Update ThinkPulse_Getting_Started.md
add instructions for electrode prong replacement
- Loading branch information
1 parent
ceda874
commit 099690c
Showing
1 changed file
with
8 additions
and
6 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
|
@@ -18,16 +18,13 @@ This kit has been designed and its compatibility tested for the 8 and 16 channel | |
<br /> | ||
<br /> | ||
|
||
## ThinkPulse Starter Kit $349.99 Contents | ||
## ThinkPulse Starter Kit Contents | ||
|
||
<br /> | ||
|
||
![ThinkPulse contents](../../assets/ThirdPartyImages/ThinkPulse_starter_kit_contents.png) | ||
|
||
<br /> | ||
|
||
Note, the replacement set $99.99 is just for those who want backup electrode tips. The Starter Kit $349.99 includes the necessary electrodes and electrode tips. | ||
|
||
<br /> | ||
<br /> | ||
|
||
|
@@ -50,7 +47,6 @@ Below is the step-by-step tutorial by Conscious Labs on how to install the Think | |
The assembly video shows how to install the power supply board to a post-2018 Cyton and a pre-2018 Cyton. | ||
|
||
Some early ThinkPulse units have a hardware bug. The fix is a straightforward, quick solder job. The first minute of the video explains how to do it. | ||
|
||
ThinkPulse kits that shipped post-January 2021 are fixed and do not require soldering. | ||
If you need help or have any questions, email [[email protected]](mailto:[email protected]) | ||
|
||
|
@@ -65,7 +61,7 @@ If you need help or have any questions, email [[email protected]](mailto:suppo | |
|
||
[![cable management](../../assets/ThirdPartyImages/ThinkPulse_assembly_step5.png)](https://youtu.be/J2ZVDfayahs) | ||
|
||
## Using the ThinkPulse™ sensors with OpenBCI Cyton Board | ||
## Troubleshooting the ThinkPulse™ sensors with OpenBCI Cyton Board | ||
|
||
The following information applies specifically to Cyton and Cyton+Daisy Boards. If you are seeing `RAILED` in the GUI, try the following tips: | ||
|
||
|
@@ -79,6 +75,12 @@ The following information applies specifically to Cyton and Cyton+Daisy Boards. | |
|
||
![ThinkPulse and Cyton Channel Setting Example](../../assets/ThirdPartyImages/ThinkPulse_Cyton_HardwareChannelSetting.png) | ||
|
||
## How to replace ThinkPulse™ electrode prongs | ||
|
||
Removal: Insert a small flat screwdriver where the electrode prongs seat into the electrode body. Gently pull/twist until the prongs loosen. | ||
<br> | ||
Installation: To install replacement prongs, insert into the electrode body and twist until secure. | ||
|
||
## Technical Specs and Data Sheet | ||
|
||
**[Full Technical Information](https://drive.google.com/file/d/1Ri2UPmPH2SrTjYQ8Mj046ciWLGzRxCSl/view?usp=sharing)** | ||
|