Notifications
You must be signed in to change notification settings - Fork 7
/
Copy pathkessel.yaml
141 lines (128 loc) · 3.82 KB
/
kessel.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Kesseltemperatur"
id: ${name}_Kesseltemperatur
register_type: read
address: 0
unit_of_measurement: "°C"
device_class: "temperature"
state_class: "measurement"
value_type: U_WORD
filters:
- multiply: 0.5
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Abgastemperatur"
id: ${name}_Abgastemperatur
register_type: read
address: 1
unit_of_measurement: "°C"
device_class: "temperature"
state_class: "measurement"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Verbleibende Heizstunden bis zur Asche entleeren Warnung"
id: ${name}_Verbleibende_Heizstunden_bis_zur_Asche_entleeren_Warnung
register_type: read
address: 86
unit_of_measurement: "h"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Saugzug - Ansteuerung"
id: ${name}_Saugzug_Ansteuerung
register_type: read
address: 13
unit_of_measurement: "%"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Saugzugdrehzahl"
id: ${name}_Saugzugdrehzahl
register_type: read
address: 6
unit_of_measurement: "rpm"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Sauerstoffregler"
id: ${name}_Sauerstoffregler
register_type: read
address: 16
unit_of_measurement: "%"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Restsauerstoffgehalt"
id: ${name}_Restsauerstoffgehalt
register_type: read
address: 3
unit_of_measurement: "%"
accuracy_decimals: 1
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Rücklauffühler"
id: ${name}_Ruecklauffuehler
register_type: read
address: 9
unit_of_measurement: "°C"
device_class: "temperature"
state_class: "measurement"
value_type: U_WORD
filters:
- multiply: 0.5
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Primärluft"
id: ${name}_Primaerluft
register_type: read
address: 11
unit_of_measurement: "%"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Sekundärluft"
id: ${name}_Sekundaerluft
register_type: read
address: 12
unit_of_measurement: "%"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Betriebsstunden"
id: ${name}_Betriebsstunden
register_type: read
address: 20
unit_of_measurement: "h"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Stunden seit letzter Wartung"
id: ${name}_Stunden_seit_letzter_Wartung
register_type: read
address: 55
unit_of_measurement: "h"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Betriebsstunden in der Feuererhaltung"
id: ${name}_Betriebsstunden_in_der_Feuererhaltung
register_type: read
address: 24
unit_of_measurement: "h"
value_type: U_WORD
binary_sensor:
- platform: template
name: "${name} Kesselzustand Heizen"
id: ${name}_Kesselzustand_Heizen
lambda: |-
if (id(${name}_Kesselzustand).state == "Heizen") {
return true;
} else {
return false;
}