diff --git a/EXTRAS/reports/radwin_oids b/EXTRAS/reports/radwin_oids new file mode 100644 index 00000000..3f7c8782 --- /dev/null +++ b/EXTRAS/reports/radwin_oids @@ -0,0 +1,1823 @@ +.1.3,RFC1155-SMI::org,,,,,, +.1.3.6,RFC1155-SMI::dod,,,,,, +.1.3.6.1,RFC1155-SMI::internet,,,,,, +.1.3.6.1.1,RFC1155-SMI::directory,,,,,, +.1.3.6.1.2,RFC1155-SMI::mgmt,,,,,, +.1.3.6.1.2.1,SNMPv2-SMI::mib-2,,,,,, +.1.3.6.1.2.1.1,RFC1213-MIB::system,,,,,, +.1.3.6.1.2.1.1.1,RFC1213-MIB::sysDescr,OCTET,read-only,,mandatory,,A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. It is mandatory that this only contain printable ASCII characters. +.1.3.6.1.2.1.1.2,RFC1213-MIB::sysObjectID,OBJECT,read-only,,mandatory,,The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining `what kind of box' is being managed. For example, if vendor `Flintstones, Inc.' was assigned the subtree 1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'. +.1.3.6.1.2.1.1.3,RFC1213-MIB::sysUpTime,TimeTicks,read-only,,mandatory,,The time (in hundredths of a second) since the network management portion of the system was last re-initialized. +.1.3.6.1.2.1.1.4,RFC1213-MIB::sysContact,OCTET,read-write,,mandatory,,The textual identification of the contact person for this managed node, together with information on how to contact this person. +.1.3.6.1.2.1.1.5,RFC1213-MIB::sysName,OCTET,read-write,,mandatory,,An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. +.1.3.6.1.2.1.1.6,RFC1213-MIB::sysLocation,OCTET,read-write,,mandatory,,The physical location of this node (e.g., `telephone closet, 3rd floor'). +.1.3.6.1.2.1.1.7,RFC1213-MIB::sysServices,INTEGER,read-only,,mandatory,,A value which indicates the set of services that this entity primarily offers. The value is a sum. This sum initially takes the value zero, Then, for each layer, L, in the range 1 through 7, that this node performs transactions for, 2 raised to (L - 1) is added to the sum. For example, a node which performs primarily routing functions would have a value of 4 (2^(3-1)). In contrast, a node which is a host offering application services would have a value of 72 (2^(4-1) + 2^(7-1)). Note that in the context of the Internet suite of protocols, values should be calculated accordingly: layer functionality 1 physical (e.g., repeaters) 2 datalink/subnetwork (e.g., bridges) 3 internet (e.g., IP gateways) 4 end-to-end (e.g., IP hosts) 7 applications (e.g., mail relays) For systems including OSI protocols, layers 5 and 6 may also be counted. +.1.3.6.1.2.1.2,RFC1213-MIB::interfaces,,,,,, +.1.3.6.1.2.1.2.1,RFC1213-MIB::ifNumber,INTEGER,read-only,,mandatory,,The number of network interfaces (regardless of their current state) present on this system. +.1.3.6.1.2.1.2.2,RFC1213-MIB::ifTable,,not-accessible,,mandatory,,A list of interface entries. The number of entries is given by the value of ifNumber. +.1.3.6.1.2.1.2.2.1,RFC1213-MIB::ifEntry,,not-accessible,ifIndex,mandatory,,An interface entry containing objects at the subnetwork layer and below for a particular interface. +.1.3.6.1.2.1.2.2.1.1,RFC1213-MIB::ifIndex,INTEGER,read-only,,mandatory,,A unique value for each interface. Its value ranges between 1 and the value of ifNumber. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization. +.1.3.6.1.2.1.2.2.1.2,RFC1213-MIB::ifDescr,OCTET,read-only,,mandatory,,A textual string containing information about the interface. This string should include the name of the manufacturer, the product name and the version of the hardware interface. +.1.3.6.1.2.1.2.2.1.3,RFC1213-MIB::ifType,INTEGER,read-only,,mandatory,other(1):regular1822(2):hdh1822(3):ddnX25(4):rfc877x25(5):ethernetCsmacd(6):iso88023Csmacd(7):iso88024TokenBus(8):iso88025TokenRing(9):iso88026Man(10):starLan(11):proteon10Mbit(12):proteon80Mbit(13):hyperchannel(14):fddi(15):lapb(16):sdlc(17):ds1(18):e1(19):basicISDN(20):primaryISDN(21):propPointToPointSerial(22):ppp(23):softwareLoopback(24):eon(25):ethernet3Mbit(26):nsip(27):slip(28):ultra(29):ds3(30):sip(31):frameRelay(32):rs232(33):para(34):arcnet(35):arcnetPlus(36):atm(37):miox25(38):sonet(39):x25ple(40):iso88022llc(41):localTalk(42):smdsDxi(43):frameRelayService(44):v35(45):hssi(46):hippi(47):modem(48):aal5(49):sonetPath(50):sonetVT(51):smdsIcip(52):propVirtual(53):propMultiplexor(54):ieee80212(55):fibreChannel(56):hippiInterface(57):frameRelayInterconnect(58):aflane8023(59):aflane8025(60):cctEmul(61):fastEther(62):isdn(63):v11(64):v36(65):g703at64k(66):g703at2mb(67):qllc(68):fastEtherFX(69):channel(70):ieee80211(71):ibm370parChan(72):escon(73):dlsw(74):isdns(75):isdnu(76):lapd(77):ipSwitch(78):rsrb(79):atmLogical(80):ds0(81):ds0Bundle(82):bsc(83):async(84):cnr(85):iso88025Dtr(86):eplrs(87):arap(88):propCnls(89):hostPad(90):termPad(91):frameRelayMPI(92):x213(93):adsl(94):radsl(95):sdsl(96):vdsl(97):iso88025CRFPInt(98):myrinet(99):voiceEM(100):voiceFXO(101):voiceFXS(102):voiceEncap(103):voiceOverIp(104):atmDxi(105):atmFuni(106):atmIma(107):pppMultilinkBundle(108):ipOverCdlc(109):ipOverClaw(110):stackToStack(111):virtualIpAddress(112):mpc(113):ipOverAtm(114):iso88025Fiber(115):tdlc(116):gigabitEthernet(117):hdlc(118):lapf(119):v37(120):x25mlp(121):x25huntGroup(122):transpHdlc(123):interleave(124):fast(125):ip(126):docsCableMaclayer(127):docsCableDownstream(128):docsCableUpstream(129):a12MppSwitch(130):tunnel(131):coffee(132):ces(133):atmSubInterface(134):l2vlan(135):l3ipvlan(136):l3ipxvlan(137):digitalPowerline(138):mediaMailOverIp(139):dtm(140):dcn(141):ipForward(142):msdsl(143):ieee1394(144):if-gsn(145):dvbRccMacLayer(146):dvbRccDownstream(147):dvbRccUpstream(148):atmVirtual(149):mplsTunnel(150):srp(151):voiceOverAtm(152):voiceOverFrameRelay(153):idsl(154):compositeLink(155):ss7SigLink(156):propWirelessP2P(157):frForward(158):rfc1483(159):usb(160):ieee8023adLag(161):bgppolicyaccounting(162):frf16MfrBundle(163):h323Gatekeeper(164):h323Proxy(165):mpls(166):mfSigLink(167):hdsl2(168):shdsl(169):ds1FDL(170):pos(171):dvbAsiIn(172):dvbAsiOut(173):plc(174):nfas(175):tr008(176):gr303RDT(177):gr303IDT(178):isup(179):propDocsWirelessMaclayer(180):propDocsWirelessDownstream(181):propDocsWirelessUpstream(182):hiperlan2(183):propBWAp2Mp(184):sonetOverheadChannel(185):digitalWrapperOverheadChannel(186):aal2(187):radioMAC(188):atmRadio(189):imt(190):mvl(191):reachDSL(192):frDlciEndPt(193):atmVciEndPt(194):opticalChannel(195):opticalTransport(196):propAtm(197):voiceOverCable(198):infiniband(199):teLink(200):q2931(201):virtualTg(202):sipTg(203):sipSig(204):docsCableUpstreamChannel(205):econet(206):pon155(207):pon622(208):bridge(209):linegroup(210):voiceEMFGD(211):voiceFGDEANA(212):voiceDID(213):mpegTransport(214):sixToFour(215):gtp(216):pdnEtherLoop1(217):pdnEtherLoop2(218):opticalChannelGroup(219):homepna(220):gfp(221):ciscoISLvlan(222):actelisMetaLOOP(223):fcipLink(224):rpr(225):qam(226):lmp(227):cblVectaStar(228):docsCableMCmtsDownstream(229):adsl2(230):macSecControlledIF(231):macSecUncontrolledIF(232):aviciOpticalEther(233):atmbond(234):voiceFGDOS(235):mocaVersion1(236):ieee80216WMAN(237):adsl2plus(238):dvbRcsMacLayer(239):dvbTdm(240):dvbRcsTdma(241):x86Laps(242):wwanPP(243):wwanPP2(244):voiceEBS(245):ifPwType(246):ilan(247):pip(248):aluELP(249):gpon(250):vdsl2(251):capwapDot11Profile(252):capwapDot11Bss(253):capwapWtpVirtualRadio(254):bits(255):docsCableUpstreamRfPort(256):cableDownstreamRfPort(257):vmwareVirtualNic(258):ieee802154(259):otnOdu(260):otnOtu(261):ifVfiType(262):g9981(263):g9982(264):g9983(265):aluEpon(266):aluEponOnu(267):aluEponPhysicalUni(268):aluEponLogicalLink(269):aluGponOnu(270):aluGponPhysicalUni(271):vmwareNicTeam(272):docsOfdmDownstream(277):docsOfdmaUpstream(278):gfast(279):sdci(280):xboxWireless(281):fastdsl(282):docsCableScte55d1FwdOob(283):docsCableScte55d1RetOob(284):docsCableScte55d2DsOob(285):docsCableScte55d2UsOob(286):docsCableNdf(287):docsCableNdr(288):ptm(289):ghn(290):otnOtsi(291):otnOtuc(292):otnOduc(293):otnOtsig(294):microwaveCarrierTermination(295):microwaveRadioLinkTerminal(296),The type of interface, distinguished according to the physical/link protocol(s) immediately `below' the network layer in the protocol stack. +.1.3.6.1.2.1.2.2.1.4,RFC1213-MIB::ifMtu,INTEGER,read-only,,mandatory,,The size of the largest datagram which can be sent/received on the interface, specified in octets. For interfaces that are used for transmitting network datagrams, this is the size of the largest network datagram that can be sent on the interface. +.1.3.6.1.2.1.2.2.1.5,RFC1213-MIB::ifSpeed,Gauge32,read-only,,mandatory,,An estimate of the interface's current bandwidth in bits per second. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth. +.1.3.6.1.2.1.2.2.1.6,RFC1213-MIB::ifPhysAddress,OCTET,read-only,,mandatory,,The interface's address at the protocol layer immediately `below' the network layer in the protocol stack. For interfaces which do not have such an address (e.g., a serial line), this object should contain an octet string of zero length. +.1.3.6.1.2.1.2.2.1.7,RFC1213-MIB::ifAdminStatus,INTEGER,read-write,,mandatory,up(1):down(2):testing(3),The desired state of the interface. The testing(3) state indicates that no operational packets can be passed. +.1.3.6.1.2.1.2.2.1.8,RFC1213-MIB::ifOperStatus,INTEGER,read-only,,mandatory,up(1):down(2):testing(3),The current operational state of the interface. The testing(3) state indicates that no operational packets can be passed. +.1.3.6.1.2.1.2.2.1.9,RFC1213-MIB::ifLastChange,TimeTicks,read-only,,mandatory,,The value of sysUpTime at the time the interface entered its current operational state. If the current state was entered prior to the last re- initialization of the local network management subsystem, then this object contains a zero value. +.1.3.6.1.2.1.2.2.1.10,RFC1213-MIB::ifInOctets,Counter32,read-only,,mandatory,,The total number of octets received on the interface, including framing characters. +.1.3.6.1.2.1.2.2.1.11,RFC1213-MIB::ifInUcastPkts,Counter32,read-only,,mandatory,,The number of subnetwork-unicast packets delivered to a higher-layer protocol. +.1.3.6.1.2.1.2.2.1.12,RFC1213-MIB::ifInNUcastPkts,Counter32,read-only,,mandatory,,The number of non-unicast (i.e., subnetwork- broadcast or subnetwork-multicast) packets delivered to a higher-layer protocol. +.1.3.6.1.2.1.2.2.1.13,RFC1213-MIB::ifInDiscards,Counter32,read-only,,mandatory,,The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. +.1.3.6.1.2.1.2.2.1.14,RFC1213-MIB::ifInErrors,Counter32,read-only,,mandatory,,The number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. +.1.3.6.1.2.1.2.2.1.15,RFC1213-MIB::ifInUnknownProtos,Counter32,read-only,,mandatory,,The number of packets received via the interface which were discarded because of an unknown or unsupported protocol. +.1.3.6.1.2.1.2.2.1.16,RFC1213-MIB::ifOutOctets,Counter32,read-only,,mandatory,,The total number of octets transmitted out of the interface, including framing characters. +.1.3.6.1.2.1.2.2.1.17,RFC1213-MIB::ifOutUcastPkts,Counter32,read-only,,mandatory,,The total number of packets that higher-level protocols requested be transmitted to a subnetwork-unicast address, including those that were discarded or not sent. +.1.3.6.1.2.1.2.2.1.18,RFC1213-MIB::ifOutNUcastPkts,Counter32,read-only,,mandatory,,The total number of packets that higher-level protocols requested be transmitted to a non- unicast (i.e., a subnetwork-broadcast or subnetwork-multicast) address, including those that were discarded or not sent. +.1.3.6.1.2.1.2.2.1.19,RFC1213-MIB::ifOutDiscards,Counter32,read-only,,mandatory,,The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being transmitted. One possible reason for discarding such a packet could be to free up buffer space. +.1.3.6.1.2.1.2.2.1.20,RFC1213-MIB::ifOutErrors,Counter32,read-only,,mandatory,,The number of outbound packets that could not be transmitted because of errors. +.1.3.6.1.2.1.2.2.1.21,RFC1213-MIB::ifOutQLen,Gauge32,read-only,,mandatory,,The length of the output packet queue (in packets). +.1.3.6.1.2.1.2.2.1.22,RFC1213-MIB::ifSpecific,OBJECT,read-only,,mandatory,,A reference to MIB definitions specific to the particular media being used to realize the interface. For example, if the interface is realized by an ethernet, then the value of this object refers to a document defining objects specific to ethernet. If this information is not present, its value should be set to the OBJECT IDENTIFIER { 0 0 }, which is a syntatically valid object identifier, and any conformant implementation of ASN.1 and BER must be able to generate and recognize this value. +.1.3.6.1.2.1.3,RFC1213-MIB::at,,,,,, +.1.3.6.1.2.1.3.1,RFC1213-MIB::atTable,,not-accessible,,deprecated,,The Address Translation tables contain the NetworkAddress to `physical' address equivalences. Some interfaces do not use translation tables for determining address equivalences (e.g., DDN-X.25 has an algorithmic method); if all interfaces are of this type, then the Address Translation table is empty, i.e., has zero entries. +.1.3.6.1.2.1.3.1.1,RFC1213-MIB::atEntry,,not-accessible,atIfIndex:atNetAddress,deprecated,,Each entry contains one NetworkAddress to `physical' address equivalence. +.1.3.6.1.2.1.3.1.1.1,RFC1213-MIB::atIfIndex,INTEGER,read-write,,deprecated,,The interface on which this entry's equivalence is effective. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex. +.1.3.6.1.2.1.3.1.1.2,RFC1213-MIB::atPhysAddress,OCTET,read-write,,deprecated,,The media-dependent `physical' address. Setting this object to a null string (one of zero length) has the effect of invaliding the corresponding entry in the atTable object. That is, it effectively dissasociates the interface identified with said entry from the mapping identified with said entry. It is an implementation-specific matter as to whether the agent removes an invalidated entry from the table. Accordingly, management stations must be prepared to receive tabular information from agents that corresponds to entries not currently in use. Proper interpretation of such entries requires examination of the relevant atPhysAddress object. +.1.3.6.1.2.1.3.1.1.3,RFC1213-MIB::atNetAddress,NetworkAddress,read-write,,deprecated,,The NetworkAddress (e.g., the IP address) corresponding to the media-dependent `physical' address. +.1.3.6.1.2.1.4,RFC1213-MIB::ip,,,,,, +.1.3.6.1.2.1.4.1,RFC1213-MIB::ipForwarding,INTEGER,read-write,,mandatory,forwarding(1):not-forwarding(2),The indication of whether this entity is acting as an IP gateway in respect to the forwarding of datagrams received by, but not addressed to, this entity. IP gateways forward datagrams. IP hosts do not (except those source-routed via the host). Note that for some managed nodes, this object may take on only a subset of the values possible. Accordingly, it is appropriate for an agent to return a `badValue' response if a management station attempts to change this object to an inappropriate value. +.1.3.6.1.2.1.4.2,RFC1213-MIB::ipDefaultTTL,INTEGER,read-write,,mandatory,,The default value inserted into the Time-To-Live field of the IP header of datagrams originated at this entity, whenever a TTL value is not supplied by the transport layer protocol. +.1.3.6.1.2.1.4.3,RFC1213-MIB::ipInReceives,Counter32,read-only,,mandatory,,The total number of input datagrams received from interfaces, including those received in error. +.1.3.6.1.2.1.4.4,RFC1213-MIB::ipInHdrErrors,Counter32,read-only,,mandatory,,The number of input datagrams discarded due to errors in their IP headers, including bad checksums, version number mismatch, other format errors, time-to-live exceeded, errors discovered in processing their IP options, etc. +.1.3.6.1.2.1.4.5,RFC1213-MIB::ipInAddrErrors,Counter32,read-only,,mandatory,,The number of input datagrams discarded because the IP address in their IP header's destination field was not a valid address to be received at this entity. This count includes invalid addresses (e.g., 0.0.0.0) and addresses of unsupported Classes (e.g., Class E). For entities which are not IP Gateways and therefore do not forward datagrams, this counter includes datagrams discarded because the destination address was not a local address. +.1.3.6.1.2.1.4.6,RFC1213-MIB::ipForwDatagrams,Counter32,read-only,,mandatory,,The number of input datagrams for which this entity was not their final IP destination, as a result of which an attempt was made to find a route to forward them to that final destination. In entities which do not act as IP Gateways, this counter will include only those packets which were Source-Routed via this entity, and the Source- Route option processing was successful. +.1.3.6.1.2.1.4.7,RFC1213-MIB::ipInUnknownProtos,Counter32,read-only,,mandatory,,The number of locally-addressed datagrams received successfully but discarded because of an unknown or unsupported protocol. +.1.3.6.1.2.1.4.8,RFC1213-MIB::ipInDiscards,Counter32,read-only,,mandatory,,The number of input IP datagrams for which no problems were encountered to prevent their continued processing, but which were discarded (e.g., for lack of buffer space). Note that this counter does not include any datagrams discarded while awaiting re-assembly. +.1.3.6.1.2.1.4.9,RFC1213-MIB::ipInDelivers,Counter32,read-only,,mandatory,,The total number of input datagrams successfully delivered to IP user-protocols (including ICMP). +.1.3.6.1.2.1.4.10,RFC1213-MIB::ipOutRequests,Counter32,read-only,,mandatory,,The total number of IP datagrams which local IP user-protocols (including ICMP) supplied to IP in requests for transmission. Note that this counter does not include any datagrams counted in ipForwDatagrams. +.1.3.6.1.2.1.4.11,RFC1213-MIB::ipOutDiscards,Counter32,read-only,,mandatory,,The number of output IP datagrams for which no problem was encountered to prevent their transmission to their destination, but which were discarded (e.g., for lack of buffer space). Note that this counter would include datagrams counted in ipForwDatagrams if any such packets met this (discretionary) discard criterion. +.1.3.6.1.2.1.4.12,RFC1213-MIB::ipOutNoRoutes,Counter32,read-only,,mandatory,,The number of IP datagrams discarded because no route could be found to transmit them to their destination. Note that this counter includes any packets counted in ipForwDatagrams which meet this `no-route' criterion. Note that this includes any datagarms which a host cannot route because all of its default gateways are down. +.1.3.6.1.2.1.4.13,RFC1213-MIB::ipReasmTimeout,INTEGER,read-only,,mandatory,,The maximum number of seconds which received fragments are held while they are awaiting reassembly at this entity. +.1.3.6.1.2.1.4.14,RFC1213-MIB::ipReasmReqds,Counter32,read-only,,mandatory,,The number of IP fragments received which needed to be reassembled at this entity. +.1.3.6.1.2.1.4.15,RFC1213-MIB::ipReasmOKs,Counter32,read-only,,mandatory,,The number of IP datagrams successfully re- assembled. +.1.3.6.1.2.1.4.16,RFC1213-MIB::ipReasmFails,Counter32,read-only,,mandatory,,The number of failures detected by the IP re- assembly algorithm (for whatever reason: timed out, errors, etc). Note that this is not necessarily a count of discarded IP fragments since some algorithms (notably the algorithm in RFC 815) can lose track of the number of fragments by combining them as they are received. +.1.3.6.1.2.1.4.17,RFC1213-MIB::ipFragOKs,Counter32,read-only,,mandatory,,The number of IP datagrams that have been successfully fragmented at this entity. +.1.3.6.1.2.1.4.18,RFC1213-MIB::ipFragFails,Counter32,read-only,,mandatory,,The number of IP datagrams that have been discarded because they needed to be fragmented at this entity but could not be, e.g., because their Don't Fragment flag was set. +.1.3.6.1.2.1.4.19,RFC1213-MIB::ipFragCreates,Counter32,read-only,,mandatory,,The number of IP datagram fragments that have been generated as a result of fragmentation at this entity. +.1.3.6.1.2.1.4.20,RFC1213-MIB::ipAddrTable,,not-accessible,,mandatory,,The table of addressing information relevant to this entity's IP addresses. +.1.3.6.1.2.1.4.20.1,RFC1213-MIB::ipAddrEntry,,not-accessible,ipAdEntAddr,mandatory,,The addressing information for one of this entity's IP addresses. +.1.3.6.1.2.1.4.20.1.1,RFC1213-MIB::ipAdEntAddr,IpAddress,read-only,,mandatory,,The IP address to which this entry's addressing information pertains. +.1.3.6.1.2.1.4.20.1.2,RFC1213-MIB::ipAdEntIfIndex,INTEGER,read-only,,mandatory,,The index value which uniquely identifies the interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex. +.1.3.6.1.2.1.4.20.1.3,RFC1213-MIB::ipAdEntNetMask,IpAddress,read-only,,mandatory,,The subnet mask associated with the IP address of this entry. The value of the mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0. +.1.3.6.1.2.1.4.20.1.4,RFC1213-MIB::ipAdEntBcastAddr,INTEGER,read-only,,mandatory,,The value of the least-significant bit in the IP broadcast address used for sending datagrams on the (logical) interface associated with the IP address of this entry. For example, when the Internet standard all-ones broadcast address is used, the value will be 1. This value applies to both the subnet and network broadcasts addresses used by the entity on this (logical) interface. +.1.3.6.1.2.1.4.20.1.5,RFC1213-MIB::ipAdEntReasmMaxSize,INTEGER,read-only,,mandatory,,The size of the largest IP datagram which this entity can re-assemble from incoming IP fragmented datagrams received on this interface. +.1.3.6.1.2.1.4.21,RFC1213-MIB::ipRouteTable,,not-accessible,,mandatory,,This entity's IP Routing table. +.1.3.6.1.2.1.4.21.1,RFC1213-MIB::ipRouteEntry,,not-accessible,ipRouteDest,mandatory,,A route to a particular destination. +.1.3.6.1.2.1.4.21.1.1,RFC1213-MIB::ipRouteDest,IpAddress,read-write,,mandatory,,The destination IP address of this route. An entry with a value of 0.0.0.0 is considered a default route. Multiple routes to a single destination can appear in the table, but access to such multiple entries is dependent on the table- access mechanisms defined by the network management protocol in use. +.1.3.6.1.2.1.4.21.1.2,RFC1213-MIB::ipRouteIfIndex,INTEGER,read-write,,mandatory,,The index value which uniquely identifies the local interface through which the next hop of this route should be reached. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex. +.1.3.6.1.2.1.4.21.1.3,RFC1213-MIB::ipRouteMetric1,INTEGER,read-write,,mandatory,,The primary routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1. +.1.3.6.1.2.1.4.21.1.4,RFC1213-MIB::ipRouteMetric2,INTEGER,read-write,,mandatory,,An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1. +.1.3.6.1.2.1.4.21.1.5,RFC1213-MIB::ipRouteMetric3,INTEGER,read-write,,mandatory,,An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1. +.1.3.6.1.2.1.4.21.1.6,RFC1213-MIB::ipRouteMetric4,INTEGER,read-write,,mandatory,,An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1. +.1.3.6.1.2.1.4.21.1.7,RFC1213-MIB::ipRouteNextHop,IpAddress,read-write,,mandatory,,The IP address of the next hop of this route. (In the case of a route bound to an interface which is realized via a broadcast media, the value of this field is the agent's IP address on that interface.) +.1.3.6.1.2.1.4.21.1.8,RFC1213-MIB::ipRouteType,INTEGER,read-write,,mandatory,other(1):invalid(2):direct(3):indirect(4),The type of route. Note that the values direct(3) and indirect(4) refer to the notion of direct and indirect routing in the IP architecture. Setting this object to the value invalid(2) has the effect of invalidating the corresponding entry in the ipRouteTable object. That is, it effectively dissasociates the destination identified with said entry from the route identified with said entry. It is an implementation-specific matter as to whether the agent removes an invalidated entry from the table. Accordingly, management stations must be prepared to receive tabular information from agents that corresponds to entries not currently in use. Proper interpretation of such entries requires examination of the relevant ipRouteType object. +.1.3.6.1.2.1.4.21.1.9,RFC1213-MIB::ipRouteProto,INTEGER,read-only,,mandatory,other(1):local(2):netmgmt(3):icmp(4):egp(5):ggp(6):hello(7):rip(8):is-is(9):es-is(10):ciscoIgrp(11):bbnSpfIgp(12):ospf(13):bgp(14),The routing mechanism via which this route was learned. Inclusion of values for gateway routing protocols is not intended to imply that hosts should support those protocols. +.1.3.6.1.2.1.4.21.1.10,RFC1213-MIB::ipRouteAge,INTEGER,read-write,,mandatory,,The number of seconds since this route was last updated or otherwise determined to be correct. Note that no semantics of `too old' can be implied except through knowledge of the routing protocol by which the route was learned. +.1.3.6.1.2.1.4.21.1.11,RFC1213-MIB::ipRouteMask,IpAddress,read-write,,mandatory,,Indicate the mask to be logical-ANDed with the destination address before being compared to the value in the ipRouteDest field. For those systems that do not support arbitrary subnet masks, an agent constructs the value of the ipRouteMask by determining whether the value of the correspondent ipRouteDest field belong to a class-A, B, or C network, and then using one of: mask network 255.0.0.0 class-A 255.255.0.0 class-B 255.255.255.0 class-C If the value of the ipRouteDest is 0.0.0.0 (a default route), then the mask value is also 0.0.0.0. It should be noted that all IP routing subsystems implicitly use this mechanism. +.1.3.6.1.2.1.4.21.1.12,RFC1213-MIB::ipRouteMetric5,INTEGER,read-write,,mandatory,,An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1. +.1.3.6.1.2.1.4.21.1.13,RFC1213-MIB::ipRouteInfo,OBJECT,read-only,,mandatory,,A reference to MIB definitions specific to the particular routing protocol which is responsible for this route, as determined by the value specified in the route's ipRouteProto value. If this information is not present, its value should be set to the OBJECT IDENTIFIER { 0 0 }, which is a syntatically valid object identifier, and any conformant implementation of ASN.1 and BER must be able to generate and recognize this value. +.1.3.6.1.2.1.4.22,RFC1213-MIB::ipNetToMediaTable,,not-accessible,,mandatory,,The IP Address Translation table used for mapping from IP addresses to physical addresses. +.1.3.6.1.2.1.4.22.1,RFC1213-MIB::ipNetToMediaEntry,,not-accessible,ipNetToMediaIfIndex:ipNetToMediaNetAddress,mandatory,,Each entry contains one IpAddress to `physical' address equivalence. +.1.3.6.1.2.1.4.22.1.1,RFC1213-MIB::ipNetToMediaIfIndex,INTEGER,read-write,,mandatory,,The interface on which this entry's equivalence is effective. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex. +.1.3.6.1.2.1.4.22.1.2,RFC1213-MIB::ipNetToMediaPhysAddress,OCTET,read-write,,mandatory,,The media-dependent `physical' address. +.1.3.6.1.2.1.4.22.1.3,RFC1213-MIB::ipNetToMediaNetAddress,IpAddress,read-write,,mandatory,,The IpAddress corresponding to the media- dependent `physical' address. +.1.3.6.1.2.1.4.22.1.4,RFC1213-MIB::ipNetToMediaType,INTEGER,read-write,,mandatory,other(1):invalid(2):dynamic(3):static(4),The type of mapping. Setting this object to the value invalid(2) has the effect of invalidating the corresponding entry in the ipNetToMediaTable. That is, it effectively dissasociates the interface identified with said entry from the mapping identified with said entry. It is an implementation-specific matter as to whether the agent removes an invalidated entry from the table. Accordingly, management stations must be prepared to receive tabular information from agents that corresponds to entries not currently in use. Proper interpretation of such entries requires examination of the relevant ipNetToMediaType object. +.1.3.6.1.2.1.4.23,RFC1213-MIB::ipRoutingDiscards,Counter32,read-only,,mandatory,,The number of routing entries which were chosen to be discarded even though they are valid. One possible reason for discarding such an entry could be to free-up buffer space for other routing entries. +.1.3.6.1.2.1.5,RFC1213-MIB::icmp,,,,,, +.1.3.6.1.2.1.5.1,RFC1213-MIB::icmpInMsgs,Counter32,read-only,,mandatory,,The total number of ICMP messages which the entity received. Note that this counter includes all those counted by icmpInErrors. +.1.3.6.1.2.1.5.2,RFC1213-MIB::icmpInErrors,Counter32,read-only,,mandatory,,The number of ICMP messages which the entity received but determined as having ICMP-specific errors (bad ICMP checksums, bad length, etc.). +.1.3.6.1.2.1.5.3,RFC1213-MIB::icmpInDestUnreachs,Counter32,read-only,,mandatory,,The number of ICMP Destination Unreachable messages received. +.1.3.6.1.2.1.5.4,RFC1213-MIB::icmpInTimeExcds,Counter32,read-only,,mandatory,,The number of ICMP Time Exceeded messages received. +.1.3.6.1.2.1.5.5,RFC1213-MIB::icmpInParmProbs,Counter32,read-only,,mandatory,,The number of ICMP Parameter Problem messages received. +.1.3.6.1.2.1.5.6,RFC1213-MIB::icmpInSrcQuenchs,Counter32,read-only,,mandatory,,The number of ICMP Source Quench messages received. +.1.3.6.1.2.1.5.7,RFC1213-MIB::icmpInRedirects,Counter32,read-only,,mandatory,,The number of ICMP Redirect messages received. +.1.3.6.1.2.1.5.8,RFC1213-MIB::icmpInEchos,Counter32,read-only,,mandatory,,The number of ICMP Echo (request) messages received. +.1.3.6.1.2.1.5.9,RFC1213-MIB::icmpInEchoReps,Counter32,read-only,,mandatory,,The number of ICMP Echo Reply messages received. +.1.3.6.1.2.1.5.10,RFC1213-MIB::icmpInTimestamps,Counter32,read-only,,mandatory,,The number of ICMP Timestamp (request) messages received. +.1.3.6.1.2.1.5.11,RFC1213-MIB::icmpInTimestampReps,Counter32,read-only,,mandatory,,The number of ICMP Timestamp Reply messages received. +.1.3.6.1.2.1.5.12,RFC1213-MIB::icmpInAddrMasks,Counter32,read-only,,mandatory,,The number of ICMP Address Mask Request messages received. +.1.3.6.1.2.1.5.13,RFC1213-MIB::icmpInAddrMaskReps,Counter32,read-only,,mandatory,,The number of ICMP Address Mask Reply messages received. +.1.3.6.1.2.1.5.14,RFC1213-MIB::icmpOutMsgs,Counter32,read-only,,mandatory,,The total number of ICMP messages which this entity attempted to send. Note that this counter includes all those counted by icmpOutErrors. +.1.3.6.1.2.1.5.15,RFC1213-MIB::icmpOutErrors,Counter32,read-only,,mandatory,,The number of ICMP messages which this entity did not send due to problems discovered within ICMP such as a lack of buffers. This value should not include errors discovered outside the ICMP layer such as the inability of IP to route the resultant datagram. In some implementations there may be no types of error which contribute to this counter's value. +.1.3.6.1.2.1.5.16,RFC1213-MIB::icmpOutDestUnreachs,Counter32,read-only,,mandatory,,The number of ICMP Destination Unreachable messages sent. +.1.3.6.1.2.1.5.17,RFC1213-MIB::icmpOutTimeExcds,Counter32,read-only,,mandatory,,The number of ICMP Time Exceeded messages sent. +.1.3.6.1.2.1.5.18,RFC1213-MIB::icmpOutParmProbs,Counter32,read-only,,mandatory,,The number of ICMP Parameter Problem messages sent. +.1.3.6.1.2.1.5.19,RFC1213-MIB::icmpOutSrcQuenchs,Counter32,read-only,,mandatory,,The number of ICMP Source Quench messages sent. +.1.3.6.1.2.1.5.20,RFC1213-MIB::icmpOutRedirects,Counter32,read-only,,mandatory,,The number of ICMP Redirect messages sent. For a host, this object will always be zero, since hosts do not send redirects. +.1.3.6.1.2.1.5.21,RFC1213-MIB::icmpOutEchos,Counter32,read-only,,mandatory,,The number of ICMP Echo (request) messages sent. +.1.3.6.1.2.1.5.22,RFC1213-MIB::icmpOutEchoReps,Counter32,read-only,,mandatory,,The number of ICMP Echo Reply messages sent. +.1.3.6.1.2.1.5.23,RFC1213-MIB::icmpOutTimestamps,Counter32,read-only,,mandatory,,The number of ICMP Timestamp (request) messages sent. +.1.3.6.1.2.1.5.24,RFC1213-MIB::icmpOutTimestampReps,Counter32,read-only,,mandatory,,The number of ICMP Timestamp Reply messages sent. +.1.3.6.1.2.1.5.25,RFC1213-MIB::icmpOutAddrMasks,Counter32,read-only,,mandatory,,The number of ICMP Address Mask Request messages sent. +.1.3.6.1.2.1.5.26,RFC1213-MIB::icmpOutAddrMaskReps,Counter32,read-only,,mandatory,,The number of ICMP Address Mask Reply messages sent. +.1.3.6.1.2.1.6,RFC1213-MIB::tcp,,,,,, +.1.3.6.1.2.1.6.1,RFC1213-MIB::tcpRtoAlgorithm,INTEGER,read-only,,mandatory,other(1):constant(2):rsre(3):vanj(4),The algorithm used to determine the timeout value used for retransmitting unacknowledged octets. +.1.3.6.1.2.1.6.2,RFC1213-MIB::tcpRtoMin,INTEGER,read-only,,mandatory,,The minimum value permitted by a TCP implementation for the retransmission timeout, measured in milliseconds. More refined semantics for objects of this type depend upon the algorithm used to determine the retransmission timeout. In particular, when the timeout algorithm is rsre(3), an object of