Expand Up @@ -242,9 +242,17 @@ Set the thermocycler for the following program:
2. Inoculate 30 mL LB with bacteria (correct stringency, correct media depending on strain), grow to OD<sub>600</sub> of 0.6 (takes about 8 h). Bacteria can be stored in the fridge overnight.
3. Important: Work in sterile conditions when assembling the reactor to avoid contaminations. All components should be either autoclaved or sterile already.
4. Add antibiotics/inducers etc. to media bottle
5. Set up hardware: connect tubing and insert tubes into pump, connect waste and media bottles. Make sure the orientation of the tubing in the pumps is correct.
6. Prepare glass bottle for chemostat (transfer 30 mL of liquid culture grown the day before). Mark the liquid level with a pen on the bottle.
7. Insert the three needles in the lagoon
5. Set up hardware: connect tubing and insert tubes into pump, connect waste and media bottles (see figure). Make sure the orientation of the tubing in the pumps is correct.

<figure markdown>
![Figure_tubing](https://idec-teams.github.io/2024_Evolution_Suisse/img/PACE_related_schematics/PACE_protocol_1.png)
<figcaption> Set up of the PACE reactor.
</figcaption>
</figure>


7. Prepare glass bottle for chemostat (transfer 30 mL of liquid culture grown the day before). Mark the liquid level with a pen on the bottle.
8. Insert the three needles in the lagoon
* Waste: insert it at the edge. It should touch the liquid surface and put it against the glass wall
* Fresh media: should be inserted at the centre, higher than the waste needle
* Air: only insert it a bit (highest needle), connect a sterile filter on the outside.
Expand All @@ -254,6 +262,7 @@ Set the thermocycler for the following program:
<figcaption> Media and waste tubing in the lagoon of the PACE reactor.
</figcaption>
</figure>


8. Run Chemostat until the correct OD is reached. (e.g. overnight)
9. Set up lagoon:
Expand Down