diff --git a/docs/local-server.md b/docs/local-server.md
index f7196321..925117ff 100644
--- a/docs/local-server.md
+++ b/docs/local-server.md
@@ -30,15 +30,18 @@ You get the following response:
"pm10": 8,
"pm003Count": 442,
"atmp": 25.87,
+ "atmpCompensated": 24.47,
"rhum": 43,
+ "rhumCompensated": 49,
"tvocIndex": 100,
- "tvoc_raw": 33051,
+ "tvocRaw": 33051,
"noxIndex": 1,
- "nox_raw": 16307,
+ "noxRaw": 16307,
"boot": 6,
+ "bootCount": 6,
"ledMode": "pm",
- "firmwareVersion": "3.0.10beta",
- "fwMode": "I-9PSL"
+ "firmware": "3.1.3",
+ "model": "I-9PSL"
}
```
@@ -46,19 +49,27 @@ You get the following response:
|------------------|--------|--------------------------------------------------------------------|
| serialno | String | Serial Number of the monitor |
| wifi | Number | WiFi signal strength |
-| pm01, pm02, pm10 | Number | PM1, PM2.5 and PM10 in ug/m3 |
+| pm01 | Number | PM1 in ug/m3 |
+| pm02 | Number | PM2.5 in ug/m3 |
+| pm10 | Number | PM10 in ug/m3 |
+| pm02Compensated | Number | PM2.5 in ug/m3 with correction applied (from fw version 3.1.4 onwards) |
| rco2 | Number | CO2 in ppm |
| pm003Count | Number | Particle count per dL |
-| atmp | Number | Temperature in Degrees Celcius |
+| atmp | Number | Temperature in Degrees Celsius |
+| atmpCompensated | Number | Temperature in Degrees Celsius with correction applied |
| rhum | Number | Relative Humidity |
+| rhumCompensated | Number | Relative Humidity with correction applied |
| tvocIndex | Number | Senisiron VOC Index |
-| tvoc_raw | Number | VOC raw value |
+| tvocRaw | Number | VOC raw value |
| noxIndex | Number | Senisirion NOx Index |
-| nox_raw | Number | NOx raw value |
+| noxRaw | Number | NOx raw value |
| boot | Number | Counts every measurement cycle. Low boot counts indicate restarts. |
+| bootCount | Number | Same as boot property. Required for Home Assistant compatability. Will be depreciated. |
| ledMode | String | Current configuration of the LED mode |
-| firmwareVersion | String | Current firmware version |
-| fwMode | String | Current model name |
+| firmware | String | Current firmware version |
+| model | String | Current model name |
+
+Compensated values apply correction algorithms to make the sensor values more accurate. Temperature and relative humidity correction is only applied on the outdoor monitor Open Air but the properties _compensated will still be send also for the indoor monitor AirGradient ONE.
#### Get Configuration Parameters (GET)
With the path "/config" you can get the current configuration.
@@ -98,8 +109,11 @@ If the monitor is set up on the AirGradient dashboard, it will also receive conf
| Properties | Description | Type | Accepted Values | Example |
|-------------------------|:-------------------------------------------------------|---------|-----------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------|
| country | Country where the device is. | String | Country code as [ALPHA-2 notation](https://www.iban.com/country-codes) | {"country": "TH"} |
+| model | Hardware identifier (only GET). | String | I-9PSL-DE | {"model": "I-9PSL-DE"} |
| pmStandard | Particle matter standard used on the display. | String | `ugm3`: ug/m3
`us-aqi`: USAQI | {"pmStandard": "ugm3"} |
| ledBarMode | Mode in which the led bar can be set. | String | `co2`: LED bar displays CO2
`pm`: LED bar displays PM
`off`: Turn off LED bar | {"ledBarMode": "off"} |
+| displayBrightness | Brightness of the Display. | Number | 0-100 | {"displayBrightness": 50} |
+| ledBarBrightness | Brightness of the LEDBar. | Number | 0-100 | {"ledBarBrightness": 40} |
| abcDays | Number of days for CO2 automatic baseline calibration. | Number | Maximum 200 days. Default 8 days. | {"abcDays": 8} |
| mqttBrokerUrl | MQTT broker URL. | String | | {"mqttBrokerUrl": "mqtt://192.168.0.18:1883"} |
| temperatureUnit | Temperature unit shown on the display. | String | `c` or `C`: Degree Celsius °C
`f` or `F`: Degree Fahrenheit °F | {"temperatureUnit": "c"} |
@@ -107,3 +121,6 @@ If the monitor is set up on the AirGradient dashboard, it will also receive conf
| postDataToAirGradient | Send data to AirGradient cloud. | Boolean | `true`: Enabled
`false`: Disabled | {"postDataToAirGradient": true} |
| co2CalibrationRequested | Can be set to trigger a calibration. | Boolean | `true`: CO2 calibration (400ppm) will be triggered | {"co2CalibrationRequested": true} |
| ledBarTestRequested | Can be set to trigger a test. | Boolean | `true` : LEDs will run test sequence | {"ledBarTestRequested": true} |
+| noxLearningOffset | Set NOx learning gain offset. | Number | 0-720 (default 12) | {"noxLearningOffset": 12} |
+| tvocLearningOffset | Set VOC learning gain offset. | Number | 0-720 (default 12) | {"tvocLearningOffset": 12} |
+| offlineMode | Set monitor to run without WiFi. | Boolean | `false`: Disabled (default)
`true`: Enabled | {"offlineMode": true} |