Releases: Trunks1982/Daikin-Rotex-HPSU-CAN-Seriell
Releases · Trunks1982/Daikin-Rotex-HPSU-CAN-Seriell
2024.12.1
New sensors and settings
ta2:
name: TA2
tliq:
name: Tliq
Features and Fixes
- Fixed
T-Aussen
sensor for negative values - Fixed malfunction detection for valves
- Fixed
TvBH
forGCU compact
- Added workaround for BPV detection for HPSU v4
- Set
wifi.power_save_mode
tonone
inexamples/full.yaml
2024.11.2
New sensors and settings
energy_cooling:
name: Energie Kühlung
total_electrical_energy:
name: Elektrische Energie Gesamt
external_temp_sensor:
name: SKonfig T-Außen
energy_saving_mode:
name: ES mode
Features and Fixes
- Fixed
optimized_defrosting
whentemperature_antifreeze
is not used - Fixed
optimized_defrosting
when switching back fromWarmwasserbereitung
- Fixed negative
temperature_outside
sensor values
2024.11.1
New sensors and settings
temperature_antifreeze:
name: T-Frostschutz
Features and Fixes
- Fix
WW bereiten
whenWW Soll
is a Number - Add misbehavior detection for 3UV-DHW and 3UV-BPV
- Disable
temperature_antifreeze
whenoptimized_defrosting
is enabled - Disable
optimized_defrosting
whentemperature_antifreeze
changes - Fix optimized defrosting
New controll settings for misbehavior detection
daikin_rotex_can:
max_spread_tvbh_tv: 4
max_spread_tvbh_tr: 4
These settings are required if Tv
, Tr
or TvBH
measure inaccurately, leading to error messages even though the pump itself is functioning well.
2024.09.6
New sensors and settings
project_git_hash:
name: Project Git Hash
optimized_defrosting:
name: Abtau-Optimierung
heating_limit_day:
name: Heizgrenze Tag
heating_limit_night:
name: Heizgrenze Nacht
flow_temperature_night:
name: T Vorlauf Nacht
max_target_flow_temp:
name: Max T-Vorlauf
min_target_flow_temp:
name: Min T-Vorlauf
max_heating_temperature:
name: Max Temp Heizung
supply_temperature_adjustment_heating:
name: Anpassung T-VL Heizen
supply_temperature_adjustment_cooling:
name: Anpassung T-VL Kühlen
1_dhw:
name: 1 x Warmwasser
hp_hyst_tdhw:
name: WPHyst TDHW
delay_time_for_backup_heating:
name: Wartezeit BOH
Features and Fixes
- When switching settings on the HP control panel, all sensors now update immediately
- Fixed an issue where some sensors displayed incorrect values when a RoCon G1 was connected
- Increased the accuracy of
flow_temperature_day
andflow_temperature_night
settings to0.1
2024.09.5
New sensors and settings
flow_rate_min:
name: Durchfluss Min
flow_rate_setpoint:
name: Durchfluss Soll
flow_rate_calc:
name: DurchflussBer
flow_rate_hyst:
name: Durchfluss Hyst
Features and fixes
- All numerical values can now be changed to combos. See:
T-WW-Soll
andRaumsoll
examples in options.yaml Spreizung HZ
andSpreizung WW
andFlüsterbetrieb
is now adjustable- Show
---
forExt
whenSmart Grid
orSG Modus
are disabled - Fixed device_class and unit_of_measurement warnings in HA log for percent and flow sensors
2024.09.4
Added the following new sensors / numbers / selects:
function_ehs:
name: Funktion EHS
ch_support:
name: HZ Unterstützung
power_dhw:
name: Leistung WW
power_ehs_1:
name: Leistung EHS Stufe 1
power_ehs_2:
name: Leistung EHS Stufe 2
power_biv:
name: Leistung BIV
tdiff_dhw_ch:
name: TDiff-WW HZU
electric_heater:
name: Heizstäbe
ext:
name: Ext
Additional features and fixes:
- Remove 0x prefix from messages in log
- Fix esp crash when thermal_power sensor was not used
2024.09.3
Added the following new sensors:
antileg_temp:
name: AntilegTemp
circulation_interval_on:
name: ZirkInterval An
circulation_interval_off:
name: ZirkInterval Aus
tdiff_dhw_ch:
name: TDiff-WW HZU
dhw_off_time:
name: WW Sperrzeit
max_dhw_loading:
name: Max WW Ladezeit
t_dhw_1_min:
name: Schaltschwelle TDHW
antileg_day:
name: AntilegTag
circulation_with_dhw_program:
name: Zirk mit WW-Prog
outdoor_unit:
name: Aussengerät
indoor_unit:
name: Innengerät
Additional features and fixes:
- Added dump button (writes configuration to the log)
- Fixed handling of messages initiated by RoCon
- Fixed missing requests at startup
2024.09.2
2024.09.1
Added the following new sensors:
qboh:
name: EHS für DHW
qch:
name: Energie Heizung
quiet:
name: Flüsterbetrieb
t_ext:
name: T-Aussen
t_hs:
name: T-WE
Added new text controls (development helpers):
log_filter: # Allows textual filtering of log outputs
name: Log Filter
custom_request: # Allows byte sequences to be sent to the heat pump (facilitates the development of new entities)
name: Custom Request
kleine Verbesserungen
SG Modus, Smart Grid hinzugefügt