Notifications
You must be signed in to change notification settings - Fork 34
/
Copy pathintan_rhx_release_notes.txt
126 lines (113 loc) · 8.85 KB
/
intan_rhx_release_notes.txt
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
Intan RHX release notes
-----------------------
* Version 3.0, 11 February 2021
- First release; started with v3.0 to avoid confusion with older Intan software.
* Version 3.0.1, 12 February 2021
- Fixed bug that caused crash during electrode impedance measurement.
* Version 3.0.2, 24 March 2021
- Improvements to Spike Scope:
- Added RMS display, consistent with old software.
- Added spike rate display.
- Number of spikes in recent spike history can now be as high as 500.
- Each channel's recent spike history is persistent when channels are changed.
- Added 'Take Snapshot' and 'Clear Snapshot' buttons to permit freezing spike history in background of display on a per-channel basis.
- Added longer post-trigger spans to PSTH tool: 5s, 10s, and 20s.
- Added ability to use analog inputs as digital triggers in PSTH tool.
- Added ability to use analog inputs as digital triggers in Display Trigger (in Trigger tab).
- Added ability to display thresholded analog inputs as digital signals in Spectrogram Tool.
- In data file playback mode, added 'run immediately' option after 'jump to position'.
- Extended range of y-axis spacing between waveforms on waveform display.
- Fixed bug where 'Stop' button was not working during rewinding.
- Fixed bug where the 'Automatically Save Trigger Channel' option in triggered recording was not working.
- Fixed issue where software crashed upon exiting on some Macs.
- Fixed crashing upon software startup with some smaller screens.
- Improvements to TCP output:
- Added ability to disable and enable individual channels for TCP output while system is running.
- Improved TCP parser so that path names and file names may include spaces.
- Fixed TCP output timestamps to match timestamps in recorded data.
- Fixed issue where TCP data output could fill up software 'Waveform FIFO' buffer under certain conditions.
- Changed TCP parameter name 'DisplayTriggerAnalogVoltageThresholdVolts' to 'TriggerAnalogVoltageThresholdVolts'.
- Switched to latest version (v5.2.3) of Opal Kelly DLL.
- Changes to support Linux compilation.
- Windows installer:
- Fixed issue where certain anti-virus programs would interfere with Windows installation.
- Added additonal DLLs to Windows installation:
api-ms-win-core-winrt-string-l1-1-0.dll
api-ms-win-core-winrt-l1-1-0.dll
OpenCL.dll
* Version 3.0.3, 15 April 2021
- Added 50 ms option to PSTH pre-trigger and post-trigger spans.
- In "One File Per Signal Type" data file format, added option to save auxiliary inputs (e.g., acccelerometer data) in amplifier.dat file.
- Fixed bug that sometimes causes crashing when PC audio was enabled.
- Fixed bug that did not display auxiliary inputs or supply voltages from second headstage when dual headstage adapter was used.
- Expanded OpenCL compatibility to fix problems with OpenCL initialization on some systems.
* Version 3.0.4, 5 August 2021
- Fixed small memory leak that occurred when saving in the File Per Signal Type file format.
- Improved XML settings file parsing so that files that don't include any headstage channels can still be correctly loaded.
- Minor improvement to make error logging more detailed and efficient.
- Modify episodic triggered recording algorithm to ignore brief trigger-off events.
- Improved optimum SPI delay finding algorithm so that setting delay manually is less likely to be necessary.
- In data file playback mode, electrode impedances are now displayed.
- Fixed issue with external fast settling in RHD systems not properly triggering as a result of digital input activity
* Version 3.0.5, 3 February 2022
- Removed unused Context Help buttons from dialogs.
- Reduced latency of spike .dat file writing so that these files are updated as soon as spikes are detected.
- Added option to start software without OpenCL.
- Improved TCP parsing to handle unexpected whitespace in a string of commands.
- Added WriteToDiskLatency setting for users to control.
- Added CreateNewDirectory setting for users to control.
- Fixed displaying 'save to disk' icon for enabled non-amplifier signals (e.g., aux in, digital in, analog in).
- Fixed small memory leak during TCP data streaming.
- Altered 'Rescan Ports' behavior so that if the system went from no headstages to at least one detected, the displayed port will update to the present chip(s).
