add HV discharge circuit #5

Open
filipswit opened this issue Feb 6, 2025 · 2 comments
Open

add HV discharge circuit #5

filipswit opened this issue Feb 6, 2025 · 2 comments

Comments

@filipswit
Copy link
Collaborator

  • add HV discharge circuit?

Originally posted by @gkasprow in #1

Do you think about something like this. It is activated with negated HV_ON signal

Image

@gkasprow
Copy link
Contributor

gkasprow commented Feb 6, 2025

Yes but we would need transistor that withstands 6kV. You can use the last divider stage for fhat purpose

@gkasprow
Copy link
Contributor

gkasprow commented Feb 7, 2025

the discharge circuit can be connected to the first tap of the drift zone