this type has the semantics of the LBOUND quantity described in RFC 793. +.1.3.6.1.2.1.6.3,RFC1213-MIB::tcpRtoMax,INTEGER,read-only,,mandatory,,The maximum value permitted by a TCP implementation for the retransmission timeout, measured in milliseconds. More refined semantics for objects of this type depend upon the algorithm used to determine the retransmission timeout. In particular, when the timeout algorithm is rsre(3), an object of this type has the semantics of the UBOUND quantity described in RFC 793. +.1.3.6.1.2.1.6.4,RFC1213-MIB::tcpMaxConn,INTEGER,read-only,,mandatory,,The limit on the total number of TCP connections the entity can support. In entities where the maximum number of connections is dynamic, this object should contain the value -1. +.1.3.6.1.2.1.6.5,RFC1213-MIB::tcpActiveOpens,Counter32,read-only,,mandatory,,The number of times TCP connections have made a direct transition to the SYN-SENT state from the CLOSED state. +.1.3.6.1.2.1.6.6,RFC1213-MIB::tcpPassiveOpens,Counter32,read-only,,mandatory,,The number of times TCP connections have made a direct transition to the SYN-RCVD state from the LISTEN state. +.1.3.6.1.2.1.6.7,RFC1213-MIB::tcpAttemptFails,Counter32,read-only,,mandatory,,The number of times TCP connections have made a direct transition to the CLOSED state from either the SYN-SENT state or the SYN-RCVD state, plus the number of times TCP connections have made a direct transition to the LISTEN state from the SYN-RCVD state. +.1.3.6.1.2.1.6.8,RFC1213-MIB::tcpEstabResets,Counter32,read-only,,mandatory,,The number of times TCP connections have made a direct transition to the CLOSED state from either the ESTABLISHED state or the CLOSE-WAIT state. +.1.3.6.1.2.1.6.9,RFC1213-MIB::tcpCurrEstab,Gauge32,read-only,,mandatory,,The number of TCP connections for which the current state is either ESTABLISHED or CLOSE- WAIT. +.1.3.6.1.2.1.6.10,RFC1213-MIB::tcpInSegs,Counter32,read-only,,mandatory,,The total number of segments received, including those received in error. This count includes segments received on currently established connections. +.1.3.6.1.2.1.6.11,RFC1213-MIB::tcpOutSegs,Counter32,read-only,,mandatory,,The total number of segments sent, including those on current connections but excluding those containing only retransmitted octets. +.1.3.6.1.2.1.6.12,RFC1213-MIB::tcpRetransSegs,Counter32,read-only,,mandatory,,The total number of segments retransmitted - that is, the number of TCP segments transmitted containing one or more previously transmitted octets. +.1.3.6.1.2.1.6.13,RFC1213-MIB::tcpConnTable,,not-accessible,,mandatory,,A table containing TCP connection-specific information. +.1.3.6.1.2.1.6.13.1,RFC1213-MIB::tcpConnEntry,,not-accessible,tcpConnLocalAddress:tcpConnLocalPort:tcpConnRemAddress:tcpConnRemPort,mandatory,,Information about a particular current TCP connection. An object of this type is transient, in that it ceases to exist when (or soon after) the connection makes the transition to the CLOSED state. +.1.3.6.1.2.1.6.13.1.1,RFC1213-MIB::tcpConnState,INTEGER,read-write,,mandatory,closed(1):listen(2):synSent(3):synReceived(4):established(5):finWait1(6):finWait2(7):closeWait(8):lastAck(9):closing(10):timeWait(11):deleteTCB(12),The state of this TCP connection. The only value which may be set by a management station is deleteTCB(12). Accordingly, it is appropriate for an agent to return a `badValue' response if a management station attempts to set this object to any other value. If a management station sets this object to the value deleteTCB(12), then this has the effect of deleting the TCB (as defined in RFC 793) of the corresponding connection on the managed node, resulting in immediate termination of the connection. As an implementation-specific option, a RST segment may be sent from the managed node to the other TCP endpoint (note however that RST segments are not sent reliably). +.1.3.6.1.2.1.6.13.1.2,RFC1213-MIB::tcpConnLocalAddress,IpAddress,read-only,,mandatory,,The local IP address for this TCP connection. In the case of a connection in the listen state which is willing to accept connections for any IP interface associated with the node, the value 0.0.0.0 is used. +.1.3.6.1.2.1.6.13.1.3,RFC1213-MIB::tcpConnLocalPort,INTEGER,read-only,,mandatory,,The local port number for this TCP connection. +.1.3.6.1.2.1.6.13.1.4,RFC1213-MIB::tcpConnRemAddress,IpAddress,read-only,,mandatory,,The remote IP address for this TCP connection. +.1.3.6.1.2.1.6.13.1.5,RFC1213-MIB::tcpConnRemPort,INTEGER,read-only,,mandatory,,The remote port number for this TCP connection. +.1.3.6.1.2.1.6.14,RFC1213-MIB::tcpInErrs,Counter32,read-only,,mandatory,,The total number of segments received in error (e.g., bad TCP checksums). +.1.3.6.1.2.1.6.15,RFC1213-MIB::tcpOutRsts,Counter32,read-only,,mandatory,,The number of TCP segments sent containing the RST flag. +.1.3.6.1.2.1.7,RFC1213-MIB::udp,,,,,, +.1.3.6.1.2.1.7.1,RFC1213-MIB::udpInDatagrams,Counter32,read-only,,mandatory,,The total number of UDP datagrams delivered to UDP users. +.1.3.6.1.2.1.7.2,RFC1213-MIB::udpNoPorts,Counter32,read-only,,mandatory,,The total number of received UDP datagrams for which there was no application at the destination port. +.1.3.6.1.2.1.7.3,RFC1213-MIB::udpInErrors,Counter32,read-only,,mandatory,,The number of received UDP datagrams that could not be delivered for reasons other than the lack of an application at the destination port. +.1.3.6.1.2.1.7.4,RFC1213-MIB::udpOutDatagrams,Counter32,read-only,,mandatory,,The total number of UDP datagrams sent from this entity. +.1.3.6.1.2.1.7.5,RFC1213-MIB::udpTable,,not-accessible,,mandatory,,A table containing UDP listener information. +.1.3.6.1.2.1.7.5.1,RFC1213-MIB::udpEntry,,not-accessible,udpLocalAddress:udpLocalPort,mandatory,,Information about a particular current UDP listener. +.1.3.6.1.2.1.7.5.1.1,RFC1213-MIB::udpLocalAddress,IpAddress,read-only,,mandatory,,The local IP address for this UDP listener. In the case of a UDP listener which is willing to accept datagrams for any IP interface associated with the node, the value 0.0.0.0 is used. +.1.3.6.1.2.1.7.5.1.2,RFC1213-MIB::udpLocalPort,INTEGER,read-only,,mandatory,,The local port number for this UDP listener. +.1.3.6.1.2.1.8,RFC1213-MIB::egp,,,,,, +.1.3.6.1.2.1.8.1,RFC1213-MIB::egpInMsgs,Counter32,read-only,,mandatory,,The number of EGP messages received without error. +.1.3.6.1.2.1.8.2,RFC1213-MIB::egpInErrors,Counter32,read-only,,mandatory,,The number of EGP messages received that proved to be in error. +.1.3.6.1.2.1.8.3,RFC1213-MIB::egpOutMsgs,Counter32,read-only,,mandatory,,The total number of locally generated EGP messages. +.1.3.6.1.2.1.8.4,RFC1213-MIB::egpOutErrors,Counter32,read-only,,mandatory,,The number of locally generated EGP messages not sent due to resource limitations within an EGP entity. +.1.3.6.1.2.1.8.5,RFC1213-MIB::egpNeighTable,,not-accessible,,mandatory,,The EGP neighbor table. +.1.3.6.1.2.1.8.5.1,RFC1213-MIB::egpNeighEntry,,not-accessible,egpNeighAddr,mandatory,,Information about this entity's relationship with a particular EGP neighbor. +.1.3.6.1.2.1.8.5.1.1,RFC1213-MIB::egpNeighState,INTEGER,read-only,,mandatory,idle(1):acquisition(2):down(3):up(4):cease(5),The EGP state of the local system with respect to this entry's EGP neighbor. Each EGP state is represented by a value that is one greater than the numerical value associated with said state in RFC 904. +.1.3.6.1.2.1.8.5.1.2,RFC1213-MIB::egpNeighAddr,IpAddress,read-only,,mandatory,,The IP address of this entry's EGP neighbor. +.1.3.6.1.2.1.8.5.1.3,RFC1213-MIB::egpNeighAs,INTEGER,read-only,,mandatory,,The autonomous system of this EGP peer. Zero should be specified if the autonomous system number of the neighbor is not yet known. +.1.3.6.1.2.1.8.5.1.4,RFC1213-MIB::egpNeighInMsgs,Counter32,read-only,,mandatory,,The number of EGP messages received without error from this EGP peer. +.1.3.6.1.2.1.8.5.1.5,RFC1213-MIB::egpNeighInErrs,Counter32,read-only,,mandatory,,The number of EGP messages received from this EGP peer that proved to be in error (e.g., bad EGP checksum). +.1.3.6.1.2.1.8.5.1.6,RFC1213-MIB::egpNeighOutMsgs,Counter32,read-only,,mandatory,,The number of locally generated EGP messages to this EGP peer. +.1.3.6.1.2.1.8.5.1.7,RFC1213-MIB::egpNeighOutErrs,Counter32,read-only,,mandatory,,The number of locally generated EGP messages not sent to this EGP peer due to resource limitations within an EGP entity. +.1.3.6.1.2.1.8.5.1.8,RFC1213-MIB::egpNeighInErrMsgs,Counter32,read-only,,mandatory,,The number of EGP-defined error messages received from this EGP peer. +.1.3.6.1.2.1.8.5.1.9,RFC1213-MIB::egpNeighOutErrMsgs,Counter32,read-only,,mandatory,,The number of EGP-defined error messages sent to this EGP peer. +.1.3.6.1.2.1.8.5.1.10,RFC1213-MIB::egpNeighStateUps,Counter32,read-only,,mandatory,,The number of EGP state transitions to the UP state with this EGP peer. +.1.3.6.1.2.1.8.5.1.11,RFC1213-MIB::egpNeighStateDowns,Counter32,read-only,,mandatory,,The number of EGP state transitions from the UP state to any other state with this EGP peer. +.1.3.6.1.2.1.8.5.1.12,RFC1213-MIB::egpNeighIntervalHello,INTEGER,read-only,,mandatory,,The interval between EGP Hello command retransmissions (in hundredths of a second). This represents the t1 timer as defined in RFC 904. +.1.3.6.1.2.1.8.5.1.13,RFC1213-MIB::egpNeighIntervalPoll,INTEGER,read-only,,mandatory,,The interval between EGP poll command retransmissions (in hundredths of a second). This represents the t3 timer as defined in RFC 904. +.1.3.6.1.2.1.8.5.1.14,RFC1213-MIB::egpNeighMode,INTEGER,read-only,,mandatory,active(1):passive(2),The polling mode of this EGP entity, either passive or active. +.1.3.6.1.2.1.8.5.1.15,RFC1213-MIB::egpNeighEventTrigger,INTEGER,read-write,,mandatory,start(1):stop(2),A control variable used to trigger operator- initiated Start and Stop events. When read, this variable always returns the most recent value that egpNeighEventTrigger was set to. If it has not been set since the last initialization of the network management subsystem on the node, it returns a value of `stop'. When set, this variable causes a Start or Stop event on the specified neighbor, as specified on pages 8-10 of RFC 904. Briefly, a Start event causes an Idle peer to begin neighbor acquisition and a non-Idle peer to reinitiate neighbor acquisition. A stop event causes a non-Idle peer to return to the Idle state until a Start event occurs, either via egpNeighEventTrigger or otherwise. +.1.3.6.1.2.1.8.6,RFC1213-MIB::egpAs,INTEGER,read-only,,mandatory,,The autonomous system number of this EGP entity. +.1.3.6.1.2.1.10,SNMPv2-SMI::transmission,,,,,, +.1.3.6.1.2.1.11,RFC1213-MIB::snmp,,,,,, +.1.3.6.1.2.1.11.1,RFC1213-MIB::snmpInPkts,Counter32,read-only,,mandatory,,The total number of Messages delivered to the SNMP entity from the transport service. +.1.3.6.1.2.1.11.2,RFC1213-MIB::snmpOutPkts,Counter32,read-only,,mandatory,,The total number of SNMP Messages which were passed from the SNMP protocol entity to the transport service. +.1.3.6.1.2.1.11.3,RFC1213-MIB::snmpInBadVersions,Counter32,read-only,,mandatory,,The total number of SNMP Messages which were delivered to the SNMP protocol entity and were for an unsupported SNMP version. +.1.3.6.1.2.1.11.4,RFC1213-MIB::snmpInBadCommunityNames,Counter32,read-only,,mandatory,,The total number of SNMP Messages delivered to the SNMP protocol entity which used a SNMP community name not known to said entity. +.1.3.6.1.2.1.11.5,RFC1213-MIB::snmpInBadCommunityUses,Counter32,read-only,,mandatory,,The total number of SNMP Messages delivered to the SNMP protocol entity which represented an SNMP operation which was not allowed by the SNMP community named in the Message. +.1.3.6.1.2.1.11.6,RFC1213-MIB::snmpInASNParseErrs,Counter32,read-only,,mandatory,,The total number of ASN.1 or BER errors encountered by the SNMP protocol entity when decoding received SNMP Messages. +.1.3.6.1.2.1.11.8,RFC1213-MIB::snmpInTooBigs,Counter32,read-only,,mandatory,,The total number of SNMP PDUs which were delivered to the SNMP protocol entity and for which the value of the error-status field is `tooBig'. +.1.3.6.1.2.1.11.9,RFC1213-MIB::snmpInNoSuchNames,Counter32,read-only,,mandatory,,The total number of SNMP PDUs which were delivered to the SNMP protocol entity and for which the value of the error-status field is `noSuchName'. +.1.3.6.1.2.1.11.10,RFC1213-MIB::snmpInBadValues,Counter32,read-only,,mandatory,,The total number of SNMP PDUs which were delivered to the SNMP protocol entity and for which the value of the error-status field is `badValue'. +.1.3.6.1.2.1.11.11,RFC1213-MIB::snmpInReadOnlys,Counter32,read-only,,mandatory,,The total number valid SNMP PDUs which were delivered to the SNMP protocol entity and for which the value of the error-status field is `readOnly'. It should be noted that it is a protocol error to generate an SNMP PDU which contains the value `readOnly' in the error-status field, as such this object is provided as a means of detecting incorrect implementations of the SNMP. +.1.3.6.1.2.1.11.12,RFC1213-MIB::snmpInGenErrs,Counter32,read-only,,mandatory,,The total number of SNMP PDUs which were delivered to the SNMP protocol entity and for which the value of the error-status field is `genErr'. +.1.3.6.1.2.1.11.13,RFC1213-MIB::snmpInTotalReqVars,Counter32,read-only,,mandatory,,The total number of MIB objects which have been retrieved successfully by the SNMP protocol entity as the result of receiving valid SNMP Get-Request and Get-Next PDUs. +.1.3.6.1.2.1.11.14,RFC1213-MIB::snmpInTotalSetVars,Counter32,read-only,,mandatory,,The total number of MIB objects which have been altered successfully by the SNMP protocol entity as the result of receiving valid SNMP Set-Request PDUs. +.1.3.6.1.2.1.11.15,RFC1213-MIB::snmpInGetRequests,Counter32,read-only,,mandatory,,The total number of SNMP Get-Request PDUs which have been accepted and processed by the SNMP protocol entity. +.1.3.6.1.2.1.11.16,RFC1213-MIB::snmpInGetNexts,Counter32,read-only,,mandatory,,The total number of SNMP Get-Next PDUs which have been accepted and processed by the SNMP protocol entity. +.1.3.6.1.2.1.11.17,RFC1213-MIB::snmpInSetRequests,Counter32,read-only,,mandatory,,The total number of SNMP Set-Request PDUs which have been accepted and processed by the SNMP protocol entity. +.1.3.6.1.2.1.11.18,RFC1213-MIB::snmpInGetResponses,Counter32,read-only,,mandatory,,The total number of SNMP Get-Response PDUs which have been accepted and processed by the SNMP protocol entity. +.1.3.6.1.2.1.11.19,RFC1213-MIB::snmpInTraps,Counter32,read-only,,mandatory,,The total number of SNMP Trap PDUs which have been accepted and processed by the SNMP protocol entity. +.1.3.6.1.2.1.11.20,RFC1213-MIB::snmpOutTooBigs,Counter32,read-only,,mandatory,,The total number of SNMP PDUs which were generated by the SNMP protocol entity and for which the value of the error-status field is `tooBig.' +.1.3.6.1.2.1.11.21,RFC1213-MIB::snmpOutNoSuchNames,Counter32,read-only,,mandatory,,The total number of SNMP PDUs which were generated by the SNMP protocol entity and for which the value of the error-status is `noSuchName'. +.1.3.6.1.2.1.11.22,RFC1213-MIB::snmpOutBadValues,Counter32,read-only,,mandatory,,The total number of SNMP PDUs which were generated by the SNMP protocol entity and for which the value of the error-status field is `badValue'. +.1.3.6.1.2.1.11.24,RFC1213-MIB::snmpOutGenErrs,Counter32,read-only,,mandatory,,The total number of SNMP PDUs which were generated by the SNMP protocol entity and for which the value of the error-status field is `genErr'. +.1.3.6.1.2.1.11.25,RFC1213-MIB::snmpOutGetRequests,Counter32,read-only,,mandatory,,The total number of SNMP Get-Request PDUs which have been generated by the SNMP protocol entity. +.1.3.6.1.2.1.11.26,RFC1213-MIB::snmpOutGetNexts,Counter32,read-only,,mandatory,,The total number of SNMP Get-Next PDUs which have been generated by the SNMP protocol entity. +.1.3.6.1.2.1.11.27,RFC1213-MIB::snmpOutSetRequests,Counter32,read-only,,mandatory,,The total number of SNMP Set-Request PDUs which have been generated by the SNMP protocol entity. +.1.3.6.1.2.1.11.28,RFC1213-MIB::snmpOutGetResponses,Counter32,read-only,,mandatory,,The total number of SNMP Get-Response PDUs which have been generated by the SNMP protocol entity. +.1.3.6.1.2.1.11.29,RFC1213-MIB::snmpOutTraps,Counter32,read-only,,mandatory,,The total number of SNMP Trap PDUs which have been generated by the SNMP protocol entity. +.1.3.6.1.2.1.11.30,RFC1213-MIB::snmpEnableAuthenTraps,INTEGER,read-write,,mandatory,enabled(1):disabled(2),Indicates whether the SNMP agent process is permitted to generate authentication-failure traps. The value of this object overrides any configuration information; as such, it provides a means whereby all authentication-failure traps may be disabled. Note that it is strongly recommended that this object be stored in non-volatile memory so that it remains constant between re-initializations of the network management system. +.1.3.6.1.2.1.30,IANAifType-MIB::ianaifType,,,,,,This MIB module defines the IANAifType Textual Convention, and thus the enumerated values of the ifType object defined in MIB-II's ifTable. +.1.3.6.1.3,RFC1155-SMI::experimental,,,,,, +.1.3.6.1.4,RFC1155-SMI::private,,,,,, +.1.3.6.1.4.1,RFC1155-SMI::enterprises,,,,,, +.1.3.6.1.4.1.4458,RADWIN-MIB-WINLINK1000::radwin,,,,,, +.1.3.6.1.4.1.4458.20,RADWIN-MIB-WINLINK1000::radwinProducts,,,,,, +.1.3.6.1.4.1.4458.20.2,RADWIN-MIB-WINLINK1000::winlink1000Family,,,,,, +.1.3.6.1.4.1.4458.20.2.1,RADWIN-MIB-WINLINK1000::odu,,,,,, +.1.3.6.1.4.1.4458.20.2.1.1,RADWIN-MIB-WINLINK1000::oduIntegratedAntenna,,,,,, +.1.3.6.1.4.1.4458.20.2.1.2,RADWIN-MIB-WINLINK1000::oduExternalAntenna,,,,,, +.1.3.6.1.4.1.4458.20.3,RADWIN-MIB-WINLINK1000::radwin2000Family,,,,,, +.1.3.6.1.4.1.4458.20.3.1,RADWIN-MIB-WINLINK1000::odu2000,,,,,, +.1.3.6.1.4.1.4458.20.3.1.1,RADWIN-MIB-WINLINK1000::odu2KIntegratedAntenna,,,,,, +.1.3.6.1.4.1.4458.20.3.1.2,RADWIN-MIB-WINLINK1000::odu2KExternalAntenna,,,,,, +.1.3.6.1.4.1.4458.20.4,RADWIN-MIB-WINLINK1000::gpsSynchronizerFamily,,,,,, +.1.3.6.1.4.1.4458.20.4.1,RADWIN-MIB-WINLINK1000::oduGSU,,,,,, +.1.3.6.1.4.1.4458.20.4.1.2,RADWIN-MIB-WINLINK1000::oduGSUExternalAntenna,,,,,, +.1.3.6.1.4.1.4458.20.4.2,RADWIN-MIB-WINLINK1000::hssSyncUnits,,,,,, +.1.3.6.1.4.1.4458.20.4.2.1,RADWIN-MIB-WINLINK1000::hssISU,,,,,, +.1.3.6.1.4.1.4458.20.4.2.2,RADWIN-MIB-WINLINK1000::hssGSU,,,,,, +.1.3.6.1.4.1.4458.20.5,RADWIN-MIB-WINLINK1000::radwin5000HBSFamily,,,,,, +.1.3.6.1.4.1.4458.20.5.1,RADWIN-MIB-WINLINK1000::oduHBS,,,,,, +.1.3.6.1.4.1.4458.20.5.1.1,RADWIN-MIB-WINLINK1000::oduHBSIntegratedAntenna,,,,,, +.1.3.6.1.4.1.4458.20.5.1.2,RADWIN-MIB-WINLINK1000::oduHBSExternalAntenna,,,,,, +.1.3.6.1.4.1.4458.20.5.1.3,RADWIN-MIB-WINLINK1000::oduHBSEmbeddedAntenna,,,,,, +.1.3.6.1.4.1.4458.20.6,RADWIN-MIB-WINLINK1000::radwin5000HSUFamily,,,,,, +.1.3.6.1.4.1.4458.20.6.1,RADWIN-MIB-WINLINK1000::oduHSU,,,,,, +.1.3.6.1.4.1.4458.20.6.1.1,RADWIN-MIB-WINLINK1000::oduHSUIntegratedAntenna,,,,,, +.1.3.6.1.4.1.4458.20.6.1.2,RADWIN-MIB-WINLINK1000::oduHSUExternalAntenna,,,,,, +.1.3.6.1.4.1.4458.20.6.1.3,RADWIN-MIB-WINLINK1000::oduHSUEmbeddedAntenna,,,,,, +.1.3.6.1.4.1.4458.20.10,RADWIN-MIB-WINLINK1000::radwin6000Family,,,,,, +.1.3.6.1.4.1.4458.20.10.1,RADWIN-MIB-WINLINK1000::odu6000,,,,,, +.1.3.6.1.4.1.4458.20.10.1.1,RADWIN-MIB-WINLINK1000::odu6K,,,,,, +.1.3.6.1.4.1.4458.20.10.2,RADWIN-MIB-WINLINK1000::gateway6000,,,,,, +.1.3.6.1.4.1.4458.20.10.2.1,RADWIN-MIB-WINLINK1000::gateway6K,,,,,, +.1.3.6.1.4.1.4458.20.20,RADWIN-MIB-WINLINK1000::radwinWiFiAPFamily,,,,,, +.1.3.6.1.4.1.4458.20.20.1,RADWIN-MIB-WINLINK1000::odu600,,,,,, +.1.3.6.1.4.1.4458.20.20.1.1,RADWIN-MIB-WINLINK1000::oduWiFiAP,,,,,, +.1.3.6.1.4.1.4458.20.30,RADWIN-MIB-WINLINK1000::radwinSmartNodeFamily,,,,,, +.1.3.6.1.4.1.4458.20.30.1,RADWIN-MIB-WINLINK1000::smartNode,,,,,, +.1.3.6.1.4.1.4458.20.40,RADWIN-MIB-WINLINK1000::radwinNetworkingFamiliy,,,,,, +.1.3.6.1.4.1.4458.20.40.1,RADWIN-MIB-WINLINK1000::iduS,,,,,, +.1.3.6.1.4.1.4458.20.40.2,RADWIN-MIB-WINLINK1000::oduS,,,,,, +.1.3.6.1.4.1.4458.1000,RADWIN-MIB-WINLINK1000::winlink1000,,,,,, +.1.3.6.1.4.1.4458.1000.0,RADWIN-MIB-WINLINK1000::winlink1000#,,,,,, +.1.3.6.1.4.1.4458.1000.0.1,RADWIN-MIB-WINLINK1000::trunkStateChanged,,,,,, Indicates a change in the state of one of the TDM trunks. Raised by both sides of the link. Contains 3 parameters: 1 - Description: TDM Interface %n - %x 2 - %n: Is the trunk number 3 - %x: Is the alarm type and can be one of the following: Normal, AIS, LOS, Loopback +.1.3.6.1.4.1.4458.1000.0.2,RADWIN-MIB-WINLINK1000::linkUp,,,,,, Indicates that the radio link is up. Contains a single parameter, which is its description: 1 - Description: Radio Link - Sync on channel %n GHz. %n Is the channel frequency in GHz. +.1.3.6.1.4.1.4458.1000.0.3,RADWIN-MIB-WINLINK1000::linkDown,,,,,, Indicates that the radio link is down. Contains a single parameter, which is its description: 1 - Description: Radio Link - Out of Sync. The reason is: %s. %s Is the reason. +.1.3.6.1.4.1.4458.1000.0.4,RADWIN-MIB-WINLINK1000::detectIDU,,,,,, Indicates that the IDU was detected. Raised by both sides of the link. Contains a single parameter, which is its description: 1 - Description: IDU of Type %s was Detected. %s Is the type of the IDU. +.1.3.6.1.4.1.4458.1000.0.5,RADWIN-MIB-WINLINK1000::disconnectIDU,,,,,, Indicates that the IDU was disconnected. Raised by both sides of the link. Contains a single parameter, which is its description: 1 - Description: IDU Disconnected. +.1.3.6.1.4.1.4458.1000.0.6,RADWIN-MIB-WINLINK1000::mismatchIDU,,,,,, Indicates a mismatch between the IDUs. Raised by the master only. Contains a single parameter, which is its description: 1 - Description: IDUs Mismatch: One Side is %s and the Other is %s. %s Is the type of the IDU. +.1.3.6.1.4.1.4458.1000.0.7,RADWIN-MIB-WINLINK1000::openedServices,,,,,, Indicates that services were opened. Raised by the master only. Contains 3 parameters: 1 - Description: %n2 out of %n1 Requested TDM Trunks have been Opened 2 - %n1: Is the requested number of TDM truncks 3 - %n2: Is the actual number of TDM trunks that were opened +.1.3.6.1.4.1.4458.1000.0.8,RADWIN-MIB-WINLINK1000::closedServices,,,,,, Indicates that services were closed. Raised by the master only. Contains a single parameter, which is its description: 1 - Description: TDM Service has been closed. The reason is: %s. %s Is the reason. +.1.3.6.1.4.1.4458.1000.0.9,RADWIN-MIB-WINLINK1000::incompatibleODUs,,,,,, Indicates that the ODUs are incompatible. Contains a single parameter, which is its description: 1 - Description: Incompatible ODUs. +.1.3.6.1.4.1.4458.1000.0.10,RADWIN-MIB-WINLINK1000::incompatibleIDUs,,,,,, Indicates that the IDUs are incompatible. Contains a single parameter, which is its description: 1 - Description: Incompatible IDUs. +.1.3.6.1.4.1.4458.1000.0.11,RADWIN-MIB-WINLINK1000::incompatibleOduIdu,,,,,, Indicates that the ODU and IDU are incompatible. Contains a single parameter, which is its description: 1 - Description: The IDU could not be loaded. The reason is: %s. %s Is the incompatibility type. +.1.3.6.1.4.1.4458.1000.0.12,RADWIN-MIB-WINLINK1000::probingChannel,,,,,, Indicates that the ODU is monitoring radar activity. Contains a single parameter, which is its description: 1 - Description: Monitoring for radar activity on channel %n GHz. %n is the channel frequency in GHz. +.1.3.6.1.4.1.4458.1000.0.13,RADWIN-MIB-WINLINK1000::radarDetected,,,,,, Indicates that radar activity was detected. Contains a single parameter, which is its description: 1 - Description: Radar activity was detected in %s, on channel %n GHz. %s Is the site name. %n Is the channel frequency in GHz. +.1.3.6.1.4.1.4458.1000.0.14,RADWIN-MIB-WINLINK1000::transmittingOnChannel,,,,,, Indicates that the ODU is transmitting on channel. Contains a single parameter, which is its description: 1 - Description: Transmitting on channel %n GHz. %n Is the channel frequency in GHz. +.1.3.6.1.4.1.4458.1000.0.15,RADWIN-MIB-WINLINK1000::scanningChannels,,,,,, Indicates that the ODU is scanning channels. Contains a single parameter, which is its description: 1 - Description: Channel scanning in progress. +.1.3.6.1.4.1.4458.1000.0.16,RADWIN-MIB-WINLINK1000::incompatiblePartner,,,,,, Indicates that configuration problem was detected and that link installation is required in order to fix it. Contains a single parameter, which is its description: 1 - Description: Configuration problem detected. Link installation required. +.1.3.6.1.4.1.4458.1000.0.17,RADWIN-MIB-WINLINK1000::timeClockSet,,,,,, Indicates that the ODU time clock was set. Contains a single parameter, which is its description: 1 - Description: The time was set to: %p. %p Is the date and time. +.1.3.6.1.4.1.4458.1000.0.18,RADWIN-MIB-WINLINK1000::configurationChanged,,,,,, Indicates that the ODU recovered from an error, but there are configuration changes. Contains two parameters: 1 - Description: Configuration changed. Error code is: %n. 2 - %n number. +.1.3.6.1.4.1.4458.1000.0.19,RADWIN-MIB-WINLINK1000::hssOpStateChangedToINU,,,,,, Indicates that the HSS operating state was changed to INU type. Contains a single parameter, which is its description: 1 - Description: HSS operating state was changed to: INU. +.1.3.6.1.4.1.4458.1000.0.20,RADWIN-MIB-WINLINK1000::hssOpStateChangedToHSM,,,,,, Indicates that the HSS operating state was changed to HSM type. Contains a single parameter, which is its description: 1 - Description: HSS operating state was changed to: HSM. +.1.3.6.1.4.1.4458.1000.0.21,RADWIN-MIB-WINLINK1000::hssOpStateChangedToHSC,,,,,, Indicates that the HSS operating state was changed to HSC type. Contains a single parameter, which is its description: 1 - Description: HSS operating state was changed to: HSC_DT/HSC_CT. +.1.3.6.1.4.1.4458.1000.0.22,RADWIN-MIB-WINLINK1000::vlanModeActive,,,,,, Indicates to non-VLAN PC that after 2 minutes the system will support only VLAN tag on management interface. Contains a single parameter, which is its description: 1 - Description: VLAN Mode is active. Non-VLAN traffic will be blocked in 2 minutes. +.1.3.6.1.4.1.4458.1000.0.23,RADWIN-MIB-WINLINK1000::spectrumAnalysis,,,,,, Indicates that the ODU is in Spectrum Analysis mode. Contains a single parameter, which is its description: 1 - Description: Spectrum analysis in progress. +.1.3.6.1.4.1.4458.1000.0.24,RADWIN-MIB-WINLINK1000::hbsHsuDeregisteredOffline,,,,,, Indicates that a HSU was deregistered offline (out of link) +.1.3.6.1.4.1.4458.1000.0.25,RADWIN-MIB-WINLINK1000::hbsHsuDeregisteredSuccessfully,,,,,, Indicates that a HSU was deregistered successfully +.1.3.6.1.4.1.4458.1000.0.26,RADWIN-MIB-WINLINK1000::hbsHsuRegisteredSuccessfully,,,,,, Indicates that a HSU was registered successfully +.1.3.6.1.4.1.4458.1000.0.27,RADWIN-MIB-WINLINK1000::hbsHsuRegistrationFailed,,,,,, Indicates that registration has failed +.1.3.6.1.4.1.4458.1000.0.28,RADWIN-MIB-WINLINK1000::hbsHsuViolatedState,,,,,, Indicates (on the HBS side) that a HSU is violated state +.1.3.6.1.4.1.4458.1000.0.29,RADWIN-MIB-WINLINK1000::hsuViolatedState,,,,,, Indicates (on the HSU side) that the HSU is violated state +.1.3.6.1.4.1.4458.1000.0.30,RADWIN-MIB-WINLINK1000::hbsUnregisteredSynchronizedHsu,,,,,, Indicates an unregistered HSU has been synchronized. +.1.3.6.1.4.1.4458.1000.0.31,RADWIN-MIB-WINLINK1000::hbsUnregisteredUnsynchronizedHsu,,,,,, Indicates an unregistered HSU lost synchronization. +.1.3.6.1.4.1.4458.1000.0.32,RADWIN-MIB-WINLINK1000::cableQuality,,,,,, 1Gbps rate is not supported due to bad line quality. +.1.3.6.1.4.1.4458.1000.0.33,RADWIN-MIB-WINLINK1000::httpAuthentication,,,,,, HTTP Authentication Failure. +.1.3.6.1.4.1.4458.1000.0.34,RADWIN-MIB-WINLINK1000::telnetAuthentication,,,,,, Telnet Authentication Failure. +.1.3.6.1.4.1.4458.1000.0.100,RADWIN-MIB-WINLINK1000::tdmServiceAlarm,,,,,, Indicates that TDM Service is in alarm state. Contains a single parameter, which is its description: 1 - Description: TDM Service - Alarm. +.1.3.6.1.4.1.4458.1000.0.101,RADWIN-MIB-WINLINK1000::ethServiceClosed,,,,,, Indicates that Ethernet Service is closed. Contains a single parameter, which is its description: 1 - Description: Ethernet Service is closed. +.1.3.6.1.4.1.4458.1000.0.102,RADWIN-MIB-WINLINK1000::ethServiceNotPermitted,,,,,, Indicates that Ethernet Service is not permitted. Contains a single parameter, which is its description: 1 - Description: A valid IDU could not be detected at %s. Please check your configuration. %s - Is the Local Site name or Remote Site name or both sides of the Link. +.1.3.6.1.4.1.4458.1000.0.103,RADWIN-MIB-WINLINK1000::encryptionAlarm,,,,,, Indicates an encryption key mismatch. Contains a single parameter, which is its description: 1 - Description: Encryption Status - Failed. No Services are available. +.1.3.6.1.4.1.4458.1000.0.104,RADWIN-MIB-WINLINK1000::changeLinkPasswordAlarm,,,,,, Indicates that a failure has occurred while attempting to change the Link Password. Contains a single parameter, which is its description: 1 - Description: Failed to change the Link Password at/on: %s. %s - Is the Local Site name or Remote Site name or both sides of the Link. +.1.3.6.1.4.1.4458.1000.0.105,RADWIN-MIB-WINLINK1000::externalAlarmInPort1Alarm,,,,,, The trap is sent every time an alarm occurs in the External Alarm Input of port #1. Contains a single parameter, which is its description: 1 - Description: External Alarm 1 - - Alarm. +.1.3.6.1.4.1.4458.1000.0.106,RADWIN-MIB-WINLINK1000::externalAlarmInPort2Alarm,,,,,, The trap is sent every time an alarm occurs in the External Alarm Input of port #2. Contains a single parameter, which is its description: 1 - Description: External Alarm 2 - - Alarm. +.1.3.6.1.4.1.4458.1000.0.107,RADWIN-MIB-WINLINK1000::bitFailedAlarm,,,,,, The trap is sent if there is no way to recover from the situation. Contains two parameters: 1 - Description: ODU power up built in test failed. Error code is: %n 2 - %n number +.1.3.6.1.4.1.4458.1000.0.108,RADWIN-MIB-WINLINK1000::wrongConfigurationLoadedAlarm,,,,,, The trap is sent if there is a way to recover from the situation. Contains two parameters: 1 - Description: Wrong configuration loaded. Error code is: %n 2 - %n number +.1.3.6.1.4.1.4458.1000.0.109,RADWIN-MIB-WINLINK1000::lanPort1DisconnectedAlarm,,,,,, Indicates the LAN port 1 status changed to disconnected. Contains a single parameter, which is its description: 1 - Description: LAN port 1 status changed to disconnected. +.1.3.6.1.4.1.4458.1000.0.110,RADWIN-MIB-WINLINK1000::lanPort2DisconnectedAlarm,,,,,, Indicates the LAN port 2 status changed to disconnected. Contains a single parameter, which is its description: 1 - Description: LAN port 2 status changed to disconnected. +.1.3.6.1.4.1.4458.1000.0.111,RADWIN-MIB-WINLINK1000::mngPortDisconnectedAlarm,,,,,, Indicates the LAN1 port status changed to disconnected. Contains a single parameter, which is its description: 1 - Description: LAN1 port status changed to disconnected. +.1.3.6.1.4.1.4458.1000.0.112,RADWIN-MIB-WINLINK1000::externalAlarmInPort3Alarm,,,,,, The trap is sent every time an alarm occurs in the External Alarm Input of port #3. Contains a single parameter, which is its description: 1 - Description: External Alarm 3 - - Alarm. +.1.3.6.1.4.1.4458.1000.0.113,RADWIN-MIB-WINLINK1000::externalAlarmInPort4Alarm,,,,,, The trap is sent every time an alarm occurs in the External Alarm Input of port #4. Contains a single parameter, which is its description: 1 - Description: External Alarm 4 - - Alarm. +.1.3.6.1.4.1.4458.1000.0.114,RADWIN-MIB-WINLINK1000::swVersionsMismatchFullCompatibilityAlarm,,,,,, The trap is sent if SW versions mismatch with full link functionality. Contains a single parameter, which is its description: 1 - Description: Software versions mismatch - full link functionality +.1.3.6.1.4.1.4458.1000.0.115,RADWIN-MIB-WINLINK1000::swVersionsMismatchRestrictedCompatibilityAlarm,,,,,, The trap is sent if SW versions mismatch with restricted link functionality. Contains a single parameter, which is its description: 1 - Description: Software versions mismatch - restricted link functionality +.1.3.6.1.4.1.4458.1000.0.116,RADWIN-MIB-WINLINK1000::swVersionsMismatchSoftwareUpgradeRequired,,,,,, The trap is sent if SW versions mismatch and SW upgrade is required. Contains a single parameter, which is its description: 1 - Description: Software versions mismatch - Software upgrade required +.1.3.6.1.4.1.4458.1000.0.117,RADWIN-MIB-WINLINK1000::swVersionsIncompatible,,,,,, The trap is sent if SW versions are