Request: forward all (well, most) signals to child process #240
Comments
Ah, you implemented that change to the PyInstaller bootloader after it had already influenced the staticx bootloader (167a585). No wonder it's not there! 😄 I agree, all signals should be forwarded, not just termination signals, with the exception of
I also think there's a mistake in pyinstaller/pyinstaller@2ddb80d in the bounds of the I'm experimenting with an implementation now, but I'm seeing some strange differences between |
Fixes #240 Inspired by pyinstaller/pyinstaller#3515
I've posted a draft PR in #242. The "strange differences" I was referring to were the fact that I'm still not sure we want to forward all signals 1-31 with I think we might consider instead an allowlist approach, including e.g.
|
So long as the allow list is configurable when running staticx (with some reasonable defaults as you listed), that sounds just fine to me. Thanks for looking into it! |
In my original case, I was wrapping a legacy application which arbitrarily used signal 42. (A lot has changed since 2018, though, and I could change this to something else now if needed.) |
I recently upgraded a Pyinstaller-built program to use Python 3.11. This resulted in the binary using a newer version of glibc than the target platform supported, which led me to discover staticx, without which this effort would be rather doomed. So first things first - thank you for building this. 🙂
Back when I first started using Pyinstaller, I noticed that most signals were not being forwarded to the child process. In particular, my program uses a somewhat arbitrary signal number to control the logging level of the child process. A more commonly-used example would be SIGHUP, which is often used to ask a daemon to reload its configuration from disk.
I made a change to the Pyinstaller bootloader back in 2018 whereby it forwards all signals (except
SIGCLD
/SIGCHLD
, because they're special) to the child process. I think something similar would work for staticx's (grammar...? 😅 ) bootloader, but I haven't had a chance to try it out yet.I might get some time to put together a PR for this, but I wanted to first open this issue so as to:
Thanks again!