forked from letscontrolit/ESPEasy
-
Notifications
You must be signed in to change notification settings - Fork 0
/
_P028_BME280.ino
431 lines (361 loc) · 15.2 KB
/
_P028_BME280.ino
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
//#######################################################################################################
//#################### Plugin 028 BME280 I2C Temp/Hum/Barometric Pressure Sensor #######################
//#######################################################################################################
#define PLUGIN_028
#define PLUGIN_ID_028 28
#define PLUGIN_NAME_028 "Temperature & Humidity & Pressure - BME280"
#define PLUGIN_VALUENAME1_028 "Temperature"
#define PLUGIN_VALUENAME2_028 "Humidity"
#define PLUGIN_VALUENAME3_028 "Pressure"
enum
{
BME280_REGISTER_DIG_T1 = 0x88,
BME280_REGISTER_DIG_T2 = 0x8A,
BME280_REGISTER_DIG_T3 = 0x8C,
BME280_REGISTER_DIG_P1 = 0x8E,
BME280_REGISTER_DIG_P2 = 0x90,
BME280_REGISTER_DIG_P3 = 0x92,
BME280_REGISTER_DIG_P4 = 0x94,
BME280_REGISTER_DIG_P5 = 0x96,
BME280_REGISTER_DIG_P6 = 0x98,
BME280_REGISTER_DIG_P7 = 0x9A,
BME280_REGISTER_DIG_P8 = 0x9C,
BME280_REGISTER_DIG_P9 = 0x9E,
BME280_REGISTER_DIG_H1 = 0xA1,
BME280_REGISTER_DIG_H2 = 0xE1,
BME280_REGISTER_DIG_H3 = 0xE3,
BME280_REGISTER_DIG_H4 = 0xE4,
BME280_REGISTER_DIG_H5 = 0xE5,
BME280_REGISTER_DIG_H6 = 0xE7,
BME280_REGISTER_CHIPID = 0xD0,
BME280_REGISTER_VERSION = 0xD1,
BME280_REGISTER_SOFTRESET = 0xE0,
BME280_REGISTER_CAL26 = 0xE1, // R calibration stored in 0xE1-0xF0
BME280_REGISTER_CONTROLHUMID = 0xF2,
BME280_REGISTER_CONTROL = 0xF4,
BME280_REGISTER_CONFIG = 0xF5,
BME280_REGISTER_PRESSUREDATA = 0xF7,
BME280_REGISTER_TEMPDATA = 0xFA,
BME280_REGISTER_HUMIDDATA = 0xFD,
BME280_CONTROL_SETTING = 0x57, // Oversampling: 16x P, 2x T, normal mode
};
typedef struct
{
uint16_t dig_T1;
int16_t dig_T2;
int16_t dig_T3;
uint16_t dig_P1;
int16_t dig_P2;
int16_t dig_P3;
int16_t dig_P4;
int16_t dig_P5;
int16_t dig_P6;
int16_t dig_P7;
int16_t dig_P8;
int16_t dig_P9;
uint8_t dig_H1;
int16_t dig_H2;
uint8_t dig_H3;
int16_t dig_H4;
int16_t dig_H5;
int8_t dig_H6;
} bme280_calib_data;
bme280_calib_data _bme280_calib[2];
uint8_t _i2caddr;
int32_t _sensorID;
int32_t t_fine;
uint8_t Plugin_028_read8(byte reg, bool * is_ok = NULL); // Declaration
boolean Plugin_028_init[2] = {false, false};
boolean Plugin_028(byte function, struct EventStruct *event, String& string)
{
boolean success = false;
switch (function)
{
case PLUGIN_DEVICE_ADD:
{
Device[++deviceCount].Number = PLUGIN_ID_028;
Device[deviceCount].Type = DEVICE_TYPE_I2C;
Device[deviceCount].VType = SENSOR_TYPE_TEMP_HUM_BARO;
Device[deviceCount].Ports = 0;
Device[deviceCount].PullUpOption = false;
Device[deviceCount].InverseLogicOption = false;
Device[deviceCount].FormulaOption = true;
Device[deviceCount].ValueCount = 3;
Device[deviceCount].SendDataOption = true;
Device[deviceCount].TimerOption = true;
Device[deviceCount].GlobalSyncOption = true;
break;
}
case PLUGIN_GET_DEVICENAME:
{
string = F(PLUGIN_NAME_028);
break;
}
case PLUGIN_GET_DEVICEVALUENAMES:
{
strcpy_P(ExtraTaskSettings.TaskDeviceValueNames[0], PSTR(PLUGIN_VALUENAME1_028));
strcpy_P(ExtraTaskSettings.TaskDeviceValueNames[1], PSTR(PLUGIN_VALUENAME2_028));
strcpy_P(ExtraTaskSettings.TaskDeviceValueNames[2], PSTR(PLUGIN_VALUENAME3_028));
break;
}
case PLUGIN_WEBFORM_LOAD:
{
byte choice = Settings.TaskDevicePluginConfig[event->TaskIndex][0];
String options[2];
options[0] = F("0x76 - default settings (SDO Low)");
options[1] = F("0x77 - alternate settings (SDO HIGH)");
