You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
After activating of the debugging I receive the following message Did not receive an SML message within 30 seconds, starting over.
State of sensor 1 is 'WAIT_FOR_START_SEQUENCE'._
Maybe something is wrong with the positioning of the sensor or the circuit. Polarity, pullup, wiring....
My approach would be
check if the meter is actually transmitting (use a phone camera, it should display purple flashes every second. Verify that the phone's camera can pick up infared with the remote control of your TV. Some cameras have an IR filter.
check polarity, pullup value and wiring
check the sensor's signal with an oszilloscope. Maybe something can be seen with a multimeter.
enviroment:
Nodemcu ESP8266
Smart Meter ISKRA MT691 INFO mode enabled
I could uploaf the FW succesfully. the IR transistor is conected to GPIO 4 i2C_SDA.
The SMLReader connects to the MQTT Broker ( in this case IOBroker ), the Value LWT and info appears but no SMART Meter Voltage/Current information.
Could you assist me
The text was updated successfully, but these errors were encountered: