Notifications
You must be signed in to change notification settings - Fork 0
/
calibrateLogger.m
66 lines (54 loc) · 2 KB
/
calibrateLogger.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
function calibrateLogger( logger )
% CALIBRATELOGGER Given an instance of the DataLogger class, this function
% calibrates the channels with the utility or uses the saved
% information to restore a past calibration
%
% Load previous calibration if exists data
if exist('calibrationData.mat', 'file')
load('calibrationData.mat', 'Units');
end
if exist('Units', 'var')
PreviousUnits = Units; %#ok<NODEF>
end
% Get the required varaibles from the logger
ChanMat = logger.ChanMat;
Units = logger.Units;
% Test each channel
for i=1:4
if ChanMat(i,1)
if exist('PreviousUnits', 'var') && ~isempty(PreviousUnits{i})
% If there was a calibration file, ask the user wether to use it or not
selection = questdlg(['Load previous calibration for channel ' num2str(i) '?'],...
'Confirmation',...
'Yes','No','Yes');
switch selection,
case 'Yes',
% Use previous calibration
Units{i} = PreviousUnits{i};
case 'No'
% Launch the calibration tool
Units{i} = calibrate(logger, i);
end
else
% Launch the calibration tool
Units{i} = calibrate(logger, i);
end
end
end
% Save this new calibration settings
save('calibrationData', 'Units');
logger.Units = Units;
end
% This functions launches the claibration tools
function [Units] = calibrate(logger, i)
% Create a calibration utility instance with the callback to stop the
% the logger when its necessary
utility = calibrationUtility2016(['Calibrate channel ' num2str(i)], @logger.stopRealTime);
% Start getting data and send it to the calibration utility
% Send only one point at a time (we take the mean)
logger.getRealTime(0, @(dec, t)(utility.updateCurrentPoint(mean(dec(:,i)))));
% Save the retults
Units = utility.Units;
% Delete the calibration utility
utility.delete();
end