From 109cf00cfcd157c0f21777d0f393c03cc72eedde Mon Sep 17 00:00:00 2001
From: Eric Morway <emorway@usgs.gov>
Date: Sat, 14 Dec 2024 05:05:55 -0800
Subject: [PATCH] fix(mf6io): cleanup description of EVAPORATION keyword in SFE
 and LKE (#2103)

---
 doc/mf6io/mf6ivar/dfn/gwe-lke.dfn | 2 +-
 doc/mf6io/mf6ivar/dfn/gwe-sfe.dfn | 2 +-
 2 files changed, 2 insertions(+), 2 deletions(-)

diff --git a/doc/mf6io/mf6ivar/dfn/gwe-lke.dfn b/doc/mf6io/mf6ivar/dfn/gwe-lke.dfn
index 294250cfe26..6ddb8288739 100644
--- a/doc/mf6io/mf6ivar/dfn/gwe-lke.dfn
+++ b/doc/mf6io/mf6ivar/dfn/gwe-lke.dfn
@@ -415,7 +415,7 @@ in_record true
 reader urword
 time_series true
 longname evaporation temperature
-description real or character value that defines the temperature of evaporated water $(e.g., ^{\circ}C or ^{\circ}F)$ for the reach. If this temperature value is larger than the simulated temperature in the reach, then the evaporated water will be removed at the same temperature as the reach.  If the Options block includes a TIMESERIESFILE entry (see the ``Time-Variable Input'' section), values can be obtained from a time series by entering the time-series name in place of a numeric value.
+description use of the EVAPORATION keyword is allowed in the LKE package; however, the specified value is not currently used in LKE calculations.  Instead, the latent heat of evaporation is multiplied by the simulated evaporation rate for determining the thermal energy lost from a stream reach.
 
 
 block period
diff --git a/doc/mf6io/mf6ivar/dfn/gwe-sfe.dfn b/doc/mf6io/mf6ivar/dfn/gwe-sfe.dfn
index de720c285b0..ed7f29f2a3a 100644
--- a/doc/mf6io/mf6ivar/dfn/gwe-sfe.dfn
+++ b/doc/mf6io/mf6ivar/dfn/gwe-sfe.dfn
@@ -415,7 +415,7 @@ in_record true
 reader urword
 time_series true
 longname evaporation temperature
-description real or character value that defines the temperature of evaporated water $(e.g., ^{\circ}C or ^{\circ}F)$ for the reach. If this temperature value is larger than the simulated temperature in the reach, then the evaporated water will be removed at the same temperature as the reach.  If the Options block includes a TIMESERIESFILE entry (see the ``Time-Variable Input'' section), values can be obtained from a time series by entering the time-series name in place of a numeric value.
+description use of the EVAPORATION keyword is allowed in the SFE package; however, the specified value is not currently used in SFE calculations.  Instead, the latent heat of evaporation is multiplied by the simulated evaporation rate for determining the thermal energy lost from a stream reach.
 
 block period
 name runoff