Heater device

The heater device is a special implementation of a climate-component.

It sets the mode to heat or off depending on a threshold value and only supports target_temperature and current_temperature.

PLC-Datatype support for INT and REAL.

Options

  • *name: The name of the entity.
  • *target_temperature: PLCconf of the address with the target temperature.
  • current_temperature: PLCconf of the address holding the current temperature. This value is read-only by default.
  • min_temp: The minimal value which the Climate-Card should display.
  • max_temp: The maximal value which the Climate-Card should display.
  • heatMode_temperature_threshold: If the target_temperature is above this value, the mode should be set to heat, otherwise to off. For example, a target temperature of 4°C should display as off in Home Assistant
  • value_template: The Jinja template to transform the PCL value to Home Assistant. This template is used for current_temperature and target_temperature when defined.
  • current_temperature_template: Template for the current_temperature value.
  • temperature_command_template: Template for the target_temperature value.
  • temperature_command_template: The Jinja template to transform the setPoint temperature from Home Assistant to the PLC value.

Examples

devices:
  - name: Bath heater
    type: heater
    target_temperature: DB4,REAL0
    heatMode_temperature_threshold: 4 # Everything <= 7°C should be understood as heater=off
    min_temp: 4
    max_temp: 30
    current_temperature: DB4,REAL5

  - name: Bedroom heater
    type: heater
    target_temperature:
      plc: DB4,INT48
      update_interval: 5000
    temperature_command_template: "{{ (value * 10) | int }}" # PLC expects temp*10 like 225 for 22.5°C
    value_template: "{{ (value | float / 10) | round(2) }}"  # PLC provides 212 for 21.2°C
    heatMode_temperature_threshold: 70 # Everything <= 7°C should be understood as heater=off
    min_temp: 7
    max_temp: 30
    current_temperature:
      plc: DB4,INT50
      update_interval: 1000 # Update the current temperature every 1s  - name: Bedroom heater