Skip to content

Latest commit

 

History

History

Tonality_Aures1985

Folders and files

NameName
Last commit message
Last commit date

parent directory

..
 
 
 
 
 
 

Tonality model from Aures: verification of the implementation in SQAT

The validation_signal_to_noise_ratio.m code is used to verify the implementation of the tonality model from Aures [1] (see Tonality_Aures1985 code here). The verification is performed considering the foloowing test signals:

  • Pure tone (center frequency $f_{\mathrm{c}}=1~\mathrm{kHz}$ and sound pressure level $L_{\mathrm{p}}=85~\mathrm{dB}~\mathrm{SPL}$) with different signal-to-noise ratios (SNRs) from narrowband noises (one-critical-band wide, bandwidth $\mathrm{BW}=1081-918.8 ~\mathrm{Hz}$).

How to use this code

In order to run this code and reproduce the figures available in the figs folder, the user needs to download the dataset of sound files from zenodo here. The obtained folder called validation_SQAT_v1_0 has to be included in the sound_files folder of the toolbox.

Results

The figures below compare the results obtained using the Tonality_Aures1985 implementation in SQAT with reference data from [2].

References

[1] Aures, W. (1985). Berechnungsverfahren für den sensorischen Wohlklang beliebiger Schallsignale (A model for calculating the sensory euphony of various sounds). Acta Acustica united with Acustica, 59(2), 130-141.

[2] Hastings, A., Lee, K. H., Davies, P., & Surprenant, A. M. (2003). Measurement of the attributes of complex tonal components commonly found in product sound. Noise Control Engineering Journal, 51(4), 195-209.

Log

This code was released in SQAT v1.0, 14.05.2023