Skip to content

Send Solarman Smart PV platform metrics (W/kWh) to MQTT

Notifications You must be signed in to change notification settings

megig/solarman-mqtt-by-lechk82

 
 

Repository files navigation

solarman-mqtt

Script to retrieve current Solar PV data from the Solarman API, and send Power (W) and Energy (kWh) metrics to a MQTT broker, for further use in home automation. Several PV vendors use the Solarman Smart platform for statistics. One example is the Trannergy PV converter.

usage: run.py [-h] [-d] [-s] [-i INTERVAL] [-f FILE] [-v]

Collect data from Trannergy / Solarman API

optional arguments:
-h, --help                       show this help message and exit
-d, --daemon                     run as a service (default)
-s, --single                     single run and exit
-i INTERVAL, --interval INTERVAL run interval in seconds (default 300 sec.)
-f FILE, --file FILE             config file (default ./config.json)
-v, --version                    show program's version number and exit

Usage

You can run this script as a Docker container or in Python 3. Either way a configuration file is required. See the sample config.sample.json file in this repository for reference. Also, a Solarman API appid+secret is required, which can be requested via mailto:[email protected].

MQTT topics

Station (Plant)

solarmanpv/station/batteryPower
solarmanpv/station/batterySoc
solarmanpv/station/chargePower
solarmanpv/station/dischargePower
solarmanpv/station/generationPower
solarmanpv/station/gridPower
solarmanpv/station/irradiateIntensity
solarmanpv/station/lastUpdateTime
solarmanpv/station/purchasePower
solarmanpv/station/usePower
solarmanpv/station/wirePower

Inverter

solarmanpv/inverter/deviceId
solarmanpv/inverter/deviceSn
solarmanpv/inverter/deviceState
solarmanpv/inverter/deviceType

solarmanpv/inverter/attributes # contains all inverter datalist entries.

Attributes:

SN: XXXXXXXXXX
Device_Type: 4
Production_Compliance_Type: 0
Rated_Power: 300.00
Year: 48
Month: 0
Day: 0
Hour: 0
Minute: 0
Seconds: 0
Communication_Protocol_Version: V0.2.0.1
Control_Board_Firmware_Version: V0.1.1.2
Communication_Board_Firmware_Version: V0.2.0.7
DC_Voltage_PV1: 0.00
DC_Voltage_PV2: 0.00
DC_Voltage_PV3: 0.00
DC_Voltage_PV4: 0.00
DC_Current_PV1: 0.00
DC_Current_PV2: 0.00
DC_Current_PV3: 0.00
DC_Current_PV4: 0.00
DC_Power_PV1: 0.00
DC_Power_PV2: 0.00
DC_Power_PV3: 0.00
DC_Power_PV4: 0.00
AC_Voltage_1: 0.00
AC_Current_1: 0.00
Total_AC_Output_Power(Active): 0
AC_Output_Frequency_1: 0.00
Total_Production(Active): 2.50
Total_Production_1: 2.50
Total_Production_2: 0.00
Total_Production_3: 0.00
Total_Production_4: 0.00
Daily_Production(Active): 0.70
Daily_Production_1: 0.70
Daily_Production_2: 0.00
Daily_Production_3: 0.00
Daily_Production_4: 0.00
AC_Radiator_Temp: -10.00
Micro_Inverter_Port_1: XXXXXXXXXX-1
Micro_Inverter_Port_2: XXXXXXXXXX-2
Micro_Inverter_Port_3: XXXXXXXXXX-3
Micro_Inverter_Port_4: XXXXXXXXXX-4
Number_Of_MPPT_Paths: 1
Number_Of_Phases: 1
Running_Status: 4
Overfrequency_And_Load_Reduction_Starting_Point: 50.20
Islanding Protection Enabled: Enable
Overfrequency_And_Load_Reduction_Percentage: 44
GFDI Enabled: Disable
Grid-connected Standard: 0
Grid Voltage_Upper_Limit: 275.00
Grid Voltage_Lower_Limit: 180.00
Grid Frequency_Upper_Limit: 52.00
Grid Frequency_Lower_Limit: 47.50
Start-up Self-checking Time: 60

Logger (Collector)

solarmanpv/logger/deviceId
solarmanpv/logger/deviceSn
solarmanpv/logger/deviceState
solarmanpv/logger/deviceType

solarmanpv/logger/attributes # contains all logger datalist entries

Attributes

Embedded_Device_SN: XXXXXXXXXX
Module_Version_No: MW3_15_5406_1.35
Extended_System_Version: V1.1.00.07
Total_running_time: 1
Offset_time: 1634486607
Data_Uploading_Period: 5
Data_Acquisition_Period: 60
Max._No._of_Connected_Devices: 1
Signal_Strength: 100
Heart_Rate: 120
IV_Curve_Supported: 1
Batch_Command_Supported: 1
Support_Reporting_Upgrading_Progress: 0
AT+UPGRADE_Command_Supported: 255
Method_Of_Protocol_Upgrade: 255

Home Assistant

sensor:
  - platform: mqtt
    name: "solarmanpv_station_generationPower"
    state_topic: "solarmanpv/station/generationPower"
    unit_of_measurement: "W"
    state_class: measurement

Repeat for every station topic needed.

sensor:
  - platform: mqtt
    name: "solarmanpv_inverter"
    state_topic: "solarmanpv/inverter/deviceState"
    json_attributes_topic: "solarmanpv/inverter/attributes"
    
  - platform: mqtt
    name: "solarmanpv_logger"
    state_topic: "solarmanpv/logger/deviceState"
    json_attributes_topic: "solarmanpv/logger/attributes"

  - platform: template
    sensors:
      solarmanpv_inverter_device_state:
        entity_id: sensor.solarmanpv_inverter
        value_template: >-
          {% set mapper =  {
              '1' : 'Online',
              '2' : 'Failure',
              '3' : 'Offline'} %}
          {% set state =  states.sensor.solarmanpv_inverter.state %}
          {{ mapper[state] if state in mapper else 'Unknown' }}
         
  - platform: template
    sensors:
      solarmanpv_logger_device_state:
        entity_id: sensor.solarmanpv_logger
        value_template: >-
          {% set mapper =  {
              '1' : 'Online',
              '2' : 'Failure',
              '3' : 'Offline'} %}
          {% set state =  states.sensor.solarmanpv_logger.state %}
          {{ mapper[state] if state in mapper else 'Unknown' }}

Templates

template:
  - sensor:
    - name: solarmanpv_inverter_dc_voltage_pv1
      unit_of_measurement: 'V'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Voltage_PV1') }}"
      state_class: measurement
  - sensor:
    - name: solarmanpv_inverter_dc_current_pv1
      unit_of_measurement: 'A'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Current_PV1') }}"
      state_class: measurement
      
  - sensor:
    - name: solarmanpv_inverter_dc_power_pv1
      unit_of_measurement: 'W'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Power_PV1') }}"
      state_class: measurement
      
  - sensor:
    - name: solarmanpv_inverter_dc_power_pv1
      unit_of_measurement: 'W'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Power_PV1') }}"
      state_class: measurement
      
  - sensor:
    - name: solarmanpv_inverter_total_production_1
      unit_of_measurement: 'kWh'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'Total_Production_1') }}"
      state_class: total_increasing
      
  - sensor:
    - name: solarmanpv_inverter_daily_production_1
      unit_of_measurement: 'kWh'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'Daily_Production_1') }}"
      state_class: total_increasing

  - sensor:
    - name: solarmanpv_inverter_ac_radiator_temp
      unit_of_measurement: '°C'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Radiator_Temp') }}"
      state_class: measurement
      
  - sensor:
    - name: solarmanpv_inverter_ac_voltage_1
      unit_of_measurement: 'V'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Voltage_1') }}"
      state_class: measurement
      
  - sensor:
    - name: solarmanpv_inverter_ac_current_1
      unit_of_measurement: 'A'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Current_1') }}"
      state_class: measurement

  - sensor:
    - name: solarmanpv_inverter_ac_output_frequency_1
      unit_of_measurement: 'Hz'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Output_Frequency_1') }}"
      state_class: measurement

Screenshot

Screenshot Screenshot

Using Docker

Supported platforms:

  • linux/amd64
  • linux/386
  • linux/arm/v7
  • linux/arm/v6
  • linux/arm64

Docker example to run this script every 5 minutes and providing a config file:

cd /opt
git clone https://github.com/lechk82/solarman-mqtt
cd solarman-mqtt
mv config.sample.json config.json # setup your config
sudo docker run --name solarman-mqtt -d --restart unless-stopped -v /opt/solarman-mqtt:/opt/app-root/src ghcr.io/lechk82/solarman-mqtt:latest

Using docker-compose

This docker-compose.yml example can be used with docker-compose or podman-compose

version: '3'

services:
  solarman-mqtt:
    image: ghcr.io/lechk82/solarman-mqtt:latest
    container_name: "solarman-mqtt"
    environment:
    - TZ=Europe/Berlin
    volumes:
      - /opt/solarman-mqtt:/opt/app-root/src
    restart: unless-stopped

Using Python

Run pip install -r requirements.txt and start python3 run.py.

About

Send Solarman Smart PV platform metrics (W/kWh) to MQTT

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages

  • Python 64.5%
  • Dockerfile 35.5%