You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
How does the explanation of how decide whether the model (in .model) is correct relates to the statement in the readme.
"The open state should have the highest emission parameters for all 4 signal components, the nucleosome state should have the second highest emission parameters for all 4 signal components and the background state should have the lowest emission parameters for all 4 signal components."
State 0
Pi: 0.3333333333333333
Aij: 0.962 0.031 0.007
Opdf: Multi-variate Gaussian distribution --- Mean: [ 0 0 0 0 ]
State 1
Pi: 0.3333333333333333
Aij: 0.045 0.939 0.015
Opdf: Multi-variate Gaussian distribution --- Mean: [ 0.075 0.125 0.009 0 ]
State 2
Pi: 0.3333333333333333
Aij: 0.005 0.007 0.988
Opdf: Multi-variate Gaussian distribution --- Mean: [ 0.134 0.217 0.188 0.097 ]
How does 'open', 'nuclear' and 'background' states relate to the above model? Should the 'aij' values or 'mean' values be used?
Thank you.
The text was updated successfully, but these errors were encountered:
State 0 is the background State, State 1 is the nucleosome state and state 2 is the open state (assuming default -k value)
Pi is the starting probability, ie the chance that the sequence starts with State i
Aij is the transition probability of moving from state i to state j
And the Opdf means are the mean values for the separated signal components. So for this model, the signal values for the open state are:
Mean: [ 0.134 0.217 0.188 0.097 ]
which satisfies the recommendation
How does the explanation of how decide whether the model (in .model) is correct relates to the statement in the readme.
"The open state should have the highest emission parameters for all 4 signal components, the nucleosome state should have the second highest emission parameters for all 4 signal components and the background state should have the lowest emission parameters for all 4 signal components."
How does 'open', 'nuclear' and 'background' states relate to the above model? Should the 'aij' values or 'mean' values be used?
Thank you.
The text was updated successfully, but these errors were encountered: