@JohnPreston Some considerations:
Are you doing the calibration correctly? Remember that that:
Better yet, calculate the calibration values only once and in the next execution pass the values as follows: mpu.calibrate() # Calibrate all sensors
abias = mpu.abias # Get the master accelerometer biases
gbias = mpu.gbias # Get the master gyroscope biases
magScale = mpu.magScale # Get magnetometer soft iron distortion
mbias = mpu.mbias # Get magnetometer hard iron distortion Save the values of all these variables (print on the console) and set parameters for the following variables: mpu.abias = [0, 0, 0] # Set the master accelerometer biases
mpu.gbias = [0, 0, 0] # Set the master gyroscope biases
mpu.magScale = [0, 0, 0] # Set magnetometer soft iron distortion
mpu.mbias = [0, 0, 0] # Set magnetometer hard iron distortion Final code example: import time
import math
from mpu9250_jmdev.registers import *
from mpu9250_jmdev.mpu_9250 import MPU9250
##################################################
# Create
##################################################
mpu = MPU9250(
address_ak=AK8963_ADDRESS,
address_mpu_master=MPU9050_ADDRESS_69,
address_mpu_slave=None,
bus=1,
gfs=GFS_1000,
afs=AFS_8G,
mfs=AK8963_BIT_16,
mode=AK8963_MODE_C100HZ,
)
##################################################
# Configure
##################################################
mpu.configure() # Apply the settings to the registers.
##################################################
# Calibrate - Only the first time/execution
##################################################
# mpu.calibrate() # Calibrate sensors
# mpu.configure() # The calibration function resets the sensors, so you need to reconfigure them
##################################################
# Get Calibration - Only the first time/execution - Place the values printed in the block 'Set Calibration'
##################################################
# abias = mpu.abias # Get the master accelerometer biases
# gbias = mpu.gbias # Get the master gyroscope biases
# magScale = mpu.magScale # Get magnetometer soft iron distortion
# mbias = mpu.mbias # Get magnetometer hard iron distortion
# print("|.....MPU9250 in 0x69 Biases.....|")
# print("Accelerometer", abias)
# print("Gyroscope", gbias)
# print("Magnetometer SID", magScale)
# print("Magnetometer HID", mbias)
# print("\n")
##################################################
# Set Calibration - Use from the second time/execution
##################################################
mpu.abias = [-0.08004239710365854, 0.458740234375, 0.2116996951219512]
mpu.gbias = [0.8958025676448171, 0.45292551924542684, 0.866773651867378]
mpu.magScale = [1.0104166666666667, 0.9797979797979799, 1.0104166666666667]
mpu.mbias = [2.6989010989010986, 2.7832417582417586, 2.6989010989010986]
##################################################
# Show Values #
##################################################
while True:
print("|.....MPU9250 in 0x69 Address.....|")
print("Accelerometer", mpu.readAccelerometerMaster())
print("Gyroscope", mpu.readGyroscopeMaster())
print("Magnetometer", mpu.readMagnetometerMaster())
print("Temperature", mpu.readTemperatureMaster())
magnet = mpu.readMagnetometerMaster()
print(90 - math.atan2(magnet[0], magnet[1]) * 180 / math.pi)
time.sleep(1)
It is common for the values to vary very little in decimal places even when the sensor is 'stopped', don't worry about it. It is interesting that you enter a Full Scale Range (FSR) value for the accelerometer (AFS_2G, AFS_4G, AFS_8G or AFS_16G) and for the gyroscope (GFS_250, GFS_500, GFS_1000 or GFS_2000) according to what your application needs. Note that the higher the FSR value you set, the greater the representation error (since there are a limited number of bits to represent the values). Likewise, the lower the FSR you put in, there will be less representation errors, but the sensor range is limited to a lower range. Share later if you managed to run correctly, it may be important for other people who use lib :) |
Thanks for replying so early. I have updated the code with the following as per your indications. import time
import math
from mpu9250_jmdev.registers import *
from mpu9250_jmdev.mpu_9250 import MPU9250
mpu = MPU9250(
address_ak=AK8963_ADDRESS,
address_mpu_master=MPU9050_ADDRESS_69,
address_mpu_slave=None,
bus=1,
gfs=GFS_1000,
afs=AFS_8G,
mfs=AK8963_BIT_16,
mode=AK8963_MODE_C100HZ,
)
mpu.configure()
mpu.calibrate()
mpu.configure()
count = 0
while True:
print(f"T+{count}")
print("Accelerometer", mpu.readAccelerometerMaster())
print("Gyroscope", mpu.readGyroscopeMaster())
print("Magnetometer", mpu.readMagnetometerMaster())
print("Temperature", mpu.readTemperatureMaster())
magnet = mpu.readMagnetometerMaster()
print(90 - math.atan2(magnet[0], magnet[1]) * 180 / math.pi)
time.sleep(1) Which still results into very different outputs Calibrating 0x69 - AK8963stro-py $ python gyro.py
Calibrating 0x69 - MPU6500
T+0
Accelerometer [-0.20703125, -1.586669921875, -7.0]
Gyroscope [0.00705718994140625, -0.10395050048828125, 0.3746032714843749]
Magnetometer [0.3842335771422301, -0.26008066107742706, 0.48456832519332504]
Temperature 24.354599095456315
-34.093350546568814
T+1
Accelerometer [-0.196533203125, -1.5869140625, -7.0]
Gyroscope [-0.11501312255859375, 0.07915496826171875, 0.1609802246093749]
Magnetometer [-0.3842335771422301, 1.1270161980021862, -0.16152277506444168]
Temperature 24.546290472339532
135.2081701043849
T+2
Accelerometer [-0.1962890625, -1.58935546875, -7.0]
Gyroscope [0.00705718994140625, 0.10967254638671875, 0.2525329589843749]
Magnetometer [-0.7684671542844526, 0.7802419832322881, 0.16152277506444168]
Temperature 24.450444783897925
242.9150279871158
T+3
Accelerometer [-0.19384765625, -1.58740234375, -7.0]
Gyroscope [-0.05397796630859375, -0.25653839111328125, -0.05264282226562511]
Magnetometer [-1.729051097140028, 1.3004033053871422, 0.6460911002577667]
Temperature 24.546290472339532
143.0535135824202
T+4
Accelerometer [-0.199462890625, -1.59423828125, -7.0]
Gyroscope [0.19016265869140625, -0.28705596923828125, -0.2967834472656251]
Magnetometer [-0.3842335771422301, 1.1270161980021862, -0.8076138753222084]
Temperature 24.450444783897925
133.52317032931552
T+5
Accelerometer [-0.20166015625, -1.59228515625, -7.0]
Gyroscope [0.00705718994140625, -0.10395050048828125, 0.09994506835937489]
Magnetometer [0.3842335771422301, -0.26008066107742706, -0.16152277506444168]
Temperature 24.737981849222752
44.3545018316897
T+6
Accelerometer [-0.2060546875, -1.579345703125, -7.0]
Gyroscope [0.00705718994140625, -0.13446807861328125, 0.008392333984374889]
Magnetometer [-1.3448175199977976, -0.08669355369247106, -0.6460911002577667]
Temperature 24.59421331656034
183.68846407101896
The board is laying flat on the bread-board which itself is flat relative to the horizon, the MPU is facing up (to the sky). My aspiration is to be able to use the magnetometer to drive a platform to point to a specific azimuth (angle relative to magnetic north) so I do not need (I suppose) insane frequency of updates, as the rotation would be very slow anyway. The gyro would eventually give me elevation from the horizon. Of course for the purpose of this exercise I would probably set the bias once and only re-calibrate if I moved significantly (geographically) for better accuracy. That said, can one not just do mpu.configure()
mpu.calibrate()
mpu.configure() every time? Thank you very much. |
Hi I have same problem: My code:
Output(The board is laying flat on the bread-board which itself is flat relative to the horizon, the MPU is facing up to the sky):
|
Same here. I havent had time to pet the project using this since to try new things but problem remains. |
Describe the bug
The readings from the board are changing dramatically whilst the board is completely still.
Hello :)
I recently aquired the MPU9250 as an upgrade to get the magnetometer to be able to read the heading.
Whilst looking for a library, this one seemed to be by far the most solid in docs and examples.
So unless I am a complete dummy (which is possible) something seems wrong with the readings I am getting.
Because it is not moving, the accelerometer seems to be rather stable.
The gyro and the magnetometer though are behaving as if there was movement.
I do not have another MPU9250 to compare this to.
Any good guess on what might be going on / what I am doing wrong ?
Many thanks,
To Reproduce
Expected behavior
Expecting the values to be constant when the module is not moving at all
Screenshots
If applicable, add screenshots to help explain your problem.
Desktop (please complete the following information):
The text was updated successfully, but these errors were encountered: