Notifications
You must be signed in to change notification settings - Fork 55
How To
See Bugs for a list of known issues.
If these instructions don't make sense, see #41.
Clone the repo, including submodules:
git clone --recursive https://github.com/bangcorrupt/hacktribe.git
cd hacktribe
Download Electribe 2 Sampler firmware version 2.02 and move SYSTEM.VSB
to hacktribe
directory.
Apply patch to Electribe Sampler firmware version 2.02 only.
Once patched, the firmware will run on either device.
Complete Prepare Files step above.
Install dependencies:
pip install argparse bsdiff4
Run e2-firmware-patch.py
script to patch the firmware automatically:
python scripts/e2-firmware-patch.py
If installing to factory synth (grey or blue), use -e
flag to also modify file header.
Complete Prepare Files step above.
Install Hacktribe Editor.
Follow the instructions in the app, pay attention to the log output in the text box.
Installation may fail on Windows.
In that case, run the executable found in the repo at hacktribe-editor/hacktribe-gui.exe
.
See this comment for why it doesn't work and how to fix it.
You should see:
Hacktribe firmware patcher.
https://github.com/bangcorrupt/hacktribe
Source file hash : 1d0f0689d5a12c8a8bde9f821f2a59adc5f6cd6012ddb201ebb192b72468a646
Electribe 2 Sampler firmware version 2.02 found.
Patching firmware for Electribe 2 Sampler...
Target file hash : 42aca7cd6451e82628f3af7aa3e9361496b658aea6369a26a8d744cbf17bba7e
Destination file hash : 42aca7cd6451e82628f3af7aa3e9361496b658aea6369a26a8d744cbf17bba7e
Firmware patched successfully.
Copy 'hacked-SYSTEM.VSB' to 'SD:/KORG/electribe sampler/System/SYSTEM.VSB' and update firmware.
Alternatively, apply the patch manually:
sha256sum -c hash/SYSTEM.VSB.sha
bspatch SYSTEM.VSB hacked-SYSTEM.VSB patch/hacktribe-2.patch
sha256sum -c hash/hacked-SYSTEM.VSB.sha
Make sure both checksums match, otherwise you get a brick. <-- That's important.
^^ That's really important. ^^
You should see:
SYSTEM.VSB: OK
hacked-SYSTEM.VSB: OK
Edit header (only if installing on e2 synth):
python scripts/e2-header.py hacked-SYSTEM.VSB
Optionally, set custom init pattern:
python scripts/e2s-init-pat.py hacked-SYSTEM.VSB your-init-pattern.e2spat
Move hacked-SYSTEM.VSB
to SD card System
directory and rename to SYSTEM.VSB
.
Remove e2sSample.all
from Sample
directory, if present.
Follow the usual firmware update procedure and reboot.
Create the directory KORG/hacktribe/Sample
on the SD card.
Export all samples and reboot again.
Edit any existing e2sSample.all files to start at slot >=501 to prevent memory errors.
Add factory samples from e2 sampler:
Install factory sampler firmware to sampler hardware (black or red).
Boot without an SD card.
Insert SD card and export all samples.
Use a computer to edit the e2sSample.all file so the first sample is in slot 501.
Install hacktribe, boot and import edited e2sSample.all.