int optionValues[2];
optionValues[0] = 0x76;
optionValues[1] = 0x77;
string += F("<TR><TD>I2C Address:<TD><select name='plugin_028_bme280_i2c'>");
for (byte x = 0; x < 2; x++)
{
string += F("<option value='");
string += optionValues[x];
string += "'";
if (choice == optionValues[x])
string += F(" selected");
string += ">";
string += options[x];
string += F("</option>");
}
string += F("</select>");
success = true;
break;
}
case PLUGIN_WEBFORM_SAVE:
{
String plugin1 = WebServer.arg("plugin_028_bme280_i2c");
Settings.TaskDevicePluginConfig[event->TaskIndex][0] = plugin1.toInt();
success = true;
break;
}
case PLUGIN_READ:
{
uint8_t idx = Settings.TaskDevicePluginConfig[event->TaskIndex][0] & 0x1; //Addresses are 0x76 and 0x77 so we may use it this way
Plugin_028_init[idx] &= Plugin_028_check(Settings.TaskDevicePluginConfig[event->TaskIndex][0]); // Check id device is present
Plugin_028_init[idx] &= (Plugin_028_read8(BME280_REGISTER_CONTROL) == BME280_CONTROL_SETTING); // Check if the coefficients are still valid
if (!Plugin_028_init[idx])
{
Plugin_028_init[idx] = Plugin_028_begin(Settings.TaskDevicePluginConfig[event->TaskIndex][0]);
delay(65); //May be needed here as well to fix first wrong measurement?
}
if (Plugin_028_init[idx])
{
UserVar[event->BaseVarIndex] = Plugin_028_readTemperature(idx);
UserVar[event->BaseVarIndex + 1] = ((float)Plugin_028_readHumidity(idx));
UserVar[event->BaseVarIndex + 2] = ((float)Plugin_028_readPressure(idx)) / 100;
String log = F("BME : Address: 0x");
log += String(_i2caddr,HEX);
addLog(LOG_LEVEL_INFO, log);
log = F("BME : Temperature: ");
log += UserVar[event->BaseVarIndex];
addLog(LOG_LEVEL_INFO, log);
log = F("BME : Humidity: ");
log += UserVar[event->BaseVarIndex + 1];
addLog(LOG_LEVEL_INFO, log);
log = F("BME : Barometric Pressure: ");
log += UserVar[event->BaseVarIndex + 2];
addLog(LOG_LEVEL_INFO, log);
success = true;
}
break;
}
}
return success;
}
//**************************************************************************/
// Check BME280 presence
//**************************************************************************/
bool Plugin_028_check(uint8_t a) {
_i2caddr = a;
bool wire_status = false;
if (Plugin_028_read8(BME280_REGISTER_CHIPID, &wire_status) != 0x60) {
return false;
} else {
return wire_status;
}
}
//**************************************************************************/
// Initialize BME280
//**************************************************************************/
bool Plugin_028_begin(uint8_t a) {
_i2caddr = a;
if (! Plugin_028_check(a))
return false;
Plugin_028_readCoefficients(_i2caddr & 0x01);
Plugin_028_write8(BME280_REGISTER_CONTROLHUMID, 0x03);
Plugin_028_write8(BME280_REGISTER_CONTROL, BME280_CONTROL_SETTING);
return true;
}
//**************************************************************************/
// Writes an 8 bit value over I2C/SPI
//**************************************************************************/
void Plugin_028_write8(byte reg, byte value)
{
Wire.beginTransmission((uint8_t)_i2caddr);
Wire.write((uint8_t)reg);
Wire.write((uint8_t)value);
Wire.endTransmission();
}
//**************************************************************************/
// Reads an 8 bit value over I2C
//**************************************************************************/
uint8_t Plugin_028_read8(byte reg, bool * is_ok)
{
uint8_t value;
Wire.beginTransmission((uint8_t)_i2caddr);
Wire.write((uint8_t)reg);
Wire.endTransmission();
byte count = Wire.requestFrom((uint8_t)_i2caddr, (byte)1);
