Skip to content

Releases: asantaga/wiserHomeAssistantPlatform

R3.3.6

16 May 20:58
8e36ddf
Compare
Choose a tag to compare

What's Changed

  • Improved Zigbee network card

R3.3.5

09 May 12:41
fd006e4
Compare
Choose a tag to compare

What's Changed

  • Fix for eroneous current temp if lost signal with TRV - issue #369
  • Reduced log error level for failed update form hub to warning

R3.3.4

24 Apr 15:02
f174fb1
Compare
Choose a tag to compare
  • Fix issue with passive mode whereby it did not factor heating channels for multi channel hubs

R3.3.3

14 Apr 17:07
80bbf09
Compare
Choose a tag to compare

What's Changed

  • Fix issue of passive mode temperature increment setting not working - issue #359
  • Improved error handling if the extra config file should get corrupted - issue #364
  • Current target temp now uses DisplayedSetPoint from hub to better show correct temp when EcoIQ is active

R3.3.2

05 Apr 14:38
acd6997
Compare
Choose a tag to compare

What's Changed

  • Fix issue with HA hanging when trying to change Alexa exposed entities with this integration enabled - issue #360
  • Fix issue whereby the passive mode increments are not maintained on hub update - issue #359
  • Added attribute to climate entity to see passive mode temp increment value

R3.3.1

22 Mar 18:42
f5edbaa
Compare
Choose a tag to compare

v3.3.1

  • Bump api to v1.3.1
  • Number of improvements to passive mode automation
  • Breaking change - where the automations were enabled in v3.3.0, this will need re-enabling in v3.3.1 due to changes in the config configuration
  • Added is_passive attribute to climate entity
  • Added that away mode overrides passive mode
  • Added config option to manage passive mode temperature increments
  • Added hub update if built in automations make changes to hub to reflect current status immediately
  • Storage of the manual set temp in the (now existing) integration storage file to presist after a HA restart
  • Added additional opentherm parameters - issue #337
  • Corrected error saving on/off schedule - issue #349

R3.3.1beta2

14 Mar 18:59
Compare
Choose a tag to compare
R3.3.1beta2 Pre-release
Pre-release

This is a beta release and therefore can contain bugs or changes that may be reverted/amended later. Please be cognisant of that when installing.

  • Bump api to v1.3.0
  • Breaking change - if you have installed and used passive mode in v3.3.1beta, this version will leave orphaned select entities that will need to be deleted manually.
  • Breaking change - if you have previously set passive mode to follow schedule on some rooms, these may be now in passive mode manual and will need to be set to follow schedule again.
  • Reworking of passive mode to be based on the auto/heat/off HVAC modes with passive mode on/off switch
  • Storage of the manual set temp in the (now existing) integration storage file to presist after a HA restart
  • Move of an amount of preset mode management to the api instead of integration code

R3.3.1beta

01 Mar 09:21
Compare
Choose a tag to compare
R3.3.1beta Pre-release
Pre-release
  • Added Passive Mode Follow Schedule
  • Added support for boost in passive mode - issue #348
  • BREAKING CHANGE: Switch for enabling passive mode is removed in favour of a selector to select passive mode type
  • BREAKING CHANGE: LTS sensors and Moments are now enabled by default
  • Added additional Opentherm attributes to Flow Temp Sensor - issue #337
  • Fixed error when saving/setting On/Off schedule via service or schedule card - issue #350

R3.3.0

11 Feb 13:23
fff9112
Compare
Choose a tag to compare

This is the release version of 3.2.3beta versions. Below is all changes from v3.2.2 to v3.3.0.

What's Changed

  • Bump api to v1.0.2
  • Add event data to wiser events - issue #324
  • Fix error setting away mode action for shutters - issue #329
  • Add support for Heating Actuator floor temp sensor - issue #334
  • Improve error handling/notification for setting schedule via YAML file - issue #325
  • Add service for setting opentherm parameters
  • Added LTS Floor Temp Sensor for Heating Actuators - issue #337
  • Added flow and return temp sensors for Opentherm boilers - issue #337
  • Added new passive mode for rooms with api smarts
  • Improved repeater name on device signal entity - issue #345
  • Fix beta issue creating floor temp sensor when not fitted due to odd hub data - issue #340
  • Fix beta issue of error when calling boost all
  • Fix beta issue of error setting schedules from YAML file
  • Fixed beta issue of error during setup

R3.2.3beta3

21 Jan 18:05
Compare
Choose a tag to compare
R3.2.3beta3 Pre-release
Pre-release

This is a beta release with changes that have not been fully tested due to lack of equipment to do so. Use at your own risk until the community that have this equipment have confirmed it working and this is released formally.

  • Added additional opentherm parameters
  • Created new flow and return sensors for opentherm boilers
  • BREAKING CHANGE - attributes for opentherm boilers moved to flow sensor. Previous attributes on heating circuit sensor deprecated and will be removed in future release.
  • Added room passive mode - very beta - use at own risk and cost of gas!