incompatible. Contains a single parameter, which is its description: 1 - Description: SW Versions incompatible +.1.3.6.1.4.1.4458.1000.0.118,RADWIN-MIB-WINLINK1000::hssMultipleSourcesDetectedAlarm,,,,,, Indicates that multiple sync pulse sources were detected. Contains a single parameter, which is its description: 1 - Description: HSS multiple sync sources were detected. +.1.3.6.1.4.1.4458.1000.0.119,RADWIN-MIB-WINLINK1000::hssSyncToProperSourceStoppedAlarm,,,,,, Indicates that synchronization to a proper sync pulse source was stopped. Contains a single parameter, which is its description: 1 - Description: HSS sync pulse - Down. The reason is: %s. %s - Is the reason for the sync down. +.1.3.6.1.4.1.4458.1000.0.120,RADWIN-MIB-WINLINK1000::hssSyncPulseDetectedAlarm,,,,,, Indicates that HSS additional sync pulse was detected. Contains a single parameter, which is its description: 1 - Description: HSS additional sync pulse was detected. +.1.3.6.1.4.1.4458.1000.0.121,RADWIN-MIB-WINLINK1000::tdmBackupAlarm,,,,,, Indicates that the TDM backup link was activated. Contains a single parameter, which is its description: 1 - Description: TDM backup alarm - backup link was activated. +.1.3.6.1.4.1.4458.1000.0.122,RADWIN-MIB-WINLINK1000::linkLockUnauthorizedRemoteODU,,,,,, Indicates that the remote ODU is unauthorized. Contains a single parameter, which is its description: 1 - Description: Unauthorized remote ODU connection rejected. +.1.3.6.1.4.1.4458.1000.0.123,RADWIN-MIB-WINLINK1000::linkLockUnauthorizedODU,,,,,, Indicates that the ODU is unauthorized. Contains a single parameter, which is its description: 1 - Description: Unauthorized ODU connection rejected. +.1.3.6.1.4.1.4458.1000.0.124,RADWIN-MIB-WINLINK1000::hotStandbyAlarm,,,,,, Indicates that the hot standby secondary link was activated. Contains a single parameter, which is its description: 1 - Description: Secondary Link Is Active. +.1.3.6.1.4.1.4458.1000.0.126,RADWIN-MIB-WINLINK1000::sfpInsertion,,,,,, Indicates that a device was inserted to SFP Port +.1.3.6.1.4.1.4458.1000.0.127,RADWIN-MIB-WINLINK1000::sfpPort1DisconnectedAlarm,,,,,, Indicates the SFP port 1 status changed to disconnected. Contains a single parameter which is its description: 1 - Description: SFP port 1 status changed to disconnected. +.1.3.6.1.4.1.4458.1000.0.128,RADWIN-MIB-WINLINK1000::ringRplStateActiveAlarm,,,,,, RPL state changed to Active. +.1.3.6.1.4.1.4458.1000.0.129,RADWIN-MIB-WINLINK1000::desiredRatioCanNotBeAppliedAlarm,,,,,, Indicates Desired UL/DL RAtio Can Not Be Applied. +.1.3.6.1.4.1.4458.1000.0.130,RADWIN-MIB-WINLINK1000::cbwMismatch,,,,,, Indicates that a Channel Bandwidth mismatch was detected. Contains two parameters: 1 - Description: Channel Bandwidth Mismatch: one side is %n0 MHz and the other is %n1 MHz. %n0 is the local Channel Bandwidth value in MHz. %n1 is the remote Channel Bandwidth value in MHz. +.1.3.6.1.4.1.4458.1000.0.131,RADWIN-MIB-WINLINK1000::gpsNotSynchronized,,,,,, Indicates that the GPS is not synchronized with satellites. Pulses are self generated. +.1.3.6.1.4.1.4458.1000.0.132,RADWIN-MIB-WINLINK1000::pdTooHighDueCbwLimitations,,,,,, Indicates that link cannot be established because link range is too large for channel bandwidth. +.1.3.6.1.4.1.4458.1000.0.133,RADWIN-MIB-WINLINK1000::hbsEncryptionAlarm,,,,,, Indicates an encryption key mismatch. Contains a single parameter, which is its description, including the HSU's name +.1.3.6.1.4.1.4458.1000.0.134,RADWIN-MIB-WINLINK1000::hbsEhServiceClosedToHsu,,,,,, Indicates an encryption key mismatch. Contains a single parameter, which is its description, including the HSU's name +.1.3.6.1.4.1.4458.1000.0.135,RADWIN-MIB-WINLINK1000::hbsUnsynchronizedHsuAlarm,,,,,, Indicates a registered HSU lost synchronization. +.1.3.6.1.4.1.4458.1000.0.136,RADWIN-MIB-WINLINK1000::hbsInactiveHbsAlarm,,,,,, Indicates HBS is InActive. +.1.3.6.1.4.1.4458.1000.0.137,RADWIN-MIB-WINLINK1000::incompatibleHsu,,,,,, Indicates that the HSU is not compatible to HBS. Contains a single parameter, which is its description: 1 - Description: Incompatible HSU. +.1.3.6.1.4.1.4458.1000.0.138,RADWIN-MIB-WINLINK1000::hsuUnsupportedBeacon,,,,,, Indicates an unsupported beacon has arrived at HSU +.1.3.6.1.4.1.4458.1000.0.139,RADWIN-MIB-WINLINK1000::lanPortDisconnectedAlarm,,,,,, Indicates the LAN port status changed to disconnected. Contains a single parameter, which is its description: 1 - Description: LAN port status changed to disconnected. +.1.3.6.1.4.1.4458.1000.0.140,RADWIN-MIB-WINLINK1000::poePortDisconnectedAlarm,,,,,, Indicates the LAN2 port status changed to disconnected. Contains a single parameter, which is its description: 1 - Description: LAN2 port status changed to disconnected. +.1.3.6.1.4.1.4458.1000.0.141,RADWIN-MIB-WINLINK1000::poePowerConsumptionAlarm,,,,,, Indicates the POE Power Consumption is above allowed maximum. Contains a single parameter, which is its description: 1 - Description: POE consumption above allowed maximum. port closed. +.1.3.6.1.4.1.4458.1000.0.149,RADWIN-MIB-WINLINK1000::hobupFaultyStateAlarm,,,,,, This Alarm will indicate that the Hot Backup module is in faulty state. 1 - Description: Hot Backup fault detected: %s unit. %s - Primary Or Secondary Unit +.1.3.6.1.4.1.4458.1000.0.150,RADWIN-MIB-WINLINK1000::gpsOverCurrentAlarm,,,,,, Indicates the GPS Antenna current consumption is above allowed maximum. Contains a single parameter, which is its description: 1 - Description: GPS Antenna current consumption above allowed maximum. GPS closed. +.1.3.6.1.4.1.4458.1000.0.151,RADWIN-MIB-WINLINK1000::gpsCommunicationFailiureAlarm,,,,,, Indicates the GPS data isn't received. Contains a single parameter, which is its description: 1 - Description: GPS Communication failiure. +.1.3.6.1.4.1.4458.1000.0.152,RADWIN-MIB-WINLINK1000::temperatureThresholdAlarm,,,,,, Indicates the board temperature is above allowed maximum. Contains a single parameter, which is its description: 1 - Description: Indicates the board temperature exceed the threshold. +.1.3.6.1.4.1.4458.1000.0.153,RADWIN-MIB-WINLINK1000::localRouterDiscoveryStatus,,,,,, This Alarm will indicate that we have no connection with local train router. 1 - Description: MacLearningUpdate detected disconnection with local train router %s %s - local train IP +.1.3.6.1.4.1.4458.1000.0.154,RADWIN-MIB-WINLINK1000::trackRouterDiscoveryStatus,,,,,, This Alarm will indicate that we have no connection with Track side router. 1 - Description: MacLearningUpdate detected disconnection with Track side router %s %s - Default gateway IP +.1.3.6.1.4.1.4458.1000.0.155,RADWIN-MIB-WINLINK1000::lastUserSnmpAccessOverHourAgo,,,,,, This trap will indicate that the last access of the accessing user was more than an hour ago. 1 - Description: User %s performed SNMP access after more than an hour. %s - user name +.1.3.6.1.4.1.4458.1000.0.156,RADWIN-MIB-WINLINK1000::btsTargetUnreachable,,,,,, This Alarm will indicate that we have no connection with Bts desired target. 1 - Description: TNC detected disconnection with the BTS target %s %s - Default gateway IP +.1.3.6.1.4.1.4458.1000.0.158,RADWIN-MIB-WINLINK1000::hbsLinkQualityDegredationDlAlarm,,,,,, Indicates a link downlink quality degredation. +.1.3.6.1.4.1.4458.1000.0.159,RADWIN-MIB-WINLINK1000::hbsLinkQualityDegredationUlAlarm,,,,,, Indicates a link uplink quality degredation. +.1.3.6.1.4.1.4458.1000.0.200,RADWIN-MIB-WINLINK1000::tdmServiceClear,,,,,, Indicates that TDM Service fault is cleared. Contains a single parameter, which is its description: 1 - Description: TDM Service - Normal. +.1.3.6.1.4.1.4458.1000.0.201,RADWIN-MIB-WINLINK1000::ethServiceOpened,,,,,, Indicates that Ethernet Service has been opened. Contains a single parameter, which is its description: 1 - Description: Ethernet Service has been opened. +.1.3.6.1.4.1.4458.1000.0.203,RADWIN-MIB-WINLINK1000::encryptionClear,,,,,, Indicates that encryption is OK. Contains a single parameter, which is its description: 1 - Description: Encryption Status - Normal. +.1.3.6.1.4.1.4458.1000.0.204,RADWIN-MIB-WINLINK1000::changeLinkPasswordClear,,,,,, Indicates that the Link Password was changed successfully. Contains a single parameter, which is its description: 1 - Description: Link Password has been changed at/on: %s. %s - Is the Local Site name or Remote Site name or both sides of the Link. +.1.3.6.1.4.1.4458.1000.0.205,RADWIN-MIB-WINLINK1000::externalAlarmInPort1Clear,,,,,, This Trap is sent every time an External Alarm Input fault of port # 1 is cleared. Contains a single parameter, which is its description: 1 - Description: External Alarm 1 - - Alarm Cleared. +.1.3.6.1.4.1.4458.1000.0.206,RADWIN-MIB-WINLINK1000::externalAlarmInPort2Clear,,,,,, This Trap is sent every time an External Alarm Input fault of port # 2 is cleared. Contains a single parameter, which is its description: 1 - Description: External Alarm 2 - - Alarm Cleared. +.1.3.6.1.4.1.4458.1000.0.209,RADWIN-MIB-WINLINK1000::lanPort1Clear,,,,,, Indicates the LAN port 1 status changed to connected. Contains two parameters: 1 - Description: LAN port 1 status changed to connected - %s 2 - %s Is the Eth. mode (speed & duplex) +.1.3.6.1.4.1.4458.1000.0.210,RADWIN-MIB-WINLINK1000::lanPort2Clear,,,,,, Indicates the LAN port 2 status changed to connected. Contains two parameters: 1 - Description: LAN port 2 status changed to connected - %s. 2 - %s Is the Eth. mode (speed & duplex). +.1.3.6.1.4.1.4458.1000.0.211,RADWIN-MIB-WINLINK1000::mngPortClear,,,,,, Indicates the LAN1 port status changed to connected. Contains two parameters: 1 - Description: LAN1 port status changed to connected - %s 2 - %s Is the Eth. mode (speed & duplex) +.1.3.6.1.4.1.4458.1000.0.212,RADWIN-MIB-WINLINK1000::externalAlarmInPort3Clear,,,,,, This Trap is sent every time an External Alarm Input fault of port # 3 is cleared. Contains a single parameter, which is its description: 1 - Description: External Alarm 3 - - Alarm Cleared. +.1.3.6.1.4.1.4458.1000.0.213,RADWIN-MIB-WINLINK1000::externalAlarmInPort4Clear,,,,,, This Trap is sent every time an External Alarm Input fault of port # 4 is cleared. Contains a single parameter, which is its description: 1 - Description: External Alarm 4 - - Alarm Cleared. +.1.3.6.1.4.1.4458.1000.0.214,RADWIN-MIB-WINLINK1000::swVersionsMatchFullCompatibilityClear,,,,,, The trap is sent if SW versions match. Contains a single parameter, which is its description: 1 - Description: Software Versions compatible +.1.3.6.1.4.1.4458.1000.0.215,RADWIN-MIB-WINLINK1000::swVersionsMatchRestrictedCompatibilityClear,,,,,, The trap is sent if SW versions match and link functionality is not restricted. Contains a single parameter, which is its description: 1 - Description: Software Versions compatible +.1.3.6.1.4.1.4458.1000.0.216,RADWIN-MIB-WINLINK1000::swVersionsMatchSoftwareUpgradeRequiredClear,,,,,, The trap is sent if SW versions match and SW upgrade is successful. Contains a single parameter, which is its description: 1 - Description: Software Versions compatible +.1.3.6.1.4.1.4458.1000.0.217,RADWIN-MIB-WINLINK1000::swVersionsCompatibleClear,,,,,, The trap is sent if SW versions compatible Contains a single parameter, which is its description: 1 - Description: Software Versions compatible +.1.3.6.1.4.1.4458.1000.0.218,RADWIN-MIB-WINLINK1000::hssMultipleSourcesDisappearedClear,,,,,, Indicates that multiple sync pulse sources disappeared. Contains a single parameter, which is its description: 1 - Description: HSS multiple sync pulse sources disappeared. +.1.3.6.1.4.1.4458.1000.0.219,RADWIN-MIB-WINLINK1000::hssSyncToProperSourceAchievedClear,,,,,, Indicates that synchronization to a proper Sync source was achieved. Contains a single parameter, which is its description: 1 - Description: HSS sync pulse - Up. +.1.3.6.1.4.1.4458.1000.0.220,RADWIN-MIB-WINLINK1000::hssSyncPulseDisappearedClear,,,,,, Indicates that HSS additional sync pulse disappeared. Contains a single parameter, which is its description: 1 - Description: HSS additional sync pulse was disappeared. +.1.3.6.1.4.1.4458.1000.0.221,RADWIN-MIB-WINLINK1000::tdmBackupClear,,,,,, Indicates that the TDM main link was activated. Contains a single parameter, which is its description: 1 - Description: TDM main link was activated. +.1.3.6.1.4.1.4458.1000.0.222,RADWIN-MIB-WINLINK1000::linkLockAuthorizedRemoteODU,,,,,, Indicates that the remote ODU is authorized. Contains a single parameter, which is its description: 1 - Description: Authorized remote ODU connection accepted. +.1.3.6.1.4.1.4458.1000.0.223,RADWIN-MIB-WINLINK1000::linkLockAuthorizedODU,,,,,, Indicates that the ODU is authorized. Contains a single parameter, which is its description: 1 - Description: Authorized ODU connection permitted. +.1.3.6.1.4.1.4458.1000.0.224,RADWIN-MIB-WINLINK1000::linkAuthenticationDisabled,,,,,, Indicates that the Link Lock is disabled. Contains a single parameter, which is its description: 1 - Description: Link Authentication has been disabled. +.1.3.6.1.4.1.4458.1000.0.225,RADWIN-MIB-WINLINK1000::hotStandbyClear,,,,,, Indicates that the Primary Link Was Activated. Contains a single parameter, which is its description: 1 - Description: Primary Link Is Active. +.1.3.6.1.4.1.4458.1000.0.226,RADWIN-MIB-WINLINK1000::sfpExtraction,,,,,, Indicates that a device was extracted from SFP Port +.1.3.6.1.4.1.4458.1000.0.227,RADWIN-MIB-WINLINK1000::sfpPort1Clear,,,,,, Indicates the SFP port 1 status changed to connected. Contains two parameters: 1 - Description: SFP port 1 status changed to connected - %s 2 - %s Is the Eth. mode (speed & duplex) +.1.3.6.1.4.1.4458.1000.0.228,RADWIN-MIB-WINLINK1000::compatibleIdus,,,,,, Indicates that the ODU has identified compatible Idus on both sides of the link. +.1.3.6.1.4.1.4458.1000.0.229,RADWIN-MIB-WINLINK1000::desiredRatioCanNotBeAppliedClear,,,,,, Indicates Current UL/DL Ratio Is Equal To Desired Ratio. +.1.3.6.1.4.1.4458.1000.0.230,RADWIN-MIB-WINLINK1000::cbwMatch,,,,,, Indicates that a Channel Bandwidth match was detected. Contains a single parameter, which is its description: 1 - Channel Bandwidth value in MHz. +.1.3.6.1.4.1.4458.1000.0.231,RADWIN-MIB-WINLINK1000::switchCbwAndChannel,,,,,, Indicates that the system is switching Channel Bandwidth and channel frequency. Contains two parameters: 1 - Switching to Channel Bandwidth %n0 MHz. 2 - Switching to Channel Frequency %n1 GHz. +.1.3.6.1.4.1.4458.1000.0.232,RADWIN-MIB-WINLINK1000::ringRplStateIdle,,,,,, RPL state changed to Idle. +.1.3.6.1.4.1.4458.1000.0.233,RADWIN-MIB-WINLINK1000::ringEthServiceStatus,,,,,, Indicates Ethernet service's state - blocked \ unblocked. Contains a single parameter: 1 - Description: Ethernet's state (blocked \ unblocked) +.1.3.6.1.4.1.4458.1000.0.234,RADWIN-MIB-WINLINK1000::ringFirstRpmReceived,,,,,, Ring application: in non-RPL link indicates first from a specific RPL was received. Contains a single parameter: 1 - Description: RPM's VLAN ID +.1.3.6.1.4.1.4458.1000.0.235,RADWIN-MIB-WINLINK1000::ringEthernetSrviceUnblockedTO,,,,,, Ring application: in non-RPL link Ethernet service is unblocked due to RPM timeout. +.1.3.6.1.4.1.4458.1000.0.236,RADWIN-MIB-WINLINK1000::gpsSynchronized,,,,,, Indicates that the GPS is synchronized with satellites. +.1.3.6.1.4.1.4458.1000.0.237,RADWIN-MIB-WINLINK1000::hbsEncryptionClear,,,,,, Indicates that encryption is OK. Contains a single parameter, which is its description, including the HSU's name +.1.3.6.1.4.1.4458.1000.0.238,RADWIN-MIB-WINLINK1000::hbsEhServiceOpenedToHsu,,,,,, Indicates that encryption is OK. Contains a single parameter, which is its description, including the HSU's name +.1.3.6.1.4.1.4458.1000.0.239,RADWIN-MIB-WINLINK1000::hbsSynchronizedHsuAlarm,,,,,, Indicates a registered HSU is synchronized. +.1.3.6.1.4.1.4458.1000.0.240,RADWIN-MIB-WINLINK1000::hbsActiveHbs,,,,,, Indicates when HBS has been activated. +.1.3.6.1.4.1.4458.1000.0.241,RADWIN-MIB-WINLINK1000::switchCBW,,,,,, Switching Channel Bandwidth. +.1.3.6.1.4.1.4458.1000.0.242,RADWIN-MIB-WINLINK1000::changeRatio,,,,,, HBS Tx ratio has changed. +.1.3.6.1.4.1.4458.1000.0.243,RADWIN-MIB-WINLINK1000::lanPortClear,,,,,, Indicates the LAN port status changed to connected. Contains two parameters: 1 - Description: LAN port status changed to connected - %s 2 - %s Is the Eth. mode (speed & duplex) +.1.3.6.1.4.1.4458.1000.0.244,RADWIN-MIB-WINLINK1000::poePortClear,,,,,, Indicates the LAN2 port status changed to connected. Contains two parameters: 1 - Description: LAN2 port status changed to connected - %s 2 - %s Is the Eth. mode (speed & duplex) +.1.3.6.1.4.1.4458.1000.0.245,RADWIN-MIB-WINLINK1000::poePowerConsumptionClear,,,,,, Indicates the POE power consumption is valid. Contains two parameters: 1 - Description: POE consumption within limits. port is opened. 2 - %s Is the Eth. mode (speed & duplex) +.1.3.6.1.4.1.4458.1000.0.246,RADWIN-MIB-WINLINK1000::incompatibleHbsHsu,,,,,, Incompatible HBS/HSU software versions - no service. +.1.3.6.1.4.1.4458.1000.0.247,RADWIN-MIB-WINLINK1000::mobilityLinkOff,,,,,, Mobility - Link cannot be established due to: 1 - The HBS does not support Mobility 2 - Lack of resources in the HBS for HSU level +.1.3.6.1.4.1.4458.1000.0.248,RADWIN-MIB-WINLINK1000::enterLocalConnection,,,,,, Entering Local Connection (Broadcast) Mode. +.1.3.6.1.4.1.4458.1000.0.249,RADWIN-MIB-WINLINK1000::hobupActiveStateFaultyClear,,,,,, this clear alarm will indicate that the Hot Backup unit is in active state. Contains a single parameter, which is its description: 1 - Description: Hot Backup %s unit activated. %s - Primary Or Secondary Unit +.1.3.6.1.4.1.4458.1000.0.250,RADWIN-MIB-WINLINK1000::hobupStandbyState,,,,,, This info fault will indicate that the Hot backup module has entered standby/peer_detection state Contains a single parameter, which is its description: 1 - Description: Hot Backup in Standby state: %s unit. %s - Primary Or Secondary Unit +.1.3.6.1.4.1.4458.1000.0.251,RADWIN-MIB-WINLINK1000::gpsOverCurrentClear,,,,,, Indicates the GPS Antenna current consumption is valid. +.1.3.6.1.4.1.4458.1000.0.252,RADWIN-MIB-WINLINK1000::temperatureThresholdClear,,,,,, Indicates the board temperature is valid. +.1.3.6.1.4.1.4458.1000.0.253,RADWIN-MIB-WINLINK1000::localRouterDiscoverySucceed,,,,,, Indicates that we succeeded to discover train router in ip %s MAC address %s %s Train IP %s Train MAC Address +.1.3.6.1.4.1.4458.1000.0.254,RADWIN-MIB-WINLINK1000::trackRouterDiscoverySucceed,,,,,, Indicates that we succeeded to discover track router in ip %s MAC address %s %s Train IP %s Train MAC Address +.1.3.6.1.4.1.4458.1000.0.255,RADWIN-MIB-WINLINK1000::qosVersion2StrictMismatch,,,,,, CPE doesn't support strict QOS configuration. +.1.3.6.1.4.1.4458.1000.0.256,RADWIN-MIB-WINLINK1000::qosVersion2TtlMismatch,,,,,, CPE doesn't support TTL configuration. +.1.3.6.1.4.1.4458.1000.0.257,RADWIN-MIB-WINLINK1000::btsTargetIsReachable,,,,,, Indicated the we succeeded to establish connection with the Bts desired target (%s) %s Target IP +.1.3.6.1.4.1.4458.1000.0.258,RADWIN-MIB-WINLINK1000::tcNotSupportedByHSU,,,,,, CPE doesn't support TC functionality. +.1.3.6.1.4.1.4458.1000.0.259,RADWIN-MIB-WINLINK1000::syncEPortHOStateChange,,,,,, Enter/leave HO state of SyncE port. +.1.3.6.1.4.1.4458.1000.0.260,RADWIN-MIB-WINLINK1000::syncEPortFailureStateChange,,,,,, Enter/leave Failure state of SyncE port. +.1.3.6.1.4.1.4458.1000.0.261,RADWIN-MIB-WINLINK1000::btsCpeUpdateServiceFailed,,,,,, Update service Failed +.1.3.6.1.4.1.4458.1000.0.262,RADWIN-MIB-WINLINK1000::btsCpeUpdateServiceSucceed,,,,,, Update service Succeed +.1.3.6.1.4.1.4458.1000.0.263,RADWIN-MIB-WINLINK1000::radiusServerNoREsponse,,,,,, No response from radius server +.1.3.6.1.4.1.4458.1000.0.264,RADWIN-MIB-WINLINK1000::noRadiusServerRespond,,,,,, No response from radius server +.1.3.6.1.4.1.4458.1000.0.265,RADWIN-MIB-WINLINK1000::radiusServerRespondedSuccessfully,,,,,, indicates that Radius server responded successfully. +.1.3.6.1.4.1.4458.1000.0.266,RADWIN-MIB-WINLINK1000::bsaAlignmentStarted,,,,,, Indicate the beginning of Alignment Process +.1.3.6.1.4.1.4458.1000.0.267,RADWIN-MIB-WINLINK1000::bsaAlignmentFinished,,,,,, Indicate the completion of Alignment Process +.1.3.6.1.4.1.4458.1000.0.268,RADWIN-MIB-WINLINK1000::bsaAlignmentTriggered,,,,,, Indicate the triggering of Alignment Process due to exceeding thresholds +.1.3.6.1.4.1.4458.1000.0.269,RADWIN-MIB-WINLINK1000::hbsLinkQualityImprovedDlClear,,,,,, Indicates that downlink link quality improved. Contains a single parameter, which is its description, including the HSU's name +.1.3.6.1.4.1.4458.1000.0.270,RADWIN-MIB-WINLINK1000::hbsLinkQualityImprovedUlClear,,,,,, Indicates that uplink link quality improved. Contains a single parameter, which is its description, including the HSU's name +.1.3.6.1.4.1.4458.1000.0.271,RADWIN-MIB-WINLINK1000::hsuResourceTypeMismatch,,,,,, Indicate mismatch between HSU type and resource allocation +.1.3.6.1.4.1.4458.1000.0.272,RADWIN-MIB-WINLINK1000::externalAntennaAttached,,,,,, Indicates that the External Antenna is attached +.1.3.6.1.4.1.4458.1000.0.273,RADWIN-MIB-WINLINK1000::externalAntennaDetached,,,,,, Indicates that the External Antenna is detached +.1.3.6.1.4.1.4458.1000.0.274,RADWIN-MIB-WINLINK1000::wifiEnabled,,,,,, Indicates that the Wifi is enabled +.1.3.6.1.4.1.4458.1000.0.275,RADWIN-MIB-WINLINK1000::wifiDisabled,,,,,, Indicates that the wifi is disabled +.1.3.6.1.4.1.4458.1000.0.276,RADWIN-MIB-WINLINK1000::wifiUserConnected,,,,,, Indicates that the Wifi is connected by some user +.1.3.6.1.4.1.4458.1000.0.277,RADWIN-MIB-WINLINK1000::authenticationMgrUserAutheticationDoneLocally,,,,,, Authentication Mgr User Authentication is done locally and not against radius server. +.1.3.6.1.4.1.4458.1000.0.278,RADWIN-MIB-WINLINK1000::authenticationMgrRadiusrequestResult,,,,,, Authentication Mgr : Request result returned from Radius Authentication Server . +.1.3.6.1.4.1.4458.1000.0.279,RADWIN-MIB-WINLINK1000::authenticationMgrRemovedEntryFromTable,,,,,, Authentication Mgr : Removed User Or Ip from table. +.1.3.6.1.4.1.4458.1000.0.280,RADWIN-MIB-WINLINK1000::hsuAuthenticationErrorState,,,,,, Indicates (on the HSU side) that the HSU is in authentication error state +.1.3.6.1.4.1.4458.1000.0.281,RADWIN-MIB-WINLINK1000::hbsHsuAuthenticationErrorState,,,,,, Indicates (on the HSU side) that the HSU is in authentication error state +.1.3.6.1.4.1.4458.1000.0.282,RADWIN-MIB-WINLINK1000::hsuExitingViolatedState,,,,,, Indicates (on the HSU side) that the HSU exited from violated state +.1.3.6.1.4.1.4458.1000.0.283,RADWIN-MIB-WINLINK1000::batteryCapacityBelowThreshold,,,,,, Indicates that battery capacity is below the threshold. +.1.3.6.1.4.1.4458.1000.0.284,RADWIN-MIB-WINLINK1000::batteryTemperatureOutOfRange,,,,,, Indicates that battery temperature is out of range. +.1.3.6.1.4.1.4458.1000.0.285,RADWIN-MIB-WINLINK1000::batteryVoltageOutOfRange,,,,,, Indicates that battery voltage is out of range. +.1.3.6.1.4.1.4458.1000.0.286,RADWIN-MIB-WINLINK1000::batteryCurrentOutOfRange,,,,,, Indicates that battery current is out of range. +.1.3.6.1.4.1.4458.1000.0.287,RADWIN-MIB-WINLINK1000::portPowerFailure,,,,,, Indicates port power failure. +.1.3.6.1.4.1.4458.1000.0.288,RADWIN-MIB-WINLINK1000::portPowerOn,,,,,, Indicates port power is on. +.1.3.6.1.4.1.4458.1000.0.289,RADWIN-MIB-WINLINK1000::portPowerOff,,,,,, Indicates port power is off. +.1.3.6.1.4.1.4458.1000.0.290,RADWIN-MIB-WINLINK1000::portPingLossToDevice,,,,,, Indicates port keepalive lost ping to configured device ip. +.1.3.6.1.4.1.4458.1000.0.291,RADWIN-MIB-WINLINK1000::ambientTemperatureNormal,,,,,, Indicates that the ambient temprature is normal. +.1.3.6.1.4.1.4458.1000.0.292,RADWIN-MIB-WINLINK1000::ambientTemperatureOutOfRange,,,,,, Indicates that the ambient temprature is out of range. +.1.3.6.1.4.1.4458.1000.0.293,RADWIN-MIB-WINLINK1000::mainPowerSupplyFailure,,,,,, Indicates of main power supply failure +.1.3.6.1.4.1.4458.1000.0.294,RADWIN-MIB-WINLINK1000::mainPowerSupplyResume,,,,,, Indicates that main power supply resume. +.1.3.6.1.4.1.4458.1000.0.295,RADWIN-MIB-WINLINK1000::inputAlarm1Off,,,,,, Indicates Input Alarm #1 changed to off. +.1.3.6.1.4.1.4458.1000.0.296,RADWIN-MIB-WINLINK1000::inputAlarm1On,,,,,, Indicates Input Alarm #1 changed to on. +.1.3.6.1.4.1.4458.1000.0.297,RADWIN-MIB-WINLINK1000::inputAlarm2Off,,,,,, Indicates Input Alarm #2 changed to off. +.1.3.6.1.4.1.4458.1000.0.298,RADWIN-MIB-WINLINK1000::inputAlarm2On,,,,,, Indicates Input Alarm #2 changed to on. +.1.3.6.1.4.1.4458.1000.0.299,RADWIN-MIB-WINLINK1000::tamperCoverClosed,,,,,, Indicates that the smartnode cover was closed. +.1.3.6.1.4.1.4458.1000.0.300,RADWIN-MIB-WINLINK1000::tamperCoverOpened,,,,,, Indicates that the smartnode cover was opened. +.1.3.6.1.4.1.4458.1000.0.301,RADWIN-MIB-WINLINK1000::port8021xEnabledChangedState,,,,,, Indicates that 802.1x Enabled Port has changed its state for supplicant +.1.3.6.1.4.1.4458.1000.0.302,RADWIN-MIB-WINLINK1000::ethMissionServerEthernetPortRestarted,,,,,, EthMissionServer : Ethernet port was restarted +.1.3.6.1.4.1.4458.1000.0.303,RADWIN-MIB-WINLINK1000::virtualIPMismatch,,,,,, Signal that the peer Mus have different Virtual IP +.1.3.6.1.4.1.4458.1000.0.304,RADWIN-MIB-WINLINK1000::sshAuthenticationFailure,,,,,, Signal that SSH Authentication failure +.1.3.6.1.4.1.4458.1000.0.305,RADWIN-MIB-WINLINK1000::sshAuthenticationSuccess,,,,,, Signal that SSH Authentication success +.1.3.6.1.4.1.4458.1000.0.306,RADWIN-MIB-WINLINK1000::hssSwHscPartiallySupported,,,,,, incompatible HSS Configuration - please upgrade HSM +.1.3.6.1.4.1.4458.1000.0.307,RADWIN-MIB-WINLINK1000::hssFwUpgradeFailure,,,,,, Failed to update GPS firmware - please reboot device +.1.3.6.1.4.1.4458.1000.0.311,RADWIN-MIB-WINLINK1000::tvwsdbConnectivityErrorAlarm,,,,,, A trap indicating a connectivity error with the TVWSDB. 1 - Description: connectivity error with the TVWSDB +.1.3.6.1.4.1.4458.1000.0.312,RADWIN-MIB-WINLINK1000::tvwsUriChangedByTvws,,,,,, A trap indicating TVWSDB URI change, indicated in a response during INIT message. 1 - Description: TVWSDB URI change +.1.3.6.1.4.1.4458.1000.0.313,RADWIN-MIB-WINLINK1000::tvwsPawsErrorAlarm,,,,,, A trap indicating an error in PAWS message 1 - Description: error in PAWS message +.1.3.6.1.4.1.4458.1000.0.314,RADWIN-MIB-WINLINK1000::tvwsdbConnectedClear,,,,,, A trap indicating successful connectivity with the TVWSDB. 1 - Description: successful connectivity with the TVWSDB. +.1.3.6.1.4.1.4458.1000.0.315,RADWIN-MIB-WINLINK1000::tvwsdbEtsiWeblistingConnectivityError,,,,,, A trap indicating a connectivity error with ETSI TVWSDB weblisting. 1 - Description: connectivity error with ETSI TVWSDB weblisting. +.1.3.6.1.4.1.4458.1000.0.316,RADWIN-MIB-WINLINK1000::tvwsMopClear,,,,,, A trap indicating the selected Master operational parameters following channel selection algorithm. 1 - Description: selected Master operational parameters following channel selection algorithm. +.1.3.6.1.4.1.4458.1000.0.317,RADWIN-MIB-WINLINK1000::tvwsNoAvailableChannelForHbsAlarm,,,,,, A trap indicating that the channel selection algorithm found no available channel for the HBS 1 - Description: channel selection algorithm found no available channel for the HBS +.1.3.6.1.4.1.4458.1000.0.318,RADWIN-MIB-WINLINK1000::tvwsGop,,,,,, A trap indicating the Generic Slave operational parameters following channel selection algorithm 1 - Description: Generic Slave operational parameters following channel selection algorithm +.1.3.6.1.4.1.4458.1000.0.319,RADWIN-MIB-WINLINK1000::tvwsSopClear,,,,,, A trap indicating the selected Slave operational parameters following carrier selection algorithm for HSU 1 - Description: selected Slave operational parameters following carrier selection algorithm for HSU +.1.3.6.1.4.1.4458.1000.0.320,RADWIN-MIB-WINLINK1000::tvwsSpectrumUseRespError,,,,,, A trap indicating error in SPECTRUM_USE_RESP message 1 - Description: error in SPECTRUM_USE_RESP message +.1.3.6.1.4.1.4458.1000.0.321,RADWIN-MIB-WINLINK1000::tvwsSpectrumUseRespCriticalErrorAlarm,,,,,, A trap indicating error in SPECTRUM_USE_RESP message 1 - Description: error in SPECTRUM_USE_RESP message +.1.3.6.1.4.1.4458.1000.0.322,RADWIN-MIB-WINLINK1000::tvwsNoCarrierAvailableForRegisteredHsuAlarm,,,,,, A trap indicating that the carrier selection algorithm found no available channel for a registered HSU. 1 - Description: carrier selection algorithm found no available channel for a registered HSU. +.1.3.6.1.4.1.4458.1000.0.323,RADWIN-MIB-WINLINK1000::tvwsNoCarrierAvailableForUnregisteredHsu,,,,,, A trap indicating that the carrier selection algorithm found no available channel for an unregistered HSU. 1 - Description: carrier selection algorithm found no available channel for an unregistered HSU. +.1.3.6.1.4.1.4458.1000.0.324,RADWIN-MIB-WINLINK1000::gpsNotSynchronizedAlarm,,,,,, A trap indicating that the GPS is not synchronized 1 - Description: GPS is not synchronized +.1.3.6.1.4.1.4458.1000.0.325,RADWIN-MIB-WINLINK1000::gpsSynchronizedClear,,,,,, A trap indicating that the GPS is synchronized 1 - Description: GPS is synchronized +.1.3.6.1.4.1.4458.1000.0.326,RADWIN-MIB-WINLINK1000::gpsLocationChange,,,,,, A trap indicating that the GPS coordinates changed by a distance > max location change defined by the TVWSDB 1 - Description: GPS coordinates changed by a distance > max location change defined by the TVWSDB +.1.3.6.1.4.1.4458.1000.0.327,RADWIN-MIB-WINLINK1000::tvwsHardwareFailure,,,,,, A trap indicating that the TVWS hardware encountered critical failure +.1.3.6.1.4.1.4458.1000.0.328,RADWIN-MIB-WINLINK1000::changeStateOdu,,,,,, Indicated on state change of the unit due to redundancy feature. +.1.3.6.1.4.1.4458.1000.0.329,RADWIN-MIB-WINLINK1000::radiusAuthenErrClear,,,,,, Radius Authentication Error clear +.1.3.6.1.4.1.4458.1000.0.330,RADWIN-MIB-WINLINK1000::radiusCommunicationErr,,,,,, Radius Communication Error - Server Authentication Failed +.1.3.6.1.4.1.4458.1000.0.331,RADWIN-MIB-WINLINK1000::duplicateMacDetected,,,,,, Indicates that duplicated MAC is detected and corresponding SU is blocked. +.1.3.6.1.4.1.4458.1000.0.332,RADWIN-MIB-WINLINK1000::radiusAuthorizationFailure,,,,,, Authorization reject from Radius Server. +.1.3.6.1.4.1.4458.1000.0.333,RADWIN-MIB-WINLINK1000::radiusAuthorizationSuccess,,,,,, Authorization Accept from Radius Server. +.1.3.6.1.4.1.4458.1000.0.334,RADWIN-MIB-WINLINK1000::duplicateMacCleared,,,,,, Indicates that duplicated MAC is cleared for specific SU and corresponding SU is unblocked. +.1.3.6.1.4.1.4458.1000.0.335,RADWIN-MIB-WINLINK1000::changeStateMuteMU,,,,,, Indicates MU state change in case of more than 2 MUs per train, MU can be muted (disable TX) or unmuted. +.1.3.6.1.4.1.4458.1000.0.336,RADWIN-MIB-WINLINK1000::illegalNumOfTrainIDs,,,,,, Indicates Illegal Amount Of Train IDs in case of 2 Trains Merge feature. +.1.3.6.1.4.1.4458.1000.0.337,RADWIN-MIB-WINLINK1000::pawsDBNotActive,,,,,, selected paws DB is not active alarm +.1.3.6.1.4.1.4458.1000.0.338,RADWIN-MIB-WINLINK1000::pawsDBNameMismatch,,,,,, selected paws DB name is not found in the weblist alarm +.1.3.6.1.4.1.4458.1000.0.339,RADWIN-MIB-WINLINK1000::pawsDBNotActiveCleared,,,,,, selected paws DB is not active alarm cleared +.1.3.6.1.4.1.4458.1000.0.340,RADWIN-MIB-WINLINK1000::pawsDBNameMismatchCleared,,,,,, selected paws DB name is not found in the weblist alarm Cleared +.1.3.6.1.4.1.4458.1000.0.341,RADWIN-MIB-WINLINK1000::linkPasswordChange,,,,,, Link password changed +.1.3.6.1.4.1.4458.1000.0.342,RADWIN-MIB-WINLINK1000::hbsDisconnectionMuIbhoAlarm,,,,,, Indicates a registered MU disconnection due to Ibho . +.1.3.6.1.4.1.4458.1000.1,RADWIN-MIB-WINLINK1000::winlink1000Odu,,,,,, +.1.3.6.1.4.1.4458.1000.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdmin,,,,,, +.1.3.6.1.4.1.4458.1000.1.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdmProductType,OCTET,read-only,,mandatory,,ODU configuration description. +.1.3.6.1.4.1.4458.1000.1.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdmHwRev,OCTET,read-only,,mandatory,,ODU Hardware Version. +.1.3.6.1.4.1.4458.1000.1.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduAdmSwRev,OCTET,read-only,,mandatory,,ODU Software Version. +.1.3.6.1.4.1.4458.1000.1.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduAdmLinkName,OCTET,read-write,,mandatory,,Link Name. A change is effective immediately. +.1.3.6.1.4.1.4458.1000.1.