- Added drag'n'drop option for various settings files.
- Added more descriptive error messages when a Probe Map file is loaded as a general settings file.
- Fixed bug that would only flag channels as spike-TCP enabled if they were also waveform-TCP enabled.
- Removed unusable 'aux in wideband' checkbox hidden for RHS systems, because they don't have aux in channels.
- Added more descriptive error/warning messages when channels loaded from XML file are inconsistent with those currently plugged in.
- Fixed bug where loading data for playback that had aux inputs saved in wideband file wouldn't parse correctly.
- Fixed bug with external fast settling not properly triggering as a result of digital input activity.
* Version 3.0.6, 1 April 2022
- Fixed bug with FilePerChannel digital ins/outs not being indexed correctly.
- Increase max number of columns to 16.
- Put waveform display in a scroll area so that when too many columns are present to be displayed at once, a scroll bar can be used.
* Version 3.1.0, 3 June 2022
- Fixed memory issue that caused systems with multiple RHD2216 chips to erroneously duplicate channels.
- Added Plotting Mode options in the Performance menu, including a new High Efficiency mode that plots data more efficiently.
- Allowed some elements (including window size, position, and control panel state) of the basic GUI appearance to automatically load/save through QSettings.
- Added current channel name to the Window Title of the Spike Scope, ISI, PSTH, and Spectrogram tools.
- Added current loaded filename to the Window Title of the Probe Map tool.
* Version 3.2.0, 6 March 2023
- Allow user to specify which port(s) to read data from in Advanced dialog
- For One File Per Channel file format, when playing back data as it's being written, allow for jumping to the end of data for near-real-time playback
- Support for use of XEM7310 board in Intan controllers to replace XEM6010 and XEM6310
- Allow user to specify use of median instead of average for reference calculations
- Fix various issues with re-recorded playback data dropping data blocks at the end
- Allow user to specify whether or not to use max # of channels possible in synth mode
- Add "Get CurrentTimestamp" and "Get CurrentTimeSeconds" TCP commands
- Improved error detection and reporting for TCP commands
- Various improvements in RHX API including easier use of the API without Qt, and additional utility functions described in Rhythm and RhythmStim documentation.
* Version 3.3.0, 23 August 2023
- Improve TCP reception of commands to not duplicate slot connections
- Add Chip Test Mode
- Fix issue where for RHD chips, Rescan Ports would not run chip calibration
- Fix 7310 bit files so that for RHS systems, using a sample rate other than default (30 kHz) will no longer cause the software to use the wrong sample rate.
- Fix crashing when attempting to open a new file for recording fails, instead display an error message and stop acquisition.
* Version 3.3.1, 5 December 2023
- Add 10, 16, and 20 ms time scale options for Spike Scope
- Fix intermittent Stim Parameters dialog initialization issue that could cause incorrect values to appear
- Append date/timestamp to end of LiveNotes filename to avoid unintentional file overwriting for multi-file recording sessions
- Improve TCP functionality to allow for multiple connections/disconnections to occur without having to restart software
- Add TCP "execute" commands: SaveSettingsFile, LoadSettingsFile, SaveStimulationSettingsFile, LoadStimulationSettingsFile, analogous to already present UI elements.
- Improve test mode: wider acceptable input signal ranges, reduced likelihood of unintentionally entering test mode, and faster chip testing
* Version 3.3.2, 8 July 2024
- Improve chip testing mode, and give a more direct warning against using chip test mode for headstages
- Flush livenotes file every time a livenote occurs (useful for real-time applications that rely on livenotes)
- Fix XML loading of Port-specific parameters (manual delay, auxiliary digital out assignment) failing after Port A
- Fix intermittent crashing that would occur from hovering cursor in tooltip mode over border between signal types in plot
* Version 3.4.0, 4 February 2025
- Comprehensive codebase overhaul from Qt 5 to Qt 6
- Fix Spike Output TCP GUI unresponsiveness
- Add OpenCL setting to saved settings, allowing OpenCL to remain disabled between sessions if specified by user
- Small adjustments to preserve readability with Qt 6 GUI display
- Fix bug that could cause incorrect fast settle behavior during stimulation pulse trains
- Fix bug that could, under rare conditions, cause software to enter test mode upon startup