Skip to content

Commit

Permalink
Clarify emittance and solar absorptance inputs. [ci skip]
Browse files Browse the repository at this point in the history
  • Loading branch information
shorowit committed Oct 22, 2024
1 parent 27dd8ea commit 219d264
Showing 1 changed file with 6 additions and 6 deletions.
12 changes: 6 additions & 6 deletions docs/source/workflow_inputs.rst
Original file line number Diff line number Diff line change
Expand Up @@ -1214,8 +1214,8 @@ For a multifamily building where the dwelling unit has another dwelling unit abo
``Area`` double ft2 > 0 Yes Gross area (including skylights)
``Azimuth`` or ``Orientation`` integer or string deg or direction >= 0, <= 359 or See [#]_ No See [#]_ Direction (clockwise from North)
``RoofType`` string See [#]_ No asphalt or fiberglass shingles Roof type
``RoofColor`` or ``SolarAbsorptance`` string or double See [#]_ or >= 0, <= 1 No medium Roof color or solar absorptance [#]_
``Emittance`` double >= 0, <= 1 No 0.90 Emittance
``RoofColor`` or ``SolarAbsorptance`` string or double See [#]_ or >= 0, <= 1 No medium Roof color or solar absorptance of outermost material [#]_
``Emittance`` double >= 0, <= 1 No 0.90 Emittance of outermost material
``InteriorFinish/Type`` string See [#]_ No See [#]_ Interior finish material
``InteriorFinish/Thickness`` double in >= 0 No 0.5 Interior finish thickness
``Pitch`` double ?/12 >= 0 Yes Pitch [#]_
Expand Down Expand Up @@ -1277,8 +1277,8 @@ Each rim joist surface (i.e., the perimeter of floor joists typically found betw
``Area`` double ft2 > 0 Yes Gross area
``Azimuth`` or ``Orientation`` integer or string deg or direction >= 0, <= 359 or See [#]_ No See [#]_ Direction (clockwise from North)
``Siding`` string See [#]_ No wood siding Siding material
``Color`` or ``SolarAbsorptance`` string or double See [#]_ or >= 0, <= 1 No medium Color or solar absorptance [#]_
``Emittance`` double >= 0, <= 1 No 0.90 Emittance
``Color`` or ``SolarAbsorptance`` string or double See [#]_ or >= 0, <= 1 No medium Color or solar absorptance of outermost material [#]_
``Emittance`` double >= 0, <= 1 No 0.90 Emittance of outermost material
``Insulation/SystemIdentifier`` id Yes Unique identifier
``Insulation/AssemblyEffectiveRValue`` double F-ft2-hr/Btu > 0 Yes Assembly R-value [#]_
====================================== ================= ================ ======================== ======== =========== ==============================
Expand Down Expand Up @@ -1325,8 +1325,8 @@ Each wall surface is entered as a ``/HPXML/Building/BuildingDetails/Enclosure/Wa
``Area`` double ft2 > 0 Yes Gross area (including doors/windows)
``Azimuth`` or ``Orientation`` integer or string deg or direction >= 0, <= 359 or See [#]_ No See [#]_ Direction (clockwise from North)
``Siding`` string See [#]_ No wood siding Siding material
``Color`` or ``SolarAbsorptance`` string or double See [#]_ or >= 0, <= 1 No medium Color or solar absorptance [#]_
``Emittance`` double >= 0, <= 1 No 0.90 Emittance
``Color`` or ``SolarAbsorptance`` string or double See [#]_ or >= 0, <= 1 No medium Color or solar absorptance of outermost material [#]_
``Emittance`` double >= 0, <= 1 No 0.90 Emittance of outermost material
``InteriorFinish/Type`` string See [#]_ No See [#]_ Interior finish material
``InteriorFinish/Thickness`` double in >= 0 No 0.5 Interior finish thickness
``RadiantBarrier`` boolean No false Presence of radiant barrier [#]_
Expand Down

0 comments on commit 219d264

Please sign in to comment.