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduAdmResetCmd,INTEGER,read-write,,mandatory,,Reset Command. A set command with a value of 3 will cause a device reset. The read value is always 0. +.1.3.6.1.4.1.4458.1000.1.1.6,RADWIN-MIB-WINLINK1000::winlink1000OduAdmAddres,IpAddress,read-write,,mandatory,,ODU IP address. A change is effective after reset. The parameter is kept for backward compatibility. Using the alternative parameter: winlink1000OduAdmIpParamsCnfg is recommended. +.1.3.6.1.4.1.4458.1000.1.1.7,RADWIN-MIB-WINLINK1000::winlink1000OduAdmMask,IpAddress,read-write,,mandatory,,ODU Subnet Mask. A change is effective after reset. The parameter is kept for backward compatibility. Using the alternative parameter: winlink1000OduAdmIpParamsCnfg is recommended. +.1.3.6.1.4.1.4458.1000.1.1.8,RADWIN-MIB-WINLINK1000::winlink1000OduAdmGateway,IpAddress,read-write,,mandatory,,ODU default gateway. A change is effective after reset. The parameter is kept for backward compatibility. Using the alternative parameter: winlink1000OduAdmIpParamsCnfg is recommended. +.1.3.6.1.4.1.4458.1000.1.1.10,RADWIN-MIB-WINLINK1000::winlink1000OduAdmBroadcast,INTEGER,read-write,,mandatory,,This parameter is reserved for the Manager application provided with the product. +.1.3.6.1.4.1.4458.1000.1.1.11,RADWIN-MIB-WINLINK1000::winlink1000OduAdmHwModel,INTEGER,read-only,,mandatory,,Return the HW Model due to the HW Capabilities support +.1.3.6.1.4.1.4458.1000.1.1.12,RADWIN-MIB-WINLINK1000::winlink1000OduAdmHostsTable,,not-accessible,,mandatory,,Trap destinations table. Each trap destination is defined by an IP address and a UDP port. Up to 10 addresses can be configured. +.1.3.6.1.4.1.4458.1000.1.1.12.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdmHostsEntry,,not-accessible,winlink1000OduAdmHostsIndex,mandatory,,Trap destinations table entry. +.1.3.6.1.4.1.4458.1000.1.1.12.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdmHostsIndex,INTEGER,read-only,,mandatory,,Trap destinations table index. +.1.3.6.1.4.1.4458.1000.1.1.12.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdmHostsIp,IpAddress,read-write,,mandatory,,Trap destination IP address. A change is effective immediately. +.1.3.6.1.4.1.4458.1000.1.1.12.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduAdmHostsPort,INTEGER,read-write,,mandatory,,UDP port of the trap destination. A change is effective immediately. +.1.3.6.1.4.1.4458.1000.1.1.12.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduAdmHostsSecurityModel,INTEGER,read-write,,mandatory,snmpv1(1):snmpv3(3),Security model used for this trap generation. +.1.3.6.1.4.1.4458.1000.1.1.12.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduAdmHostsUserName,OCTET,read-write,,mandatory,,User name used to generate the snmpv3 trap. +.1.3.6.1.4.1.4458.1000.1.1.12.1.6,RADWIN-MIB-WINLINK1000::winlink1000OduAdmHostsPassword,OCTET,read-write,,mandatory,,Password used to generate the snmpv3 trap. +.1.3.6.1.4.1.4458.1000.1.1.12.1.7,RADWIN-MIB-WINLINK1000::winlink1000OduAdmHostsIPv6,OCTET,read-write,,mandatory,,Trap destination IPv6 address. A change is effective immediately. +.1.3.6.1.4.1.4458.1000.1.1.13,RADWIN-MIB-WINLINK1000::winlink1000OduBuzzerAdminState,INTEGER,read-write,,mandatory,,This parameter controls the activation of the buzzer while the unit is in install mode. A change is effective immediately. The valid values are: disabled (0), enabledAuto (1), enabledConstantly(2), advancedAuto (3). +.1.3.6.1.4.1.4458.1000.1.1.14,RADWIN-MIB-WINLINK1000::winlink1000OduProductId,OCTET,read-only,,mandatory,,This parameter is reserved for the Manager application provided with the product. +.1.3.6.1.4.1.4458.1000.1.1.15,RADWIN-MIB-WINLINK1000::winlink1000OduReadCommunity,OCTET,read-write,,mandatory,,Read Community String. This parameter always returns ***** when retrieving its value. It is used by the Manager application to change the Read Community String. The SNMP agent accepts only encrypted values. +.1.3.6.1.4.1.4458.1000.1.1.16,RADWIN-MIB-WINLINK1000::winlink1000OduReadWriteCommunity,OCTET,read-write,,mandatory,,Read/Write Community String. This parameter always returns ***** when retrieving its value. It is used by the Manager application to change the Read/Write Community String. The SNMP agent accepts only encrypted values. +.1.3.6.1.4.1.4458.1000.1.1.17,RADWIN-MIB-WINLINK1000::winlink1000OduTrapCommunity,OCTET,read-write,,mandatory,,Trap Community String. This parameter is used by the Manager application to change the Trap Community String. The SNMP agent accepts only encrypted values. +.1.3.6.1.4.1.4458.1000.1.1.18,RADWIN-MIB-WINLINK1000::winlink1000OduAdmSnmpAgentVersion,INTEGER,read-only,,mandatory,,Major version of the SNMP agent. +.1.3.6.1.4.1.4458.1000.1.1.19,RADWIN-MIB-WINLINK1000::winlink1000OduAdmRemoteSiteName,OCTET,read-only,,mandatory,,Remote site name. Returns the same value as sysLocation parameter of the remote site. +.1.3.6.1.4.1.4458.1000.1.1.20,RADWIN-MIB-WINLINK1000::winlink1000OduAdmSnmpAgentMinorVersion,INTEGER,read-only,,mandatory,,Minor version of the SNMP agent. +.1.3.6.1.4.1.4458.1000.1.1.21,RADWIN-MIB-WINLINK1000::winlink1000OduAdmLinkPassword,OCTET,read-write,,mandatory,,Link Password. This parameter always returns ***** when retrieving its value. It is used by the Manager application to change the Link Password. The SNMP agent accepts only encrypted values. +.1.3.6.1.4.1.4458.1000.1.1.22,RADWIN-MIB-WINLINK1000::winlink1000OduAdmSiteLinkPassword,OCTET,read-write,,mandatory,,Site Link Password. This parameter always returns ***** when retrieving its value. It is used by the Manager application to change the Link Password of the site. The SNMP agent accepts only encrypted values. +.1.3.6.1.4.1.4458.1000.1.1.23,RADWIN-MIB-WINLINK1000::winlink1000OduAdmDefaultPassword,INTEGER,read-only,,mandatory,default(1):nonDefault(2),This parameter indicates if the current Link Password is the default password. +.1.3.6.1.4.1.4458.1000.1.1.24,RADWIN-MIB-WINLINK1000::winlink1000OduAdmConnectionType,INTEGER,read-only,,mandatory,directConnection(1):indirectConnection(2):unknown(3),This parameter indicates if the Manager application is connected to the local ODU or to the remote ODU over the air. A value of 'unknown' indicates community string mismatch. +.1.3.6.1.4.1.4458.1000.1.1.25,RADWIN-MIB-WINLINK1000::winlink1000OduAdmBackToFactorySettingsCmd,INTEGER,read-write,,mandatory,withIP(1):withoutIP(2),Back to factory settings Command. A change is effective after reset. The read value is always 0. +.1.3.6.1.4.1.4458.1000.1.1.26,RADWIN-MIB-WINLINK1000::winlink1000OduAdmIpParamsCnfg,OCTET,read-write,,mandatory,,ODU IP address Configuration. The format is: ||| +.1.3.6.1.4.1.4458.1000.1.1.27,RADWIN-MIB-WINLINK1000::winlink1000OduAdmVlanID,INTEGER,read-write,,mandatory,,VLAN ID. Valid values are 1 to 4094. Initial value is 0 meaning VLAN unaware. +.1.3.6.1.4.1.4458.1000.1.1.28,RADWIN-MIB-WINLINK1000::winlink1000OduAdmVlanPriority,INTEGER,read-write,,mandatory,,VLAN Priority. 0 is lowest priority, 7 is highest priority. +.1.3.6.1.4.1.4458.1000.1.1.29,RADWIN-MIB-WINLINK1000::winlink1000OduAdmSN,OCTET,read-only,,mandatory,,ODU Serial Number +.1.3.6.1.4.1.4458.1000.1.1.30,RADWIN-MIB-WINLINK1000::winlink1000OduAdmProductName,OCTET,read-only,,mandatory,,This is the product name as it exists at EC +.1.3.6.1.4.1.4458.1000.1.1.31,RADWIN-MIB-WINLINK1000::winlink1000OduAdmActivationKey,OCTET,read-write,,mandatory,,Activates a general key. +.1.3.6.1.4.1.4458.1000.1.1.32,RADWIN-MIB-WINLINK1000::winlink1000OduAdmRmtPermittedOduType,OCTET,read-write,,mandatory,,Mobile Application: permitted partner OduType. +.1.3.6.1.4.1.4458.1000.1.1.33,RADWIN-MIB-WINLINK1000::winlink1000OduAdmCpuID,INTEGER,read-only,,mandatory,,CPU ID +.1.3.6.1.4.1.4458.1000.1.1.34,RADWIN-MIB-WINLINK1000::winlink1000OduAdmOvrdCmd,OCTET,read-write,,mandatory,,Ability to perform special command in the ODU. +.1.3.6.1.4.1.4458.1000.1.1.35,RADWIN-MIB-WINLINK1000::winlink1000OduAdmLinkMode,INTEGER,read-write,,mandatory,pmpHbs(1):pmpHsu(2):pmpHsuHyb(3):pmpHbsHyb(4),Unit PMP operation mode. +.1.3.6.1.4.1.4458.1000.1.1.36,RADWIN-MIB-WINLINK1000::winlink1000OduAdmActualConnectMode,INTEGER,read-only,,mandatory,none(1):ptp(2):ptmp(3),Unit connected as part to ptp or ptmp. +.1.3.6.1.4.1.4458.1000.1.1.37,RADWIN-MIB-WINLINK1000::winlink1000OduAdmAES256Support,INTEGER,read-only,,mandatory,notSupported(1):supported(2),AES-256 security support indication. +.1.3.6.1.4.1.4458.1000.1.1.38,RADWIN-MIB-WINLINK1000::winlink1000OduAdmAES256State,INTEGER,read-write,,mandatory,disabled(1):enabled(2),Enable/Disable AES-256 security mode over the air link. +.1.3.6.1.4.1.4458.1000.1.1.39,RADWIN-MIB-WINLINK1000::winlink1000OduAdmAES256Status,INTEGER,read-only,,mandatory,notOperating(1):partiallyOperating(2):operating(3),AES256 operating status +.1.3.6.1.4.1.4458.1000.1.1.40,RADWIN-MIB-WINLINK1000::winlink1000OduAdmBatterySavingShutdownTime,INTEGER,read-write,,mandatory,,Battery Saving Shutdown Time in minutes, 0 till battery run out, -1 if not supported. +.1.3.6.1.4.1.4458.1000.1.1.41,RADWIN-MIB-WINLINK1000::winlink1000OduAdmWiFiPowerMode,INTEGER,read-write,,mandatory,undefined-ReadOnly(1):powerON(2):powerOFF(3):alwaysON-ReadOnly(4):powerAUTO(5):limitedTime(6),WIFI unit power mode. +.1.3.6.1.4.1.4458.1000.1.1.42,RADWIN-MIB-WINLINK1000::winlink1000OduAdmShutdownTimer,INTEGER,read-only,,mandatory,,Shutdown Timer in seconds. +.1.3.6.1.4.1.4458.1000.1.1.43,RADWIN-MIB-WINLINK1000::winlink1000OduAdmGPSState,INTEGER,read-only,,mandatory,undefined(1):notSynchronized(2):fixed(3):shortCircuit(4):faulty(5):synchronizedGPS(6):synchronizedGlonassGPS(7):sychnornizedBeidouGPS(8),GPS state +.1.3.6.1.4.1.4458.1000.1.1.44,RADWIN-MIB-WINLINK1000::winlink1000OduAdmTemperatureC,INTEGER,read-only,,mandatory,,The temperature (Celsius) inside the Board. +.1.3.6.1.4.1.4458.1000.1.1.45,RADWIN-MIB-WINLINK1000::winlink1000OduAdmIPStackMode,INTEGER,read-write,,mandatory,v4(1):v6(2):v4andv6(3),The IP stack mode. +.1.3.6.1.4.1.4458.1000.1.1.46,RADWIN-MIB-WINLINK1000::winlink1000OduAdmIPv6ParamsCnfg,OCTET,read-write,,mandatory,,ODU IPv6 address Configuration. The format is: ||| +.1.3.6.1.4.1.4458.1000.1.1.47,RADWIN-MIB-WINLINK1000::winlink1000OduAdmIPv6Address,OCTET,read-only,,mandatory,,ODU IPv6 address. +.1.3.6.1.4.1.4458.1000.1.1.48,RADWIN-MIB-WINLINK1000::winlink1000OduAdmIPv6Prefix,INTEGER,read-only,,mandatory,,ODU IPv6 subnet mask. +.1.3.6.1.4.1.4458.1000.1.1.49,RADWIN-MIB-WINLINK1000::winlink1000OduAdmIPv6DefaultGateWay,OCTET,read-only,,mandatory,,ODU IPv6 default gateway. +.1.3.6.1.4.1.4458.1000.1.1.50,RADWIN-MIB-WINLINK1000::winlink1000OduAdmPowerConsumption,INTEGER,read-only,,mandatory,,Power Consumption (mWatt) +.1.3.6.1.4.1.4458.1000.1.1.51,RADWIN-MIB-WINLINK1000::winlink1000OduAdmWifi,,,,,, +.1.3.6.1.4.1.4458.1000.1.1.51.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdmWifiChannel,INTEGER,read-write,,mandatory,,Wifi Channel +.1.3.6.1.4.1.4458.1000.1.1.51.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdmWifiTxPower,INTEGER,read-write,,mandatory,,Wifi TX Power +.1.3.6.1.4.1.4458.1000.1.1.51.3,RADWIN-MIB-WINLINK1000::winlink1000OduAdmWifiSSID,OCTET,read-only,,mandatory,,Wifi SSID +.1.3.6.1.4.1.4458.1000.1.1.51.4,RADWIN-MIB-WINLINK1000::winlink1000OduAdmWifiSecurityType,INTEGER,read-only,,mandatory,open(1):wep(2):wpa2(3),Wifi Security type +.1.3.6.1.4.1.4458.1000.1.1.51.5,RADWIN-MIB-WINLINK1000::winlink1000OduAdmWifiPassword,OCTET,read-write,,mandatory,,Wifi Password +.1.3.6.1.4.1.4458.1000.1.1.51.6,RADWIN-MIB-WINLINK1000::winlink1000OduAdmWifiNetwork,IpAddress,read-write,,mandatory,,Wifi Network +.1.3.6.1.4.1.4458.1000.1.1.51.7,RADWIN-MIB-WINLINK1000::winlink1000OduAdmWifiRssi,INTEGER,read-only,,mandatory,,Wifi RSSI +.1.3.6.1.4.1.4458.1000.1.1.51.8,RADWIN-MIB-WINLINK1000::winlink1000OduAdmWifiStationMAC,OCTET,read-only,,mandatory,,Wifi Station MAC +.1.3.6.1.4.1.4458.1000.1.1.51.9,RADWIN-MIB-WINLINK1000::winlink1000OduAdmWifiRestart,INTEGER,read-write,,mandatory,,A set command with a value of 1 will cause a Wifi restart. The read value is always 0. +.1.3.6.1.4.1.4458.1000.1.1.51.10,RADWIN-MIB-WINLINK1000::winlink1000OduAdmWifiApStatus,INTEGER,read-only,,mandatory,off(1):on(2):connected(3):limited(4),Wifi AP Status +.1.3.6.1.4.1.4458.1000.1.1.51.11,RADWIN-MIB-WINLINK1000::winlink1000OduAdmWifiMaxTxPower,INTEGER,read-only,,mandatory,,Wifi Max Tx Power +.1.3.6.1.4.1.4458.1000.1.1.51.12,RADWIN-MIB-WINLINK1000::winlink1000OduAdmWiFiRssiTable,,not-accessible,,mandatory,,Table of Wifi Rssi And Mac adress per connected user. +.1.3.6.1.4.1.4458.1000.1.1.51.12.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdmWiFiRssiAndMacEntry,,not-accessible,winlink1000OduAdmWiFiRssiAndMacIndex,mandatory,,Wifi Rssi And Mac adress per connected user table entry. +.1.3.6.1.4.1.4458.1000.1.1.51.12.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdmWiFiRssiAndMacIndex,INTEGER,read-only,,mandatory,,Wifi Rssi And Mac adress per connected user Index. +.1.3.6.1.4.1.4458.1000.1.1.51.12.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdmWiFiRssiAndMac,OCTET,read-only,,mandatory,,Wifi Rssi And Mac adress per connected user value. +.1.3.6.1.4.1.4458.1000.1.1.52,RADWIN-MIB-WINLINK1000::winlink1000OduAdmBsaOperationMode,INTEGER,read-only,,mandatory,inactive(1):hbsTracking(2):hsuAlignment(3),BSA Operation Mode +.1.3.6.1.4.1.4458.1000.1.1.53,RADWIN-MIB-WINLINK1000::winlink1000OduAdmMngConnection,OCTET,read-write,,mandatory,,Management Connection +.1.3.6.1.4.1.4458.1000.1.1.54,RADWIN-MIB-WINLINK1000::winlink1000OduAdm1588TCSupport,INTEGER,read-only,,mandatory,notSupported(1):supported(2),Indicates that 1588TC license activated +.1.3.6.1.4.1.4458.1000.1.1.55,RADWIN-MIB-WINLINK1000::winlink1000OduAdmSyncESupport,INTEGER,read-only,,mandatory,notSupported(1):supported(2),ndicates that SyncE license activated +.1.3.6.1.4.1.4458.1000.1.1.56,RADWIN-MIB-WINLINK1000::winlink1000OduAdmRadioRev,OCTET,read-only,,mandatory,,Radio Revision +.1.3.6.1.4.1.4458.1000.1.1.57,RADWIN-MIB-WINLINK1000::winlink1000OduAdmProductRev,OCTET,read-only,,mandatory,,Product Revision +.1.3.6.1.4.1.4458.1000.1.1.58,RADWIN-MIB-WINLINK1000::winlink1000OduAdmPMPSUSupport,INTEGER,read-only,,mandatory,notSupported(1):supported(2),Indicates that PMP SU license is activated +.1.3.6.1.4.1.4458.1000.1.1.59,RADWIN-MIB-WINLINK1000::winlink1000OduAdmManagerDownloadURL,OCTET,read-write,,mandatory,,This is the URL from which management tool can be downloaded +.1.3.6.1.4.1.4458.1000.1.1.60,RADWIN-MIB-WINLINK1000::winlink1000OduAdmAntennaDescription,OCTET,read-only,,mandatory,,The is a description of the antenna connected to the ODU +.1.3.6.1.4.1.4458.1000.1.1.61,RADWIN-MIB-WINLINK1000::winlink1000OduAdmSwCapabilities,OCTET,read-only,,mandatory,,This is used to describe which Software Capabilities the current ODU supports +.1.3.6.1.4.1.4458.1000.1.1.62,RADWIN-MIB-WINLINK1000::winlink1000OduAdmSwChange,,,,,, +.1.3.6.1.4.1.4458.1000.1.1.62.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdmSwChangeCommand,OCTET,read-write,,mandatory,, Software Change Commands (string): Validate: 1, Mode Start: 2, Mode Download: 3, Mode, URL Upload: 4, Mode, URL Clean: 5, [SizeInBytes] Backup: 6, [DateTime] Mode: SW Upgrade(1), Backup/Restore(2) +.1.3.6.1.4.1.4458.1000.1.1.62.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdmSwChangeMetadata,OCTET,read-only,,mandatory,,Software Metadata String +.1.3.6.1.4.1.4458.1000.1.1.62.3,RADWIN-MIB-WINLINK1000::winlink1000OduAdmSwChangeStatus,INTEGER,read-only,,mandatory,,Software Change Operation status: None (1), In Progress (2), Pending Reset (3), Error (4) +.1.3.6.1.4.1.4458.1000.1.1.62.4,RADWIN-MIB-WINLINK1000::winlink1000OduAdmSwChangeError,OCTET,read-only,,mandatory,,Software Change Operation Error String +.1.3.6.1.4.1.4458.1000.1.1.63,RADWIN-MIB-WINLINK1000::winlink1000OduAdmRequesterSourceIp,IpAddress,read-only,,mandatory,,Returns the SNMP request's source IP address +.1.3.6.1.4.1.4458.1000.1.1.64,RADWIN-MIB-WINLINK1000::winlink1000OduAdmSecurityMode,INTEGER,read-write,,mandatory,standard(1):high(2):veryHigh(3), ODUs Security Mode : standard (1) high (2) veryHigh (3) +.1.3.6.1.4.1.4458.1000.1.1.65,RADWIN-MIB-WINLINK1000::winlink1000OduAdmTemporarilyDisableSecurityMode,INTEGER,read-write,,mandatory,,shall allow the user to disable high/very high Security Mode for 10 minutes +.1.3.6.1.4.1.4458.1000.1.1.66,RADWIN-MIB-WINLINK1000::winlink1000OduAdmSyslogServerIp,IpAddress,read-write,,mandatory,,Syslog server Ip address +.1.3.6.1.4.1.4458.1000.1.1.68,RADWIN-MIB-WINLINK1000::winlink1000OduAdmReportSwOperation,OCTET,read-write,,mandatory,,Reports Syslog client on software operation: Configuration Restore Software Upgrade Restore Default Full Restore Backup +.1.3.6.1.4.1.4458.1000.1.1.69,RADWIN-MIB-WINLINK1000::winlink1000OduAdmBootVersion,OCTET,read-only,,mandatory,,Card Boot version +.1.3.6.1.4.1.4458.1000.1.1.70,RADWIN-MIB-WINLINK1000::winlink1000OduAdmOneTimePassword,OCTET,read-only,,mandatory,,One Time Password +.1.3.6.1.4.1.4458.1000.1.1.71,RADWIN-MIB-WINLINK1000::winlink1000OduAdmSupportExtendedImage,INTEGER,read-only,,mandatory,na(1):supportedLoaded(2):supportedNotLoaded(3):notSupported(4),ODU Support Extended Image N/A (1), Supported and Loaded (2), Supported and not Loaded (3), Not Supported (4) +.1.3.6.1.4.1.4458.1000.1.1.72,RADWIN-MIB-WINLINK1000::winlink1000OduAdmFiM,,,,,, +.1.3.6.1.4.1.4458.1000.1.1.72.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdmFiMBS,,,,,, +.1.3.6.1.4.1.4458.1000.1.1.72.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdmFiMBSAir,,,,,, +.1.3.6.1.4.1.4458.1000.1.1.72.1.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSAirRUF,INTEGER,read-only,,mandatory,,For a limited spectrum case (when there are less then 5 channels), the number of available channels. A frequency can be reused for several TBS. +.1.3.6.1.4.1.4458.1000.1.1.72.1.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSAirITHOType,INTEGER,read-only,,mandatory,enabled(1):disabled(2):notSupported(3),Seamless Intra Mobile Handover. Return values: 1 - Enabled 2 - Disabled 3 - Not supported +.1.3.6.1.4.1.4458.1000.1.1.72.1.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSAirBIndex,INTEGER,read-only,,mandatory,,For limited spectrum availability, a frequency can be reused for several TBSs. To avoid interference TBSs with the same frrequency will tranmit the beacon with different offset. +.1.3.6.1.4.1.4458.1000.1.1.72.1.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSAirTSGIndex,INTEGER,read-only,,mandatory,,Used for Interference Mitigation for Co-channel Neighbors. Returns which TBS group use which timeslots in a frame. +.1.3.6.1.4.1.4458.1000.1.1.72.1.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSAirITHOMode,INTEGER,read-only,,mandatory,basedTput(1):basedRSS(2),ITHO decision based on: 1 - Tput 2 - RSS +.1.3.6.1.4.1.4458.1000.1.1.72.1.1.6,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSAirHOTable,,not-accessible,,mandatory,,Details of geographic neighbor of a TBS. This data is required to enable HO. +.1.3.6.1.4.1.4458.1000.1.1.72.1.1.6.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSAirHOEntry,,not-accessible,winlink1000OduAdminFiMBSAirHOIndex,mandatory,,Entry +.1.3.6.1.4.1.4458.1000.1.1.72.1.1.6.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSAirHOIndex,INTEGER,read-only,,mandatory,,index +.1.3.6.1.4.1.4458.1000.1.1.72.1.1.6.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSAirHOFreq,INTEGER,read-only,,mandatory,,The Frequncy (channel) of the neighboring TBS. +.1.3.6.1.4.1.4458.1000.1.1.72.1.1.6.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSAirHOIP,IpAddress,read-only,,mandatory,,The IP addresses of the neighboring TBS. +.1.3.6.1.4.1.4458.1000.1.1.72.1.1.7,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSAirCoCHIPTable,,not-accessible,,mandatory,,Details of TBSs that use the same channel. This is required for interference mitigation. +.1.3.6.1.4.1.4458.1000.1.1.72.1.1.7.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSAirCoCHIPEntry,,not-accessible,winlink1000OduAdminFiMBSAirCoCHIndex,mandatory,,Entry +.1.3.6.1.4.1.4458.1000.1.1.72.1.1.7.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSAirCoCHIndex,INTEGER,read-only,,mandatory,,index +.1.3.6.1.4.1.4458.1000.1.1.72.1.1.7.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSAirCoCHIP,IpAddress,read-only,,mandatory,,The IP addresses of the co-channel TBS. +.1.3.6.1.4.1.4458.1000.1.1.72.1.1.8,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSAirDepoTrackSegment,INTEGER,read-only,,mandatory,track(1):depot(2),This parameter indicates TBSs covering the depot using connectivity enhancements +.1.3.6.1.4.1.4458.1000.1.1.72.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdmFiMBSNet,,,,,, +.1.3.6.1.4.1.4458.1000.1.1.72.1.2.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSNetType,INTEGER,read-only,,mandatory,mdlEnabled(1):mdlDisabled(2):mdlNotSupported(3):l3(4):workModeAmount(5),Mobility method. Depends on the track-side network architecture: Layer 2-Single MAC, Layer 2-Multi MAC or L3 Return values: 1 - MDL Enabled 2 - MDL disabled 3 - MDL not supported 4 - L3 5 - Work mode amount +.1.3.6.1.4.1.4458.1000.1.1.72.1.2.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSNetCenterNetPort,INTEGER,read-only,,mandatory,,CenterNet controller port. Returns an integer. +.1.3.6.1.4.1.4458.1000.1.1.72.1.2.3,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSNetCenterNetTable,,not-accessible,,mandatory,,CenterNet controlle, table of entries defined in next MIB item +.1.3.6.1.4.1.4458.1000.1.1.72.1.2.3.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSNetCenterNetEntry,,not-accessible,winlink1000OduAdminFiMBSNetCenterNetIndex,mandatory,,CenterNet table entry type (Integer, IP address) +.1.3.6.1.4.1.4458.1000.1.1.72.1.2.3.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSNetCenterNetIndex,INTEGER,read-only,,mandatory,,CenterNet table current entry index. Set it to select an entry. +.1.3.6.1.4.1.4458.1000.1.1.72.1.2.3.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSNetCenterNetIP,IpAddress,read-only,,mandatory,,IP address +.1.3.6.1.4.1.4458.1000.1.1.72.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduAdmFiMBSSync,,,,,, +.1.3.6.1.4.1.4458.1000.1.1.72.1.3.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSSyncTC,INTEGER,read-only,,mandatory,enabled(1):disabled(2),1588 Transparent Clock (TC) status. Return values: 1 - Enabled 2 - Disabled +.1.3.6.1.4.1.4458.1000.1.1.72.1.3.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMBSSyncJitter,INTEGER,read-only,,mandatory,,Ethernet Hub Site Synchronization jitter mitigation: If there is a high level of wayside network jitter, use this to minimize the adverse affect of jitter on transmission synchronization. Returns an integer threshold value. +.1.3.6.1.4.1.4458.1000.1.1.72.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduAdmFiMBSEACS,,,,,, +.1.3.6.1.4.1.4458.1000.1.1.72.1.4.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMEACSEN,INTEGER,read-only,,mandatory,eacsDisabled(1):eacsEnabled(2),Enhanced automatic Channel Selection. When ON, enables to move to alternative channel if radar was detedcted for the current channel. +.1.3.6.1.4.1.4458.1000.1.1.72.1.4.3,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMEACSCHPRIO,INTEGER,read-only,,mandatory,,When EACS is activated, you can define alternative channels with priority. +.1.3.6.1.4.1.4458.1000.1.1.72.1.4.4,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMEACSDFSTRIGGER,INTEGER,read-only,,mandatory,regular(1):immediateReturn(2),Get the policy mode where an alternative channel with high priority was cleared: ignore or move back to it. Return values: 1 - Regular 2 - IR +.1.3.6.1.4.1.4458.1000.1.1.72.1.4.5,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMEACSPMAN,INTEGER,read-only,,mandatory,,When EACS is in use: Each TBS needs to know its predecessor TBS. This requires that each TBS sends it successor a periodic update message notifying its existence. The PNAM interval sets the time interval between these messages. +.1.3.6.1.4.1.4458.1000.1.1.72.1.4.6,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiBEACSSELFHEALING,INTEGER,read-only,,mandatory,selfHealSupportDisabled(1):selfHealSupportEnalbed(2),Enhanced automatic Channel Selection Self Healing functionality. When ON, enables Self Healing. +.1.3.6.1.4.1.4458.1000.1.1.72.1.4.7,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiBEacsSwitchStatus,OCTET,read-only,,mandatory,,Eacs last switch reason and switching counter. +.1.3.6.1.4.1.4458.1000.1.1.72.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdmFiMMU,,,,,, +.1.3.6.1.4.1.4458.1000.1.1.72.2.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdmFiMMUAir,,,,,, +.1.3.6.1.4.1.4458.1000.1.1.72.2.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMMUAirServBS,IpAddress,read-only,,mandatory,,Current BS the TMU actively linked to. +.1.3.6.1.4.1.4458.1000.1.1.72.2.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMMUAirRole,INTEGER,read-only,,mandatory,active(1):passive(2),TMU may be active or passive. This indicates the currents state. +.1.3.6.1.4.1.4458.1000.1.1.72.2.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMMUAirHOMode,INTEGER,read-only,,mandatory,upLink(1):aggregate(2):downLink(3),Applicability of the Intra Train Handover (ITHO) throughput ratio. Return values: 1 - Uplink 2 - Aggregate 3 - Downlink +.1.3.6.1.4.1.4458.1000.1.1.72.2.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMMUAirIBHOType,INTEGER,read-only,,mandatory,disabled(1):enabled(2),IBHO occurs when TMU moves from one TBS to the next. It is possible to force TMU to move to other TBS only when it is passive. +.1.3.6.1.4.1.4458.1000.1.1.72.2.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdmFiMMUNet,,,,,, +.1.3.6.1.4.1.4458.1000.1.1.72.2.2.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMMUNetR1IP,IpAddress,read-only,,mandatory,,Car router IP for L2 configuration. Returns an IP address string. +.1.3.6.1.4.1.4458.1000.1.1.72.2.2.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMMUNetLANTable,,not-accessible,,mandatory,,For L3 network types: A list of IP subnet prefixes and subnet masks for the train. No more than 5 can be entered. +.1.3.6.1.4.1.4458.1000.1.1.72.2.2.2.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMMUNetLANEntry,,not-accessible,winlink1000OduAdminFiMMUNetLANIndex,mandatory,,Entry +.1.3.6.1.4.1.4458.1000.1.1.72.2.2.2.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMMUNetLANIndex,INTEGER,read-only,,mandatory,,Index +.1.3.6.1.4.1.4458.1000.1.1.72.2.2.2.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMMUNetLAN,IpAddress,read-only,,mandatory,,LAN prefix +.1.3.6.1.4.1.4458.1000.1.1.72.2.2.2.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMMUNetMaskLAN,IpAddress,read-only,,mandatory,,LAN mask +.1.3.6.1.4.1.4458.1000.1.1.72.2.2.3,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMMUNetL3VIP,IpAddress,read-only,,mandatory,,For L3 network types: The TMUs on-board share a virtual IP that serves as the default gateway for the on-board router (the actual TMU accessed is the active TMU). +.1.3.6.1.4.1.4458.1000.1.1.72.2.2.4,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMMUNetPeer,IpAddress,read-only,,mandatory,,The IP of the peer TMU or TMUs in the same train. +.1.3.6.1.4.1.4458.1000.1.1.72.2.2.5,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMMUNetType,INTEGER,read-only,,mandatory,mdlEnabled(1):mdlDisabled(2):mdlNotSupported(3):l3(4):workModeAmount(5),Mobility method. Depends on the track-side network architecture: Layer 2-Single MAC, Layer 2-Multi MAC or L3 Return values: 1 - MDL Enabled 2 - MDL disabled 3 - MDL not supported 4 - L3 5 - Work mode amount +.1.3.6.1.4.1.4458.1000.1.1.72.2.2.6,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMMUNetAddLearnVLANTable,,not-accessible,,mandatory,,There is an option to send relearning frames between TMUs via VLAN - not in use, ask PS before using this option +.1.3.6.1.4.1.4458.1000.1.1.72.2.2.6.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMMUNetAddLearnVLANEntry,,not-accessible,winlink1000OduAdminFiMMUNetAddLearnVLANIndex,mandatory,,entry +.1.3.6.1.4.1.4458.1000.1.1.72.2.2.6.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMMUNetAddLearnVLANIndex,INTEGER,read-only,,mandatory,,Index +.1.3.6.1.4.1.4458.1000.1.1.72.2.2.6.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMMUNetAddLearnVLAN,INTEGER,read-only,,mandatory,,VLAN +.1.3.6.1.4.1.4458.1000.1.1.72.2.2.7,RADWIN-MIB-WINLINK1000::winlink1000OduAdminFiMMUIthoMuMode,INTEGER,read-write,,mandatory,singleMode(1):dualMode(2),Mobility : option to set Mu Itho mode of behaviour values: 1 - Single Mode - single Mu on train does not perform itho 2 - Dual Mode - Mu have a peer and performs Itho +.1.3.6.1.4.1.4458.1000.1.1.73,RADWIN-MIB-WINLINK1000::winlink1000OduAdmDnsServerAddress,OCTET,read-write,,mandatory,,Primary and Secondary DNS addresses: || +.1.3.6.1.4.1.4458.1000.1.1.74,RADWIN-MIB-WINLINK1000::winlink1000OduAdmOwner,OCTET,read-write,,mandatory,,Name of Individual/business that owns the device +.1.3.6.1.4.1.4458.1000.1.1.75,RADWIN-MIB-WINLINK1000::winlink1000OduAdmContactDetails,OCTET,read-write,,mandatory,,Contact Details: |||||| +.1.3.6.1.4.1.4458.1000.1.1.76,RADWIN-MIB-WINLINK1000::winlink1000OduAdmSDRRevision,OCTET,read-only,,mandatory,,SDR (Software defined radio) revision +.1.3.6.1.4.1.4458.1000.1.1.77,RADWIN-MIB-WINLINK1000::winlink1000OduAdmDyingGaspStatus,INTEGER,read-only,,mandatory,notSupportedHW(1):supportedOnlyOnSu(2):notActiveCheckPoe(3):active(4):testing(5),Activity status of Dying Gasp: power fail detection. Return values: 1 - Not supported- no HW 2 - Not active- supported only on the SU end 3 - Not active- please check your PoE device 4 - Active 5 - Testing +.1.3.6.1.4.1.4458.1000.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduService,,,,,, +.1.3.6.1.4.1.4458.1000.1.2.1,RADWIN-MIB-WINLINK1000::winlink1000OduSrvMode,INTEGER,read-write,,mandatory,installMode(1):normalMode(2):slaveMode(3):tempInstallMode(4):inactiveMode(5),System mode. The only values that can be set are installMode and slaveMode; normalMode reserved to the Manager application provided with the product. A change is effective after link re-synchronization. +.1.3.6.1.4.1.4458.1000.1.2.3,RADWIN-MIB-WINLINK1000::winlink1000OduSrvBridging,INTEGER,read-only,,mandatory,,Bridging Mode. Valid values are: disabled (0), enabled (1). +.1.3.6.1.4.1.4458.1000.1.2.4,RADWIN-MIB-WINLINK1000::winlink1000OduServiceRingTopology,,,,,, +.1.3.6.1.4.1.4458.1000.1.2.4.1,RADWIN-MIB-WINLINK1000::winlink1000OduSrvRingLinkMode,INTEGER,read-write,,mandatory,independentLink(1):nonRpl(2):rpl(3),Mode of the link regarding ring topology. +.1.3.6.1.4.1.4458.1000.1.2.4.2,RADWIN-MIB-WINLINK1000::winlink1000OduSrvRingTopologySupported,INTEGER,read-only,,mandatory,notSupported(1):supported(2),Ring Topology, options are: supported, not supported +.1.3.6.1.4.1.4458.1000.1.2.4.3,RADWIN-MIB-WINLINK1000::winlink1000OduSrvRingVlanIdTable,,not-accessible,,mandatory,,Ring VLAN IDs table. +.1.3.6.1.4.1.4458.1000.1.2.4.3.1,RADWIN-MIB-WINLINK1000::winlink1000OduSrvRingVlanIdEntry,,not-accessible,winlink1000OduSrvRingVlanIdIndex,mandatory,,VLAN ID of the internal ring messages. Valid values are 1 to 4094. Initial value is 0 meaning VLAN unaware. +.1.3.6.1.4.1.4458.1000.1.2.4.3.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduSrvRingVlanIdIndex,INTEGER,read-only,,mandatory,,Index of VLAN ID of the internal ring messages. +.1.3.6.1.4.1.4458.1000.1.2.4.3.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduSrvRingVlanId,INTEGER,read-write,,mandatory,,VLAN ID of the internal ring messages. Valid values are 1 to 4094. Initial value is 0 meaning VLAN unaware. +.1.3.6.1.4.1.4458.1000.1.2.4.4,RADWIN-MIB-WINLINK1000::winlink1000OduSrvRingEthStatus,INTEGER,read-only,,mandatory,unblocked(1):blocked(2):notApplicable(3),Represents the Ethernet service blocking state of a Rings link +.1.3.6.1.4.1.4458.1000.1.2.4.5,RADWIN-MIB-WINLINK1000::winlink1000OduSrvRingMaxAllowedTimeFromLastRpm,INTEGER,read-write,,mandatory,,Defines the minimal time (in ms) required for determination of ring failure. +.1.3.6.1.4.1.4458.1000.1.2.4.6,RADWIN-MIB-WINLINK1000::winlink1000OduSrvRingWTR,INTEGER,read-write,,mandatory,,Defines the minimal time (in ms) required for ring recovery. +.1.3.6.1.4.1.4458.1000.1.2.5,RADWIN-MIB-WINLINK1000::winlink1000OduServiceQoS,,,,,, +.1.3.6.1.4.1.4458.1000.1.2.5.1,RADWIN-MIB-WINLINK1000::winlink1000OduSrvQoSMode,INTEGER,read-write,,mandatory,notSupported(1):notActive(2):classVlan(3):classDiffserv(4),Mode of QoS feature. +.1.3.6.1.4.1.4458.1000.1.2.5.2,RADWIN-MIB-WINLINK1000::winlink1000OduSrvQoSConfTable,,not-accessible,,mandatory,,QoS configuration table. +.1.3.6.1.4.1.4458.1000.1.2.5.2.1,RADWIN-MIB-WINLINK1000::winlink1000OduSrvQoSConfEntry,,not-accessible,winlink1000OduSrvQoSConfIndex,mandatory,,QoS configuration table. +.1.3.6.1.4.1.4458.1000.1.2.5.2.