as it could make sense in some environments, but in general we believe in those cases a more resilient approach is to run multiple instances of this instead -- let us know your use cases). You should consider carefully how this fits your deployment -- if using Kubernetes a reasonable approach is to run an instance of this inside each Kubernetes cluster, but (via msd_alertmanagers) able to send alerts to Alertmanagers outside the cluster. Combined with a federated Prometheus setup (or blackbox probes) that checks cross cluster connectivity this covers Prometheus configuration problems while the cluster connectivity is handled by rules inside your Prometheus.

Testing

Silence the heartbeat alert (alertname=ExpectedAlertHeartBeat if you're using the configuration from here).

You can then watch the status interface and see that the timer for when the alert will fire starts counting down, with the alert firing just after the countdown finishes.

Maintenance

Silence the paging alert (alertname=NoAlertConnectivity if msd_alertname is set as above).

If you're removing an instance, there is a delete button on the interface. Make sure the alert is deleted from Prometheus so that it doesn't get recreated on prommsd, then delete it. Currently there is no authorization enforced -- because the alert is regularly repeated, deleting has minimal impact, unless an outage occurs.

Development

Contributions are welcome.

The only thing to keep in mind is this aims to have minimal dependencies on Prometheus and components, in order to provide low dependency alerting about monitoring system failure. Consider carefully if you add another dependency to this -- could instead it be done with a Prometheus rule or another external service?

Licence

Copyright 2021 G-Research

Licensed under the Apache License, Version 2.0 (the "License"); you may not use these files except in compliance with the License. You may obtain a copy of the License at: http://www.apache.org/licenses/LICENSE-2.0

Unless required by applicable law or agreed to in writing, software distributed under the License is distributed on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License for the specific language governing permissions and limitations under the License.