Here you can find a brief description of the Leica CAM commands.
Currently leicacam have implemented some convenience methods:
- start_scan
- stop_scan
- pause_scan
- enable
- disable
- enable_all
- disable_all
- save_template
- load_template
- get_information
But all commands can be sent like this:
command = [('cmd', 'enableall'),
('value', 'true')]
cam.send(command)
cmd |
description |
startscan |
start matrix scan |
stopscan |
stop matrix scan |
pausescan |
toggle pause of matrix scan |
autofocusscan |
start matrix focus scan |
load |
load specific experiment from XML |
save |
save experiment positions to XML |
enable |
enable single scan field |
disable |
disable single scan field |
enableall |
enable all scan fields |
disableall |
disable all scan fields |
getinfo |
get information about stage, z-drive, COR-ring, job list, patter list, scan status, experiment, position, load position, autofocus mode (galvo or wide), autofocus position |
cmd |
description |
deletelist |
remove scan fields added to CAM list |
startcamscan |
start scan of CAM list |
stopcamscan |
stop scan of CAM list |
add |
add scan field to CAM list |
stopwaitingforcam |
close Waiting for External Command dialog and continue experiment |
skip |
close Waiting for External Command and stop, continue or leave pattern |
skip |
doesn't need wait for ext. command: continue with next job, scan field or well, or go to lower CAM level |
cmd |
description |
pump |
set pump and interval time for water pump |
adjust |
set settings for pinhole (airy units) or pmt (offset, gain) |
adjustls |
adjust light source, wavelength and intensity of laser |
loop |
adjust number of well loops and timing |
barcode |
set barcode of experiment |
adjustmosaic |
adjust width, height, start position and autofocus fields of mosaic |
adjustmatrix |
adjust start position, well distance and scan field distance of matrix |
enableattribute |
enable drift compensation, tracking or pump for given field |
cmd |
description |
setposition |
move stage or z-drive to specified position |
movetowell |
move to first scan field of given well |
savecurrentposition |
save a position to memory |
returntosavedposition |
return to a position saved in memory |
loadposition |
move to load position defined in experiment |
startposition |
move to start position defined in experiment |
cmd |
description |
selectfield |
select scan fields for assigning jobs |
selectallfields |
select all scan fields |
assignjob |
assign job to selected fields |
cmd |
description |
maf + addxyza |
insert position to mark and find list |
maf + delete |
delete mark and find list |
maf + load |
load mark and find list from xml |
maf + save |
save mark and find list to xml |
maf + toselected |
assign mark and find list to given well |
maf + toall |
assign mark and find list to all wells |