From 5f30e702386faa0a83b9fdecd176914ad0d4315b Mon Sep 17 00:00:00 2001 From: Olexii Bulhakov <110279020+bulhakovolexii@users.noreply.github.com> Date: Fri, 26 Jan 2024 17:12:36 +0200 Subject: [PATCH] [PUBLISHER] Merge #94 * PUSH NOTE : transmission.md * PUSH NOTE : calculation-method.md --- docs/calculation-method/transmission/index.md | 7 ++++++- 1 file changed, 6 insertions(+), 1 deletion(-) diff --git a/docs/calculation-method/transmission/index.md b/docs/calculation-method/transmission/index.md index d059495..b4537fe 100644 --- a/docs/calculation-method/transmission/index.md +++ b/docs/calculation-method/transmission/index.md @@ -144,7 +144,12 @@ $U_{op}$ що враховує вплив теплопровідних вклю | 0,4 ≤ $U_{op}$ < 0,8 | 0,05 | | $U_{op}$ < 0,4 | 0,10 | -$$R_{∑}=\frac{1}{h_{si}}+\displaystyle\sum_{i=1}^IR_i+\frac{1}{h_{se}}=\frac{1}{h_{si}}+\displaystyle\sum_{i=1}^I\frac{d_i}{\lambda_{ip}}+\frac{1}{h_{se}}\tag{7},$$ +$$ +\begin{aligned} +&R_{∑}=\frac{1}{h_{si}}+\displaystyle\sum_{i=1}^IR_i+\frac{1}{h_{se}}=\\\ +&=\frac{1}{h_{si}}+\displaystyle\sum_{i=1}^I\frac{d_i}{\lambda_{ip}}+\frac{1}{h_{se}}\tag{7}, +\end{aligned} +$$ де $h_{si}$, $h_{se}$ — коефіцієнти теплообміну внутрішньої і зовнішньої поверхонь огороджувальної конструкції, Вт/(м²·К), які приймають згідно з [таблицею 3.2.2](index.md#322-розрахункові-значення-коефіцієнтів-теплопередачі-внутрішньої-h_si-та-зовнішньої-h_se-поверхонь-огороджувальних-конструкцій)[^3]; $R_i$ — тепловий опір $i$-го шару конструкції, м²·К/Вт;