MODULE EGMCommunication
! Author: Felipe Fronchetti
! Email: [email protected]
! This file is not affiliated, sponsored
! or approved by ABB. Always refer to their application
! manual for more information.
! Identifier for EGM process
VAR egmident egm_id;
! Current state of EGM process on controller
VAR egmstate egm_state;
! Convergence criteria for translation and rotation (in degrees)
CONST egm_minmax egm_minmax_translation := [-1, 1];
CONST egm_minmax egm_minmax_rotation := [-1, 1];
! Correction frame for path correction
LOCAL CONST pose egm_correction_frame := [[0, 0, 0], [1, 0, 0, 0]];
LOCAL CONST pose egm_sensor_frame := [[0, 0, 0], [1, 0, 0, 0]];
! Main function
PROC main()
EGM_POSE_MOVEMENT;
ENDPROC
! EGM function used to move the robot to a specific position using a pose target.
! In this approach, the external device sends a message to the robot specifying angles and a position
! in the cartesian coordinate system where the robot should move to.
PROC EGM_POSE_MOVEMENT()
! Check if no EGM setup is active.
IF egm_state = EGM_STATE_DISCONNECTED THEN
TPWrite "EGM State: Preparing controller for EGM communication.";
ENDIF
WHILE TRUE DO
! Register a new EGM id.
EGMGetId egm_id;
! Get current state of egm_id.
egm_state := EGMGetState(egm_id);
! Setup the EGM communication.
! Make sure the external device name being used is the same specified in
! the controller communication tab. In this example, the UdpUc device name is PC,
! moving the robot mechanical unit ROB_1.
IF egm_state <= EGM_STATE_CONNECTED THEN
EGMSetupUC ROB_1, egm_id, "default", "PC", \Pose;
ENDIF
! De-serializes the message sent by the external device.
EGMActPose egm_id\Tool:=tool0,
egm_correction_frame,
EGM_FRAME_BASE,
egm_sensor_frame,
EGM_FRAME_BASE
\x:=egm_minmax_translation
\y:=egm_minmax_translation
\z:=egm_minmax_translation
\rx:=egm_minmax_rotation
\ry:=egm_minmax_rotation
\rz:=egm_minmax_rotation
\LpFilter:= 16
\MaxSpeedDeviation:=100;
! Performs a movement based on the pose target sent by the external device.
EGMRunPose egm_id, EGM_STOP_HOLD \x \y \z \rx \ry \rz \CondTime:=1\RampInTime:=0;
! (Debugging) Checks if robot is listening for external commands.
IF egm_state = EGM_STATE_CONNECTED THEN
TPWrite "EGM State: Waiting for movement request.";
ENDIF
! (Debugging) Checks if the robot received an external command and is moving.
IF egm_state = EGM_STATE_RUNNING THEN
TPWrite "EGM State: Movement request received. Robot is moving.";
ENDIF
! Reset EGM communication.
IF egm_state <= EGM_STATE_CONNECTED THEN
EGMReset egm_id;
ENDIF
ENDWHILE
! (Debugging) Checks if external devices are available.
ERROR
IF ERRNO = ERR_UDPUC_COMM THEN
TPWrite "EGM Warning: Robot is not detecting any external devices.";
TRYNEXT;
ENDIF
ENDPROC
ENDMODULE