You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Provides power/energy reporting for models that support it. The GE/Jasco Zigbee switches and dimmers have little to no configuration options. There's no reason this driver shouldn't work for devices besides the GE/Jasco models (I have two plug-in switches from other manufacturers using it), though other models may have better configuration options that a specifically-tailored driver could take advantage of. The LED indicators don't even seem to be configurable by Zigbee, though I've seen that they can be changed with a sequence of quick button taps (up x3 followed by down x1).
Switch (Jasco 45856)
Basic functionality with properly scaled power/energy metering.
Dimmer (Jasco 45857)
The following options are available for configuration in the settings menu:
Default Dim Level - The default dimming level when the device is turned on (a tap on the physical switch or an ON command from the hub). A value of 0 restores the dimmer to the previous level when the switch was last on. Values from 1-100% will scale based on the minimum and maximum dimming settings. This is the only configurable option that I've found that is stored in the device - all other settings are programmatic and will apply only to commands originating from the hub.
Dimming Transition Time - The time in tenths of seconds to transition to a new level when a set level command is sent. Values can range from instant (0) to 1 hour 49 minutes 13.4 seconds (65534). A setting of 65535 uses the default transition time configured in the dimmer hardware, which for the 45857 is instant. This setting applies only to commands originating from the hub.
Transition Time Scaling - Enabling this setting will use the Dimming Transition Time as the time to move from 0 to 100%, and will scale any smaller change to take a proportional amount of time. For example, if the Dimming Transition Time is set to 10 minutes and the level is changed from 25 to 75% (a 50% change), the transition will take 5 minutes. This setting does not apply if the Dimming Transition Time is set to 65535. This setting applies only to commands originating from the hub.
Maximum and Minimum Dim Level - Configurable maximum and minimum dimming levels. The device uses dimming levels of 0 to 255 instead of the 0 to 100% displayed in the app. In order to provide greater granularity in setting these limits to match the performance of your light bulbs, these settings use the 0 to 255 values native to the hardware. This setting applies only to commands originating from the hub. Note that, if the physical buttons are used to dim below the minimum level, the app will show a dim level of 0 and the switch in the ON state. A minimum dim level that is set greater than the maximum dim level will be ignored, with 0 being used as the minimum instead.
GE Z-Wave Motion Switch/Dimmer (ge-zwave-motion-switch)
Adds custom capabilities to control configuration parameters on motion switch/dimmer:
Operating Mode (Occupancy/Vacancy/Manual)
Light Sensing (On/Off)
Motion Sensor Sensitivity (High/Medium/Low)
Light Duration After Motion Stops (5s/1m/5m/15m/30m)
Default Dim Level (0=Previous/1-100%)
In-Wall Motion Switches
Fingerprint
Device
Profile
0063/494D/3031
GE Smart Motion Sensor Switch (24770 / ZW4006)
ge-motionswitch-assoc
0063/494D/3032
GE Smart Motion Sensor Switch (26931 / ZW4006)
ge-motionswitch-assoc
In-Wall Motion Dimmers
Fingerprint
Device
Profile
0063/494D/3033
GE Smart Motion Sensor Switch (26932)
ge-motiondimmer-assoc
0063/494D/3034
GE Smart Motion Sensor Switch (26933)
ge-motiondimmer-assoc
GE Z-Wave Switch/Dimmer/Fan/Outlet (ge-zwave-switch)
Profiles:
ge-________-legacy
Configuration parameters available in settings
ge-________-assoc
Configuration parameters available in settings
Association groups 2 and 3 available in settings
Hub added to association group 3 to support double tap (does not apply to motion switch/dimmer)