Notifications
You must be signed in to change notification settings - Fork 127
2 Garage Doors (with multi channel device)
This simulation can be setup via the Homebridge/HOOBS UI, adding an entry in the 'Multi Channel Devices' section and setting the Device ID and the 'Show As' to '1 Garage Door'.
Or if you prefer to edit the configuration directly, set the deviceId
and choose the showAs
option to "garage"
. For example:
"multiDevices": [
{
"deviceId": "10009553c8",
"deviceModel": "dual_dualr2",
"showAs": "garage_two",
"operationTime": 100
}
]
- channel 0 connected to the 'up' motor and channel 1 connected to the 'down' motor for the first garage
- channel 2 connected to the 'up' motor and channel 3 connected to the 'down' motor for the second garage, and
- all channels 'inched' via the eWeLink app (I would recommend 0.5 seconds).
Your garage doors must be able to respond to this 'pulse' by starting to move up/down and then stopping with another 'pulse'. The plugin will send an initial request to turn the switch ON (and then be turned off by the eWeLink 'inching' setting) and the garage door will start moving. The plugin will then send another request to turn the switch ON (and then be turned off by the eWeLink 'inching' setting) after the operationTime
configuration setting to stop the garage door moving after the appropriate time.
The operationTime
is defined in deciseconds so time how long it takes to open/close the garage and multiply this by ten.
Since it is impossible for the switch to report the correct position of the garage doors to Homebridge, the plugin relies on a cached state which changes each time the garage doors are opened/closed. There may be times when this becomes out of sync. If this happens, please make sure all the garage doors are fully closed, then remove the accessory from the Homebridge cache. The accessory will be added again with a CLOSED status which will match the garage doors.