Releases: cms-gem-daq-project/OptoHybridv3
3.2.8.X
GE1/1 Long:
- Documentation: oh_registers_3.2.8.1C.pdf
- Firmware: OH_3.2.8.1C.tar.gz
GE1/1 Short:
- Documentation: oh_registers_3.2.8.C.pdf
- Firmware: OH_3.2.8.C.tar.gz
3.2.7.X
GE1/1 Long:
- Documentation: oh_registers_3.2.7.1C.pdf
- Firmware: OH_3.2.7.1C.tar.gz
GE1/1 Short:
- Documentation:
oh_registers_3.2.7.C.pdf - Firmware: OH_3.2.7.C.tar.gz
GE2/1:
- Documentation:
- Firmware:
GBTX 0 should still use the updated configuration, in the doc/gbtx_configurations path. A link is provided here:
3.2.6.X
GE1/1 Long:
- Documentation: oh_registers_3.2.6.1C.pdf
- Firmware: OH_3.2.6.1C.tar.gz
GE1/1 Short:
- Documentation: oh_registers_3.2.6.C.pdf
- Firmware: OH_3.2.6.C.tar.gz
GE2/1:
- Documentation: oh_registers_3.2.6.2A.pdf
- Firmware: OH_3.2.6.2A.tar.gz
GBTX 0 should use the updated configuration, in the doc/gbtx_configurations path. A link is provided here:
3.2.4.X
Fix a bug in the startup reset of the firmware.
GE1/1 Long:
- Documentation: oh_registers_3.2.4.1C.pdf
- Firmware: OH_3.2.4.1C.tar.gz
GE1/1 Short:
- Documentation: oh_registers_3.2.4.C.pdf
- Firmware: OH_3.2.4.C.tar.gz
GE2/1:
- Documentation: oh_registers_3.2.4.2A.pdf
- Firmware: OH_3.2.4.2A.tar.gz
3.2.3.X
This release fixes the trigger links of both GE1/1 and GE2/1
GE1/1 Long:
- Documentation: oh_registers_3.2.3.1C.pdf
- Firmware (alpha): OH_3.2.3.1C-alpha.tar.gz
- Firmware (final): OH_3.2.3.1C.tar.gz
- Firmware (correctly inverted partitions): OH_3.2.3.1C_inverted.tar.gz
GE1/1 Short:
- Documentation: oh_registers_3.2.3.C.pdf
- Firmware: OH_3.2.3.C.tar.gz
- Firmware (correctly inverted partitions): OH_3.2.3.C_inverted.tar.gz
GE2/1:
- Documentation: oh_registers_3.2.3.2A.pdf
- Firmware: OH_3.2.3.2A.tar.gz
NOTE: the currently uploaded "alpha" binary was compiled yesterday and has some very minor differences.. including the date... an updated version is uploaded also.. for all uses they should be functionally identical but the "final" release will be more canonically correct (having e.g. the right date as the commit, etc) but it is currently untested
3.2.2.X
Version 3.2.2 should fix issues with the GE2/1 trigger links
Also adds two new features
- S-bit monitor
- High multiplicity occupancy counter for all channels fired investigations
Note that any >=3.2 GE1/1 firmware releases require special CTP7 firmware (not yet created)
GE2/1:
- Firmware: OH_3.2.2.2A.tar.gz
- Source: https://github.com/cms-gem-daq-project/OptoHybridv3/releases/tag/3.2.2.2A
GE1/1 v3c Long:
- Firmware: not generated
- Source: https://github.com/cms-gem-daq-project/OptoHybridv3/releases/tag/3.2.2.1C
GE1/1 v3c Short:
- Firmware: not generated
- Source: not generated
3.1.5.C
Invert Tap Delays by 0-->23 changed to 23-->0; generation script corr…
3.1.5.1C
This release should correct the tap delays for the v3c LONG geb. The same correction should be applied if wanting to use the short GEB correctly as well.
It was found that the VFAT numbering inversion scripts incorrectly applied the Tap delays to the VFAT trigger inputs.
3.1.4.1C
Update trigger timing to v3c long; small fix to gbt link ready logic …
3.1.3.B
Add trigger link reset monitor
- Add pulsing gbt_lock led
- Add s-bits mux readout from ipbus
- Add trigger counter pulser
- Add trigger link monitor registers
- Fix bug in trigger counter
- Increase # of good frames needed for SOT ready
- Added flipflops for ipb_mosi inputs in the ipbus_slave.vhd (duplicated from ctp7)
- Add alternative gbt_rx sync character