Water Valve
A HomeKit water valve.
Type | Device Type |
---|---|
20 | Water Value |
The following configuration is available for thermostats:
Section | Name | Description |
---|---|---|
Actions | "a" | The actions performed by the accessory |
State Inputs | "f[n]" | Inputs that trigger a fixed event |
Ping State Inputs | "q[n]" | Ping input to set a state |
Accessory Notifications | "m" | Notifications to send to another accessory |
Initial State | "s" | State a switch accessory enters on boot |
Sensor Type | "w" | Type of sensor attached to accessory |
Maximum Use Time | "d" | Maximum time valve can be on |
{
"c": {
"b": [{ "g": 0, "t": 5 }]
},
"a": [{
"t": 20,
"f0": [{ "g": 0, "t": 1 }],
"f1": [{ "g": 0, "t": 2 }],
}]
}
This is an example of a water valve... ???
Key | Action | Description |
---|---|---|
"0" | OFF | (default) |
"1" | ON |
A water valve has two actions. The Digital Outputs
"r": [{}]
for each should be configured to attain the desired state.
Sensor Type defined by the "w"
key contained within the accessory object.
Type | Name | Description |
---|---|---|
0 | Water Valve | (default) |
1 | Sprinkler | |
2 | Shower | |
3 | Tap / Faucet |
Set the sensor type to indicate what type of water accessory is attached e.g.
"w": 2
indicates a sprinkler is attached.
A variety of one-wire sensors are available and supported by HAA.
Maximum use time is defined by the "d"
key contained within the accessory
object.
Key | State | Description |
---|---|---|
"d" | 0 | Timer disabled |
3600 | Timer set to 1 hour (default) | |
1 to ∞ | Time in seconds to set the use time |
This option limits the maximum amount of time that the water valve can be in the ON state. The default is to limit the valve on time to 3,600 seconds (1 hour), but this time period can be disabled, lengthened or shortened.
When the timer is enabled then the valve will be turned OFF after the maximum use time has elapsed.
State inputs are defined by an "f[n]"
key contained within the accessory
object. Where [n]
is the number of the associated state.
Key | Required State |
---|---|
"f0" | Valve Off |
"f1" | Valve On |
Refer to State Inputs for more detail and examples.
ICMP Ping inputs are defined by an "q[n]"
key contained within the accessory
object. Where [n]
is the number of the associated state.
Key | State |
---|---|
"q0" | Set state to On |
"q1" | Set state to Off |
Refer to ICMP Ping Inputs for more detail and examples.
The list of notifications "m"
supported by a water valve are as follows:
Value | Notification |
---|---|
0 | Valve OFF (default) |
1 | Valve ON |
See the general Accessory Notifications section for details of how to configure these notifications.
Initial state is defined by the "s"
key contained within the accessory object.
Key | State | Description |
---|---|---|
"s" | 0 | OFF (default) |
1 | ON | |
4 | Defined by fixed state inputs | |
5 | Last state before restart | |
6 | Opposite to last state before restart |
The initial state that a water valve enters on boot can be set using the
"s"
option.
Home Accessory Architect
Home Accessory
Installation
Setup Mode
HAA Home Manager App
Configuration
About
General
| GPIOs Configuration
Accessory
| Actions
Service Types
Air Quality
Battery
Data History
Fan
Free Monitor
Garage Door
HAA iAirZoning
Heater Cooler
Humidifier
Light Sensor
Lightbulb
Lock Mechanism
Sensors
Power Measure
Security System
Stateless Button & Doorbell
Switch & Outlet
Temperature & Humidity
TV
Water Valve
Window Covering