Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

[SMOKE TEST]: v2408 Gated OS Testing #9

Closed
4 of 13 tasks
gus33000 opened this issue Jul 25, 2024 · 6 comments
Closed
4 of 13 tasks

[SMOKE TEST]: v2408 Gated OS Testing #9

gus33000 opened this issue Jul 25, 2024 · 6 comments
Assignees

Comments

@gus33000
Copy link
Member

gus33000 commented Jul 25, 2024

Goal is to validate the upcoming release and catch issues ahead of time before release. Below is the list of "must be compatible" targets for 2408, a tick means testing passed:

  • Surface Duo (1st Gen)

    • RS4 Client
    • Calcium Client
    • Titanium/Vanadium Client
    • Vibranium Client
    • Manganese Client
    • Iron Client
    • Iron Server
    • Iron WCOS
    • Cobalt Client
    • Cobalt WCOS
    • Nickel Client
    • Germanium Client
  • Surface Duo 2

    • Germanium Client
@gus33000 gus33000 self-assigned this Jul 25, 2024
@gus33000
Copy link
Member Author

gus33000 commented Jul 25, 2024

NB: 18362.1 Titanium Semester builds do not boot at all on GICv3 hardware due to a bug, a Cumulative Update is required to address this issue, .1 is a "cant fix" scenario in above matrix.

@gus33000
Copy link
Member Author

Failures observed on NI/CO/etc: #2 #1

@gus33000
Copy link
Member Author

Ok release for this week is halted

#8

This must get fixed, improper battery management could potentially result in >1A current going through the hinge connection wires which is way above spec and would damage them if thats the reason for the fail trigger.

Will revist testing once fixed

@gus33000 gus33000 reopened this Jul 26, 2024
@gus33000
Copy link
Member Author

Driver Load order issue found on VB_RELEASE triggering BlackScreen issue on first boot due to clash between SLPI Hall sensor initialization (for hinge angle and posture sensor algos) as well as lid functionality in the OS.

Such issue does not happen on GE_RELEASE and CO_RELEASE so far with privately available firmware patch of 7/26

@gus33000
Copy link
Member Author

Zeta is non functional on GE_RELEASE due to two key issues:

  • Hypervisor fault upon loading ADSP node in HLOS
  • IRQ storm on PEP device for either PCIe, TSENS, CPUSS or RDM after a few mins

@gus33000
Copy link
Member Author

=> release delayed again

@gus33000 gus33000 transferred this issue from WOA-Project/SurfaceDuo-Drivers Aug 20, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment