diff --git a/Events.txt b/Events.txt new file mode 100644 index 0000000..38dee7b --- /dev/null +++ b/Events.txt @@ -0,0 +1,289 @@ +Description of MG/SP Events +Table 12: List of events for MG/SP control panels +Event Group Event Group Description Sub-group Sub-group Description +00 Zone OK 01 to 32 Zone number +01 Zone open 99 Any zone number +02 Partition status 00 to 01 - + 02 Silent alarm + 03 Buzzer alarm + 04 Steady alarm + 05 Pulsed alarm + 06 Strobe + 07 Alarm stopped + 08 Squawk ON (partition 1only) + 09 Squawk OFF (partition 1 only) + 10 Ground start (partition 1 only) + 11 Disarm partition + 12 Arm partition + 13 Entry delay started + 14 Exit delay started + 15 Pre-alarm delay + 16 Report confirmation + 99 Any partition status event +03 Bell status (partition 1 only) 00 Bell OFF + 01 Bell ON + 02 Bell squawk arm + 03 Bell squawk disarm + 99 Any bell status event +06 Non-reportable event 00 Telephone line trouble + 01 CLEAR + ENTER, or was pressed for 3 secs. (partition 1 only) + 02 - + 03 Arm in Stay mode + 04 Arm in Sleep mode + 05 Arm in Force mode + 06 Full arm when armed in Stay mode + 07 PC fail to communicate (partition 1 only) + 08 Utility key 1 pressed (keys 1 and 2; partition 1 only) + 09 Utility key 2 pressed (keys 4 and 5; partition 1 only) + 10 Utility key 3 pressed (keys 7 and 8; partition 1 only) + 11 Utility key 4 pressed (keys 2 and 3; partition 1 only) + 12 Utility key 5 pressed (keys 5 and 6; partition 1 only) + 13 Utility key 6 pressed (keys 8 and 9; partition 1 only) + 14 Tamper generated alarm + 15 Supervision loss generated alarm + 16 - + 17 - + 18 - + 19 - + 20 Full arm when armed in Sleep mode + 21 Firmware upgrade (partition 1 only; non-PGM event) + 22 - + 23 StayD mode activated + 24 StayD mode deactivated + +Event Group Event Group Description Sub-group Sub-group Description +06 +(Cont.) Non-reportable event (Cont.) 25 IP registration status change + 26 GPRS registration status change + 27 Armed with trouble(s) + 28 Supervision alert + 29 Supervision alert restore + 30 Armed with remote with low battery + 99 Any non-reportable event +08 Button pressed on remote (see Default Data B, in worksheet 26 on page 35) 01 to 32 Remote control number + 99 Any remote control number +09 Button pressed on remote (see Default Data C, in worksheet 26 on page 35) 01 to 32 Remote control number + 99 Any remote control number +10 Button pressed on remote (see Default Data D, in worksheet 26 on page 35) 01 to 32 Remote control number + 99 Any remote control number +11 Button pressed on remote (see Default Data E, in worksheet 26 on page 35) 01 to 32 Remote control number + 99 Any remote control number +12 Cold start wireless zone 01 to 32 Zone number + 99 Any zone number +13 Cold start wireless module (partition 1 only) 01 to 16 Output number + 17 to 18 Wireless repeater + 19 to 26 Wireless keypad + 27 to 30 Wireless siren + 99 Any output number +14 Bypass programming 01 to 32 User number + 99 Any user number +15 User code activated output (partition 1 only) 01 to 32 User number + 99 Any user number +16 Wireless smoke maintenance signal 01 to 32 Zone number + 99 Any zone number +17 Delay zone alarm transmission 01 to 32 Zone number + 99 Any zone number +18 Zone signal strength weak 1 (partition 1 only) 01 to 32 Zone number + 99 Any zone number +19 Zone signal strength weak 2 (partition 1 only) 01 to 32 Zone number + 99 Any zone number +20 Zone signal strength weak 3 (partition 1 only) 01 to 32 Zone number + 99 Any zone number +21 Zone signal strength weak 4 (partition 1 only) 01 to 32 Zone number + 99 Any zone number +22 Button pressed on remote (see option 5, in table 22 on page 34) 01 to 32 Remote control number + 99 Any remote control number +23 Button pressed on remote (see option 6, in table 22 on page 34) 01 to 32 Remote control number + 99 Any remote control number +24 Fire delay started 01 to 32 Zone number + 99 Any zone number + +Event Group Event Group Description Sub-group Sub-group Description +25 - - - +26 Software access (VDMP3, IP100, WinLoad, BabyWare) 00 Non-valid source ID + 01 WinLoad/BabyWare direct + 02 WinLoad/BabyWare through IP module + 03 WinLoad/BabyWare through GSM module + 04 WinLoad/BabyWare through modem + 09 IP100 direct + 10 VDMP3 direct + 11 Voice through GSM module + 12 Remote access + 13 SMS through GSM module + 99 Any software access +27 Bus module event 00 A bus module was added + 01 A bus module was removed + 02 2-way RF module communication failure + 03 2-way RF module communication restored + 99 Any bus module event +28 StayD pass acknowledged 01 to 32 Zone number + 99 Any zone number +29 Arming with user 01 to 32 User number + 99 Any user number +30 Special arming 00 Auto-arming (on-time/no movement) + 01 Late to close + 02 No movement arming + 03 Partial arming + 04 Quick arming + 05 Arming through WinLoad/BabyWare + 06 Arming with keyswitch + 99 Any special arming +31 Disarming with user 01 to 32 User number + 99 Any user number +32 Disarming after an alarm with user 01 to 32 User number + 99 Any user number +33 Alarm cancelled with user 01 to 32 User number + 99 Any user number +34 Special disarming 00 Auto-arm cancelled (on-time/no movement) + 01 Disarming through WinLoad/BabyWare + 02 Disarming through WinLoad/BabyWare after alarm + 03 Alarm cancelled through WinLoad/BabyWare + 04 Paramedical alarm cancelled + 05 Disarm with keyswitch + 06 Disarm with keyswitch after an alarm + 07 Alarm cancelled with keyswitch + 99 Any special disarming +35 Zone bypassed 01 to 32 Zone number + 99 Any zone number +36 Zone in alarm 01 to 32 Zone number + 99 Any zone number +37 Fire alarm 01 to 32 Zone number + 99 Any zone number + +Event Group Event Group Description Sub-group Sub-group Description +38 Zone alarm restore 01 to 32 Zone number + 99 Any zone number +39 Fire alarm restore 01 to 32 Zone number + 99 Any zone number +40 Special alarm 00 Panic non-medical emergency + 01 Panic medical (this panic alarm in not UL approved) + 02 Panic fire + 03 Recent closing + 04 Global shutdown + 05 Duress alarm + 06 Keypad lockout (partition 1 only) + 99 Any special alarm event +41 Zone shutdown 01 to 32 Zone number + 99 Any zone number +42 Zone tampered 01 to 32 Zone number + 99 Any zone number +43 Zone tamper restore 01 to 32 Zone number + 99 Any zone number +  + +Event Group Event Group Description Sub-group Sub-group Description +44 New trouble (partition 1 only, except sub-group 07, which is for both partitions) 00 - + 01 AC failure + 02 Battery failure + 03 Auxiliary current overload + 04 Bell current overload + 05 Bell disconnected + 06 Clock loss + 07 Fire loop trouble + 08 Fail to communicate with monitoring station telephone # 1 + 09 Fail to communicate with monitoring station telephone # 2 + 11 Fail to communicate with voice report + 12 RF jamming + 13 GSM RF jamming + 14 GSM no service + 15 GSM supervision lost + 16 Fail to communicate IP receiver 1 (GPRS) + 17 Fail to communicate IP receiver 2 (GPRS) + 18 IP module no service + 19 IP module supervision loss + 20 Fail to communicate IP receiver 1 (IP) + 21 Fail to communicate IP receiver 2 (IP) + 22 GSM/GPRS module tamper trouble + 99 Any new trouble event +45 