if (is_ok != NULL) { *is_ok = (count == 1); }
value = Wire.read();
Wire.endTransmission();
return value;
}
//**************************************************************************/
// Reads a 16 bit value over I2C
//**************************************************************************/
uint16_t Plugin_028_read16(byte reg)
{
uint16_t value;
Wire.beginTransmission((uint8_t)_i2caddr);
Wire.write((uint8_t)reg);
Wire.endTransmission();
Wire.requestFrom((uint8_t)_i2caddr, (byte)2);
value = (Wire.read() << 8) | Wire.read();
Wire.endTransmission();
return value;
}
//**************************************************************************/
// Reads a 24 bit value over I2C
//**************************************************************************/
int32_t Plugin_028_read24(byte reg)
{
int32_t value;
Wire.beginTransmission((uint8_t)_i2caddr);
Wire.write((uint8_t)reg);
Wire.endTransmission();
Wire.requestFrom((uint8_t)_i2caddr, (byte)3);
value = (((int32_t)Wire.read()) << 16) | (Wire.read() << 8) | Wire.read();
Wire.endTransmission();
return value;
}
//**************************************************************************/
// Reads a 16 bit value over I2C
//**************************************************************************/
uint16_t Plugin_028_read16_LE(byte reg) {
uint16_t temp = Plugin_028_read16(reg);
return (temp >> 8) | (temp << 8);
}
//**************************************************************************/
// Reads a signed 16 bit value over I2C
//**************************************************************************/
int16_t Plugin_028_readS16(byte reg)
{
return (int16_t)Plugin_028_read16(reg);
}
int16_t Plugin_028_readS16_LE(byte reg)
{
return (int16_t)Plugin_028_read16_LE(reg);
}
//**************************************************************************/
// Reads the factory-set coefficients
//**************************************************************************/
void Plugin_028_readCoefficients(uint8_t idx)
{
_bme280_calib[idx].dig_T1 = Plugin_028_read16_LE(BME280_REGISTER_DIG_T1);
_bme280_calib[idx].dig_T2 = Plugin_028_readS16_LE(BME280_REGISTER_DIG_T2);
_bme280_calib[idx].dig_T3 = Plugin_028_readS16_LE(BME280_REGISTER_DIG_T3);
_bme280_calib[idx].dig_P1 = Plugin_028_read16_LE(BME280_REGISTER_DIG_P1);
_bme280_calib[idx].dig_P2 = Plugin_028_readS16_LE(BME280_REGISTER_DIG_P2);
_bme280_calib[idx].dig_P3 = Plugin_028_readS16_LE(BME280_REGISTER_DIG_P3);
_bme280_calib[idx].dig_P4 = Plugin_028_readS16_LE(BME280_REGISTER_DIG_P4);
_bme280_calib[idx].dig_P5 = Plugin_028_readS16_LE(BME280_REGISTER_DIG_P5);
_bme280_calib[idx].dig_P6 = Plugin_028_readS16_LE(BME280_REGISTER_DIG_P6);
_bme280_calib[idx].dig_P7 = Plugin_028_readS16_LE(BME280_REGISTER_DIG_P7);
_bme280_calib[idx].dig_P8 = Plugin_028_readS16_LE(BME280_REGISTER_DIG_P8);
_bme280_calib[idx].dig_P9 = Plugin_028_readS16_LE(BME280_REGISTER_DIG_P9);
_bme280_calib[idx].dig_H1 = Plugin_028_read8(BME280_REGISTER_DIG_H1);
_bme280_calib[idx].dig_H2 = Plugin_028_readS16_LE(BME280_REGISTER_DIG_H2);
_bme280_calib[idx].dig_H3 = Plugin_028_read8(BME280_REGISTER_DIG_H3);
_bme280_calib[idx].dig_H4 = (Plugin_028_read8(BME280_REGISTER_DIG_H4) << 4) | (Plugin_028_read8(BME280_REGISTER_DIG_H4 + 1) & 0xF);
_bme280_calib[idx].dig_H5 = (Plugin_028_read8(BME280_REGISTER_DIG_H5 + 1) << 4) | (Plugin_028_read8(BME280_REGISTER_DIG_H5) >> 4);
_bme280_calib[idx].dig_H6 = (int8_t)Plugin_028_read8(BME280_REGISTER_DIG_H6);
}
//**************************************************************************/
// Read temperature
//**************************************************************************/
float Plugin_028_readTemperature(uint8_t idx)
{
int32_t var1, var2;
int32_t adc_T = Plugin_028_read24(BME280_REGISTER_TEMPDATA);
adc_T >>= 4;
var1 = ((((adc_T >> 3) - ((int32_t)_bme280_calib[idx].dig_T1 << 1))) *
((int32_t)_bme280_calib[idx].dig_T2)) >> 11;
var2 = (((((adc_T >> 4) - ((int32_t)_bme280_calib[idx].dig_T1)) *
((adc_T >> 4) - ((int32_t)_bme280_calib[idx].dig_T1))) >> 12) *
((int32_t)_bme280_calib[idx].dig_T3)) >> 14;
t_fine = var1 + var2;
float T = (t_fine * 5 + 128) >> 8;
return T / 100;
}
//**************************************************************************/
// Read pressure
//**************************************************************************/
float Plugin_028_readPressure(uint8_t idx) {
int64_t var1, var2, p;
int32_t adc_P = Plugin_028_read24(BME280_REGISTER_PRESSUREDATA);
adc_P >>= 4;
var1 = ((int64_t)t_fine) - 128000;
var2 = var1 * var1 * (int64_t)_bme280_calib[idx].dig_P6;
var2 = var2 + ((var1 * (int64_t)_bme280_calib[idx].dig_P5) << 17);
var2 = var2 + (((int64_t)_bme280_calib[idx].dig_P4) << 35);
var1 = ((var1 * var1 * (int64_t)_bme280_calib[idx].dig_P3) >> 8) +
((var1 * (int64_t)_bme280_calib[idx].dig_P2) << 12);
var1 = (((((int64_t)1) << 47) + var1)) * ((int64_t)_bme280_calib[idx].dig_P1) >> 33;
if (var1 == 0) {
return 0; // avoid exception caused by division by zero
}
p = 1048576 - adc_P;
p = (((p << 31) - var2) * 3125) / var1;
var1 = (((int64_t)_bme280_calib[idx].dig_P9) * (p >> 13) * (p >> 13)) >> 25;
var2 = (((int64_t)_bme280_calib[idx].dig_P8) * p) >> 19;
p = ((p + var1 + var2) >> 8) + (((int64_t)_bme280_calib[idx].dig_P7) << 4);
return (float)p / 256;
}
//**************************************************************************/
// Read humidity
//**************************************************************************/
float Plugin_028_readHumidity(uint8_t idx) {
int32_t adc_H = Plugin_028_read16(BME280_REGISTER_HUMIDDATA);
int32_t v_x1_u32r;
v_x1_u32r = (t_fine - ((int32_t)76800));
v_x1_u32r = (((((adc_H << 14) - (((int32_t)_bme280_calib[idx].dig_H4) << 20) -
(((int32_t)_bme280_calib[idx].dig_H5) * v_x1_u32r)) + ((int32_t)16384)) >> 15) *
(((((((v_x1_u32r * ((int32_t)_bme280_calib[idx].dig_H6)) >> 10) *
(((v_x1_u32r * ((int32_t)_bme280_calib[idx].dig_H3)) >> 11) + ((int32_t)32768))) >> 10) +
((int32_t)2097152)) * ((int32_t)_bme280_calib[idx].dig_H2) + 8192) >> 14));
v_x1_u32r = (v_x1_u32r - (((((v_x1_u32r >> 15) * (v_x1_u32r >> 15)) >> 7) *
((int32_t)_bme280_calib[idx].dig_H1)) >> 4));
v_x1_u32r = (v_x1_u32r < 0) ? 0 : v_x1_u32r;
v_x1_u32r = (v_x1_u32r > 419430400) ? 419430400 : v_x1_u32r;
float h = (v_x1_u32r >> 12);
return h / 1024.0;
}
//**************************************************************************/
// Calculates the altitude (in meters) from the specified atmospheric
// pressure (in hPa), and sea-level pressure (in hPa).
// @param seaLevel Sea-level pressure in hPa
// @param atmospheric Atmospheric pressure in hPa
//**************************************************************************/
float Plugin_028_readAltitude(float seaLevel)
{
// Equation taken from BMP180 datasheet (page 16):
// http://www.adafruit.com/datasheets/BST-BMP180-DS000-09.pdf
// Note that using the equation from wikipedia can give bad results
// at high altitude. See this thread for more information:
// http://forums.adafruit.com/viewtopic.php?f=22&t=58064
float atmospheric = Plugin_028_readPressure(_i2caddr & 0x01) / 100.0F;
return 44330.0 * (1.0 - pow(atmospheric / seaLevel, 0.1903));
}