-
Notifications
You must be signed in to change notification settings - Fork 96
Compatibility
karlzomo edited this page May 5, 2022
·
95 revisions
Do not upgrade EVO firmware versions to 7.50.000+ if you use Serial connection. Process is irreversible! Paradox introduces serial communication encryption which most probably will break our PAI ability to talk to the panel.
Other versions may be also supported. If PAI works with your panel, and the model-version combination is not listed, please edit the next table.
Panel | IP module | Conne- ction |
Notes | |||||
---|---|---|---|---|---|---|---|---|
Model | Version | IP100 | IP150 | IP150+ | Local IP | SWAN | Serial | |
EVOHD | 4.50 | - | - | - | - | ❌ | Did not work with ESP32. #198 | |
EVOHD | 6.91 | - | 4.42 | ✅ | - | - | ||
EVOHD | 7.30 | 4.42.002 | IP150 | ✅ | - | - | ||
EVOHD | 7.31 | 5.20.0E | - | ✅ | - | ✅ | Works with Serial via ESP32 | |
EVO48 | 2.20 | 5.10 | - | ✅ | - | - | ||
EVO192 | 2.66 | 5.10.06 | - | ✅ | - | - | ||
EVO192 | 3.20 | - | 5.3 | ✅ | - | - | ||
EVO192 | 6.86 | 5.10 | - | ✅ | - | - | ||
EVO192 | 6.90 | 5.1.0 | 1.32 | ✅ | - | ✅ | ||
EVO192 | 7.30 | - | 1.32 | ✅ | - | ✅ | ||
EVO192 | 7.30 | - | 4.42 | ✅ | - | - | ||
EVO192 | 7.31.1 | - | - | 5.02.019 | ✅ | - | - | |
EVO192 | 7.31 | - | - | 5.05 | ✅ | - | - | |
EVO192 | 7.52.1 | - | 1.34.000 | ✅ | - | - |
#272 This panel FW has encrypted serial but connects fine via IP150 |
|
EVO192 | 7.70.18 | - | 5.05.3 | ✅ | - | - |
#272 This panel FW has encrypted serial but connects fine via IP150 |
|
MG5000 | 4.16.20 | - | 4.40 | ✅ | - | - | ||
MG5000 | 4.8.0 | - | 5.03 | ✅ | - | - | ||
MG5050 | 4.96 | - | 4.40 | ✅ | - | ✅ | ||
MG5050 | 4.72 | - | 1.26 | ✅ | - | - | ||
MG5050 | 6.80 | - | 4.40 | ✅ | - | ✅ | ||
MG5050 | 7.15.2 | - | 4.40.04 | ✅ | - | - | ||
MG5050 | 7.15.2 | - | 5.02.042 | ✅ | - | - | ||
MG5050 | 7.01.12 | - | 5.02.019 | ✅ | - | - | ||
MG5075 | 1.3.8 | - | - | ✅ | - | ✅ | ||
SP4000 | 5.20 | - | 5.02.019 | ✅ | - | ✅ | ||
SP5500 | 2.40.1 | - | - | - | - | ✅ | ||
SP5500 | 4.54 | - | 4.42 | ✅ | - | - | ||
SP5500 | 4.94 | - | 5.02.45 | - | ✅ | - | - | Haven`t tested with Serial. Work on IP connection |
SP5500 | 4.94 | - | - | ✅ | - | ✅ | Works with Serial via ESP32 | |
SP5500 | 6.10.2 | - | - | - | - | ✅ | USB to Serial via FTDI | |
SP5500 | 7.14.2 | - | - | ✅ | - | ✅ | USB to Serial via FTDI | |
SP6000 | 4.15 | - | - | - | - | ✅ | ||
SP6000 | 4.54 | - | - | ✅ | ✅ | - | - | |
SP6000 | 4.94 | - | - | - | - | - | ✅ | |
SP6000 | 6.80 | - | 5.02 | ✅ | ✅ | - | More stable with SWAN disabled | |
SP6000 | 7.14.2 | - | 5.02.19 | - | ✅ | - | ✅ | Working with serial via ESP32 |
SP7000 | 5.18 | 5.20 | - | ✅ | - | - | ||
SP7000 | 5.20 | - | 4.40 | ✅ | - | - | ||
SP7000 | 6.90 | - | 4.42 | ✅ | - | - | ||
SP7000 | 7.14.2 | - | 5.2.9 | ✅ | ✅ | - | ||
SP7000 | 7.14.2 | - | - | - | - | - | ✅ | Both USB to serial (FTDI) and serial via ESP32 |
- MG6250 - unsupported protocol
For simpler table editing you can use https://www.tablesgenerator.com/markdown_tables
Copy only table to the editor. Not the whole page. Use Preview tab before submitting the change.
- PGM control requires fw 4.75+