Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathmodbus_rtu.py.save.1
190 lines (177 loc) · 7.46 KB
/
modbus_rtu.py.save.1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
#!/usr/bin/python3
#fix for the imports
import os
import pymodbus
import serial
import struct
import numpy as np
from pymodbus.client.sync import ModbusSerialClient as MC
import time
import getopt
import datetime
from AWSclient import AWSclient
from localdb import localdb
#class containing the methods for iterative reading of data and publishing to mqtt
class modbus_rtu():
#Initilizing the parameters for the class instance
serial_no="" #usb cable
sensor_id=[]
stop_bits=[]
byte_size=[]
par="" #parity
baud_rate=[]
addrs=[] #modbus address
count=[] #count for each register
ut=0 #unit id of the modbus
cov=[] #change of value fraction/percentage
u=[] #unit of the data
type=[] #what the data represents : eg. temperature, resistance etc
scale=1
signed=1
dtype=1
name=""
aws=AWSclient()
myAWSIoTMQTTClient=aws.myAWSIoTMQTTClient
conn=aws.conn
dead=False
def __init__(self,serial_no,sensor_id,stop_bits,byte_size,par,baud_rate,addrs,count,ut,cov,u,type,scale,signed,name):
self.serial_no=serial_no
self.sensor_id=sensor_id
self.stop_bits=stop_bits
self.byte_size=byte_size
self.par=par
self.baud_rate=baud_rate
self.addrs=addrs
self.count=count
self.ut=ut
self.cov=cov
self.u=u
self.type=type
self.scale=scale.astype(float)
self.signed=signed
self.name=name
self.publish_to_mqtt()
#Function to convert the raw values to float
def to_float(self,og_type,data):
if og_type==1:
s= data
elif og_type==2: #Checking the type of raw vaue . Here 2 ='floating-point'
ms=hex(data[0]) #most significant in hexa-decimal
ls=hex(data[1]) # least significant in hexa-decimal
val_hex=ms[2:]+ls[2:] # combining
val_f=0
try:
val_f=struct.unpack('f',struct.pack('i',int(val_hex,16))) # converting from floating point hex to decimal
except:
pass
# getting rid of the 'brackets' in the string containing the final decimal value after conversion
s=str(val_f)
chars='(,)'
for ch in chars:
s=s.replace(ch,"")
return s
# Publishing to mqtt
def pub(self,timestamp,sensor_id,s,units,type):
aws=AWSclient()
myAWSIoTMQTTClient=aws.myAWSIoTMQTTClient
conn=aws.conn
topic = "NE/RPi"
msg = '"Time": "{}", "Device":"{}", "Value": "{}","Units":"{}","Type":"{}"'.format(timestamp,sensor_id,s,units,type)
msg = '{'+msg+'}'
self.myAWSIoTMQTTClient.publish(topic, msg, 1)
def publish_to_mqtt(self):
#Publish to the topic in a loop
loopCount = 0
delay_read = 5 # delay in seconds for reading the sensor
u1=self.u
#Configuring the port address
#p='/dev/serial/by-id/usb-ATC_USB_High_Speed_RS-485_Converter_'+serial_no+'-if00-port0'
#getting the device-id's of the USBs in the directory
dir=os.listdir('/dev/serial/by-id')
#Taking the device path id which contains the serial number given
for dv in dir:
if self.serial_no in dv:
p = '/dev/serial/by-id/'+dv
else:
raise Exception('{} USB device not found'.format(serial_no))
# print(p)
#Passing the arguments for establishing connection with modbus rtu device: MC-> ModbusSerialClient
# print(p,self.stop_bits,self.byte_size,self.par,self.baud_rate)
c = MC(method='rtu',port=p,stopbits=self.stop_bits,
bytesize=self.byte_size,parity=self.par,baudrate=self.baud_rate)
con = c.connect()
# print(con)
#getting the dimensions of the sensor_id 2d array
dim_rgstrs=np.shape(self.sensor_id)
# print(dim_rgstrs)
try:
while (not self.dead):
loopCount += 1
timestamp = datetime.datetime.now()
#Initializing variables for the values in last read and current read for checking the CoV condition
if loopCount==1:
last_val=(np.zeros((dim_rgstrs[0],dim_rgstrs[1]))).astype(str)
new_val=(np.zeros((dim_rgstrs[0],dim_rgstrs[1]))).astype(str)
#Loop for reading the registers: Outer loop(j=rows) for transversing each device (boilers), inner loop(i=columns) for each register
for j in range(dim_rgstrs[0]):
for i in range(dim_rgstrs[1]):
# print(self.addrs[j,i])
if (self.addrs[j,i])!='':
#Reading the values after checking the regitser addresses(input or holding)
if int(self.addrs[j,i])>=30000 and int(self.addrs[j,i])<40000:
r = c.read_input_registers(int(self.addrs[j,i])-30001,int(self.count[j,i]),unit=int(self.ut[j]))
else:
r = c.read_holding_registers(int(self.addrs[j,i])-40001,int(self.count[j,i]),unit=int(self.ut[j]))
data=r.registers
# print(data)
# print('dev no: {}'.format(self.ut[j]))
# Conversion to decimal from the raw data type
s=(self.to_float(self.dtype,data[0]))
#Checking if data is signed and ten converting accordingly
if self.signed[j,i]!=1:
if s>32767:
s=s-65535
s=s*(self.scale[j,i])
#Converting to Farhenheit
# if self.u[j,i]=="C":
# print("INSIDE")
# s=(s*9/5)+32
# u1[j,i]="F"
# storing the previous values and checking for CoV
if loopCount==1:
last_val[j,i]=s
new_val[j,i]=s
else:
new_val[j,i]=s
# print(' last: "{}", current:"{}"'.format(last_val,new_val))
# Checking the CoV condition and publishing if satifies
try:
if (abs(float(new_val[j,i])-float(last_val[j,i]))/(float(last_val[j,i]))>float(self.cov[j,i])):
print("Value greater than CoV")
self.pub(timestamp,self.sensor_id[j,i],s,u1[j,i],self.name[j,i])
except ZeroDivisionError:
print(float('inf'))
print(' Loop {:d}'.format(loopCount))
print(' Time: {} Device: {} \nName: {}'.format(timestamp,self.sensor_id[j,i],self.name[j,i]))
print("Value: {} ".format(s))
# Normal publishing when loopCount =5 i.e 5*5=25 sec
if(loopCount%12==0):
#Writing in the local database
if localdb().conn=='1':
try:
self.pub(timestamp,self.sensor_id[j,i],s,u1[j,i],self.name[j,i]) #publishing the data to aws mqtt
localdb().write_to_localdb(timestamp,self.sensor_id[j,i],s,u1[j,i],self.name[j,i],'1','1')
localdb().publish_to_mqtt()
print("written to localdb")
except:
pass
else:
localdb().write_to_localdb(timestamp,self.sensor_id[j,i],s,u1[j,i],self.name[j,i],'0','0')
last_val=new_val
time.sleep(delay_read)
except KeyboardInterrupt:
pass
# print('Exiting the loop')
self.myAWSIoTMQTTClient.disconnect()
print('Disconnected from AWS')
#modbus_rtu('AQ002Q52',[1432301,1432311],1,8,'E',19200,[400001,400001],[2,2],1,[0.05,.05],["C","C"],["Temperature","Temperature"])