Question about Figure 4 in the white paper #27

Closed
yunchang-z opened this issue Jan 7, 2025 · 1 comment
Closed

Question about Figure 4 in the white paper #27

yunchang-z opened this issue Jan 7, 2025 · 1 comment

Comments

@yunchang-z
Copy link

Hi! The legend of figure 4 says that the dead channels are labeled with blue dots. But panel A only shows two channels with red dots (I assume they are dead channels). Is this an issue to be fixed or am I misunderstanding something? Thank you!

Screenshot 2025-01-07 at 11 34 33 AM

@oliche
Copy link
Member

oliche commented Jan 20, 2025

Hi, yes the caption needs updating as the high transparency blue dots are invisible on the density displays.
Here panel a) shows 2 dead channels with red dots and b) shows 2 noisy channels with red dots an c) a few uppermost channels detected outside the brain.