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduSrvQoSConfIndex,INTEGER,read-only,,mandatory,,Index of QoS Configuration. +.1.3.6.1.4.1.4458.1000.1.2.5.2.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduSrvConfVlanQGroups,INTEGER,read-only,,mandatory,,Frames classification according to VLAN Priority IDs. +.1.3.6.1.4.1.4458.1000.1.2.5.2.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduSrvConfDiffservQGroups,INTEGER,read-only,,mandatory,,Frames classification according to Diffserv. +.1.3.6.1.4.1.4458.1000.1.2.5.2.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduSrvConfQueMir,INTEGER,read-write,,mandatory,,Desired Private MIR. +.1.3.6.1.4.1.4458.1000.1.2.5.2.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduSrvConfQueWeight,INTEGER,read-write,,mandatory,,QoS queueu's weights in percent. +.1.3.6.1.4.1.4458.1000.1.2.5.3,RADWIN-MIB-WINLINK1000::winlink1000OduSrvQoSVlanQGroupsSetStr,OCTET,read-write,,mandatory,,Frames classification according to VLAN IDs string for set. +.1.3.6.1.4.1.4458.1000.1.2.5.4,RADWIN-MIB-WINLINK1000::winlink1000OduSrvQoSDiffservQGroupsSetStr,OCTET,read-write,,mandatory,,Frames classification according to Diffserv IDs string for set. +.1.3.6.1.4.1.4458.1000.1.2.5.5,RADWIN-MIB-WINLINK1000::winlink1000OduSrvQoSMaxRTQuePercent,INTEGER,read-only,,mandatory,,Maximal percent for RT & NRT queues. +.1.3.6.1.4.1.4458.1000.1.2.6,RADWIN-MIB-WINLINK1000::winlink1000OduServiceVlan,,,,,, +.1.3.6.1.4.1.4458.1000.1.2.6.1,RADWIN-MIB-WINLINK1000::winlink1000OduSrvVlanSupport,INTEGER,read-only,,mandatory,notSupported(1):supported(2):available(3),ODU Ethernet port VLAN support and configuration availability indication. 1 - ODU VLAN Functionality Not Supported 2 - ODU VLAN Functionality Supported 3 - ODU VLAN Functionality Supported and Available +.1.3.6.1.4.1.4458.1000.1.2.6.2,RADWIN-MIB-WINLINK1000::winlink1000OduSrvVlanIngressMode,INTEGER,read-write,,mandatory,transparent(1):untagAll(2):filter(3),ODU Ethernet port ingress VLAN mode. +.1.3.6.1.4.1.4458.1000.1.2.6.3,RADWIN-MIB-WINLINK1000::winlink1000OduSrvVlanEgressMode,INTEGER,read-write,,mandatory,transparent(1):tag(2):provider(3),ODU Ethernet port egress VLAN mode. +.1.3.6.1.4.1.4458.1000.1.2.6.4,RADWIN-MIB-WINLINK1000::winlink1000OduSrvEgressTag,INTEGER,read-write,,mandatory,,ODU ethernet port egress VLAN tag. Right most digit is Vlan priority (0-7), other digits compose Vlan Id (2-4094) +.1.3.6.1.4.1.4458.1000.1.2.6.5,RADWIN-MIB-WINLINK1000::winlink1000OduSrvEgressProviderTag,INTEGER,read-write,,mandatory,,ODU ethernet port egress Provider VLAN tag. Right most digit is Vlan priority (0-7), other digits compose Vlan Id (2-4094) +.1.3.6.1.4.1.4458.1000.1.2.6.6,RADWIN-MIB-WINLINK1000::winlink1000OduSrvVlanIngressAllowedVIDs,OCTET,read-write,,mandatory,,ODU ethernet port VLAN IDs that will not be filtered on ingress. w|w|w|w|w|w|w|w| ( where w = {0-4094} and w != 1 ) +.1.3.6.1.4.1.4458.1000.1.2.6.7,RADWIN-MIB-WINLINK1000::winlink1000OduSrvVlanDisable,INTEGER,read-write,,mandatory,,Disable VLAN functionality. The following values can be set: 3 - Disable ODU & IDU VLAN Configurations. +.1.3.6.1.4.1.4458.1000.1.2.6.8,RADWIN-MIB-WINLINK1000::winlink1000OduServiceVlanProviderListTPIDstr,OCTET,read-only,,mandatory,,Holds the possible Provider TPIDs. +.1.3.6.1.4.1.4458.1000.1.2.7,RADWIN-MIB-WINLINK1000::winlink1000OduDhcpRelayAgent,INTEGER,read-write,,mandatory,disabled(1):enabled(2),DHCP Relay Agent Mode +.1.3.6.1.4.1.4458.1000.1.2.8,RADWIN-MIB-WINLINK1000::winlink1000OduServiceUserAuthentication,,,,,, +.1.3.6.1.4.1.4458.1000.1.2.8.1,RADWIN-MIB-WINLINK1000::winlink1000OduServiceUserAuthenticationMode,INTEGER,read-write,,mandatory,disable(1):enable(2),RADIUS User Authentication Mode - Disable / Enable +.1.3.6.1.4.1.4458.1000.1.2.8.2,RADWIN-MIB-WINLINK1000::winlink1000OduServiceUserAuthenticationBypassTable,,not-accessible,,mandatory,,RADIUS User Authentication Bypass Table +.1.3.6.1.4.1.4458.1000.1.2.8.2.1,RADWIN-MIB-WINLINK1000::winlink1000OduServiceUserAuthenticationBypassEntry,,not-accessible,winlink1000OduServiceUserAuthenticationBypassIndex,mandatory,,RADIUS User Authentication Table Bypass Entry +.1.3.6.1.4.1.4458.1000.1.2.8.2.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduServiceUserAuthenticationBypassIndex,INTEGER,read-only,,mandatory,,RADIUS User Authentication Table Bypass Index +.1.3.6.1.4.1.4458.1000.1.2.8.2.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduServiceUserAuthenticationBypassIp,IpAddress,read-write,,mandatory,,RADIUS User Authentication Bypass Ip Address +.1.3.6.1.4.1.4458.1000.1.2.8.2.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduServiceUserAuthenticationBypassNetMask,IpAddress,read-write,,mandatory,,RADIUS User Authentication Bypass Netmask Address +.1.3.6.1.4.1.4458.1000.1.2.8.3,RADWIN-MIB-WINLINK1000::winlink1000OduServiceUserAuthenticationRadiusServerTable,,not-accessible,,mandatory,,Holds the Radius User Authentication Server configurations +.1.3.6.1.4.1.4458.1000.1.2.8.3.1,RADWIN-MIB-WINLINK1000::winlink1000OduServiceUserAuthenticationRadiusServerEntry,,not-accessible,winlink1000OduServiceUserAuthenticationRadiusServerIndex,mandatory,,HBS User Authentication Radius Server table entry. +.1.3.6.1.4.1.4458.1000.1.2.8.3.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduServiceUserAuthenticationRadiusServerIndex,INTEGER,read-only,,mandatory,,User Authentication Radius Server Table index. +.1.3.6.1.4.1.4458.1000.1.2.8.3.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduServiceUserAuthenticationRadiusServerIpAddr,IpAddress,read-write,,mandatory,,User Authentication Radius Server IP +.1.3.6.1.4.1.4458.1000.1.2.8.3.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduServiceUserAuthenticationRadiusServerPort,INTEGER,read-write,,mandatory,,User Authentication Radius Server Port +.1.3.6.1.4.1.4458.1000.1.2.8.3.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduServiceUserAuthenticationRadiusServerSecret,OCTET,read-write,,mandatory,,User Authentication Radius Server Secret +.1.3.6.1.4.1.4458.1000.1.2.8.3.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduServiceUserAuthenticationRadiusServerConnectivity,INTEGER,read-write,,mandatory,success(1):noServerResponse(2):noServer(3):testing(4):badSecret(5):timeout(6),User Authentication Radius Server connectivity status +.1.3.6.1.4.1.4458.1000.1.2.8.3.1.6,RADWIN-MIB-WINLINK1000::winlink1000OduServiceUserAuthenticationRadiusServerNumOfRetries,INTEGER,read-write,,mandatory,,User Authentication Radius Server number of retries +.1.3.6.1.4.1.4458.1000.1.2.8.3.1.7,RADWIN-MIB-WINLINK1000::winlink1000OduServiceUserAuthenticationRadiusServerTimeout,INTEGER,read-write,,mandatory,,User Authentication Radius Server timeout +.1.3.6.1.4.1.4458.1000.1.2.8.4,RADWIN-MIB-WINLINK1000::winlink1000OduServiceUserAuthenticationRadiusAccess,OCTET,read-write,,mandatory,,RADIUS User Authentication Radius Access +.1.3.6.1.4.1.4458.1000.1.2.8.5,RADWIN-MIB-WINLINK1000::winlink1000OduServiceUserAuthenticationToken,OCTET,read-write,,mandatory,,RADIUS User Authentication Token +.1.3.6.1.4.1.4458.1000.1.2.9,RADWIN-MIB-WINLINK1000::winlink1000OduServiceAcl,,,,,, +.1.3.6.1.4.1.4458.1000.1.2.9.1,RADWIN-MIB-WINLINK1000::winlink1000OduServiceAclMode,INTEGER,read-write,,mandatory,disable(1):enable(2),Acl Mode - Disable / Enable +.1.3.6.1.4.1.4458.1000.1.2.9.2,RADWIN-MIB-WINLINK1000::winlink1000OduServiceAclTable,,not-accessible,,mandatory,,Acl Table +.1.3.6.1.4.1.4458.1000.1.2.9.2.1,RADWIN-MIB-WINLINK1000::winlink1000OduServiceAclEntry,,not-accessible,winlink1000OduServiceAclIndex,mandatory,,Acl Table Entry +.1.3.6.1.4.1.4458.1000.1.2.9.2.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduServiceAclIndex,INTEGER,read-only,,mandatory,,Acl Table Index +.1.3.6.1.4.1.4458.1000.1.2.9.2.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduServiceAclIp,IpAddress,read-write,,mandatory,,Acl Ip Address +.1.3.6.1.4.1.4458.1000.1.2.9.2.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduServiceAclNetMask,IpAddress,read-write,,mandatory,,Acl Netmask Address +.1.3.6.1.4.1.4458.1000.1.2.10,RADWIN-MIB-WINLINK1000::winlink1000OduDhcpRelayAgentCircuitIdSource,INTEGER,read-write,,mandatory,hbsMacAaddress(1):hbsName(2):hbsSerial(3),DHCP Relay Agent Circuit ID Source +.1.3.6.1.4.1.4458.1000.1.2.11,RADWIN-MIB-WINLINK1000::winlink1000OduDhcpRelayAgentRemoteIdSource,INTEGER,read-write,,mandatory,hsuMacAddress(1):hsuName(2):hsuSerial(3),DHCP Relay Agent Remote ID Source +.1.3.6.1.4.1.4458.1000.1.2.12,RADWIN-MIB-WINLINK1000::winlink1000OduDhcpRelayAgentConcatenatedCircuitIdMode,INTEGER,read-write,,mandatory,disable(1):enable(2),DHCP Relay Agent Concatenated Circuit Id Mode +.1.3.6.1.4.1.4458.1000.1.2.13,RADWIN-MIB-WINLINK1000::winlink1000OduServiceRedundancy,,,,,, +.1.3.6.1.4.1.4458.1000.1.2.13.1,RADWIN-MIB-WINLINK1000::winlink1000OduSrvRedundancyRole,INTEGER,read-write,,mandatory,primary(1):secondary(2):none(3),Mode of the link regarding Service Redundancy. +.1.3.6.1.4.1.4458.1000.1.2.13.2,RADWIN-MIB-WINLINK1000::winlink1000OduSrvRedundancyPeerIP,IpAddress,read-write,,mandatory,,Peer IP for 1 plus 1 service one bts is active the other is in standby state. +.1.3.6.1.4.1.4458.1000.1.2.13.3,RADWIN-MIB-WINLINK1000::winlink1000OduSrvRedundancyCheckPointIP,IpAddress,read-write,,mandatory,,Checkpoint Ip to test network connectivity +.1.3.6.1.4.1.4458.1000.1.2.13.4,RADWIN-MIB-WINLINK1000::winlink1000OduSrvRedundancyFailureReason,OCTET,read-only,,mandatory,,1 plus 1 feature display reason of failure +.1.3.6.1.4.1.4458.1000.1.2.13.5,RADWIN-MIB-WINLINK1000::winlink1000OduSrvRedundancyCpeWirelessConnectionTO,IpAddress,read-write,,mandatory,,Wireless Connection Timeout (sec). Applicable at Primary CPE only +.1.3.6.1.4.1.4458.1000.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduEthernet,,,,,, +.1.3.6.1.4.1.4458.1000.1.3.1,RADWIN-MIB-WINLINK1000::winlink1000OduEthernetRemainingRate,INTEGER,read-only,,mandatory,,Current Ethernet bandwidth in bps. +.1.3.6.1.4.1.4458.1000.1.3.2,RADWIN-MIB-WINLINK1000::winlink1000OduEthernetIfTable,,not-accessible,,mandatory,,ODU Ethernet Interface table. +.1.3.6.1.4.1.4458.1000.1.3.2.1,RADWIN-MIB-WINLINK1000::winlink1000OduEthernetIfEntry,,not-accessible,winlink1000OduEthernetIfIndex,mandatory,,ODU Ethernet Interface table entry. +.1.3.6.1.4.1.4458.1000.1.3.2.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduEthernetIfIndex,INTEGER,read-only,,mandatory,,ODU Ethernet Interface Index. +.1.3.6.1.4.1.4458.1000.1.3.2.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduEthernetIfAddress,OCTET,read-only,,mandatory,,ODU MAC address. +.1.3.6.1.4.1.4458.1000.1.3.2.1.6,RADWIN-MIB-WINLINK1000::winlink1000OduEthernetIfAdminStatus,INTEGER,read-write,,mandatory,portAutoSense(1):portAutoSense100Mbps(5):forceHalfDuplex10Mbps(10):forceFullDuplex10Mbps(11):forceHalfDuplex100Mbps(15):forceFullDuplex100Mbps(16):forceFullDuplex1000Mbps(21):disablePoePort(254):disablePort(255),Required state of the interface. +.1.3.6.1.4.1.4458.1000.1.3.2.1.7,RADWIN-MIB-WINLINK1000::winlink1000OduEthernetIfOperStatus,INTEGER,read-only,,mandatory,notConnected(1):connectedHalfDuplex10Mbps(10):connectedFullDuplex10Mbps(11):connectedHalfDuplex100Mbps(15):connectedFullDuplex100Mbps(16):connectedHalfDuplex1000Mbps(20):connectedFullDuplex1000Mbps(21):unknown(65535),Current operational state of the interface. +.1.3.6.1.4.1.4458.1000.1.3.2.1.8,RADWIN-MIB-WINLINK1000::winlink1000OduEthernetIfFailAction,INTEGER,read-write,,mandatory,faNoAction(1):faForceHalfDuplex10Mbps(10):faForceFullDuplex10Mbps(11):faDisablePort(255),Failure action of the interface. +.1.3.6.1.4.1.4458.1000.1.3.2.1.9,RADWIN-MIB-WINLINK1000::winlink1000OduEthernetIf1588v2PTPEventRXRate,INTEGER,read-only,,mandatory,,For debug use +.1.3.6.1.4.1.4458.1000.1.3.2.1.10,RADWIN-MIB-WINLINK1000::winlink1000OduEthernetIf1588v2PTPEventTXRate,INTEGER,read-only,,mandatory,,For debug use +.1.3.6.1.4.1.4458.1000.1.3.3,RADWIN-MIB-WINLINK1000::winlink1000OduEthernetNumOfPorts,INTEGER,read-only,,mandatory,,Number of ODU network interfaces. +.1.3.6.1.4.1.4458.1000.1.3.4,RADWIN-MIB-WINLINK1000::winlink1000OduEthernetGbeSupported,INTEGER,read-only,,mandatory,notSupported(1):supported(2),Supported Giga bit Ethernet in ODU. +.1.3.6.1.4.1.4458.1000.1.3.5,RADWIN-MIB-WINLINK1000::winlink1000OduEthernetSfpProperties,OCTET,read-only,,mandatory,,Sfp port properties. +.1.3.6.1.4.1.4458.1000.1.3.6,RADWIN-MIB-WINLINK1000::winlink1000OduEthernetMainTrafficPort,INTEGER,read-write,,mandatory,lan1(1):lan2(2),Ethernet Main Traffic Port. +.1.3.6.1.4.1.4458.1000.1.3.7,RADWIN-MIB-WINLINK1000::winlink1000OduEthernetRestartCounter,INTEGER,read-only,,mandatory,,Ethernet Restart Counter +.1.3.6.1.4.1.4458.1000.1.3.8,RADWIN-MIB-WINLINK1000::winlink1000OduEthernetSmart100M,INTEGER,read-write,,mandatory,disable(1):enable(2),Ethernet Smart 100M +.1.3.6.1.4.1.4458.1000.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduBridge,,,,,, +.1.3.6.1.4.1.4458.1000.1.4.1,RADWIN-MIB-WINLINK1000::winlink1000OduBridgeBase,,,,,, +.1.3.6.1.4.1.4458.1000.1.4.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduBridgeBasePortTable,,not-accessible,,mandatory,,ODU Bridge Ports table. +.1.3.6.1.4.1.4458.1000.1.4.1.4.1,RADWIN-MIB-WINLINK1000::winlink1000OduBridgeBasePortEntry,,not-accessible,winlink1000OduBridgeBasePortIndex,mandatory,,ODU Bridge Ports table entry. +.1.3.6.1.4.1.4458.1000.1.4.1.4.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduBridgeBasePortIndex,INTEGER,read-only,,mandatory,,ODU Bridge Port Number. +.1.3.6.1.4.1.4458.1000.1.4.1.4.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduBridgeBaseIfIndex,INTEGER,read-only,,mandatory,,IfIndex corresponding to ODU Bridge port. +.1.3.6.1.4.1.4458.1000.1.4.4,RADWIN-MIB-WINLINK1000::winlink1000OduBridgeTp,,,,,, +.1.3.6.1.4.1.4458.1000.1.4.4.3,RADWIN-MIB-WINLINK1000::winlink1000OduBridgeTpPortTable,,not-accessible,,mandatory,,ODU Transparent Bridge Ports table. +.1.3.6.1.4.1.4458.1000.1.4.4.3.1,RADWIN-MIB-WINLINK1000::winlink1000OduBridgeTpPortEntry,,not-accessible,winlink1000OduBridgeTpPortIndex,mandatory,,ODU Transparent Bridge Ports table entry. +.1.3.6.1.4.1.4458.1000.1.4.4.3.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduBridgeTpPortIndex,INTEGER,read-only,,mandatory,,ODU Transparent Bridge Port Number. +.1.3.6.1.4.1.4458.1000.1.4.4.3.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduBridgeTpPortInFrames,Counter32,read-only,,mandatory,,Number of frames received by this port. +.1.3.6.1.4.1.4458.1000.1.4.4.3.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduBridgeTpPortOutFrames,Counter32,read-only,,mandatory,,Number of frames transmitted by this port. +.1.3.6.1.4.1.4458.1000.1.4.4.3.1.101,RADWIN-MIB-WINLINK1000::winlink1000OduBridgeTpPortInBytes,Counter32,read-only,,mandatory,,Number of bytes received by this port. +.1.3.6.1.4.1.4458.1000.1.4.4.3.1.102,RADWIN-MIB-WINLINK1000::winlink1000OduBridgeTpPortOutBytes,Counter32,read-only,,mandatory,,Number of bytes transmitted by this port. +.1.3.6.1.4.1.4458.1000.1.4.4.101,RADWIN-MIB-WINLINK1000::winlink1000OduBridgeTpMode,INTEGER,read-write,,mandatory,,ODU bridge mode. A change is effective after reset. Valid values: hubMode (0), bridgeMode (1). +.1.3.6.1.4.1.4458.1000.1.4.4.102,RADWIN-MIB-WINLINK1000::winlink1000OduBridgeConfigMode,INTEGER,read-only,,mandatory,enable(1):disable(2),ODU bridge configuration mode +.1.3.6.1.4.1.4458.1000.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduAir,,,,,, +.1.3.6.1.4.1.4458.1000.1.5.1,RADWIN-MIB-WINLINK1000::winlink1000OduAirFreq,INTEGER,read-write,,mandatory,,Installation Center Frequency. Valid values are product dependent. A change is effective after link re-synchronization. +.1.3.6.1.4.1.4458.1000.1.5.2,RADWIN-MIB-WINLINK1000::winlink1000OduAirDesiredRate,INTEGER,read-write,,deprecated,,Deprecated parameter, actual behavior is read-only. Required Air Rate. For Channel Bandwidth of 20, 10, 5 MHz divide the value by 1, 2, 4 respectively. +.1.3.6.1.4.1.4458.1000.1.5.3,RADWIN-MIB-WINLINK1000::winlink1000OduAirSSID,OCTET,read-write,,mandatory,,Reserved for the Manager application provided with the product. The Sector ID in Point-To-Multi-Point systems. +.1.3.6.1.4.1.4458.1000.1.5.4,RADWIN-MIB-WINLINK1000::winlink1000OduAirTxPower,INTEGER,read-write,,mandatory,,Required Transmit power in dBm . This is a nominal value while the actual transmit power includes additional attenuation. The min and max values are product specific. A change is effective immediately. +.1.3.6.1.4.1.4458.1000.1.5.5,RADWIN-MIB-WINLINK1000::winlink1000OduAirSesState,INTEGER,read-only,,mandatory,sessionDown(1):basicRate(2):active(3):installation(4):scanning(5):probing(6):transmitting(7):activeWithDefaultEncryptionKey(8):installationWithDefaultEncryptionKey(9):bitFailed(10):activeWithVersionsMismatch(11):installationWithVersionsMismatch(12):inactive(13):iduIncompatible(14):spectrumAnalysis(15),Current Link State. The value is active (3) during normal operation. +.1.3.6.1.4.1.4458.1000.1.5.6,RADWIN-MIB-WINLINK1000::winlink1000OduAirMstrSlv,INTEGER,read-only,,mandatory,,This parameter indicates if the device was automatically selected into the radio link master or slave. The value is undefined if there is no link. The value is relevant only for point to point systems. +.1.3.6.1.4.1.4458.1000.1.5.8,RADWIN-MIB-WINLINK1000::winlink1000OduAirResync,INTEGER,read-write,,mandatory,,Setting this parameter to 1 will cause the link to restart the synchronization process. +.1.3.6.1.4.1.4458.1000.1.5.9,RADWIN-MIB-WINLINK1000::winlink1000OduAirPerf,,,,,, +.1.3.6.1.4.1.4458.1000.1.5.9.1,RADWIN-MIB-WINLINK1000::winlink1000OduAirRxPower,INTEGER,read-only,,mandatory,,Received Signal Strength in dBm. Relevant only for point to point systems. +.1.3.6.1.4.1.4458.1000.1.5.9.2,RADWIN-MIB-WINLINK1000::winlink1000OduAirTotalFrames,Counter32,read-only,,mandatory,,Total number of radio frames. +.1.3.6.1.4.1.4458.1000.1.5.9.3,RADWIN-MIB-WINLINK1000::winlink1000OduAirBadFrames,Counter32,read-only,,mandatory,,Total number of received radio frames with CRC error. The value is relevant only for point to point systems . +.1.3.6.1.4.1.4458.1000.1.5.9.4,RADWIN-MIB-WINLINK1000::winlink1000OduAirCurrentRate,INTEGER,read-only,,deprecated,,Deprecated parameter. Actual rate of the air interface in Mbps. For Channel Bandwidth of 20, 10, 5 MHz divide the value by 1, 2, 4 respectively. +.1.3.6.1.4.1.4458.1000.1.5.9.5,RADWIN-MIB-WINLINK1000::winlink1000OduAirCurrentRateIdx,INTEGER,read-only,,mandatory,,Index of current air rate. +.1.3.6.1.4.1.4458.1000.1.5.9.6,RADWIN-MIB-WINLINK1000::winlink1000OduAirChainsRxPower,OCTET,read-only,,mandatory,,Received Signal Strength of Cpe chains in dBm. Chain 1 RSS: (1 Byte) Chain 2 RSS: (1 Byte) Chain 3 RSS: (1 Byte) +.1.3.6.1.4.1.4458.1000.1.5.9.7,RADWIN-MIB-WINLINK1000::winlink1000OduAirCurrentRateCBW,INTEGER,read-only,,mandatory,,CBW of current air rate. +.1.3.6.1.4.1.4458.1000.1.5.9.8,RADWIN-MIB-WINLINK1000::winlink1000OduAirCurrentRateGI,INTEGER,read-only,,mandatory,,GI of current air rate. +.1.3.6.1.4.1.4458.1000.1.5.10,RADWIN-MIB-WINLINK1000::winlink1000OduAirTxPower36,INTEGER,read-write,,deprecated,,Deprecated parameter. Actual behavior is read-only. +.1.3.6.1.4.1.4458.1000.1.5.11,RADWIN-MIB-WINLINK1000::winlink1000OduAirTxPower48,INTEGER,read-write,,deprecated,,Deprecated parameter. Actual behavior is read-only. +.1.3.6.1.4.1.4458.1000.1.5.12,RADWIN-MIB-WINLINK1000::winlink1000OduAirCurrentTxPower,INTEGER,read-only,,mandatory,,Current Transmit Power in dBm. This is a nominal value while the actual transmit power includes additional attenuation. +.1.3.6.1.4.1.4458.1000.1.5.13,RADWIN-MIB-WINLINK1000::winlink1000OduAirMinFrequency,INTEGER,read-only,,mandatory,,Minimum center frequency in MHz. +.1.3.6.1.4.1.4458.1000.1.5.14,RADWIN-MIB-WINLINK1000::winlink1000OduAirMaxFrequency,INTEGER,read-only,,mandatory,,Maximum center frequency in MHz. +.1.3.6.1.4.1.4458.1000.1.5.15,RADWIN-MIB-WINLINK1000::winlink1000OduAirFreqResolution,INTEGER,read-only,,mandatory,,Center Frequency resolution. Measured in MHz if value < 100, otherwise in KHz. +.1.3.6.1.4.1.4458.1000.1.5.16,RADWIN-MIB-WINLINK1000::winlink1000OduAirCurrentFreq,INTEGER,read-only,,mandatory,,Current Center Frequency. Measured in MHz if center frequency resolution value < 100, otherwise in KHz. +.1.3.6.1.4.1.4458.1000.1.5.17,RADWIN-MIB-WINLINK1000::winlink1000OduAirNumberOfChannels,INTEGER,read-only,,mandatory,,Number of channels that can be used. +.1.3.6.1.4.1.4458.1000.1.5.18,RADWIN-MIB-WINLINK1000::winlink1000OduAirChannelsTable,,not-accessible,,mandatory,,Table of channels used by automatic channels selection (ACS). +.1.3.6.1.4.1.4458.1000.1.5.18.1,RADWIN-MIB-WINLINK1000::winlink1000OduAirChannelsEntry,,not-accessible,winlink1000OduAirChannelsIndex,mandatory,,ACS channels table entry. +.1.3.6.1.4.1.4458.1000.1.5.18.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAirChannelsIndex,INTEGER,read-only,,mandatory,,Channel Index. +.1.3.6.1.4.1.4458.1000.1.5.18.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAirChannelsFrequency,INTEGER,read-only,,mandatory,,Channel frequency in MHz. +.1.3.6.1.4.1.4458.1000.1.5.18.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduAirChannelsOperState,INTEGER,read-write,,mandatory,,Channel state. Can be set by the user. Automatic Channel Selection uses channels that are AirChannelsOperState enabled and AirChannelsAvail enabled. A change is effective after link re-synchronization. Valid values: disabled (0), enabled (1). Rewriteable only in Point-To-Point products. +.1.3.6.1.4.1.4458.1000.1.5.18.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduAirChannelsAvail,INTEGER,read-only,,mandatory,,Channel state. Product specific and cannot be changed by the user. Automatic Channel Selection uses channels that are AirChannelsOperState enabled and AirChannelsAvail enabled. Valid values: disabled (0), enabled (1). +.1.3.6.1.4.1.4458.1000.1.5.18.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduAirChannelsDefaultFreq,INTEGER,read-only,,mandatory,,Default channel's availability for all CBWs. The valid values are: forbidden (0), available (1). +.1.3.6.1.4.1.4458.1000.1.5.19,RADWIN-MIB-WINLINK1000::winlink1000OduAirDfsState,INTEGER,read-only,,mandatory,,Radar detection state. Valid values: disabled (0), enabled (1). +.1.3.6.1.4.1.4458.1000.1.5.20,RADWIN-MIB-WINLINK1000::winlink1000OduAirAutoChannelSelectionState,INTEGER,read-only,,deprecated,,Deprecated parameter. Indicating Automatic Channel Selection availability at current channel bandwidth. Valid values: disabled (0), enabled (1). +.1.3.6.1.4.1.4458.1000.1.5.21,RADWIN-MIB-WINLINK1000::winlink1000OduAirEnableTxPower,INTEGER,read-only,,mandatory,enabled(1):disabled(2),Indicating Transmit power configuration enabled or disabled. +.1.3.6.1.4.1.4458.1000.1.5.22,RADWIN-MIB-WINLINK1000::winlink1000OduAirMinTxPower,INTEGER,read-only,,mandatory,,Minimum Transmit power in dBm. +.1.3.6.1.4.1.4458.1000.1.5.23,RADWIN-MIB-WINLINK1000::winlink1000OduAirMaxTxPowerTable,,not-accessible,,mandatory,,Table of Maximum transmit power per air rate, in dBm. +.1.3.6.1.4.1.4458.1000.1.5.23.1,RADWIN-MIB-WINLINK1000::winlink1000OduAirMaxTxPowerEntry,,not-accessible,winlink1000OduAirMaxTxPowerIndex,mandatory,,Maximum Transmit power table entry. +.1.3.6.1.4.1.4458.1000.1.5.23.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAirMaxTxPowerIndex,INTEGER,read-only,,mandatory,,Air interface rate index. +.1.3.6.1.4.1.4458.1000.1.5.23.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAirMaxTxPower,INTEGER,read-only,,mandatory,,Maximum Transmit power in dBm. +.1.3.6.1.4.1.4458.1000.1.5.24,RADWIN-MIB-WINLINK1000::winlink1000OduAirChannelBandwidth,INTEGER,read-write,,mandatory,,Channel bandwidth in KHz. A change is effective after reset. +.1.3.6.1.4.1.4458.1000.1.5.25,RADWIN-MIB-WINLINK1000::winlink1000OduAirChannelBWTable,,not-accessible,,mandatory,,Channel Bandwidths table. +.1.3.6.1.4.1.4458.1000.1.5.25.1,RADWIN-MIB-WINLINK1000::winlink1000OduAirChannelBWEntry,,not-accessible,winlink1000OduAirChannelBWIndex,mandatory,,Channel Bandwidth table entry. +.1.3.6.1.4.1.4458.1000.1.5.25.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAirChannelBWIndex,INTEGER,read-only,,mandatory,channelBW5MHz(1):channelBW10MHz(2):channelBW20MHz(3):channelBW40MHz(4):channelBW80MHz(5):channelBW7MHz(6):channelBW14MHz(7),Channel Bandwidth index. +.1.3.6.1.4.1.4458.1000.1.5.25.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAirChannelBWAvail,INTEGER,read-only,,mandatory,notSupported(1):supportedManual(2):supportedWithACS(3),Channel Bandwidth availability, product specific. Options are: Not supported, supported with manual channel selection, supported with Automatic Channel Selection. +.1.3.6.1.4.1.4458.1000.1.5.25.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduAirChannelsAdminState,OCTET,read-only,,mandatory,,Channels' availability per CBW. +.1.3.6.1.4.1.4458.1000.1.5.25.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduAirChannelBWHSSATDDConflictPerCBW,INTEGER,read-only,,mandatory,noConflict(1):conflictSingle(2):conflictDual(3),Indication for possible Link drop per CBW due to conflict between HSS and ATDD. +.1.3.6.1.4.1.4458.1000.1.5.25.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduAirChannelBWMinRatioForSupporting,INTEGER,read-only,,mandatory,,Minimal TX ratio that may be used by the HSM and still enable proper operation of the aforementioned CBW. +.1.3.6.1.4.1.4458.1000.1.5.25.1.6,RADWIN-MIB-WINLINK1000::winlink1000OduAirChannelBWMaxRatioForSupporting,INTEGER,read-only,,mandatory,,Maximal TX ratio that may be used by the HSM and still enable proper operation of the aforementioned CBW. +.1.3.6.1.4.1.4458.1000.1.5.26,RADWIN-MIB-WINLINK1000::winlink1000OduAirRFD,INTEGER,read-only,,mandatory,,Current radio frame duration in microseconds. +.1.3.6.1.4.1.4458.1000.1.5.27,RADWIN-MIB-WINLINK1000::winlink1000OduAirRatesTable,,not-accessible,,mandatory,,Air Rate indexes table for current channel bandwidth. +.1.3.6.1.4.1.4458.1000.1.5.27.1,RADWIN-MIB-WINLINK1000::winlink1000OduAirRatesEntry,,not-accessible,winlink1000OduAirRatesIndex,mandatory,,Air Rate indexes table entry. +.1.3.6.1.4.1.4458.1000.1.5.27.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAirRatesIndex,INTEGER,read-only,,mandatory,,Air Rate index. +.1.3.6.1.4.1.4458.1000.1.5.27.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAirRatesAvail,INTEGER,read-only,,mandatory,rateNotAvailable(1):rateAvailable(2),Air Rate availability, depending on air interface conditions. +.1.3.6.1.4.1.4458.1000.1.5.28,RADWIN-MIB-WINLINK1000::winlink1000OduAirDesiredRateIdx,INTEGER,read-write,,mandatory,,Required Air Rate index. 0 reserved for Adaptive Rate. A change is effective immediately after Set operation to the master side while the link is up. +.1.3.6.1.4.1.4458.1000.1.5.29,RADWIN-MIB-WINLINK1000::winlink1000OduAirLinkDistance,INTEGER,read-only,,mandatory,,Link distance in meters. A value of -1 indicates an illegal value and is also used when a link is not established. +.1.3.6.1.4.1.4458.1000.1.5.30,RADWIN-MIB-WINLINK1000::winlink1000OduAirLinkWorkingMode,INTEGER,read-only,,mandatory,unknown(1):normal(2):fullCompatibilityRemoteUpgradeAvailable(3):fullCompatibilityLocalUpgradeAvailable(4):restrictedCompatibilityRemoteUpgradeRecomended(5):restrictedCompatibilityLocalUpgradeRecomended(6):softwareUpgradeRemoteUpgradeRequired(7):softwareUpgradeLocalUpgradeRequired(8):versionsIncompatibilityRemoteUpgradeRequired(9):versionsIncompatibilityLocalUpgradeRequired(10),Link working mode as a result of comparing versions of both sides of the link. Possible modes are: Unknown - no link, Normal - versions on both sides are identical with full compatibility, with restricted compatibility, or versions on both sides are different with software upgrade or versions incompatibility. +.1.3.6.1.4.1.4458.1000.1.5.31,RADWIN-MIB-WINLINK1000::winlink1000OduAirMajorLinkIfVersion,INTEGER,read-only,,mandatory,,Major link interface version +.1.3.6.1.4.1.4458.1000.1.5.32,RADWIN-MIB-WINLINK1000::winlink1000OduAirMinorLinkIfVersion,INTEGER,read-only,,mandatory,,Minor link interface version +.1.3.6.1.4.1.4458.1000.1.5.40,RADWIN-MIB-WINLINK1000::winlink1000OduAirHss,,,,,, +.1.3.6.1.4.1.4458.1000.1.5.40.1,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssDesiredOpState,INTEGER,read-write,,mandatory,notSupported(1):independentUnit(2):hubSyncMaster(3):hubSyncClientContinueTx(4):hubSyncClientDisableTx(5):gpsSync(6):independentSyncUnit-ISU(7),Required Hub Site Synchronization operating state. For HssSyncUnits : For hssISU :[2,7] ,For hssGSU :[2,6] For HBS: [2,3,4,5] +.1.3.6.1.4.1.4458.1000.1.5.40.2,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssCurrentOpState,INTEGER,read-only,,mandatory,notSupported(1):independentUnit(2):hubSyncMaster(3):hubSyncClientContinueTx(4):hubSyncClientDisableTx(5):gpsSync(6):independentSyncUnit-ISU(7),Current Hub Site Synchronization operating state. +.1.3.6.1.4.1.4458.1000.1.5.40.3,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssSyncStatus,INTEGER,read-only,,mandatory,notApplicable(1):notSynchronized(2):synchronized(3),Hub Site Synchronization sync status. +.1.3.6.1.4.1.4458.1000.1.5.40.4,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssExtPulseStatus,INTEGER,read-only,,mandatory,notDetected(1):generating(2):generatingAndDetected(3):generatingAndImproperDetected(4):detected(5):improperDetected(6):multipleSourcesDetected(7),Hub Site Synchronization external pulse detection status. In GSS mode: if generating then 1PSP is auto generated by the GSS Unit. if generatingAndDetecting then 1PSP is generated by GPS satellites signal. +.1.3.6.1.4.1.4458.1000.1.5.40.5,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssExtPulseType,INTEGER,read-only,,mandatory,notApplicable(1):typeA(2):typeB(3):typeC(4):typeD(5):typeE(6):typeF(7),Hub Site Synchronization external pulse type. +.1.3.6.1.4.1.4458.1000.1.5.40.6,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssDesiredExtPulseType,INTEGER,read-write,,mandatory,notApplicable(1):typeA(2):typeB(3):typeC(4):typeD(5):typeE(6):typeF(7),Hub Site Synchronization required external pulse type. Valid values for read write: {typeA(2),typeB(3),typeC(4),typeD(5),typeE(6),typeF(7)}. Valid value for read only: {notApplicable(1)}. +.1.3.6.1.4.1.4458.1000.1.5.40.7,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssRfpTable,,not-accessible,,mandatory,,ODU Radio Frame Patterns (RFP) Table. +.1.3.6.1.4.1.4458.1000.1.5.40.7.1,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssRfpEntry,,not-accessible,winlink1000OduAirHssRfpIndex,mandatory,,ODU RFP Table entry. +.1.3.6.1.4.1.4458.1000.1.5.40.7.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssRfpIndex,INTEGER,read-only,,mandatory,,ODU RFP Table index. The index represent the Radio Frame Pattern: typeA(2), typeB(3), typeC(4), typeD(5),typeE(6),typeF(7). +.1.3.6.1.4.1.4458.1000.1.5.40.7.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssRfpEthChannelBW5MHz,INTEGER,read-only,,mandatory,bestFit(1):nonOptimal(2):notAvailable(3),Represents the compatibility of Ethernet service under Channel BW of 5MHz in the specific Radio Frame Pattern. +.1.3.6.1.4.1.4458.1000.1.5.40.7.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssRfpTdmChannelBW5MHz,INTEGER,read-only,,mandatory,bestFit(1):nonOptimal(2):notAvailable(3),Represents the compatibility of TDM service under Channel BW of 5MHz in the specific Radio Frame Pattern. +.1.3.6.1.4.1.4458.1000.1.5.40.7.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssRfpEthChannelBW10MHz,INTEGER,read-only,,mandatory,bestFit(1):nonOptimal(2):notAvailable(3),Represents the compatibility of Ethernet service under Channel BW of 10MHz in the specific Radio Frame Pattern. +.1.3.6.1.4.1.4458.1000.1.5.40.7.