Please provide a clear and concise description of your question or discussion topic.

Hi,yantosca
I made a simulation of PM2.5 concentration, and its aerosal-only mode,not full-chem mode,its a global scale, and I use the EDGAR global emission inventory,after the simulation, I find that the PM2.5 concentration distribution is wrong,I'm confused about it, the year of 2022 pm2.5 concentration is wrong, should I change the EDGAR emission inventory to the CEDS emission inventory? but I found that in the CEDS inventory , there is no PM2.5 species. I know that in the EDGAR inventory, the PM2.5 exist,so after the simulation, I can get the PM2.5 concentration, I wanna know that if I should change the EDGAR inventory to CEDS inventory, and if the CEDS inventory can get the PM2.5 concentration after the simulation. thanks a lot!

@rongbing0353 rongbing0353 added the category: Question Further information is requested label Jan 12, 2025
@yantosca yantosca added the topic: Aerosols Related to aerosol species in GEOS-Chem label Jan 13, 2025
@yantosca
Copy link
Contributor

Thanks for writing @rongbing0353. PM2.5 isn't a species in GEOS-Chem, but it is derived from diagnostic quantities. You should use the AerosolMass%PM25 diagnostic to get PM2.5.

CEDS is the default inventory in GEOS-Chem so I would suggest that you use this inventory.

@yantosca yantosca self-assigned this Jan 14, 2025
@yantosca yantosca added the topic: Emissions Related to emissions inventories used in GEOS-Chem label Jan 21, 2025