Trouble restored 00 Telephone line restored + 01 AC failure restore + 02 Battery failure restore + 03 Auxiliary current overload + 04 Bell current overload restore + 05 Bell disconnected restore + 06 Clock loss restore + 07 Fire loop trouble restore + 08 Fail to communicate with monitoring station tel. # 1 restore + 09 Fail to communicate with monitoring station tel. # 2 restore + 11 Fail to communicate with voice report restore + 12 RF jamming restore + 13 GMS RF jamming restore + 14 GSM no service restore + 15 GSM supervision lost restore + 16 Fail to communicate restore IP receiver 1 (GPRS) + 17 Fail to communicate restore IP receiver 2 (GPRS) + 18 IP module no service restore + 19 IP module supervision loss restore + 20 Fail to communicate restore IP receiver 1 (IP) + 21 Fail to communicate restore IP receiver 2 (IP) + 22 GSM/GPRS module tamper trouble restore + 99 Any new trouble restored event + +Event Group Event Group Description Sub-group Sub-group Description +46 Bus/EBus/wireless module new trouble (partition 1 only) 00 Bus/EBus/wireless module communication fault + 01 Tamper trouble + 02 Power fail + 03 Battery failure + 99 Any bus module new trouble event +47 Bus/EBus/wireless module trouble restored (partition 1 only) 00 Bus/EBus/wireless module communication fault restore + 01 Tamper trouble restore + 02 Power fail restore + 03 Battery failure restore + 99 Any bus module new trouble restored event +48 Special (partition1 only) 00 System power up + 01 Reporting test + 02 Software log on + 03 Software log off + 04 Installer in programming mode + 05 Installer exited programming mode + 06 Maintenance in programming mode + 07 Maintenance exited programming mode + 08 Closing delinquency delay elapsed + 13 Failed to arm + 99 Any special event +49 Low battery on zone 01 to 32 Zone number + 99 Any zone number +50 Low battery on zone restore 01 to 32 Zone number + 99 Any zone number +51 Zone supervision trouble 01 to 32 Zone number + 99 Any zone number +52 Zone supervision restore 01 to 32 Zone number + 99 Any zone number +53 Wireless module supervision trouble (partition 1 only) 01 to 16 Output + 17 to 18 Wireless repeater + 19 to 22 Wireless keypad + 27 to 30 Wireless siren + 99 Any output number +54 Wireless module supervision restore (partition 1 only) 01 to 16 Output + 17 to 18 Wireless repeater + 19 to 22 Wireless keypad + 27 to 30 Wireless siren + 99 Any output number +55 Wireless module tamper trouble (partition 1 only) 01 to 16 Output + 17 to 18 Wireless repeater + 19 to 22 Wireless keypad + 27 to 30 Wireless siren + 99 Any output number +56 Wireless module tamper restore (partition 1 only) 01 to 16 Output + 17 to 18 Wireless repeater + 19 to 22 Wireless keypad + 27 to 30 Wireless siren + 99 Any output number +Event Group Event Group Description Sub-group Sub-group Description +57 Non-medical alarm (paramedic) 01 to 32 User number + 99 Any user number +58 Zone forced 01 to 32 Zone number + 99 Any zone number +59 Zone included 01 to 32 Zone number + Zone included (Cont.) 99 Any zone number +60 Remote low battery 01 to 32 User number + 99 Any user number +61 Remote low battery restore 01 to 32 User number + 99 Any user number +64 System status (on-board PGMs only) 00 Follow ARM LED status*: +PGM pulse fast in alarm +PGM pulse fast in exit delay, below 10 sec. +PGM pulse slow in exit delay, over 10 sec. +PGM steady ON, if armed +PGM OFF, if disarmed +* This event can be assigned to partition 1 or 2. If assigned to both partitions, the PGM event will follow the list order above, with number 1 being the highest priority.