-
Notifications
You must be signed in to change notification settings - Fork 92
HydraFW 1 wire guide
Bus: 1-wire
Connections: One pin and ground
Output types: open drain/open collector
Pull-up resistors: required for open drain output mode (2K – 10K).
Pull-up/down resistors Integrated in MCU: Between 30 to 50K (Typical 40K).
Maximum voltage: 5.5volts (5volt safe)
This guide is updated towards firmware release HydraFW v0.9 Beta
-
show
Show 1-wire parameters orshow pins
Show pins used in this mode -
pull
with parameterup
ordown
orfloating
to choose internal MCU pull up/down or no pull/external -
msb-first
orlsb-first
to send/receive respectively MSB first or LSB first. -
scan
Discovers device on the 1-wire bus and displays their addresses. -
exit
to exit 1-wire mode
Note default value:
> 1-wire
Device: onewire1
GPIO resistor: floating
Bit order: LSB first
Hardware Informations:
onewire1> show pins
PIN: PB11
Configuration of onewire1 wit internal pullup :
> 1-wire
Device: onewire1
GPIO resistor: floating
Bit order: LSB first
onewire1> pull up
onewire1> show
Device: onewire1
GPIO resistor: pull-up
Bit order: LSB first
onewire1>
trigger
configures the trigger mode
r
or read
Read one byte. (r:1…255 for bulk reads)
hd
Read one byte. (hd:1…4294967295 for bulk reads). Displays a hexdump of the result (See Hexdump guide)
w
or write
Followed by values to write byte(s). (w:1…255 for bulk writes)
0
Write this Octal value. Format is prefixed by a 0 (values from 000 to 077)
0b
Write this binary value. Format is 0b00000000 for a byte, but partial bytes are also fine: 0b1001.
0x
Write this HEX value. Format is 0x01. Partial bytes are fine: 0xA. A-F can be lower-case or capital letters.
0-255
Write this decimal value. Any number not preceded by 0x or 0b is interpreted as a decimal value.
"
Write an ASCII-encoded string
Write support optional repeat :
(eg.: 10:1…255 for repeated write of same value 10 in this example)
space
Value delimiter.
Use a space to separate numbers/commands.
Any combination is fine, delimiter is required between each number/command, example: [ 0x1 0xff 0 10 0b11 077 ]
&
Delay 1uS. (&:1…1000000 for multiple delays)
%
Delay 1mS. (%:1…1000000 for multiple delays)
~
Write a random byte. (~:10 repeats the same random byte 10 times)
onewire1> scan
Discovered devices : 28 FF 10 2E A6 15 01 3B
onewire1> [ 0x33 hd:8
WRITE: 0x33
28 FF 10 2E A6 15 01 3B | (......;
For more information about the 1-wire protocol, see : https://www.maximintegrated.com/en/app-notes/index.mvp/id/1796
- CHANGELOG
- Console commands
- Binary mode guide
-
NFC/HydraNFC v1 guide
- Read UID of an ISO/IEC_14443 Tag
- Read UID and data of a MIFARE Ultralight Tag
- Read UID of an ISO/IEC 15693 Tag
- Emul ISO14443a Tag
- Emul MIFARE Ultralight Tag
- Emul Mifare Classic Tag
- Unique NFC sniffer design
- Launch NFC sniffer from console
- Sniffer ISO14443A wireshark pcap
- Autonomous/stand-alone sniffer mode
- Sniffer ISO14443A real-time infinite trace mode
- HydraFW-HydraNFC-v1.x-TRF7970A-Tutorial