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssRfpTdmChannelBW10MHz,INTEGER,read-only,,mandatory,bestFit(1):nonOptimal(2):notAvailable(3),Represents the compatibility of TDM service under Channel BW of 10MHz in the specific Radio Frame Pattern. +.1.3.6.1.4.1.4458.1000.1.5.40.7.1.6,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssRfpEthChannelBW20MHz,INTEGER,read-only,,mandatory,bestFit(1):nonOptimal(2):notAvailable(3),Represents the compatibility of Ethernet service under Channel BW of 20MHz in the specific Radio Frame Pattern. +.1.3.6.1.4.1.4458.1000.1.5.40.7.1.7,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssRfpTdmChannelBW20MHz,INTEGER,read-only,,mandatory,bestFit(1):nonOptimal(2):notAvailable(3),Represents the compatibility of TDM service under Channel BW of 20MHz in the specific Radio Frame Pattern. +.1.3.6.1.4.1.4458.1000.1.5.40.7.1.8,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssRfpEthChannelBW40MHz,INTEGER,read-only,,mandatory,bestFit(1):nonOptimal(2):notAvailable(3),Represents the compatibility of Ethernet service under Channel BW of 40MHz in the specific Radio Frame Pattern. +.1.3.6.1.4.1.4458.1000.1.5.40.7.1.9,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssRfpTdmChannelBW40MHz,INTEGER,read-only,,mandatory,bestFit(1):nonOptimal(2):notAvailable(3),Represents the compatibility of TDM service under Channel BW of 40MHz in the specific Radio Frame Pattern. +.1.3.6.1.4.1.4458.1000.1.5.40.7.1.10,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssRfpEthChannelBW80MHz,INTEGER,read-only,,mandatory,bestFit(1):nonOptimal(2):notAvailable(3),Represents the compatibility of Ethernet service under Channel BW of 80MHz in the specific Radio Frame Pattern. +.1.3.6.1.4.1.4458.1000.1.5.40.7.1.11,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssRfpEthChannelBW7MHz,INTEGER,read-only,,mandatory,bestFit(1):nonOptimal(2):notAvailable(3),Represents the compatibility of Ethernet service under Channel BW of 7MHz in the specific Radio Frame Pattern. +.1.3.6.1.4.1.4458.1000.1.5.40.7.1.12,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssRfpEthChannelBW14MHz,INTEGER,read-only,,mandatory,bestFit(1):nonOptimal(2):notAvailable(3),Represents the compatibility of Ethernet service under Channel BW of 14MHz in the specific Radio Frame Pattern. +.1.3.6.1.4.1.4458.1000.1.5.40.8,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssRfpStr,OCTET,read-only,,mandatory,,Hub Site Synchronization supported patterns +.1.3.6.1.4.1.4458.1000.1.5.40.9,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssHsmID,INTEGER,read-only,,mandatory,,A unique ID which is common to the HSM and all its collocated ODUs +.1.3.6.1.4.1.4458.1000.1.5.40.10,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssTime,OCTET,read-only,,mandatory,,Hub Site Synchronization GPS time +.1.3.6.1.4.1.4458.1000.1.5.40.11,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssLatitude,OCTET,read-only,,mandatory,,Hub Site Synchronization GPS Latitude +.1.3.6.1.4.1.4458.1000.1.5.40.12,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssNSIndicator,OCTET,read-only,,mandatory,,Hub Site Synchronization GPS N/S Indicator +.1.3.6.1.4.1.4458.1000.1.5.40.13,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssLongitude,OCTET,read-only,,mandatory,,Hub Site Synchronization GPS Longitude +.1.3.6.1.4.1.4458.1000.1.5.40.14,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssEWIndicator,OCTET,read-only,,mandatory,,Hub Site Synchronization GPS E/W Indicator +.1.3.6.1.4.1.4458.1000.1.5.40.15,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssNumSatellites,OCTET,read-only,,mandatory,,Hub Site Synchronization GPS Number of satellites +.1.3.6.1.4.1.4458.1000.1.5.40.16,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssAltitude,OCTET,read-only,,mandatory,,Hub Site Synchronization GPS Altitude +.1.3.6.1.4.1.4458.1000.1.5.40.17,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssRfpPhase,INTEGER,read-write,,mandatory,rfpNormalPhase(1):rfpShiftedPhase(2),Hub Site Synchronization GPS RFP phase +.1.3.6.1.4.1.4458.1000.1.5.40.18,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssInterSiteSynchronizationMode,INTEGER,read-write,,mandatory,independent(1):synchronized(2),Inter-Site Synchronization Mode - independent / synchronized +.1.3.6.1.4.1.4458.1000.1.5.40.19,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssInterSiteSynchronizationAvailability,INTEGER,read-only,,mandatory,notAvailable(1):available(2),Inter-Site Synchronization Availability +.1.3.6.1.4.1.4458.1000.1.5.40.20,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssSatellitesSatSyncRequired,INTEGER,read-write,,mandatory,notRequired(1):required(2),Satellites Synchronization Is Required +.1.3.6.1.4.1.4458.1000.1.5.40.21,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssDomainID,OCTET,read-write,,mandatory,,EHSS domain. Indentify set of CUs with same HSS synchronization +.1.3.6.1.4.1.4458.1000.1.5.40.22,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssSupportedSynchronizationProtocol,INTEGER,read-only,,mandatory,serialOnly(1):ethOnly(2):both(3):ghssAndEth(4):ghssEthSerial(5):ghssOnly(6),Supported Synchronization Protocols +.1.3.6.1.4.1.4458.1000.1.5.40.23,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssDesiredSynchronizationProtocol,INTEGER,read-write,,mandatory,serialOnly(1):ethOnly(2):both(3):ghssOnly(4),Desired Synchronization Protocols +.1.3.6.1.4.1.4458.1000.1.5.40.24,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssDiscover,INTEGER,read-write,,mandatory,startAll(1):startAllMstr(2):startMyDmn(3):startMyMstr(4),Initiate Discovery process of ODUs on the network. +.1.3.6.1.4.1.4458.1000.1.5.40.25,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssNumberOfDiscoveredODUs,INTEGER,read-only,,mandatory,,Number OF Discovered ODUs in network. +.1.3.6.1.4.1.4458.1000.1.5.40.26,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssDiscoverTable,,not-accessible,,mandatory,,HSS Discover Table. +.1.3.6.1.4.1.4458.1000.1.5.40.26.1,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssDiscoverEntry,,not-accessible,winlink1000OduAirHssDiscoverIndex,mandatory,,ODU Discover Table entry. +.1.3.6.1.4.1.4458.1000.1.5.40.26.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssDiscoverIndex,INTEGER,read-only,,mandatory,,HSS Discover Table Index. +.1.3.6.1.4.1.4458.1000.1.5.40.26.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssDiscoverODUDescription,OCTET,read-only,,mandatory,,Hold ODU HSS status in compress format: Domain,IP,HSS Role,Hss support, Enabled HSS protocol,Sync Status, Location, IPv6. +.1.3.6.1.4.1.4458.1000.1.5.40.27,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssMasterSlaveCompatibility,INTEGER,read-only,,mandatory,compatible(1):notCompatible(2),EHSM version compatibility. Relevant to Ethernet HSS Clients only. +.1.3.6.1.4.1.4458.1000.1.5.40.28,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssNumberOfAssociatedCU,INTEGER,read-only,,mandatory,,Number of associated Ethernet HSS Clients. Relevant to Ethernet HSS Masters only +.1.3.6.1.4.1.4458.1000.1.5.40.29,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssAssociatedCUTable,,not-accessible,,mandatory,,Associated Ethernet HSS Clients Table. Releant for Ethernet HSS Masters only. +.1.3.6.1.4.1.4458.1000.1.5.40.29.1,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssAssociatedCUTableEntry,,not-accessible,winlink1000OduAirHssAssociatedCUIndex,mandatory,,Associated Ethernet HSS Clients Table Entry. Releant for Ethernet HSS Masters only. +.1.3.6.1.4.1.4458.1000.1.5.40.29.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssAssociatedCUIndex,INTEGER,read-only,,mandatory,,Associated Ethernet HSS Clients Table Index. Releant for Ethernet HSS Masters only. +.1.3.6.1.4.1.4458.1000.1.5.40.29.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssAssociatedCUDescription,OCTET,read-only,,mandatory,,Holds Associated Ethernet HSS Clients Description in compress format: IP,Delay,Compatibility,Ethernet Speed, Ethernet Rx rate, IPv6 +.1.3.6.1.4.1.4458.1000.1.5.40.30,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssSyncStatusEth,INTEGER,read-only,,mandatory,notApplicable(1):notSynchronized(2):goodSynchronizationLevel(3):mediumSynchronizationLevel(4):badSynchronizationLevel(5):startSynchronization(6),Ethernet HSS Client Synchronization Level +.1.3.6.1.4.1.4458.1000.1.5.40.31,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssEthVLANTag,INTEGER,read-write,,mandatory,,Ethernet HSS VLan Tag: The least significate decimal digit is the VLan Priority(0-6) and the rest of the digits represents VLan ID (2-4094) +.1.3.6.1.4.1.4458.1000.1.5.40.32,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssHSMIPAddress,IpAddress,read-only,,mandatory,,HSMs IP address. Relevant for HSC synchronized over Ethernet. +.1.3.6.1.4.1.4458.1000.1.5.40.33,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssDelayToHSM,INTEGER,read-only,,mandatory,,Delay in microseconds to HSM. Relevant for HSC synchronized over Ethernet. +.1.3.6.1.4.1.4458.1000.1.5.40.34,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssSyncAcquisitionSeconds,INTEGER,read-write,,mandatory,,Accumulated quantity of seconds in clock acquisition while connected to current HSM +.1.3.6.1.4.1.4458.1000.1.5.40.35,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssHSMIPv6Address,OCTET,read-only,,mandatory,,HSMs IPv6 address. Relevant for HSC synchronized over Ethernet. +.1.3.6.1.4.1.4458.1000.1.5.40.36,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssTcMode,INTEGER,read-write,,mandatory,enable(1):disable(2),TC Mode +.1.3.6.1.4.1.4458.1000.1.5.40.37,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssGpsUncertainty,OCTET,read-write,,mandatory,,GPS Horizontal Location Uncertainty In Meters +.1.3.6.1.4.1.4458.1000.1.5.40.38,RADWIN-MIB-WINLINK1000::winlink1000OduAirHssDelayAdaptationEnable,INTEGER,read-only,,mandatory,enable(1):disable(2),Delay Adaptation Enable +.1.3.6.1.4.1.4458.1000.1.5.41,RADWIN-MIB-WINLINK1000::winlink1000OduAirLockRemote,INTEGER,read-write,,mandatory,unlock(1):lock(2),This parameter enables locking the link with a specific ODU. The following values can be set: Unlock (default) - The ODU is not locked on a specific remote ODU. Unlock can only be performed when the link is not connected. Lock - The ODU is locked on a specific remote ODU. Lock can only be performed when the link is active. +.1.3.6.1.4.1.4458.1000.1.5.42,RADWIN-MIB-WINLINK1000::winlink1000OduAirAntennaGain,INTEGER,read-write,,mandatory,,Current Antenna Gain in 0.1 dBi resolution. User defined value for external antenna. Legal range: MinAntennaGain100). If list is empty, no scan is done. +.1.3.6.1.4.1.4458.1000.1.5.78,RADWIN-MIB-WINLINK1000::winlink1000OduAirInterfaceUtilizationSupport,INTEGER,read-only,,mandatory,fullSupport(1):partialSupport(2),Support Air Interface Utilization: BTS: 1 = Full Support - all the CPEs support Air Interface Utilization. 2 = Partial Support - some of the CPEs not support Air Interface Utilization. CPE: 1 = Support Air Interface Utilization. This MIB doesn't exist if the device not support Air Interface Utilization. +.1.3.6.1.4.1.4458.1000.1.5.79,RADWIN-MIB-WINLINK1000::winlink1000OduAirCarrierTable,,not-accessible,,mandatory,,Carrier-specific attributes that are not band-specific +.1.3.6.1.4.1.4458.1000.1.5.79.1,RADWIN-MIB-WINLINK1000::winlink1000OduAirCarrierEntry,,not-accessible,winlink1000OduAirCarrierIndex,mandatory,,Carrier table entry. +.1.3.6.1.4.1.4458.1000.1.5.79.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAirCarrierIndex,INTEGER,read-only,,mandatory,carrier1(1):carrier2(2),Carrier index. +.1.3.6.1.4.1.4458.1000.1.5.79.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAirCarrierAntennaDescription,OCTET,read-only,,mandatory,,The is a description of the antenna connected to the ODU +.1.3.6.1.4.1.4458.1000.1.5.79.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduAirCarrierDesiredTxPower,INTEGER,read-write,,mandatory,,Required Transmit power in dBm . This is a nominal value while the actual transmit power includes additional attenuation. The min and max values are product specific. A change is effective immediately. +.1.3.6.1.4.1.4458.1000.1.5.79.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduAirCarrierResync,INTEGER,read-write,,mandatory,,Setting this parameter to 1 will cause the link to restart the synchronization process. +.1.3.6.1.4.1.4458.1000.1.5.79.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduAirCarrierCurrentTxPower,INTEGER,read-only,,mandatory,,Current Transmit Power in dBm. This is a nominal value while the actual transmit power includes additional attenuation. +.1.3.6.1.4.1.4458.1000.1.5.79.1.6,RADWIN-MIB-WINLINK1000::winlink1000OduAirCarrierCurrentFreq,INTEGER,read-only,,mandatory,,Current Center Frequency. Measured in MHz if center frequency resolution value < 100, otherwise in KHz. +.1.3.6.1.4.1.4458.1000.1.5.79.1.7,RADWIN-MIB-WINLINK1000::winlink1000OduAirCarrierChannelBandwidth,INTEGER,read-write,,mandatory,,Channel bandwidth in KHz. A change is effective after reset. +.1.3.6.1.4.1.4458.1000.1.5.79.1.8,RADWIN-MIB-WINLINK1000::winlink1000OduAirCarrierTotalTxPower,INTEGER,read-only,,mandatory,,Total Transmit Power in dBm. This is a nominal value While the actual transmit power includes additional attenuation. +.1.3.6.1.4.1.4458.1000.1.5.79.1.9,RADWIN-MIB-WINLINK1000::winlink1000OduAirCarrierSubBand,INTEGER,read-only,,mandatory,,Current Frequency Band Id Number. +.1.3.6.1.4.1.4458.1000.1.5.79.1.10,RADWIN-MIB-WINLINK1000::winlink1000OduAirCarrierComboSubBandTableIndex,INTEGER,read-only,,mandatory,,Index to the Combo table entry currently used +.1.3.6.1.4.1.4458.1000.1.5.79.1.11,RADWIN-MIB-WINLINK1000::winlink1000OduAirCarrierAntennaGain,INTEGER,read-write,,mandatory,,Current Antenna Gain in 0.1 dBi resolution. User defined value for external antenna. Legal range: MinAntennaGain|| +.1.3.6.1.4.1.4458.1000.1.5.79.1.18,RADWIN-MIB-WINLINK1000::winlink1000OduAirCarrierFrequencyHoppingSequence,INTEGER,read-write,,mandatory,,This parameter is applicable only in frequency hopping mode The sequencee number can be any number between 1 and the number of selected frequencies +.1.3.6.1.4.1.4458.1000.1.5.80,RADWIN-MIB-WINLINK1000::winlink1000OduAirAntennaHeight,INTEGER,read-write,,mandatory,,Antenna height above ground level in meter +.1.3.6.1.4.1.4458.1000.1.5.81,RADWIN-MIB-WINLINK1000::winlink1000OduAirAntennaHeightUncertainty,INTEGER,read-write,,mandatory,,Uncertainty in meters of antenna height +.1.3.6.1.4.1.4458.1000.1.5.82,RADWIN-MIB-WINLINK1000::winlink1000OduAirTvwsMinTvChannelIndex,INTEGER,read-only,,mandatory,,The current regulation first TV Channel Index +.1.3.6.1.4.1.4458.1000.1.5.83,RADWIN-MIB-WINLINK1000::winlink1000OduAirTvwsOpTable,OCTET,read-only,,mandatory,,List of EIRP limit per TV channel from Database +.1.3.6.1.4.1.4458.1000.1.5.84,RADWIN-MIB-WINLINK1000::winlink1000OduAirTvwsRulesetParams,OCTET,read-only,,mandatory,,Ruleset Parameters for TVWS Product +.1.3.6.1.4.1.4458.1000.1.5.85,RADWIN-MIB-WINLINK1000::winlink1000OduAirFrequrencyHoppingPassword,OCTET,read-write,,mandatory,,This parameter is applicable only in frequency hopping mode The password should x to y ascii characters Setting at the base station will apply to all connected subscriber units Setting to subscriber unit can be applied only when not connected. +.1.3.6.1.4.1.4458.1000.1.6,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMon,,,,,, +.1.3.6.1.4.1.4458.1000.1.6.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonCurrTable,,not-accessible,,mandatory,,This table defines/keeps the counters of the current 15 min interval. +.1.3.6.1.4.1.4458.1000.1.6.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonCurrEntry,,not-accessible,ifIndex,mandatory,,This is an entry in the Current Interval Table. +.1.3.6.1.4.1.4458.1000.1.6.1.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonCurrUAS,Gauge32,read-only,,mandatory,, The current number of Unavailable Seconds starting from the present 15 minutes period. +.1.3.6.1.4.1.4458.1000.1.6.1.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonCurrES,Gauge32,read-only,,mandatory,,Current number of Errored Seconds starting from the present 15 minutes period. +.1.3.6.1.4.1.4458.1000.1.6.1.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonCurrSES,Gauge32,read-only,,mandatory,,Current number of Severely Errored Seconds starting from the present 15 minutes period. +.1.3.6.1.4.1.4458.1000.1.6.1.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonCurrBBE,Gauge32,read-only,,mandatory,,Current number of Background Block Errors starting from the present 15 minutes period. +.1.3.6.1.4.1.4458.1000.1.6.1.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonCurrIntegrity,INTEGER,read-only,,mandatory,true(1):false(2),Indicates the integrity of the entry. +.1.3.6.1.4.1.4458.1000.1.6.1.1.6,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonCurrCompressed,OCTET,read-only,,mandatory,,Holds a compressed string of all data per interface. Compressed Air Interface Structure (size in brackets): UAS (4), ES (4), SES (4), BBE (4), Integrity (1), MinRSL (1), MaxRSL (1), RSLThresh1Exceeded (4), RSLThresh2Exceeded (4), MinTSL (1), MaxTSL (1), TSLThresh1Exceed (4), BBERThresh1Exceed (4), RxMBytes (4) TxMBytes (4), EthCapacityThreshUnder (4), HighTrafficThreshExceed (4) Compressed Etherent ODU interface (size in brackets): UAS (4), ES (4), SES (4), BBE (4), Integrity (1), RxMBytes (4), TxMBytes (4), EthCapacityThreshUnder (4), HighTrafficThreshExceed (4), ActiveSeconds (4) +.1.3.6.1.4.1.4458.1000.1.6.2,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonIntervalTable,,not-accessible,,mandatory,,This table defines/keeps the counters of the last day (in resolution of 15 min intervals). +.1.3.6.1.4.1.4458.1000.1.6.2.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonIntervalEntry,,not-accessible,ifIndex:winlink1000OduPerfMonIntervalIdx,mandatory,,This is an entry in the Interval Table. +.1.3.6.1.4.1.4458.1000.1.6.2.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonIntervalIdx,INTEGER,read-only,,mandatory,,This table is indexed per interval number. Each interval is of 15 minutes and the oldest is 96. +.1.3.6.1.4.1.4458.1000.1.6.2.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonIntervalUAS,Gauge32,read-only,,mandatory,, The current number of Unavailable Seconds per interval. +.1.3.6.1.4.1.4458.1000.1.6.2.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonIntervalES,Gauge32,read-only,,mandatory,,Current number of Errored Seconds per interval. +.1.3.6.1.4.1.4458.1000.1.6.2.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonIntervalSES,Gauge32,read-only,,mandatory,,Current number of Severely Errored Seconds per interval. +.1.3.6.1.4.1.4458.1000.1.6.2.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonIntervalBBE,Gauge32,read-only,,mandatory,,Current number of Background Block Errors per interval. +.1.3.6.1.4.1.4458.1000.1.6.2.1.6,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonIntervalIntegrity,INTEGER,read-only,,mandatory,true(1):false(2),Indicates the integrity of the entry per interval. +.1.3.6.1.4.1.4458.1000.1.6.2.1.7,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonIntervalCompressed,OCTET,read-only,,mandatory,,Holds a compressed string of all data per interface. Compressed Air Interface Structure (size in brackets): UAS (4), ES (4), SES (4), BBE (4), Integrity (1), MinRSL (1), MaxRSL (1), RSLThresh1Exceeded (4), RSLThresh2Exceeded (4), MinTSL (1), MaxTSL (1), TSLThresh1Exceed (4), BBERThresh1Exceed (4), RxMBytes (4) TxMBytes (4), EthCapacityThreshUnder (4), HighTrafficThreshExceed (4) Compressed Etherent ODU interface (size in brackets): UAS (4), ES (4), SES (4), BBE (4), Integrity (1), RxMBytes (4), TxMBytes (4), EthCapacityThreshUnder (4), HighTrafficThreshExceed (4), ActiveSeconds (1) +.1.3.6.1.4.1.4458.1000.1.6.3,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonDayTable,,not-accessible,,mandatory,,This table defines/keeps the counters of the last month (in resolution of days). +.1.3.6.1.4.1.4458.1000.1.6.3.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonDayEntry,,not-accessible,ifIndex:winlink1000OduPerfMonDayIdx,mandatory,,This is an entry in the Days Table. +.1.3.6.1.4.1.4458.1000.1.6.3.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonDayIdx,INTEGER,read-only,,mandatory,,This table is indexed per interval number. Each interval is of 24 hours and the oldest is 30. +.1.3.6.1.4.1.4458.1000.1.6.3.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonDayUAS,Gauge32,read-only,,mandatory,,The current number of Unavailable Seconds per interval of 24 hours. +.1.3.6.1.4.1.4458.1000.1.6.3.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonDayES,Gauge32,read-only,,mandatory,,Current number of Errored Seconds per interval of 24 hours. +.1.3.6.1.4.1.4458.1000.1.6.3.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonDaySES,Gauge32,read-only,,mandatory,,Current number of Severely Errored Seconds per interval of 24 hours. +.1.3.6.1.4.1.4458.1000.1.6.3.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonDayBBE,Gauge32,read-only,,mandatory,,Current number of Background Block Errors per interval of 24 hours. +.1.3.6.1.4.1.4458.1000.1.6.3.1.6,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonDayIntegrity,INTEGER,read-only,,mandatory,true(1):false(2),Indicates the integrity of the entry per interval of 24 hours. +.1.3.6.1.4.1.4458.1000.1.6.3.1.7,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonDayCompressed,OCTET,read-only,,mandatory,,Holds a compressed string of all data per interface. Compressed Air Interface Structure (size in brackets): UAS (4), ES (4), SES (4), BBE (4), Integrity (1), MinRSL (1), MaxRSL (1), RSLThresh1Exceeded (4), RSLThresh2Exceeded (4), MinTSL (1), MaxTSL (1), TSLThresh1Exceed (4), BBERThresh1Exceed (4), RxMBytes (4) TxMBytes (4), EthCapacityThreshUnder (4), HighTrafficThreshExceed (4) Compressed Etherent ODU interface (size in brackets): UAS (4), ES (4), SES (4), BBE (4), Integrity (1), RxMBytes (4), TxMBytes (4), EthCapacityThreshUnder (4), HighTrafficThreshExceed (4), ActiveSeconds (1) +.1.3.6.1.4.1.4458.1000.1.6.4,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirCurrTable,,not-accessible,,mandatory,,This table defines/keeps the air counters of the current 15 min interval. +.1.3.6.1.4.1.4458.1000.1.6.4.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirCurrEntry,,not-accessible,ifIndex,mandatory,,This is an entry in the Current Interval Table. +.1.3.6.1.4.1.4458.1000.1.6.4.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirCurrMinRSL,INTEGER,read-only,,mandatory,,Current Min Received Level Reference starting from the present 15 minutes period. +.1.3.6.1.4.1.4458.1000.1.6.4.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirCurrMaxRSL,INTEGER,read-only,,mandatory,,Current Max Received Level Reference starting from the present 15 minutes period. +.1.3.6.1.4.1.4458.1000.1.6.4.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirCurrRSLThresh1Exceed,Gauge32,read-only,,mandatory,,Number of seconds Receive Signal Level exceeded the RSL1 threshold in the last 15 minutes. +.1.3.6.1.4.1.4458.1000.1.6.4.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirCurrRSLThresh2Exceed,Gauge32,read-only,,mandatory,,Number of seconds Receive Signal Level exceeded the RSL2 threshold in the last 15 minutes. +.1.3.6.1.4.1.4458.1000.1.6.4.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirCurrMinTSL,INTEGER,read-only,,mandatory,,Current Min Transmit Signal Level starting from the present 15 minutes period. +.1.3.6.1.4.1.4458.1000.1.6.4.1.6,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirCurrMaxTSL,INTEGER,read-only,,mandatory,,Current Max Transmit Signal Level starting from the present 15 minutes period. +.1.3.6.1.4.1.4458.1000.1.6.4.1.7,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirCurrTSLThresh1Exceed,Gauge32,read-only,,mandatory,,Number of seconds Transmit Signal Level exceeded the TSL1 threshold in the last 15 minutes. +.1.3.6.1.4.1.4458.1000.1.6.4.1.8,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirCurrBBERThresh1Exceed,Gauge32,read-only,,mandatory,,Number of seconds Background Block Error Ratio exceeded the BBER1 threshold in the last 15 minutes. +.1.3.6.1.4.1.4458.1000.1.6.5,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirIntervalTable,,not-accessible,,mandatory,,This table defines/keeps the air counters of the last day (in resolution of 15 min intervals). +.1.3.6.1.4.1.4458.1000.1.6.5.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirIntervalEntry,,not-accessible,ifIndex:winlink1000OduPerfMonAirIntervalIdx,mandatory,,This is an entry in the Interval Table. +.1.3.6.1.4.1.4458.1000.1.6.5.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirIntervalIdx,INTEGER,read-only,,mandatory,,This table is indexed per interval number. Each interval is of 15 minutes and the oldest is 96. +.1.3.6.1.4.1.4458.1000.1.6.5.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirIntervalMinRSL,INTEGER,read-only,,mandatory,,Current Min Received Level Reference per interval. +.1.3.6.1.4.1.4458.1000.1.6.5.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirIntervalMaxRSL,INTEGER,read-only,,mandatory,,Current Max Received Level Reference per interval. +.1.3.6.1.4.1.4458.1000.1.6.5.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirIntervalRSLThresh1Exceed,Gauge32,read-only,,mandatory,,Number of seconds Receive Signal Level exceeded the RSL1 threshold per interval. +.1.3.6.1.4.1.4458.1000.1.6.5.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirIntervalRSLThresh2Exceed,Gauge32,read-only,,mandatory,,Number of seconds Receive Signal Level exceeded the RSL2 threshold ACCESS read-only per interval. +.1.3.6.1.4.1.4458.1000.1.6.5.1.6,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirIntervalMinTSL,INTEGER,read-only,,mandatory,,Current Min Transmit Signal Level per interval. +.1.3.6.1.4.1.4458.1000.1.6.5.1.7,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirIntervalMaxTSL,INTEGER,read-only,,mandatory,,Current Max Transmit Signal Level per interval. +.1.3.6.1.4.1.4458.1000.1.6.5.1.8,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirIntervalTSLThresh1Exceed,Gauge32,read-only,,mandatory,,Number of seconds Transmit Signal Level exceeded the TSL1 threshold per interval. +.1.3.6.1.4.1.4458.1000.1.6.5.1.9,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirIntervalBBERThresh1Exceed,Gauge32,read-only,,mandatory,,Number of seconds Background Block Error Ratio exceeded the BBER1 threshold per interval. +.1.3.6.1.4.1.4458.1000.1.6.6,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirDayTable,,not-accessible,,mandatory,,This table defines/keeps the air counters of the last month (in resolution of days). +.1.3.6.1.4.1.4458.1000.1.6.6.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirDayEntry,,not-accessible,ifIndex:winlink1000OduPerfMonAirDayIdx,mandatory,,This is an entry in the Days Table. +.1.3.6.1.4.1.4458.1000.1.6.6.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirDayIdx,INTEGER,read-only,,mandatory,,This table is indexed per Day number. Each Day is of 15 minutes and the oldest is 96. +.1.3.6.1.4.1.4458.1000.1.6.6.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirDayMinRSL,INTEGER,read-only,,mandatory,,Current Min Received Level Reference per Day. +.1.3.6.1.4.1.4458.1000.1.6.6.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirDayMaxRSL,INTEGER,read-only,,mandatory,,Current Max Received Level Reference per Day. +.1.3.6.1.4.1.4458.1000.1.6.6.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirDayRSLThresh1Exceed,Gauge32,read-only,,mandatory,,Number of seconds Receive Signal Level exceeded the RSL1 threshold per Day. +.1.3.6.1.4.1.4458.1000.1.6.6.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirDayRSLThresh2Exceed,Gauge32,read-only,,mandatory,,Number of seconds Receive Signal Level exceeded the RSL2 threshold per Day. +.1.3.6.1.4.1.4458.1000.1.6.6.1.6,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirDayMinTSL,INTEGER,read-only,,mandatory,,Current Min Transmit Signal Level per Day. +.1.3.6.1.4.1.4458.1000.1.6.6.1.7,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirDayMaxTSL,INTEGER,read-only,,mandatory,,Current Max Transmit Signal Level per Day. +.1.3.6.1.4.1.4458.1000.1.6.6.1.8,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirDayTSLThresh1Exceed,Gauge32,read-only,,mandatory,,Number of seconds Transmit Signal Level exceeded the TSL1 threshold per Day. +.1.3.6.1.4.1.4458.1000.1.6.6.1.9,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonAirDayBBERThresh1Exceed,Gauge32,read-only,,mandatory,,Number of seconds Background Block Error Ratio exceeded the BBER1 threshold per Day. +.1.3.6.1.4.1.4458.1000.1.6.7,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthCurrTable,,not-accessible,,mandatory,,This table defines/keeps the ethernet counters of the current 15 min interval. +.1.3.6.1.4.1.4458.1000.1.6.7.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthCurrEntry,,not-accessible,ifIndex,mandatory,,This is an entry in the Current Interval Table. +.1.3.6.1.4.1.4458.1000.1.6.7.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthCurrRxMBytes,Gauge32,read-only,,mandatory,,Current RX Mega Bytes starting from the present 15 minutes period. +.1.3.6.1.4.1.4458.1000.1.6.7.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthCurrTxMBytes,Gauge32,read-only,,mandatory,,Current Transmit Mega Bytes starting from the present 15 minutes period. +.1.3.6.1.4.1.4458.1000.1.6.7.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthCurrEthCapacityThreshUnder,Gauge32,read-only,,mandatory,,The number of times throughput was below threshold in the present 15 minutes period. Relevant for point to point systems. +.1.3.6.1.4.1.4458.1000.1.6.7.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthCurrHighTrafficThreshExceed,Gauge32,read-only,,mandatory,,The number of times actual traffic was above threshold in the present 15 minutes period. +.1.3.6.1.4.1.4458.1000.1.6.7.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthCurrActiveSeconds,Gauge32,read-only,,mandatory,,The number of seconds in which RPL Ethernet swervice was not blocked in the present 15 minutes period. +.1.3.6.1.4.1.4458.1000.1.6.8,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthIntervalTable,,not-accessible,,mandatory,,This table defines/keeps the ethernet counters of the last day (in resolution of 15 min intervals). +.1.3.6.1.4.1.4458.1000.1.6.8.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthIntervalEntry,,not-accessible,ifIndex:winlink1000OduPerfMonEthIntervalIdx,mandatory,,This is an entry in the Interval Table. +.1.3.6.1.4.1.4458.1000.1.6.8.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthIntervalIdx,INTEGER,read-only,,mandatory,,This table is indexed per interval number. Each interval is of 15 minutes and the oldest is 96. +.1.3.6.1.4.1.4458.1000.1.6.8.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthIntervalRxMBytes,Gauge32,read-only,,mandatory,,Current RX Mega Bytes per interval. +.1.3.6.1.4.1.4458.1000.1.6.8.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthIntervalTxMBytes,Gauge32,read-only,,mandatory,,Current Transmit Mega Bytes per interval. +.1.3.6.1.4.1.4458.1000.1.6.8.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthIntervalEthCapacityThreshUnder,Gauge32,read-only,,mandatory,,The number of times throughput was below threshold in the each interval. Relevant for point to point systems. +.1.3.6.1.4.1.4458.1000.1.6.8.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthIntervalHighTrafficThreshExceed,Gauge32,read-only,,mandatory,,The number of times actual traffic was above threshold in the each interval. +.1.3.6.1.4.1.4458.1000.1.6.8.1.6,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthIntervalActiveSeconds,Gauge32,read-only,,mandatory,,The number of seconds in which RPL Ethernet service was not blocked in the each interval. +.1.3.6.1.4.1.4458.1000.1.6.9,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthDayTable,,not-accessible,,mandatory,,This table defines/keeps the ethernet counters of the last month (in resolution of days). +.1.3.6.1.4.1.4458.1000.1.6.9.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthDayEntry,,not-accessible,ifIndex:winlink1000OduPerfMonEthDayIdx,mandatory,,This is an entry in the Days Table. +.1.3.6.1.4.1.4458.1000.1.6.9.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthDayIdx,INTEGER,read-only,,mandatory,,This table is indexed per Day number. Each interval is of 15 minutes and the oldest is 96. +.1.3.6.1.4.1.4458.1000.1.6.9.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthDayRxMBytes,Gauge32,read-only,,mandatory,,Current RX Mega Bytes per day. +.1.3.6.1.4.1.4458.1000.1.6.9.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthDayTxMBytes,Gauge32,read-only,,mandatory,,Current Transmit Mega Bytes per day. +.1.3.6.1.4.1.4458.1000.1.6.9.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthDayEthCapacityThreshUnder,Gauge32,read-only,,mandatory,,The number of times throughput was below threshold each day. Relevant for point to point systems. +.1.3.6.1.4.1.4458.1000.1.6.9.