Notifications
You must be signed in to change notification settings - Fork 14
/
Copy pathgrowatt.py
229 lines (207 loc) · 11.8 KB
/
growatt.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
import datetime
from pymodbus.exceptions import ModbusIOException
# Codes
StateCodes = {
0: 'Waiting',
1: 'Normal',
2: 'Discharging',
3: 'Fault'
}
ErrorCodes = {
0: 'None',
24: 'Auto Test Failed',
25: 'No AC Connection',
26: 'PV Isolation Low',
27: 'Residual Current High',
28: 'DC Current High',
29: 'PV Voltage High',
30: 'AC Voltage Outrange',
31: 'AC Freq Outrange',
32: 'Module Hot'
}
for i in range(1, 24):
ErrorCodes[i] = "Error Code: %s" % str(99 + i)
DeratingMode = {
0: 'No Deratring',
1: 'PV',
2: '',
3: 'Vac',
4: 'Fac',
5: 'Tboost',
6: 'Tinv',
7: 'Control',
8: '*LoadSpeed',
9: '*OverBackByTime',
}
def read_single(row, index, unit=10):
return float(row.registers[index]) / unit
def read_double(row, index, unit=10):
return float((row.registers[index] << 16) + row.registers[index + 1]) / unit
def merge(*dict_args):
result = {}
for dictionary in dict_args:
result.update(dictionary)
return result
class Growatt:
def __init__(self, client, name, unit):
self.client = client
self.name = name
self.unit = unit
self.read_info()
def read_info(self):
row = self.client.read_holding_registers(73, unit=self.unit)
if type(row) is ModbusIOException:
raise row
self.modbusVersion = row.registers[0]
def print_info(self):
print('Growatt:')
print('\tName: ' + str(self.name))
print('\tUnit: ' + str(self.unit))
print('\tModbus Version: ' + str(self.modbusVersion))
def read(self):
row = self.client.read_input_registers(0, 33, unit=self.unit)
if type(row) is ModbusIOException:
return None
# http://www.growatt.pl/dokumenty/Inne/Growatt%20PV%20Inverter%20Modbus%20RS485%20RTU%20Protocol%20V3.04.pdf
# # Unit, Variable Name, Description
info = { # ==================================================================
'StatusCode': row.registers[0], # N/A, Inverter Status, Inverter run state
'Status': StateCodes[row.registers[0]],
'Ppv': read_double(row, 1), # 0.1W, Ppv H, Input power (high)
# 0.1W, Ppv L, Input power (low)
'Vpv1': read_single(row, 3), # 0.1V, Vpv1, PV1 voltage
'PV1Curr': read_single(row, 4), # 0.1A, PV1Curr, PV1 input current
'PV1Watt': read_double(row, 5), # 0.1W, PV1Watt H, PV1 input watt (high)
# 0.1W, PV1Watt L, PV1 input watt (low)
'Vpv2': read_single(row, 7), # 0.1V, Vpv2, PV2 voltage
'PV2Curr': read_single(row, 8), # 0.1A, PV2Curr, PV2 input current
'PV2Watt': read_double(row, 9), # 0.1W, PV2Watt H, PV2 input watt (high)
# 0.1W, PV2Watt L, PV2 input watt (low)
'Pac': read_double(row, 11), # 0.1W, Pac H, Output power (high)
# 0.1W, Pac L, Output power (low)
'Fac': read_single(row, 13, 100), # 0.01Hz, Fac, Grid frequency
'Vac1': read_single(row, 14), # 0.1V, Vac1, Three/single phase grid voltage
'Iac1': read_single(row, 15), # 0.1A, Iac1, Three/single phase grid output current
'Pac1': read_double(row, 16), # 0.1VA, Pac1 H, Three/single phase grid output watt (high)
# 0.1VA, Pac1 L, Three/single phase grid output watt (low)
'Vac2': read_single(row, 18), # 0.1V, Vac2, Three phase grid voltage
'Iac2': read_single(row, 19), # 0.1A, Iac2, Three phase grid output current
'Pac2': read_double(row, 20), # 0.1VA, Pac2 H, Three phase grid output power (high)
# 0.1VA, Pac2 L, Three phase grid output power (low)
'Vac3': read_single(row, 22), # 0.1V, Vac3, Three phase grid voltage
'Iac3': read_single(row, 23), # 0.1A, Iac3, Three phase grid output current
'Pac3': read_double(row, 24), # 0.1VA, Pac3 H, Three phase grid output power (high)
# 0.1VA, Pac3 L, Three phase grid output power (low)
'EnergyToday': read_double(row, 26), # 0.1kWh, Energy today H, Today generate energy (high)
# 0.1kWh, Energy today L, Today generate energy today (low)
'EnergyTotal': read_double(row, 28), # 0.1kWh, Energy total H, Total generate energy (high)
# 0.1kWh, Energy total L, Total generate energy (low)
'TimeTotal': read_double(row, 30, 2), # 0.5S, Time total H, Work time total (high)
# 0.5S, Time total L, Work time total (low)
'Temp': read_single(row, 32) # 0.1C, Temperature, Inverter temperature
}
