forked from EVerest/everest-core
-
Notifications
You must be signed in to change notification settings - Fork 3
/
config-sil-energy-management.yaml
223 lines (223 loc) · 5.8 KB
/
config-sil-energy-management.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
active_modules:
iso15118_charger:
module: EvseV2G
config_module:
device: auto
tls_security: allow
connections:
security:
- module_id: evse_security
implementation_id: main
iso15118_car:
module: PyEvJosev
config_module:
device: auto
supported_ISO15118_2: true
evse_manager_1:
module: EvseManager
mapping:
module:
evse: 1
config_module:
connector_id: 1
evse_id: DE*PNX*E12345*1
session_logging: true
session_logging_xml: false
session_logging_path: /tmp
ac_hlc_enabled: true
ac_hlc_use_5percent: false
ac_enforce_hlc: false
request_zero_power_in_idle: false
uk_smartcharging_random_delay_at_any_change: false
uk_smartcharging_random_delay_max_duration: 100
uk_smartcharging_random_delay_enable: true
connections:
bsp:
- module_id: yeti_driver_1
implementation_id: board_support
powermeter_grid_side:
- module_id: yeti_driver_1
implementation_id: powermeter
slac:
- module_id: slac
implementation_id: evse
hlc:
- module_id: iso15118_charger
implementation_id: charger
evse_manager_2:
module: EvseManager
mapping:
module:
evse: 2
config_module:
connector_id: 2
evse_id: DE*PNX*E12345*2
session_logging: true
session_logging_xml: false
session_logging_path: /tmp
ac_hlc_enabled: false
ac_hlc_use_5percent: false
ac_enforce_hlc: false
connections:
bsp:
- module_id: yeti_driver_2
implementation_id: board_support
powermeter_grid_side:
- module_id: yeti_driver_2
implementation_id: powermeter
yeti_driver_1:
module: JsYetiSimulator
config_module:
connector_id: 1
yeti_driver_2:
module: JsYetiSimulator
config_module:
connector_id: 2
slac:
module: SlacSimulator
ev_manager_1:
module: EvManager
config_module:
connector_id: 1
auto_enable: true
auto_exec: false
auto_exec_commands: sleep 1;iec_wait_pwr_ready;sleep 1;draw_power_regulated 16,3;sleep 30;unplug
connections:
ev_board_support:
- module_id: yeti_driver_1
implementation_id: ev_board_support
ev:
- module_id: iso15118_car
implementation_id: ev
slac:
- module_id: slac
implementation_id: ev
ev_manager_2:
module: EvManager
config_module:
connector_id: 2
auto_enable: true
auto_exec: false
connections:
ev_board_support:
- module_id: yeti_driver_2
implementation_id: ev_board_support
auth:
module: Auth
config_module:
connection_timeout: 10
selection_algorithm: PlugEvents
connections:
token_provider:
- module_id: token_provider_1
implementation_id: main
- module_id: token_provider_2
implementation_id: main
token_validator:
- module_id: token_validator
implementation_id: main
evse_manager:
- module_id: evse_manager_1
implementation_id: evse
- module_id: evse_manager_2
implementation_id: evse
evse_security:
module: EvseSecurity
config_module:
private_key_password: "123456"
token_provider_1:
module: DummyTokenProvider
config_implementation:
main:
token: TOKEN1
connections:
evse:
- module_id: evse_manager_1
implementation_id: evse
token_provider_2:
module: DummyTokenProvider
connections:
evse:
- module_id: evse_manager_2
implementation_id: evse
token_validator:
module: DummyTokenValidator
config_implementation:
main:
validation_result: Accepted
validation_reason: Token seems valid
sleep: 0.25
energy_manager:
module: EnergyManager
config_module:
schedule_total_duration: 2
schedule_interval_duration: 15
debug: false
connections:
energy_trunk:
- module_id: grid_connection_point
implementation_id: energy_grid
grid_connection_point:
module: EnergyNode
config_module:
fuse_limit_A: 20.0
phase_count: 3
connections:
price_information: []
energy_consumer:
- module_id: evse_manager_1_sink
implementation_id: energy_grid
- module_id: evse_manager_2_sink
implementation_id: energy_grid
powermeter:
- module_id: yeti_driver_1
implementation_id: powermeter
evse_manager_1_sink:
module: EnergyNode
mapping:
module:
evse: 1
config_module:
fuse_limit_A: 32.0
phase_count: 3
connections:
energy_consumer:
- module_id: evse_manager_1
implementation_id: energy_grid
evse_manager_2_sink:
module: EnergyNode
mapping:
module:
evse: 2
config_module:
fuse_limit_A: 32.0
phase_count: 3
connections:
energy_consumer:
- module_id: evse_manager_2
implementation_id: energy_grid
api:
module: API
connections:
evse_manager:
- module_id: evse_manager_1
implementation_id: evse
- module_id: evse_manager_2
implementation_id: evse
random_delay:
- module_id: evse_manager_1
implementation_id: random_delay
error_history:
- module_id: error_history
implementation_id: error_history
evse_energy_sink:
- module_id: evse_manager_1_sink
implementation_id: external_limits
- module_id: evse_manager_2_sink
implementation_id: external_limits
error_history:
module: ErrorHistory
config_implementation:
error_history:
database_path: /tmp/error_history.db
x-module-layout: {}