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthDayHighTrafficThreshExceed,Gauge32,read-only,,mandatory,,The number of times actual traffic was above threshold each day. +.1.3.6.1.4.1.4458.1000.1.6.9.1.6,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthDayActiveSeconds,Gauge32,read-only,,mandatory,,The number of seconds in which RPL Ethernet service was not blocked each day. +.1.3.6.1.4.1.4458.1000.1.6.10,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonTdmCurrTable,,not-accessible,,mandatory,,This table defines/keeps the TDM counters of the current 15 min interval. +.1.3.6.1.4.1.4458.1000.1.6.10.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonTdmCurrEntry,,not-accessible,ifIndex,mandatory,,This is an entry in the Current Interval Table. +.1.3.6.1.4.1.4458.1000.1.6.10.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonTdmCurrActiveSeconds,Gauge32,read-only,,mandatory,,Parameter indicating whether the TDM service was active. Under TDM backup link, the parameter indicates whether the backup link was active. +.1.3.6.1.4.1.4458.1000.1.6.11,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonTdmIntervalTable,,not-accessible,,mandatory,,This table defines/keeps the TDM counters of the last day (in resolution of 15 min intervals). +.1.3.6.1.4.1.4458.1000.1.6.11.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonTdmIntervalEntry,,not-accessible,ifIndex:winlink1000OduPerfMonTdmIntervalIdx,mandatory,,This is an entry in the Interval Table. +.1.3.6.1.4.1.4458.1000.1.6.11.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonTdmIntervalIdx,INTEGER,read-only,,mandatory,,This table is indexed per interval number. Each interval is of 15 minutes and the oldest is 96. +.1.3.6.1.4.1.4458.1000.1.6.11.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonTdmIntervalActiveSeconds,Gauge32,read-only,,mandatory,,Parameter indicating whether the TDM service was active. Under TDM backup link, the parameter indicates whether the backup link was active. +.1.3.6.1.4.1.4458.1000.1.6.12,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonTdmDayTable,,not-accessible,,mandatory,,This table defines/keeps the TDM counters of the last month (in resolution of days). +.1.3.6.1.4.1.4458.1000.1.6.12.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonTdmDayEntry,,not-accessible,ifIndex:winlink1000OduPerfMonTdmDayIdx,mandatory,,This is an entry in the Days Table. +.1.3.6.1.4.1.4458.1000.1.6.12.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonTdmDayIdx,INTEGER,read-only,,mandatory,,This table is indexed per Day number. Each interval is of 15 minutes and the oldest is 96. +.1.3.6.1.4.1.4458.1000.1.6.12.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonTdmDayActiveSeconds,Gauge32,read-only,,mandatory,,Parameter indicating whether the TDM service was active. Under TDM backup link, the parameter indicates whether the backup link was active. +.1.3.6.1.4.1.4458.1000.1.6.20,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonTxThresh1,INTEGER,read-write,,mandatory,,When the Transmit power exceeds this threshold, a performance monitoring TSL1 counter is incremented. +.1.3.6.1.4.1.4458.1000.1.6.21,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonRxThresh1,INTEGER,read-write,,mandatory,,When the RX power exceeds this threshold, a performance monitoring RSL1 counter is incremented. +.1.3.6.1.4.1.4458.1000.1.6.22,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonRxThresh2,INTEGER,read-write,,mandatory,,When the RX power exceeds this threshold, a performance monitoring RSL2 counter is incremented. +.1.3.6.1.4.1.4458.1000.1.6.23,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonBBERThresh1,INTEGER,read-write,,mandatory,,When the BBER exceeds this threshold, a performance monitoring BBER counter is incremented. The units are 1/10 of a percent. +.1.3.6.1.4.1.4458.1000.1.6.24,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonEthCapacityThreshKbps,INTEGER,read-write,,mandatory,,When the current throughput is below this threshold, the corresponding counter is incremented +.1.3.6.1.4.1.4458.1000.1.6.25,RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonHighTrafficThreshKbps,INTEGER,read-write,,mandatory,,When the current traffic is above this threshold, then corresponding counter is incremented. +.1.3.6.1.4.1.4458.1000.1.7,RADWIN-MIB-WINLINK1000::winlink1000OduAgent,,,,,, +.1.3.6.1.4.1.4458.1000.1.7.1,RADWIN-MIB-WINLINK1000::winlink1000OduAgnGeneral,,,,,, +.1.3.6.1.4.1.4458.1000.1.7.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAgnGenAddTrapExt,INTEGER,read-write,,mandatory,no(1):yes(2),If 'yes' is chosen, the ifIndex, Unit, Severity, Time_T and Alarm Id from the winlink1000OduAgnCurrAlarmTable will be bind to the end of each private trap. +.1.3.6.1.4.1.4458.1000.1.7.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAgnGenSetMode,INTEGER,read-write,,mandatory,enabled(1):disabledSWU(2):disabledSpectrumAnalysis(3):disabledBeforeResetAfterSWU(4):disabledUpdateConfigurationFiles(5):disabledSWK(6),This parameter is reserved to the element manager provided with the product. +.1.3.6.1.4.1.4458.1000.1.7.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduAgnGenLocalConnectionMode,INTEGER,read-write,,mandatory,readWrite(1):readOnly(2),Local Connection (Broadcast) Configuration Mode. Options are: 1 - SNMP Read-Write, 2 - SNMP Read-Only. +.1.3.6.1.4.1.4458.1000.1.7.2,RADWIN-MIB-WINLINK1000::winlink1000OduAgnNTPCfg,,,,,, +.1.3.6.1.4.1.4458.1000.1.7.2.1,RADWIN-MIB-WINLINK1000::winlink1000OduAgnNTPCfgTimeServerIP,IpAddress,read-write,,mandatory,,IP address of the server from which the current time is loaded. +.1.3.6.1.4.1.4458.1000.1.7.2.2,RADWIN-MIB-WINLINK1000::winlink1000OduAgnNTPCfgTimeOffsetFromUTC,INTEGER,read-write,,mandatory,,Offset from Coordinated Universal Time (minutes). Possible values: -1440..1440. +.1.3.6.1.4.1.4458.1000.1.7.2.3,RADWIN-MIB-WINLINK1000::winlink1000OduAgnRealTimeAndDate,OCTET,read-write,,mandatory,,This parameter specifies the real time and date Format 'YYYY-MM-DD,HH:MM:SS' (Hexadecimal). A date-time specification: field octets contents range ----- ------ -------- ----- 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 07 c8 05 1a 0d 1e 0f 00 ( 1992 -5 -26,13:30:15 ) +.1.3.6.1.4.1.4458.1000.1.7.2.4,RADWIN-MIB-WINLINK1000::winlink1000OduAdmNTPCfgTimeServerIPv6,OCTET,read-write,,mandatory,,IPv6 address of the server from which the current time is loaded. +.1.3.6.1.4.1.4458.1000.1.7.3,RADWIN-MIB-WINLINK1000::winlink1000OduAgnCurrAlarm,,,,,, +.1.3.6.1.4.1.4458.1000.1.7.3.1,RADWIN-MIB-WINLINK1000::winlink1000OduAgnCurrAlarmLastChange,INTEGER,read-only,,mandatory,,This counter is initialized to 0 after a device reset and is incremented upon each change in the winlink1000OduAgnCurrAlarmTable (either an addition or removal of an entry). +.1.3.6.1.4.1.4458.1000.1.7.3.2,RADWIN-MIB-WINLINK1000::winlink1000OduAgnCurrAlarmTable,,not-accessible,,mandatory,,This table includes the currently active alarms. When a RAISED trap is sent, an alarm entry is added to the table. When a CLEAR trap is sent, the entry is removed. +.1.3.6.1.4.1.4458.1000.1.7.3.2.1,RADWIN-MIB-WINLINK1000::winlink1000OduAgnCurrAlarmEntry,,not-accessible,winlink1000OduAgnCurrAlarmCounter,mandatory,,Entry containing the details of a currently RAISED trap. +.1.3.6.1.4.1.4458.1000.1.7.3.2.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAgnCurrAlarmCounter,INTEGER,read-only,,mandatory,,A running counter of active alarms. The counter is incremented for every new RAISED trap. It is cleared after a device reset. +.1.3.6.1.4.1.4458.1000.1.7.3.2.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAgnCurrAlarmSeverity,INTEGER,read-only,,mandatory,event(1):normal(2):warning(4):minor(8):major(16):critical(32),Current Alarm severity. +.1.3.6.1.4.1.4458.1000.1.7.3.2.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduAgnCurrAlarmId,INTEGER,read-only,,mandatory,,Unique Alarm Identifier (combines alarm type and interface). The same AlarmId is used for RAISED and CLEARED alarms. +.1.3.6.1.4.1.4458.1000.1.7.3.2.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduAgnCurrAlarmIfIndex,INTEGER,read-only,,mandatory,,Interface Index where the alarm occurred. Alarms that are not associated with a specific interface will have the following value: 65535. +.1.3.6.1.4.1.4458.1000.1.7.3.2.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduAgnCurrAlarmUnit,INTEGER,read-only,,mandatory,idu(1):odu(2),Unit associated with the alarm. +.1.3.6.1.4.1.4458.1000.1.7.3.2.1.6,RADWIN-MIB-WINLINK1000::winlink1000OduAgnCurrAlarmTrapID,INTEGER,read-only,,mandatory,,ID of the raised trap that was sent when this alarm was raised. +.1.3.6.1.4.1.4458.1000.1.7.3.2.1.7,RADWIN-MIB-WINLINK1000::winlink1000OduAgnCurrAlarmTimeT,INTEGER,read-only,,mandatory,,Timestamp of this alarm. This number is in seconds from Midnight January 1st, 1970. +.1.3.6.1.4.1.4458.1000.1.7.3.2.1.8,RADWIN-MIB-WINLINK1000::winlink1000OduAgnCurrAlarmText,OCTET,read-only,,mandatory,,Alarm display text (same as the text in the sent trap). +.1.3.6.1.4.1.4458.1000.1.7.4,RADWIN-MIB-WINLINK1000::winlink1000OduAgnLastEvents,,,,,, +.1.3.6.1.4.1.4458.1000.1.7.4.1,RADWIN-MIB-WINLINK1000::winlink1000OduAgnLastEventsNumber,INTEGER,read-only,,mandatory,,This counter indicates the size of the winlink1000OduAgnLastEventsTable +.1.3.6.1.4.1.4458.1000.1.7.4.2,RADWIN-MIB-WINLINK1000::winlink1000OduAgnLastEventsTable,,not-accessible,,mandatory,,This table includes the last events. When a trap is sent, an event entry is added to the table. +.1.3.6.1.4.1.4458.1000.1.7.4.2.1,RADWIN-MIB-WINLINK1000::winlink1000OduAgnLastEventsEntry,,not-accessible,winlink1000OduAgnLastEventsIndex,mandatory,,Entry containing the details of last traps. +.1.3.6.1.4.1.4458.1000.1.7.4.2.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAgnLastEventsIndex,INTEGER,read-only,,mandatory,,The index of the table +.1.3.6.1.4.1.4458.1000.1.7.4.2.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAgnLastEventsSeverity,INTEGER,read-only,,mandatory,event(1):normal(2):warning(4):minor(8):major(16):critical(32),Current Trap severity. +.1.3.6.1.4.1.4458.1000.1.7.4.2.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduAgnLastEventsIfIndex,INTEGER,read-only,,mandatory,,Interface Index where the event occurred. Traps that are not associated with a specific interface will have the following value: 65535. +.1.3.6.1.4.1.4458.1000.1.7.4.2.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduAgnLastEventsTimeT,INTEGER,read-only,,mandatory,,Timestamp of this trap. This number is in seconds from Midnight January 1st, 1970. +.1.3.6.1.4.1.4458.1000.1.7.4.2.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduAgnLastEventsText,OCTET,read-only,,mandatory,,Trap display text (same as the text in the sent trap). +.1.3.6.1.4.1.4458.1000.1.7.4.2.1.6,RADWIN-MIB-WINLINK1000::winlink1000OduAgnLastEventsUnit,INTEGER,read-only,,mandatory,idu(1):odu(2):carrier1(3):carrier2(4):undefined(65535),Unit associated with the Trap +.1.3.6.1.4.1.4458.1000.1.7.5,RADWIN-MIB-WINLINK1000::winlink1000OduAgnUsersTable,,not-accessible,,mandatory,,SNMP users table. Each user is defined by name, password and profile. +.1.3.6.1.4.1.4458.1000.1.7.5.1,RADWIN-MIB-WINLINK1000::winlink1000OduAgnUsersEntry,,not-accessible,winlink1000OduAgnUsersIndex,mandatory,,SNMP users table entry. +.1.3.6.1.4.1.4458.1000.1.7.5.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAgnUsersIndex,INTEGER,read-only,,mandatory,,SNMP users table index. +.1.3.6.1.4.1.4458.1000.1.7.5.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAgnUsersUserName,OCTET,read-write,,mandatory,,SNMP users user names. +.1.3.6.1.4.1.4458.1000.1.7.5.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduAgnUsersPassword,OCTET,read-write,,mandatory,,SNMP users passwords. +.1.3.6.1.4.1.4458.1000.1.7.5.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduAgnUsersProfile,INTEGER,read-write,,mandatory,disabled(1):observer(2):admin(3):installer(4):operator(5),SNMP users profile (1=Disabled, 2=Observer, 3=Admin, 4=Installer, 5=Operator). +.1.3.6.1.4.1.4458.1000.1.7.5.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduAgnUsersLastAccessTime,INTEGER,read-only,,mandatory,,SNMP users last access time. +.1.3.6.1.4.1.4458.1000.1.7.6,RADWIN-MIB-WINLINK1000::winlink1000OduAgnSNMPV3AuthenticationMode,INTEGER,read-write,,mandatory,md5(1):sha1(2),SNMP V3 Authentication mode: 1-MD5(default), 2-SHA1. +.1.3.6.1.4.1.4458.1000.2,RADWIN-MIB-WINLINK1000::winlink1000Idu,,,,,, +.1.3.6.1.4.1.4458.1000.2.1,RADWIN-MIB-WINLINK1000::winlink1000IduAdmin,,,,,, +.1.3.6.1.4.1.4458.1000.2.1.1,RADWIN-MIB-WINLINK1000::winlink1000IduAdmProductType,OCTET,read-only,,mandatory,,IDU configuration description. +.1.3.6.1.4.1.4458.1000.2.1.2,RADWIN-MIB-WINLINK1000::winlink1000IduAdmHwRev,OCTET,read-only,,mandatory,,IDU Hardware Revision. +.1.3.6.1.4.1.4458.1000.2.1.3,RADWIN-MIB-WINLINK1000::winlink1000IduAdmSwRev,OCTET,read-only,,mandatory,,IDU Software Revision. +.1.3.6.1.4.1.4458.1000.2.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduAdmNumOfExternalAlarmIn,INTEGER,read-only,,mandatory,,Indicates the number of currently available External Alarm Inputs. +.1.3.6.1.4.1.4458.1000.2.1.5,RADWIN-MIB-WINLINK1000::winlink1000OduAdmExternAlarmInTable,,not-accessible,,mandatory,,This is the External Alarm Inputs table. +.1.3.6.1.4.1.4458.1000.2.1.5.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdmExternAlarmInEntry,,not-accessible,winlink1000OduAdmExternAlarmInIndex,mandatory,,Entry containing the elements of a single External Alarm Input. +.1.3.6.1.4.1.4458.1000.2.1.5.1.1,RADWIN-MIB-WINLINK1000::winlink1000OduAdmExternAlarmInIndex,INTEGER,read-only,,mandatory,,This value indicates the index of the External Alarm Input entry. +.1.3.6.1.4.1.4458.1000.2.1.5.1.2,RADWIN-MIB-WINLINK1000::winlink1000OduAdmExternAlarmInText,OCTET,read-write,,mandatory,,This field describes the External Alarm Input. It is an optional string of no more than 64 characters, which will be used in the event being sent as a result of a change in the status of the External Alarm Input. DEFVAL { \Alarm Description\ } +.1.3.6.1.4.1.4458.1000.2.1.5.1.3,RADWIN-MIB-WINLINK1000::winlink1000OduAdmExternAlarmInAdminState,INTEGER,read-write,,mandatory,enabled(1):disabled(2),This value indicates if this External Alarm Input is enabled or disabled. +.1.3.6.1.4.1.4458.1000.2.1.5.1.4,RADWIN-MIB-WINLINK1000::winlink1000OduAdmExternAlarmInStatus,INTEGER,read-only,,mandatory,clear(1):alarm(2):unknown(3),This value indicates the current status of the External Alarm Input. +.1.3.6.1.4.1.4458.1000.2.1.6,RADWIN-MIB-WINLINK1000::winlink1000IduAdmSN,OCTET,read-only,,mandatory,,IDU Serial Number +.1.3.6.1.4.1.4458.1000.2.1.7,RADWIN-MIB-WINLINK1000::winlink1000IduAdmIduDetectionMode,INTEGER,read-write,,mandatory,mandatoryDisabled(1):mandatoryEnabled(2):userDisabled(3):userEnabled(4),The parameter defines whether to send Ethernet frames to detect an IDU. The valid writable values are: userDisabled (3), userEnabled (4). A change requires a reset and is effective after reset. +.1.3.6.1.4.1.4458.1000.2.1.8,RADWIN-MIB-WINLINK1000::winlink1000IduAdmMountedTrunks,INTEGER,read-only,,mandatory,,Number of mounted trunks in the IDU +.1.3.6.1.4.1.4458.1000.2.1.9,RADWIN-MIB-WINLINK1000::winlink1000IduAdmLicensedTrunks,INTEGER,read-only,,mandatory,,Number of Licensed Trunks in the IDU +.1.3.6.1.4.1.4458.1000.2.1.10,RADWIN-MIB-WINLINK1000::winlink1000IduAdmVlanSupported,INTEGER,read-only,,mandatory,notSupported(1):supported(2):supportedLimited(3),Identifies if the local IDU supports VLAN tag/untag +.1.3.6.1.4.1.4458.1000.2.1.11,RADWIN-MIB-WINLINK1000::winlink1000IduAdmVlanEgressMode,OCTET,read-write,,mandatory,,VLAN tag/untag egress values +.1.3.6.1.4.1.4458.1000.2.1.12,RADWIN-MIB-WINLINK1000::winlink1000IduAdmVlanIngressMode,OCTET,read-write,,mandatory,,VLAN tag/untag ingress values +.1.3.6.1.4.1.4458.1000.2.1.13,RADWIN-MIB-WINLINK1000::winlink1000IduAdmVlanDefaultPortVIDs,OCTET,read-write,,mandatory,,VLAN tag/untag default VLAN ids for each port - Right most digit is Vlan priority (0-6), other digits compose Vlan Id (1-4094) +.1.3.6.1.4.1.4458.1000.2.1.14,RADWIN-MIB-WINLINK1000::winlink1000IduAdmVlanLan1UntaggedVIDs,OCTET,read-write,,mandatory,,VLAN untagged VIDs for LAN1 port +.1.3.6.1.4.1.4458.1000.2.1.15,RADWIN-MIB-WINLINK1000::winlink1000IduAdmVlanLan2UntaggedVIDs,OCTET,read-write,,mandatory,,VLAN untagged VIDs for LAN2 port +.1.3.6.1.4.1.4458.1000.2.1.16,RADWIN-MIB-WINLINK1000::winlink1000IduAdmVlanSfpUntaggedVIDs,OCTET,read-write,,mandatory,,VLAN untagged VIDs for Sfp port +.1.3.6.1.4.1.4458.1000.2.1.17,RADWIN-MIB-WINLINK1000::winlink1000IduAdmVlanLan1FilteredVIDs,OCTET,read-write,,mandatory,,VLAN filtered VIDs for LAN1 port +.1.3.6.1.4.1.4458.1000.2.1.18,RADWIN-MIB-WINLINK1000::winlink1000IduAdmVlanLan2FilteredVIDs,OCTET,read-write,,mandatory,,VLAN filtered VIDs for LAN2 port +.1.3.6.1.4.1.4458.1000.2.1.19,RADWIN-MIB-WINLINK1000::winlink1000IduAdmVlanSfpFilteredVIDs,OCTET,read-write,,mandatory,,VLAN filtered VIDs for Sfp port +.1.3.6.1.4.1.4458.1000.2.1.20,RADWIN-MIB-WINLINK1000::winlink1000IduAdmPortsConnection,INTEGER,read-write,,mandatory,,IDU ports connection bitmap. bit 0 - LAN1-LAN2 bit 1 - SFP-LAN1 bit 2 - SFP-LAN2 bit values: 0 - ports are disconnected. 1 - ports are connected. +.1.3.6.1.4.1.4458.1000.2.1.21,RADWIN-MIB-WINLINK1000::winlink1000IduAdmVlanMode,INTEGER,read-write,,mandatory,normal(1):membership(2),Local IDU Vlan Mode. +.1.3.6.1.4.1.4458.1000.2.1.22,RADWIN-MIB-WINLINK1000::winlink1000IduAdmVlanMembershipVIDs,OCTET,read-write,,mandatory,,VLAN Membership VLAN IDs list. +.1.3.6.1.4.1.4458.1000.2.1.23,RADWIN-MIB-WINLINK1000::winlink1000IduAdmVlanMembershipPortsCode,OCTET,read-write,,mandatory,,VLAN Membership ports code. Each value represent the relation (bitmap) Between the suitable VID to the IDU ports. bit 0 - LAN1 bit 1 - LAN2 bit 2 - SFP bit value 0 - not member of appropriate VID bit value 1 - member of appropriate VID +.1.3.6.1.4.1.4458.1000.2.1.24,RADWIN-MIB-WINLINK1000::winlink1000IduAdmVlanMembershipUntaggedHandle,OCTET,read-write,,mandatory,,VLAN Membership Untagged frames handling. The 3 values representing LAN1, LAN2 and SFP accordingly. For each port, the optional values are: 1 - Discard 2 - Tag 3 - Leave Unmodified +.1.3.6.1.4.1.4458.1000.2.1.25,RADWIN-MIB-WINLINK1000::winlink1000IduAdmVlanMembershipTagUntagged,OCTET,read-write,,mandatory,,VLAN Membership Untagged frames tagging. The 3 values representing LAN1, LAN2 and SFP accordingly. The value on each port entry represent the tagging value which is built of: VLAN ID & VLAN Priority. +.1.3.6.1.4.1.4458.1000.2.2,RADWIN-MIB-WINLINK1000::winlink1000IduService,,,,,, +.1.3.6.1.4.1.4458.1000.2.2.2,RADWIN-MIB-WINLINK1000::winlink1000IduSrvDesiredTrunks,INTEGER,read-write,,mandatory,,Required trunks bitmap. Note that the number of possible trunks that can be configured may vary, based on the IDU hardware configuration, the selected air interface rate and the range of the installation. The provided Manager application enables the user to select only available configurations. A change is effective immediately if applied to a master unit and the link is in service mode. +.1.3.6.1.4.1.4458.1000.2.2.4,RADWIN-MIB-WINLINK1000::winlink1000IduSrvServices,OBJECT,read-only,,mandatory,,This parameter is reserved to the Manager application provided with the product. +.1.3.6.1.4.1.4458.1000.2.2.6,RADWIN-MIB-WINLINK1000::winlink1000IduSrvActiveTrunks,INTEGER,read-only,,mandatory,,A bitmap describing the currently open TDM trunks. +.1.3.6.1.4.1.4458.1000.2.2.8,RADWIN-MIB-WINLINK1000::winlink1000IduSrvAvailableTrunks,INTEGER,read-only,,mandatory,,A bitmap describing the number of TDM trunks that can be opened in the current configuration. The values take into account the IDU hardware configuration, the air rate and the installation range. +.1.3.6.1.4.1.4458.1000.2.2.10,RADWIN-MIB-WINLINK1000::winlink1000IduSrvPossibleServicesTable,,not-accessible,,mandatory,,IDU Possible Services table. +.1.3.6.1.4.1.4458.1000.2.2.10.1,RADWIN-MIB-WINLINK1000::winlink1000IduSrvPossibleServicesEntry,,not-accessible,winlink1000IduSrvPossibleServicesIndex,mandatory,,IDU Services table entry. +.1.3.6.1.4.1.4458.1000.2.2.10.1.1,RADWIN-MIB-WINLINK1000::winlink1000IduSrvPossibleServicesIndex,INTEGER,read-only,,mandatory,,Table index, Rate index of the air interface. +.1.3.6.1.4.1.4458.1000.2.2.10.1.2,RADWIN-MIB-WINLINK1000::winlink1000IduSrvPossibleTdmServices,INTEGER,read-only,,deprecated,,Deprecated parameter. A bitmap describing the TDM trunks that can be opened in the corresponding Air Rate. +.1.3.6.1.4.1.4458.1000.2.2.10.1.3,RADWIN-MIB-WINLINK1000::winlink1000IduSrvPossibleEthServices,INTEGER,read-only,,deprecated,,Deprecated parameter. This parameter describes if the Ethernet Service can be opened in the corresponding Air Rate. The valid values are: disabled (0), enabled (1). +.1.3.6.1.4.1.4458.1000.2.2.10.1.4,RADWIN-MIB-WINLINK1000::winlink1000IduSrvRemainingRate,INTEGER,read-only,,mandatory,,Current Ethernet bandwidth in bps per air rate. +.1.3.6.1.4.1.4458.1000.2.2.10.1.5,RADWIN-MIB-WINLINK1000::winlink1000IduSrvTrunkCost,INTEGER,read-only,,mandatory,,Cost of the TDM Service in bps. +.1.3.6.1.4.1.4458.1000.2.2.11,RADWIN-MIB-WINLINK1000::winlink1000IduSrvAvailServicesTable,,not-accessible,,mandatory,,ODU Possible TDM Services table. +.1.3.6.1.4.1.4458.1000.2.2.11.1,RADWIN-MIB-WINLINK1000::winlink1000IduSrvAvailServicesEntry,,not-accessible,winlink1000IduSrvAvailServicesIndex,mandatory,,ODU TDM Services table entry. +.1.3.6.1.4.1.4458.1000.2.2.11.1.1,RADWIN-MIB-WINLINK1000::winlink1000IduSrvAvailServicesIndex,INTEGER,read-only,,mandatory,,Table index. The index is the bit mask of the TDM service. +.1.3.6.1.4.1.4458.1000.2.2.11.1.2,RADWIN-MIB-WINLINK1000::winlink1000IduSrvAvailServicesState,INTEGER,read-only,,mandatory,unavailable(1):available(2),Represents the TDM service availability. +.1.3.6.1.4.1.4458.1000.2.2.11.1.3,RADWIN-MIB-WINLINK1000::winlink1000IduSrvAvailServicesMinRateIdx,INTEGER,read-only,,mandatory,,Minimum rate index of the air interface which make the service possible. +.1.3.6.1.4.1.4458.1000.2.2.11.1.4,RADWIN-MIB-WINLINK1000::winlink1000IduSrvAvailServicesMaxRateIdx,INTEGER,read-only,,mandatory,,Maximum rate index of the air interface which make the service possible. +.1.3.6.1.4.1.4458.1000.2.2.11.1.5,RADWIN-MIB-WINLINK1000::winlink1000IduSrvAvailServicesReason,INTEGER,read-only,,mandatory,notApplicable(1):insufficientThroughput(2):notSupportedIDUHw(3):inconsistentLinkParams(4):improperExtPulseType(5):incompatibleSWVersion(6):asymmetricTDD(7),Information about the TDM Service availability. - Not Applicable if the service is available. The reasons for TDM Service unavailability: - The available throughput isn't sufficient for Service demands; - The IDU HW doesn't support the service; - A Link Password mismatch was detected; - The external pulse type detected is improper for TDM services; - A Software versions mismatch was detected. - A-Symetric TDD Mode Is Obligated. +.1.3.6.1.4.1.4458.1000.2.2.12,RADWIN-MIB-WINLINK1000::winlink1000IduSrvEthActive,INTEGER,read-only,,mandatory,inactive(1):active(2),Represents the Ethernet service activation state. +.1.3.6.1.4.1.4458.1000.2.2.13,RADWIN-MIB-WINLINK1000::winlink1000IduSrvEthAvailable,INTEGER,read-only,,mandatory,unavailable(1):available(2),Represents the Ethernet service availability state. +.1.3.6.1.4.1.4458.1000.2.2.14,RADWIN-MIB-WINLINK1000::winlink1000IduSrvEthThroughput,Gauge32,read-only,,mandatory,,Current available Ethernet service throughput in bps. +.1.3.6.1.4.1.4458.1000.2.2.15,RADWIN-MIB-WINLINK1000::winlink1000IduSrvEthMaxInfoRate,INTEGER,read-write,,mandatory,,Holds the maximum bandwidth (kbps) to be allocated for Ethernet service. Value of zero means that Ethernet service works as best effort. The maximum value is product specific. Refer to the user manual. +.1.3.6.1.4.1.4458.1000.2.2.16,RADWIN-MIB-WINLINK1000::winlink1000IduSrvAvailableTrunksT1,INTEGER,read-only,,mandatory,,A bitmap describing the TDM trunks that can be opened under T1 configuration. The values take into account the IDU hardware configuration, the air rate and the installation range. +.1.3.6.1.4.1.4458.1000.2.3,RADWIN-MIB-WINLINK1000::winlink1000IduEthernet,,,,,, +.1.3.6.1.4.1.4458.1000.2.3.1,RADWIN-MIB-WINLINK1000::winlink1000IduEthernetIfTable,,not-accessible,,mandatory,,IDU Ethernet Interface table. +.1.3.6.1.4.1.4458.1000.2.3.1.1,RADWIN-MIB-WINLINK1000::winlink1000IduEthernetIfEntry,,not-accessible,winlink1000IduEthernetIfIndex,mandatory,,IDU Ethernet Interface table entry. +.1.3.6.1.4.1.4458.1000.2.3.1.1.1,RADWIN-MIB-WINLINK1000::winlink1000IduEthernetIfIndex,INTEGER,read-only,,mandatory,,If Index corresponding to this Interface. +.1.3.6.1.4.1.4458.1000.2.3.1.1.5,RADWIN-MIB-WINLINK1000::winlink1000IduEthernetIfAddress,OCTET,read-only,,mandatory,,IDU MAC address. +.1.3.6.1.4.1.4458.1000.2.3.3,RADWIN-MIB-WINLINK1000::winlink1000IduEthernetNumOfLanPorts,INTEGER,read-only,,mandatory,,Number of LAN interfaces in the IDU. +.1.3.6.1.4.1.4458.1000.2.3.4,RADWIN-MIB-WINLINK1000::winlink1000IduEthernetNumOfSfpPorts,INTEGER,read-only,,mandatory,,The number of SFP interfaces in the IDU. +.1.3.6.1.4.1.4458.1000.2.3.5,RADWIN-MIB-WINLINK1000::winlink1000IduEthernetSfpProperties,OCTET,read-only,,mandatory,,SFP venfor properties : Vendor Name, PN and Revision. +.1.3.6.1.4.1.4458.1000.2.3.6,RADWIN-MIB-WINLINK1000::winlink1000IduEthernetGbeSupported,INTEGER,read-only,,mandatory,notSupported(1):supported(2),Supported Giga bit Ethernet in IDU. +.1.3.6.1.4.1.4458.1000.2.3.7,RADWIN-MIB-WINLINK1000::winlink1000IduEthernetOduInErrors,Counter32,read-only,,mandatory,,The number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. +.1.3.6.1.4.1.4458.1000.2.4,RADWIN-MIB-WINLINK1000::winlink1000IduBridge,,,,,, +.1.3.6.1.4.1.4458.1000.2.4.4,RADWIN-MIB-WINLINK1000::winlink1000IduBridgeTp,,,,,, +.1.3.6.1.4.1.4458.1000.2.4.4.2,RADWIN-MIB-WINLINK1000::winlink1000IduBridgeTpAging,INTEGER,read-write,,mandatory,,Timeout in seconds for aging. Note that for this parameter to be effective, the ODU must be configured to HUB mode. A change is effective immediately. +.1.3.6.1.4.1.4458.1000.2.6,RADWIN-MIB-WINLINK1000::winlink1000IduTdm,,,,,, +.1.3.6.1.4.1.4458.1000.2.6.1,RADWIN-MIB-WINLINK1000::winlink1000IduTdmTxClock,,,,,, +.1.3.6.1.4.1.4458.1000.2.6.1.1,RADWIN-MIB-WINLINK1000::winlink1000IduTdmTxClockAvailStates,INTEGER,read-only,,mandatory,,Available states of the TDM Transmit Clock Control, each input status is represented by a bit. When the state is available, the bit value is 1. When the state is unavailable, the bit value is 0. The available states are: bit 2 = Transparent bit 3 = Local Loop Timed bit 4 = Remote Loop Timed bit 5 = Local Internal bit 6 = Remote Internal +.1.3.6.1.4.1.4458.1000.2.6.1.2,RADWIN-MIB-WINLINK1000::winlink1000IduTdmTxClockDesiredState,INTEGER,read-write,,mandatory,transparent(2):localLT(4):remoteLT(8):localInternal(16):remoteInternal(32):multipleClock(64),Required state of the TDM Transmit Clock Control. A change is effective after re-activation of the TDM service. +.1.3.6.1.4.1.4458.1000.2.6.1.3,RADWIN-MIB-WINLINK1000::winlink1000IduTdmTxClockActualState,INTEGER,read-only,,mandatory,notAvailable(1):transparent(2):localLT(4):remoteLT(8):localInternal(16):remoteInternal(32):multipleClock(64),Actual state of the TDM Transmit Clock Control. +.1.3.6.1.4.1.4458.1000.2.6.2,RADWIN-MIB-WINLINK1000::winlink1000IduTdmMasterClock,,,,,, +.1.3.6.1.4.1.4458.1000.2.6.2.1,RADWIN-MIB-WINLINK1000::winlink1000IduTdmMasterClockAvailOptions,INTEGER,read-only,,mandatory,,Available options of the TDM Master Clock Control, each input status is represented by a bit. When the option is available, the bit value is 1. When the option is unavailable, the bit value is 0. The available options are: bit 2 = Automatic bit 3 = Trunk #1 bit 4 = Trunk #2 bit 5 = Trunk #3 bit 6 = Trunk #4 When no options are available the returned value is: 1 +.1.3.6.1.4.1.4458.1000.2.6.2.2,RADWIN-MIB-WINLINK1000::winlink1000IduTdmMasterClockDesired,INTEGER,read-write,,mandatory,automatic(2):trunk1(4):trunk2(8):trunk3(16):trunk4(32):multipleClocks(64),Required TDM Master Clock. A change is effective after re-activation of the TDM service. +.1.3.6.1.4.1.4458.1000.2.6.2.3,RADWIN-MIB-WINLINK1000::winlink1000IduTdmMasterClockActual,INTEGER,read-only,,mandatory,notAvailable(1):trunk1(4):trunk2(8):trunk3(16):trunk4(32):multipleClocks(64),Actual Trunk used for TDM Master Clock. +.1.3.6.1.4.1.4458.1000.2.6.6,RADWIN-MIB-WINLINK1000::winlink1000IduTdmConfigTable,,not-accessible,,mandatory,,IDU TDM Links Configuration table. +.1.3.6.1.4.1.4458.1000.2.6.6.1,RADWIN-MIB-WINLINK1000::winlink1000IduTdmConfigEntry,,not-accessible,winlink1000IduTdmConfigIndex,mandatory,,IDU TDM Links Configuration table entry. +.1.3.6.1.4.1.4458.1000.2.6.6.1.1,RADWIN-MIB-WINLINK1000::winlink1000IduTdmConfigIndex,INTEGER,read-only,,mandatory,,Table index. +.1.3.6.1.4.1.4458.1000.2.6.6.1.2,RADWIN-MIB-WINLINK1000::winlink1000IduTdmIfIndex,INTEGER,read-only,,mandatory,,Link index in the interface table. +.1.3.6.1.4.1.4458.1000.2.6.6.1.6,RADWIN-MIB-WINLINK1000::winlink1000IduTdmLineCoding,INTEGER,read-write,,mandatory,b8zs(2):ami(5),This parameter applies to T1 trunks only. The parameter controls the line coding. Setting the value to each of the indices applies to all. A change is effective after the next open of the TDM service. +.1.3.6.1.4.1.4458.1000.2.6.6.1.9,RADWIN-MIB-WINLINK1000::winlink1000IduTdmLoopbackConfig,INTEGER,read-write,,mandatory,normal(1):lineLoopBack(3):revereseLineLoopBack(4),Loop back configuration table. Each of the trunks can be set Normal, Line loop back or Reverse line loop back. A change is effective immediately. +.1.3.6.1.4.1.4458.1000.2.6.6.1.10,RADWIN-MIB-WINLINK1000::winlink1000IduTdmLineStatus,INTEGER,read-only,,mandatory,normal(1):ais(8):los(64):loopback(128),Line status. +.1.3.6.1.4.1.4458.1000.2.6.7,RADWIN-MIB-WINLINK1000::winlink1000IduTdmCurrentTable,,not-accessible,,mandatory,,IDU TDM Links Statistics table. +.1.3.6.1.4.1.4458.1000.2.6.7.1,RADWIN-MIB-WINLINK1000::winlink1000IduTdmCurrentEntry,,not-accessible,winlink1000IduTdmCurrentIndex,mandatory,,IDU TDM Links Statistics table entry. +.1.3.6.1.4.1.4458.1000.2.6.7.1.1,RADWIN-MIB-WINLINK1000::winlink1000IduTdmCurrentIndex,INTEGER,read-only,,mandatory,,Table index (Same as winlink1000IduTdmLineIndex). +.1.3.6.1.4.1.4458.1000.2.6.7.1.101,RADWIN-MIB-WINLINK1000::winlink1000IduTdmCurrentBlocks,Counter32,read-only,,mandatory,,Number of correct blocks transmitted to the line. +.1.3.6.1.4.1.4458.1000.2.6.7.1.102,RADWIN-MIB-WINLINK1000::winlink1000IduTdmCurrentDrops,Counter32,read-only,,mandatory,,Number of error blocks transmitted to the line. +.1.3.6.1.4.1.4458.1000.2.6.7.1.103,RADWIN-MIB-WINLINK1000::winlink1000IduTdmCurrentTxClock,INTEGER,read-write,,mandatory,transparent(2):localLT(4):remoteLT(8):localInternal(16):remoteInternal(32),TDM Transmit Clock. A change is effective after re-activation of the TDM service. +.1.3.6.1.4.1.4458.1000.2.6.7.1.104,RADWIN-MIB-WINLINK1000::winlink1000IduTdmCurrentBlocksHigh,Counter32,read-only,,mandatory,,High part of the 64 bits counter Current Blocks +.1.3.6.1.4.1.4458.1000.2.6.8,RADWIN-MIB-WINLINK1000::winlink1000IduTdmRemoteQual,INTEGER,read-only,,mandatory,,Estimated average interval between error second events. The valid values are 1-2^31 where a value of -1 is used to indicate an undefined state. +.1.3.6.1.4.1.4458.1000.2.6.9,RADWIN-MIB-WINLINK1000::winlink1000IduTdmRemoteQualEval,INTEGER,read-only,,mandatory,,Estimated average interval between error second events during evaluation process. The valid values are 1-2^31 where a value of -1 is used to indicate an undefined state. +.1.3.6.1.4.1.4458.1000.2.6.10,RADWIN-MIB-WINLINK1000::winlink1000IduTdmSrvEval,INTEGER,read-write,,mandatory,,Evaluated TDM service bit mask. Setting this parameter to value that is bigger than the activated TDM service bit mask will execute the evaluation process for 30 seconds. Setting this parameter to 0 will stop the evaluation process immediately. +.1.3.6.1.4.1.4458.1000.2.6.11,RADWIN-MIB-WINLINK1000::winlink1000IduTdmBackupAvailableLinks,INTEGER,read-only,,mandatory,,Number of TDM backup trunks. +.1.3.6.1.4.1.4458.1000.2.6.12,RADWIN-MIB-WINLINK1000::winlink1000IduTdmBackupTable,,not-accessible,,mandatory,,IDU TDM Links Statistics table. +.1.3.6.1.4.1.4458.1000.2.6.12.1,RADWIN-MIB-WINLINK1000::winlink1000IduTdmBackupEntry,,not-accessible,winlink1000IduTdmBackupIndex,mandatory,,IDU TDM Links Statistics table entry. +.1.3.6.1.4.1.4458.1000.2.6.12.1.1,RADWIN-MIB-WINLINK1000::winlink1000IduTdmBackupIndex,INTEGER,read-only,,mandatory,,Table index. +.1.3.6.1.4.1.4458.1000.2.6.12.1.2,RADWIN-MIB-WINLINK1000::winlink1000IduTdmBackupMode,INTEGER,read-write,,mandatory,enableUseAirLinkAsBackupLink(1):enableUseExternalLinkAsBackupLink(2):disableUseExternalLinkAsMainLink(3):disableUseAirLinkAsMainLink(4),TDM