Modbus Adapter for IoT Plug and Play bridge

This a README for the Modbus adapter on the IoT Plug and Play bridge

Table of Contents

Adapter Configuration

The adapter configuration follows the format defined by Modbus Gateway configruation interface, an Azure Digital Twin (IoT Plug and Play) Interface. Follow the steps below to update config.json to add a Modbus device to IoT Plug and Play bridge.

  1. Open config.json for the IoT Plug and Play bridge.
  2. Add the following json payload to pnp_bridge_interface_components.
  3. Add any supported modbus interface configurations into the pnp_bridge_adapter_global_configs dictionary with a key that an interface component can use as modbus_identity under pnp_bridge_adapter_config. More information in the PnP Bridge Adapter Global Configs section.
  4. Modify rtu or tcp and modbus_identity parameters under pnp_bridge_adapter_config to match your Modbus device configuration. Refer to following sections for more detailed descriptions of each field in these JSON objects. "DL679" is the name of the interface configuration that the Modbus Adapter supports, and that the device corresponding to the interface component specifying it, uses to interact with the adapter.
{
    "pnp_bridge_interface_components": [
      {
          "_comment": "Component - Modbus Device",
          "pnp_bridge_interface_id": "urn:contoso:com:Co2Detector:1",
          "pnp_bridge_component_name": "ModbusComponent",
          "pnp_bridge_adapter_id": "modbus-pnp-interface",
          "pnp_bridge_adapter_config": {
              "unit_id": 1,
              "rtu": {
                "port": "COM5",
                "baudRate": "9600",
                "dataBits": 8,
                "stopBits": "ONE",
                "parity": "NONE"
              },
              "tcp": null,
              "modbus_identity": "DL679"
          }
      }
    ]
}

PnP Bridge Adapter Config

pnp_bridge_adapter_config provides the physical connection information between the Modbus gateway and the Modbus edge devices. This part of configuration provides TCP/IP or serial connection information (must pick either one). You may provide null value for the connection you do not use.

{
    "pnp_bridge_adapter_config": {
    "unitId": 1,
    "rtu": null,
    "tcp": {
        "host": "192.168.1.111",
        "port": 502
       }
    }
}

Configuration Definition:

Field Data Type Description
unitId integer The id (or slave address) of the Modbus device
rtu
port integer Serial port name, ex: "/dev/ttys0" or "COM1".
baudRate string Baud rate of the serial port. Valid values: ..."9600", "14400", "19200"...
dataBits integer Data Bit for the serial port. Valid values: 7 and 8.
stopBits string Stop Bit used for the serial port. Valid values: "ONE", "TWO", "OnePointFive".
parity string Serial port parity. Valid values: "ODD", "EVEN", and "NONE".
tcp
host string Ipv4 address of the Modbus device
port integer Port number of the Modbus device

PnP Bridge Adapter Global Configs

PnP Bridge Adapter Global Configs provide PnP Bridge Adapters to optionally list supported interface configurations. These interface configurations are identified with a key that a Modbus interface component uses to identify how the adapter must parse data coming from the device. The data sheet of the physical device would usually outline this information. This sample configuration is based on the schema of a sample CO₂ detector.

{
    ,
    "pnp_bridge_adapter_global_configs": {
      "modbus-pnp-interface": {
          "DL679": {
              "telemetry": {
                  "co2": {
                      "startAddress": "40001",
                      "length": 1,
                      "dataType": "integer",
                      "defaultFrequency": 5000,
                      "conversionCoefficient": 1
                  },
                  "temperature": {
                      "startAddress": "40003",
                      "length": 1,
                      "dataType": "decimal",
                      "defaultFrequency": 5000,
                      "conversionCoefficient": 0.01
                  }
              },
              "properties": {
                  "firmwareVersion": {
                      "startAddress": "40482",
                      "length": 1,
                      "dataType": "hexstring",
                      "defaultFrequency": 60000,
                      "conversionCoefficient": 1,
                      "access": 1
                  },
                  "modelName": {
                      "startAddress": "40483",
                      "length": 2,
                      "dataType": "string",
                      "defaultFrequency": 60000,
                      "conversionCoefficient": 1,
                      "access": 1
                  },
                  "alarmStatus_co2": {
                      "startAddress": "00305",
                      "length": 1,
                      "dataType": "boolean",
                      "defaultFrequency": 1000,
                      "conversionCoefficient": 1,
                      "access": 1
                  },
                  "alarmThreshold_co2": {
                      "startAddress": "40225",
                      "length": 1,
                      "dataType": "integer",
                      "defaultFrequency": 30000,
                      "conversionCoefficient": 1,
                      "access": 2
                  }
              },
              "commands": {
                  "clearAlarm_co2": {
                      "startAddress": "00305",
                      "length": 1,
                      "dataType": "flag",
                      "conversionCoefficient": 1
                  }
              }
          }
      }
    }
}

Configuration Definition:

Field Data Type Description
Capability Definition
startAddress integer Starting address of the Modbus device to read from
length integer Number of bytes to read.
dataType string Data type that the raw Modbus response should convert to. Valid values: "integer", "decimal".
Experimental Data Types*:
"string": returns Modbus byte array as ASCII string.
"hexstring": return Modbus byte arry as hexadecimal string.
defaultFrequency integer For telemetry and property capability only. The time interval (in miliseconds) between each data pull from the Modbus device.
conversionCoefficient decimal The coefficient that the raw Modbus response should multiply to to get actual value. It is 1 by default.
Ex. If the raw response of the temperature (in Celcius) reading from the Modbus device is 0x0935 (=2357), we need to mutiply the raw data to 0.01 to get the actual value (23.57) in Celcius. 0.01 is the conversionCoefficient.
access integer For property capability only.
1 for read-only property
2 for writable property

* We understand that data type like "string" can be interpreted differently for each device manufacturer as Modbus does not provide a standard representation for "string". Please share your opnion on how these type of data should be generally converted

Reference

Modbus

A serial communication protocol that is commonly used in the industrial IoT world. This module supports two most common variants of the Modbus protocols: Modbus TCP/IP (communicates over TCP/IP networks) and Modbus RTU (communicates over RS485 connection).