row = self.client.read_input_registers(33, 8, unit=self.unit)
info = merge(info, {
'ISOFault': read_single(row, 0), # 0.1V, ISO fault Value, ISO Fault value
'GFCIFault': read_single(row, 1, 1), # 1mA, GFCI fault Value, GFCI fault Value
'DCIFault': read_single(row, 2, 100), # 0.01A, DCI fault Value, DCI fault Value
'VpvFault': read_single(row, 3), # 0.1V, Vpv fault Value, PV voltage fault value
'VavFault': read_single(row, 4), # 0.1V, Vac fault Value, AC voltage fault value
'FacFault': read_single(row, 5, 100), # 0.01 Hz, Fac fault Value, AC frequency fault value
'TempFault': read_single(row, 6), # 0.1C, Temp fault Value, Temperature fault value
'FaultCode': row.registers[7], # Fault code, Inverter fault bit
'Fault': ErrorCodes[row.registers[7]]
})
# row = self.client.read_input_registers(41, 1, unit=self.unit)
# info = merge_dicts(info, {
# 'IPMTemp': read_single(row, 0), # 0.1C, IPM Temperature, The inside IPM in inverter Temperature
# })
row = self.client.read_input_registers(42, 2, unit=self.unit)
info = merge(info, {
'PBusV': read_single(row, 0), # 0.1V, P Bus Voltage, P Bus inside Voltage
'NBusV': read_single(row, 1), # 0.1V, N Bus Voltage, N Bus inside Voltage
})
# row = self.client.read_input_registers(44, 3, unit=self.unit)
# info = merge_dicts(info, {
# # Check Step, Product check step
# # IPF, Inverter output PF now
# # ResetCHK, Reset check data
# })
#
# row = self.client.read_input_registers(47, 1, unit=self.unit)
# info = merge_dicts(info, {
# 'DeratingMode': row.registers[6], # DeratingMode, DeratingMode
# 'Derating': DeratingMode[row.registers[6]]
# })
row = self.client.read_input_registers(48, 16, unit=self.unit)
info = merge(info, {
'Epv1_today': read_double(row, 0), # 0.1kWh, Epv1_today H, PV Energy today
# 0.1kWh, Epv1_today L, PV Energy today
'Epv1_total': read_double(row, 2), # 0.1kWh, Epv1_total H, PV Energy total
# 0.1kWh, Epv1_total L, PV Energy total
'Epv2_today': read_double(row, 4), # 0.1kWh, Epv2_today H, PV Energy today
# 0.1kWh, Epv2_today L, PV Energy today
'Epv2_total': read_double(row, 6), # 0.1kWh, Epv2_total H, PV Energy total
# 0.1kWh, Epv2_total L, PV Energy total
'Epv_total': read_double(row, 8), # 0.1kWh, Epv_total H, PV Energy total
# 0.1kWh, Epv_total L, PV Energy total
'Rac': read_double(row, 10), # 0.1Var, Rac H, AC Reactive power
# 0.1Var, Rac L, AC Reactive power
'E_rac_today': read_double(row, 12), # 0.1kVarh, E_rac_today H, AC Reactive energy
# 0.1kVarh, E_rac_today L, AC Reactive energy
'E_rac_total': read_double(row, 14), # 0.1kVarh, E_rac_total H, AC Reactive energy
# 0.1kVarh, E_rac_total L, AC Reactive energy
})
# row = self.client.read_input_registers(64, 2, unit=self.unit)
# info = merge_dicts(info, {
# 'WarningCode': row.registers[0], # WarningCode, Warning Code
# 'WarningValue': row.registers[1], # WarningValue, Warning Value
# })
#
# info = merge_dicts(info, self.read_fault_table('GridFault', 90, 5))
return info
# def read_fault_table(self, name, base_index, count):
# fault_table = {}
# for i in range(0, count):
# fault_table[name + '_' + str(i)] = self.read_fault_record(base_index + i * 5)
# return fault_table
#
# def read_fault_record(self, index):
# row = self.client.read_input_registers(index, 5, unit=self.unit)
# # TODO: Figure out how to read the date for these records?
# print(row.registers[0],
# ErrorCodes[row.registers[0]],
# '\n',
# row.registers[1],
# row.registers[2],
# row.registers[3],
# '\n',
# 2000 + (row.registers[1] >> 8),
# row.registers[1] & 0xFF,
# row.registers[2] >> 8,
# row.registers[2] & 0xFF,
# row.registers[3] >> 8,
# row.registers[3] & 0xFF,
# row.registers[4],
# '\n',
# 2000 + (row.registers[1] >> 4),
# row.registers[1] & 0xF,
# row.registers[2] >> 4,
# row.registers[2] & 0xF,
# row.registers[3] >> 4,
# row.registers[3] & 0xF,
# row.registers[4]
# )
# return {
# 'FaultCode': row.registers[0],
# 'Fault': ErrorCodes[row.registers[0]],
# #'Time': int(datetime.datetime(
# # 2000 + (row.registers[1] >> 8),
# # row.registers[1] & 0xFF,
# # row.registers[2] >> 8,
# # row.registers[2] & 0xFF,
# # row.registers[3] >> 8,
# # row.registers[3] & 0xFF
# #).timestamp()),
# 'Value': row.registers[4]
# }