backup mode: Enable or Disable, where the main link is the air link or the external link. Changes will be effective immediatly. +.1.3.6.1.4.1.4458.1000.2.6.12.1.3,RADWIN-MIB-WINLINK1000::winlink1000IduTdmBackupCurrentActiveLink,INTEGER,read-only,,mandatory,notAvailable(1):airLinkIsActive(2):externalLinkIsActive(3):noLinkIsActive(4),TDM backup current active link: N/A, air link is active or external link is active. +.1.3.6.1.4.1.4458.1000.2.6.13,RADWIN-MIB-WINLINK1000::winlink1000IduTdmJitterBufferSize,INTEGER,read-write,,mandatory,,TDM Jitter Buffer Size. The value must be between the minimum and the maximum TDM Jitter Buffer Size. The units are 0.1 x millisecond. +.1.3.6.1.4.1.4458.1000.2.6.14,RADWIN-MIB-WINLINK1000::winlink1000IduTdmJitterBufferDefaultSize,INTEGER,read-only,,mandatory,,TDM Jitter Buffer Default Size. The units are 0.1 x millisecond. +.1.3.6.1.4.1.4458.1000.2.6.15,RADWIN-MIB-WINLINK1000::winlink1000IduTdmJitterBufferMinSize,INTEGER,read-only,,mandatory,,TDM Jitter Buffer Minimum Size. The units are 0.1 x millisecond. +.1.3.6.1.4.1.4458.1000.2.6.16,RADWIN-MIB-WINLINK1000::winlink1000IduTdmJitterBufferMaxSize,INTEGER,read-only,,mandatory,,TDM Jitter Buffer Maximum Size. The units are 0.1 x millisecond. +.1.3.6.1.4.1.4458.1000.2.6.17,RADWIN-MIB-WINLINK1000::winlink1000IduTdmJitterBufferSizeEval,INTEGER,read-write,,mandatory,,TDM Jitter Buffer Size for evaluation. The value must be between the minimum and the maximum TDM Jitter Buffer Size. The units are 0.1 x millisecond. +.1.3.6.1.4.1.4458.1000.2.6.18,RADWIN-MIB-WINLINK1000::winlink1000IduTdmType,INTEGER,read-write,,mandatory,unDefined(1):e1(2):t1(3),TDM Type (The value undefined is read-only). +.1.3.6.1.4.1.4458.1000.2.6.19,RADWIN-MIB-WINLINK1000::winlink1000IduTdmTypeEval,INTEGER,read-write,,mandatory,unDefined(1):e1(2):t1(3),TDM Type for evaluation. +.1.3.6.1.4.1.4458.1000.2.6.20,RADWIN-MIB-WINLINK1000::winlink1000IduTdmLineStatusStr,OCTET,read-only,,mandatory,,Line status. +.1.3.6.1.4.1.4458.1000.2.6.21,RADWIN-MIB-WINLINK1000::winlink1000IduTdmHotStandbySupport,INTEGER,read-only,,mandatory,supported(1):notSupported(2),Indicates if Hot Standby is supported. +.1.3.6.1.4.1.4458.1000.2.6.22,RADWIN-MIB-WINLINK1000::winlink1000IduTdmDesiredHotStandbyMode,INTEGER,read-write,,mandatory,primary(1):secondary(2):disabled(3),Desired Hot Standby Mode. +.1.3.6.1.4.1.4458.1000.2.6.23,RADWIN-MIB-WINLINK1000::winlink1000IduTdmHotStandbyOperationStatus,INTEGER,read-only,,mandatory,active(1):notActive(2),The Link Actual Status. +.1.3.6.1.4.1.4458.1000.2.6.24,RADWIN-MIB-WINLINK1000::winlink1000IduTdmBackupLinkConfiguration,INTEGER,read-write,,mandatory,independent(1):repeaterEnd(2):lineEnd(3),The current configuration of the backup link. +.1.3.6.1.4.1.4458.1000.2.6.25,RADWIN-MIB-WINLINK1000::winlink1000IduTdmLineInterfaceConfiguration,INTEGER,read-write,,mandatory,balanced(1):unBalanced(2),TDM Line interface configuration. +.1.3.6.1.4.1.4458.1000.2.6.26,RADWIN-MIB-WINLINK1000::winlink1000IduTdmLineImpedanceConfiguration,INTEGER,read-write,,mandatory,standardT1(1):nonStandardT1(2),TDM line impedance configuration (standardT1 - 100Ohm, nonStandardT1 - 110Ohm) Applicable only for T1 TDM type. +.1.3.6.1.4.1.4458.1000.3,RADWIN-MIB-WINLINK1000::winlink1000Hbs,,,,,, +.1.3.6.1.4.1.4458.1000.3.1,RADWIN-MIB-WINLINK1000::winlink1000HbsAir,,,,,, +.1.3.6.1.4.1.4458.1000.3.1.1,RADWIN-MIB-WINLINK1000::winlink1000HbsAirState,INTEGER,read-only,,mandatory,init(1):bitFailed(2):inactive(3):spectrumMeasurement(4):scanning(5):cac(6):transceiving(7):standBy(8):rawAlignment(9):deviceNotReachable(10):tvwsDbDisabled(11):unauthorized(12):fail(13),Holds the state of the HBS. +.1.3.6.1.4.1.4458.1000.3.1.2,RADWIN-MIB-WINLINK1000::winlink1000HbsAirOpMode,INTEGER,read-write,,mandatory,inactive(1):active(2),Holds the operation mode of the HBS. +.1.3.6.1.4.1.4458.1000.3.1.3,RADWIN-MIB-WINLINK1000::winlink1000HbsAirAvailTimeSlots,INTEGER,read-only,,mandatory,,This parameter holds the number of available time slots (not in use) in the air interface. +.1.3.6.1.4.1.4458.1000.3.1.4,RADWIN-MIB-WINLINK1000::winlink1000HbsAirSectorCbwSupportedStr,OCTET,read-only,,mandatory,,Represents the channel bandwidth which is supported by the HBS and all connected HSUs. +.1.3.6.1.4.1.4458.1000.3.1.5,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCompressedMon,OCTET,read-only,,mandatory,,Holds HBS monitor data in compressed format: HBS Traffic Monitor In Bytes(4) Out Bytes(4) In Frames(4) Out Frames(4) HBS State (1) HBS Freq (4) Number of Links (2) EC Change Counter (4) Current Ratio (2) Total Air Frames (4) HBS Rx Rate in Kbps (4) HBS Tx Rate in Kbps (4) HBS Rx Rate in Fps (4) HBS Tx Rate in Fps (4) HBS Set Mode (1) HBS LAN 1 Rx Rate in Kbps (4) HBS LAN 1 Tx Rate in Kbps (4) HBS LAN 1 Rx Rate in Fps (4) HBS LAN 1 Tx Rate in Fps (4) HBS LAN 2 Rx Rate in Kbps (4) HBS LAN 2 Tx Rate in Kbps (4) HBS LAN 2 Rx Rate in Fps (4) HBS LAN 2 Tx Rate in Fps (4) SyncE Performance (1) Max Available BE HSUs (1). +.1.3.6.1.4.1.4458.1000.3.1.6,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConf,,,,,, +.1.3.6.1.4.1.4458.1000.3.1.6.1,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfChanges,OCTET,read-only,,mandatory,,16 characters that represent 16 HSUs. Each time a configuration is been changed, increment the relevant character. +.1.3.6.1.4.1.4458.1000.3.1.6.2,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfTable,,not-accessible,,mandatory,,Holds the table for all registered HSUs in the sector (31 entries). +.1.3.6.1.4.1.4458.1000.3.1.6.2.1,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfEntry,,not-accessible,winlink1000HbsAirConfIndex,mandatory,,HSUs configuration table entry. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.1,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfIndex,INTEGER,read-only,,mandatory,,HSUs configuration table index. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.2,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfUpMir,INTEGER,read-write,,mandatory,,Uplink MIR towards specific HSU in units of kbps. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.3,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfDownMir,INTEGER,read-write,,mandatory,,Downlink MIR towards specific HSU in units of kbps. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.4,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfHsuName,OCTET,read-write,,mandatory,,HSU name. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.5,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfHsuLocation,OCTET,read-write,,mandatory,,HSU location. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.6,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfDualAntTxMode,INTEGER,read-write,,mandatory,mimo(1):diversity(2):autoSelection(3),Transmission type when using Dual Antenna on both link's sides. spatial Multiplexing, Diversity (using a single spatial stream), and Auto Selection (OMS control). +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.7,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfNumOfTs,INTEGER,read-write,,mandatory,,Number of time slot which are allocated to specific HSU. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.8,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfGeoLocation,OCTET,read-write,,mandatory,,Geographic device location in format: latitude,longitude. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.9,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfHsuType,INTEGER,read-only,,mandatory,fixed(1):stationary(2):mobile(3):transport(4):mobileCoChannel(5):residential(6):nFixed(7):nResidential(8),HSU type (1 = Fixed, 2 = Stationary, 3 = Mobile, 4 = Transport, 5 = Mobile_co_channel, 6 = Residential, 7 = N_Fixed, 8 = N_Residential) +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.10,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfHsuLevel,INTEGER,read-write,,mandatory,,HSU level (1 .. 4) +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.11,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfDesiredRateIndex,INTEGER,read-write,,mandatory,,The rate index of both sides of the link to this HSU. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.12,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfMacAddress,OCTET,read-only,,mandatory,,HSU MAC Address. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.13,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfNumOfTsUp,INTEGER,read-write,,mandatory,,Number of UL time slot which are allocated to specific HSU. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.14,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfLanPortsConnection,INTEGER,read-write,,mandatory,enabled(1):disabled(2),Indicates if the connection between LAN 1 and LAN 2 is enabled. 1- Enabled , 2- Disabled. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.15,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfServiceCategory,INTEGER,read-only,,mandatory,,Indicates Service Category received from Radius server,values can be from 1 to 8 , 0 - undefined +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.16,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfAutoRealignmentConfiguration,OCTET,read-write,,mandatory,,Configuration Parameters For Auto Realignment. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.17,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfBeaconRssSyncLossThreshold,INTEGER,read-write,,mandatory,,RSS Threshold For Syncloss In Mobile Units +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.18,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfNumOfResourcesDL,INTEGER,read-write,,mandatory,,Number of DownLink Resources which are allocated to specific HSU. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.19,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfNumOfResourcesUL,INTEGER,read-write,,mandatory,,Number of UpLink Resources which are allocated to specific HSU. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.20,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfResourceType,INTEGER,read-write,,mandatory,assuredAllocation(1):bestEffort(2):undefined(3),Resources Allocation Type (AA or BE) to specific HSU. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.21,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfDelaySensitivity,INTEGER,read-write,,mandatory,sensitive(1):insensitive(2),Delay Sensitivity to specific HSU. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.22,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfLQDActivation,INTEGER,read-write,,mandatory,disabled(1):enabled(2),Link quality detection activation status +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.23,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfLQDBaselineDl,INTEGER,read-write,,mandatory,,Link quality detection downlink baseline +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.24,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfLQDBaselineUl,INTEGER,read-write,,mandatory,,Link quality detection uplink baseline +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.25,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfLQDCurrentQualityDl,INTEGER,read-only,,mandatory,,Link quality detection current downlink quality in kbps. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.26,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfLQDCurrentQualityUl,INTEGER,read-only,,mandatory,,Link quality detection current uplink quality in kbps. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.27,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfLQDAlarmThresholdDl,INTEGER,read-only,,mandatory,,Link quality detection downlink alarm threshold in kbps. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.28,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfLQDAlarmThresholdUl,INTEGER,read-only,,mandatory,,Link quality detection uplink alarm threshold in kbps. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.29,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfLQDAlarmClearThresholdDl,INTEGER,read-only,,mandatory,,Link quality detection downlink alarm clear threshold in kbps. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.30,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfLQDAlarmClearThresholdUl,INTEGER,read-only,,mandatory,,Link quality detection uplink alarm clear threshold in kbps. +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.31,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfIpAddress,OCTET,read-write,,mandatory,,HSU IP Address. Writable access only for manager +.1.3.6.1.4.1.4458.1000.3.1.6.2.1.32,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfCarrierId,INTEGER,read-only,,mandatory,,Carrier Id +.1.3.6.1.4.1.4458.1000.3.1.6.3,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfBeaconRssSyncLossInterval,INTEGER,read-write,,mandatory,,Interval over which the RSS value is below the threshold. +.1.3.6.1.4.1.4458.1000.3.1.6.4,RADWIN-MIB-WINLINK1000::winlink1000HbsAirConfBEPercentage,OCTET,read-write,,mandatory,,BE allocation percentage from the total resources (DownLink|UpLink|). +.1.3.6.1.4.1.4458.1000.3.1.7,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLink,,,,,, +.1.3.6.1.4.1.4458.1000.3.1.7.1,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkNumOfLinks,INTEGER,read-only,,mandatory,,Number of links in the links table. +.1.3.6.1.4.1.4458.1000.3.1.7.2,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkTable,,not-accessible,,mandatory,,Holds the table for all links in the sector. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkEntry,,not-accessible,winlink1000HbsAirLinkIndex,mandatory,,Link table entry. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.1,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkIndex,INTEGER,read-only,,mandatory,,HSUs configuration table index. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.2,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkHsuId,INTEGER,read-only,,mandatory,,HSU ID of specific link (if registered). Unregistered links have -1. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.3,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkState,INTEGER,read-only,,mandatory,noSync(1):violated(2):syncUnregistered(3):syncRegistered(4):authenticationError(5):swUpgradeRequired(6):syncRegisteredPassive(7):syncRegisteredALP(8),Holds the state of specific link. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.4,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkWorkingMode,INTEGER,read-only,,mandatory,unknown(1):normal(2):fullCompatibilityRemoteUpgradeAvailable(3):fullCompatibilityLocalUpgradeAvailable(4):restrictedCompatibilityRemoteUpgradeRecomended(5):restrictedCompatibilityLocalUpgradeRecomended(6):softwareUpgradeRemoteUpgradeRequired(7):softwareUpgradeLocalUpgradeRequired(8):versionsIncompatibilityRemoteUpgradeRequired(9):versionsIncompatibilityLocalUpgradeRequired(10),Indicates the sub-state within the version compatibility. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.5,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkSessionId,INTEGER,read-only,,mandatory,,Holds the Session ID of the link. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.6,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkHbsEstTput,INTEGER,read-only,,mandatory,,Holds the Estimated throughput from the HBS to the HSU. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.7,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkHsuEstTput,INTEGER,read-only,,mandatory,,Holds the Estimated throughput from the HSU to the HBS. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.8,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkRange,INTEGER,read-only,,mandatory,,Holds the range of specific link. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.9,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkHbsRss,INTEGER,read-only,,mandatory,,Holds the RSS of specific link (HBS side). +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.10,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkHbsRssBal,INTEGER,read-only,,mandatory,,Holds the RSS Balance of specific link (HBS side). -2 : Radio 2 RSS is much stronger than Radio 1 RSS. -1 : Radio 2 RSS is stronger than Radio 1 RSS. -0 : Radio 2 RSS is equal to Radio 1 RSS. 1 : Radio 1 RSS is stronger than Radio 2 RSS. 2 : Radio 1 RSS is much stronger than Radio 2 RSS. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.11,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkHsuRss,INTEGER,read-only,,mandatory,,Holds the RSS of specific link (HSU side). +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.12,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkHsuRssBal,INTEGER,read-only,,mandatory,,Holds the RSS Balance of specific link (HSU side). -2 : Radio 2 RSS is much stronger than Radio 1 RSS. -1 : Radio 2 RSS is stronger than Radio 1 RSS. -0 : Radio 2 RSS is equal to Radio 1 RSS. 1 : Radio 1 RSS is stronger than Radio 2 RSS. 2 : Radio 1 RSS is much stronger than Radio 2 RSS. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.13,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkHsuSerial,OCTET,read-only,,mandatory,,Holds the serial number for specific HSU. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.14,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkTxOperMode,INTEGER,read-only,,mandatory,regularMode(1):measurementMode(2),Holds the TX operation mode. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.15,RADWIN-MIB-WINLINK1000::winlink1000HbsAirHsuInBytes,INTEGER,read-only,,mandatory,,Number of frames received in the HSU Lan port. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.16,RADWIN-MIB-WINLINK1000::winlink1000HbsAirHsuOutBytes,INTEGER,read-only,,mandatory,,Number of frames transmitted from the HSU Lan port. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.17,RADWIN-MIB-WINLINK1000::winlink1000HbsAirHsuInFrames,INTEGER,read-only,,mandatory,,Number of bytes received in the HSU Lan port. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.18,RADWIN-MIB-WINLINK1000::winlink1000HbsAirHsuOutFrames,INTEGER,read-only,,mandatory,,Number of bytes transmitted from the HSU Lan port. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.19,RADWIN-MIB-WINLINK1000::winlink1000HbsAirHsuMacAddress,OCTET,read-only,,mandatory,,HSU MAC Address. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.20,RADWIN-MIB-WINLINK1000::winlink1000HbsAirMaxTputDown,INTEGER,read-only,,mandatory,,Max Throughput Downlink. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.21,RADWIN-MIB-WINLINK1000::winlink1000HbsAirMaxTputUp,INTEGER,read-only,,mandatory,,Max Throughput Uplink. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.22,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkCompressedMon,OCTET,read-only,,mandatory,,Holds all the link information in compressed binary (Bytes/octets). Fields included (size in bytes): Link State(1) Link Working Mode(1) Session Id(4) HBS Est. Tput(4) HSU Est. Tput(4) HBS Rss(1) HBS Rss Balance(1) HSU Rss(1) HSU Rss Balance(1) Tx Operation Mode(1) HSU In Bytes(4) HSU Out Bytes(4) HSU In Frames(4) HSU Out Frames(4) HSU ID (1 bytes) HSU Rx Rate In Kbps (4) HSU Tx Rate In Kbps (4) HSU Rx Rate In Fps (4) HSU Tx Rate In Fps (4) Peak throughput in the DL direction (4) Peak throughput in the UL direction (4) Number of local changes at HSU(1) Alignment Status(1) HBS Chain 1 Rss(1) HBS Chain 2 Rss(1) HBS Chain 3 Rss(1) HSU Chain 1 Rss(1) HSU Chain 2 Rss(1) HSU Chain 3 Rss(1) HSU Current Rate Index (2 bytes) HSU Current Rate CBW (1 bytes) HSU Current Rate GI (1 bytes) HBS Current Rate Index (2 bytes) HBS Current Rate CBW (1 bytes) HBS Current Rate GI (1 bytes) Bsa Azimuth(2) HSU LAN 1 Rx Rate In Kbps (4) HSU LAN 1 Tx Rate In Kbps (4) HSU LAN 1 Rx Rate In Fps (4) HSU LAN 1 Tx Rate In Fps (4) HSU LAN 2 Rx Rate In Kbps (4) HSU LAN 2 Tx Rate In Kbps (4) HSU LAN 2 Rx Rate In Fps (4) HSU LAN 2 Tx Rate In Fps (4) 1588TC Performance(1) SyncE Performance(1) ATPC status (1) HBS Speed(4) HSU Speed(4) Link Quality DL (4) Link Quality UL (4) IGMP MG Per CPE(2) +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.23,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkCompressedStatic,OCTET,read-only,,mandatory,,Holds all the configuration data of this link in compressed format. Helps the NMS to get info regarding new Unregistered links. Fields Included: SessionID (4 bytes) HSU IP address (4 bytes) HSU Name (32 bytes) HSU Location (32 bytes) HSU Serial number (16 bytes) HSU MAC Address (12 bytes) Air Link Range Max Throughput Down (4 bytes) Max Throughput Up. (4 bytes) Cpacity Limit (4 bytes) HSU Antenna type (1 byte) Aggregate Capacity (4 bytes) 1588TC supported (1 byte) SyncE supported (1 byte) Carrier ID +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.24,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCpeCapacityLimit,INTEGER,read-only,,mandatory,,Capacity Limit in Kilo bit per second. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.25,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkAntennaType,INTEGER,read-only,,mandatory,single(1):dual(2):undefined(3):triple(4),HSU External Antenna Type: Monopolar or Bipolar. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.26,RADWIN-MIB-WINLINK1000::winlink1000HbsAirHsuRxRateInKbps,INTEGER,read-only,,mandatory,,HSU Rx Rate in Kbps. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.27,RADWIN-MIB-WINLINK1000::winlink1000HbsAirHsuTxRateInKbps,INTEGER,read-only,,mandatory,,HSU Tx Rate in Kbps. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.28,RADWIN-MIB-WINLINK1000::winlink1000HbsAirHsuRxRateInFps,INTEGER,read-only,,mandatory,,HSU Tx Rate in Fps. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.29,RADWIN-MIB-WINLINK1000::winlink1000HbsAirHsuTxRateInFps,INTEGER,read-only,,mandatory,,HSU Tx Rate in Fps. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.30,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkPeakTputDown,INTEGER,read-only,,mandatory,,Peak throughput in the DL direction (kbps). +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.31,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkPeakTputUp,INTEGER,read-only,,mandatory,,Peak throughput in the UL direction (kbps). +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.32,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkUtilDownSecRelMill,INTEGER,read-only,,mandatory,,The average time percentage (in thousandths), out of the BTS DL capability, that was used for transmitting data to the SU. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.33,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkUtilUpSecRelMill,INTEGER,read-only,,mandatory,,The average time percentage (in thousandths), out of the BTS UL capability, that was used for receiving data from the SU. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.34,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkUtilDownAllocRelMill,INTEGER,read-only,,mandatory,,The time percentage (in thousandths), relative to the SU DL allocation, that was used for transmitting data to the SU. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.35,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkUtilUpAllocRelMill,INTEGER,read-only,,mandatory,,The time percentage (in thousandths), relative to the SU UL allocation, that was used for receiving data from the SU. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.36,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkUtilDownTrafficKbps,INTEGER,read-only,,mandatory,,Average data throughput (Exported in Kbps) transmitted in the DL towards the SU during the last second. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.37,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkUtilUpTrafficKbps,INTEGER,read-only,,mandatory,,Average data throughput (Exported in Kbps) received in the UL from the SU during the last second. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.38,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkUtilCompressedMon,OCTET,read-only,,mandatory,,One string that holds the 6 Utilization per link values: DownSecRel (2 bytes) UpSecRel (2 bytes) DownAllocRel (4 bytes) UpAllocRel (4 bytes) DownTraffic (4 bytes) UpTraffic (4 bytes). +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.39,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkBsaAzimuth,INTEGER,read-only,,mandatory,,Absolute (geographical) azimuth of the HSU (looking from HBS site). +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.40,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLink1588TCPerformance,INTEGER,read-only,,mandatory,high(1):low(2):notApplicable(3),TC performance. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.41,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkSyncEPerformance,INTEGER,read-only,,mandatory,high(1):low(2):holdover(3):syncEFailure(4):notApplicable(5):refClk(6),SyncE performance. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.42,RADWIN-MIB-WINLINK1000::winlink1000HbsAirHsuTxBytes,Counter32,read-only,,mandatory,,Accumulated Tx Bytes per link. +.1.3.6.1.4.1.4458.1000.3.1.7.2.1.43,RADWIN-MIB-WINLINK1000::winlink1000HbsAirHsuRxBytes,Counter32,read-only,,mandatory,,Accumulated Rx Bytes per link. +.1.3.6.1.4.1.4458.1000.3.1.8,RADWIN-MIB-WINLINK1000::winlink1000HbsAirComboSwitchSectorFreqBandId,INTEGER,read-write,,mandatory,,Switch Frequency band for the whole sector. +.1.3.6.1.4.1.4458.1000.3.1.9,RADWIN-MIB-WINLINK1000::winlink1000HbsAirGeoAzimuth,INTEGER,read-write,,mandatory,,Geographic sector azimuth in degrees * 10. +.1.3.6.1.4.1.4458.1000.3.1.10,RADWIN-MIB-WINLINK1000::winlink1000HbsAirGeoBeamwidth,INTEGER,read-write,,mandatory,,Geographic sector beamwidth in degrees * 10. +.1.3.6.1.4.1.4458.1000.3.1.11,RADWIN-MIB-WINLINK1000::winlink1000HbsAirMaxDistanceMetersMobility,INTEGER,read-write,,mandatory,,Maximum distance in meters. Used by Mobility links only. +.1.3.6.1.4.1.4458.1000.3.1.12,RADWIN-MIB-WINLINK1000::winlink1000HbsAirComboSwitchSectorFreqBandIdStr,OCTET,read-write,,mandatory,,Switch Frequency band for the whole sector, overriding some of the Combo parameters. +.1.3.6.1.4.1.4458.1000.3.1.13,RADWIN-MIB-WINLINK1000::winlink1000HbsAirTimeSlotAllocationBitmap,OCTET,read-write,,mandatory,,Time Slots Allocation Bitmap for the entire sector (Hex Value). +.1.3.6.1.4.1.4458.1000.3.1.14,RADWIN-MIB-WINLINK1000::winlink1000HbsAirAvailTimeSlotsUp,INTEGER,read-only,,mandatory,,This parameter holds the number of available UL time slots (not in use) in the air interface. +.1.3.6.1.4.1.4458.1000.3.1.15,RADWIN-MIB-WINLINK1000::winlink1000HbsAirDownUtilMill,INTEGER,read-only,,mandatory,,Sector Air Interface utilization in the Downlink direction (thousandths). Average time percentage, out of the entire BTS DL capability, that was used for transmitting data to all the SUs. +.1.3.6.1.4.1.4458.1000.3.1.16,RADWIN-MIB-WINLINK1000::winlink1000HbsAirUpUtilMill,INTEGER,read-only,,mandatory,,Sector Air Interface utilization in the Uplink direction (thousandths). The average number of timeslots that were used in the UL (by all the links) out of the entire number of timeslots. +.1.3.6.1.4.1.4458.1000.3.1.17,RADWIN-MIB-WINLINK1000::winlink1000HbsAirDownTrafficKbps,INTEGER,read-only,,mandatory,,Average data throughput (expressed in Kbps) transmitted in the DL towards all the SUs during the last second. +.1.3.6.1.4.1.4458.1000.3.1.18,RADWIN-MIB-WINLINK1000::winlink1000HbsAirUpTrafficKbps,INTEGER,read-only,,mandatory,,Average data throughput (expressed in Kbps) received in the UL from all the SUs during the last second. +.1.3.6.1.4.1.4458.1000.3.1.19,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCompressedMonSec,OCTET,read-only,,mandatory,,One string that holds the 4 Utilization per Sector values: DownUtil (2 bytes), UpUtil (2 bytes), DownTraffic (4 bytes), UpTraffic (4 bytes). +.1.3.6.1.4.1.4458.1000.3.1.20,RADWIN-MIB-WINLINK1000::winlink1000HbsAirDelayVsTputOpt,INTEGER,read-write,,mandatory,delaySensitivity(1):throughputOptimized(2),Delay vs. Throughput optimization type: 1 = Delay sensitivity 2 = Throughput optimized +.1.3.6.1.4.1.4458.1000.3.1.21,RADWIN-MIB-WINLINK1000::winlink1000HbsAirUCBP,,,,,, +.1.3.6.1.4.1.4458.1000.3.1.21.1,RADWIN-MIB-WINLINK1000::winlink1000HbsAirUCBPMinCS,INTEGER,read-write,,mandatory,,Minimal contention slot length used for UCBP algorithm (in ms.) between 5-20ms. +.1.3.6.1.4.1.4458.1000.3.1.21.2,RADWIN-MIB-WINLINK1000::winlink1000HbsAirUCBPSharingPercentage,INTEGER,read-write,,mandatory,,Sharing percentage used by UCBP algorithm (15-75) +.1.3.6.1.4.1.4458.1000.3.1.22,RADWIN-MIB-WINLINK1000::winlink1000HbsAirSingleHsuMode,INTEGER,read-write,,mandatory,notApplicable(1):singleHsu(2):multipleHsus(3),Single HSU mode: 1 = Not Applicable 2 = Single HSU 3 = Multiple HSUs +.1.3.6.1.4.1.4458.1000.3.1.23,RADWIN-MIB-WINLINK1000::winlink1000HbsAirMobilityAzTrack,INTEGER,read-only,,mandatory,,Azimuth tracking for mobility status: 1 = Not applicable 2 = Active 3 = Impossible +.1.3.6.1.4.1.4458.1000.3.1.24,RADWIN-MIB-WINLINK1000::winlink1000HbsAirSyncEPerformance,INTEGER,read-only,,mandatory,high(1):low(2):holdover(3):syncEFailure(4):notApplicable(5):refClk(6),SyncE performance when HBS is not reference clock +.1.3.6.1.4.1.4458.1000.3.1.25,RADWIN-MIB-WINLINK1000::winlink1000HbsAirAtpcEnable,INTEGER,read-write,,mandatory,off(1):static(2):dynamic(3):notSupported(4),ATPC mode (off, static or dynamic) status +.1.3.6.1.4.1.4458.1000.3.1.26,RADWIN-MIB-WINLINK1000::winlink1000HbsAirAtpcTargetMCS,INTEGER,read-write,,mandatory,,targetRate for ATPC operation (100-309) +.1.3.6.1.4.1.4458.1000.3.1.27,RADWIN-MIB-WINLINK1000::winlink1000HbsAirAtpcMaxAllowedRate,INTEGER,read-only,,mandatory,,Max allowed rate (will be 207 for N products and 209 for AC products) +.1.3.6.1.4.1.4458.1000.3.1.28,RADWIN-MIB-WINLINK1000::winlink1000HbsAirAtpcTargetRSSPerRateTable,,not-accessible,,mandatory,,Table of Atpc Target Rss Per Rate. +.1.3.6.1.4.1.4458.1000.3.1.28.1,RADWIN-MIB-WINLINK1000::winlink1000HbsAirAtpcMaxAllowedRateEntry,,not-accessible,winlink1000HbsAirAtpcTargetRSSPerRateIndex,mandatory,,Atpc Target Rss Per Rate table entry. +.1.3.6.1.4.1.4458.1000.3.1.28.1.1,RADWIN-MIB-WINLINK1000::winlink1000HbsAirAtpcTargetRSSPerRateIndex,INTEGER,read-only,,mandatory,,Atpc Target Rss Per Rate Index. +.1.3.6.1.4.1.4458.1000.3.1.28.1.2,RADWIN-MIB-WINLINK1000::winlink1000HbsAirAtpcTargetRSSPerRate,INTEGER,read-only,,mandatory,,Atpc Target Rss Per Rate value. +.1.3.6.1.4.1.4458.1000.3.1.29,RADWIN-MIB-WINLINK1000::winlink1000HbsAirMinimalTimeBetweenAutoRealignment,INTEGER,read-write,,mandatory,,Minimal time in seconds between two Automatic Realignment Processes +.1.3.6.1.4.1.4458.1000.3.1.30,RADWIN-MIB-WINLINK1000::winlink1000HbsAirAvailResourcesDL,INTEGER,read-only,,mandatory,,This parameter holds the number of available DL Resources (not in use) in the air interface. +.1.3.6.1.4.1.4458.1000.3.1.31,RADWIN-MIB-WINLINK1000::winlink1000HbsAirAvailResourcesUL,INTEGER,read-only,,mandatory,,This parameter holds the number of available UL Resources (not in use) in the air interface. +.1.3.6.1.4.1.4458.1000.3.1.32,RADWIN-MIB-WINLINK1000::winlink1000HbsAirHbsType,INTEGER,read-only,,mandatory,carrier(1):residential(2),HBSs Service Type Category +.1.3.6.1.4.1.4458.1000.3.1.33,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkQuality,,,,,, +.1.3.6.1.4.1.4458.1000.3.1.33.1,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkQualitySupport,INTEGER,read-only,,mandatory,notSupported(1):supported(2),Link quality detection support. +.1.3.6.1.4.1.4458.1000.3.1.33.2,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkQualityActivationStatus,INTEGER,read-write,,mandatory,disabled(1):enabled(2),Link quality detection sector activation status. +.1.3.6.1.4.1.4458.1000.3.1.33.3,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkQualityDetectionTime,INTEGER,read-write,,mandatory,,Link quality detection time in seconds. +.1.3.6.1.4.1.4458.1000.3.1.33.4,RADWIN-MIB-WINLINK1000::winlink1000HbsAirLinkQualityDetectionThreshold,INTEGER,read-write,,mandatory,,Link quality detection threshold in percentage. +.1.3.6.1.4.1.4458.1000.3.1.34,RADWIN-MIB-WINLINK1000::winlink1000HbsAirAggregatedDownlinkUtil,Counter32,read-only,,mandatory,,Aggregated Downlink Utilization per sector +.1.3.6.1.4.1.4458.1000.3.1.35,RADWIN-MIB-WINLINK1000::winlink1000HbsAirAggregatedUplinkUtil,Counter32,read-only,,mandatory,,Aggregated Uplink Utilization per sector +.1.3.6.1.4.1.4458.1000.3.1.36,RADWIN-MIB-WINLINK1000::winlink1000HbsAirAggregatedReferenceCounter,Counter32,read-only,,mandatory,,Aggregated Down link Reference counter per sector (units are symbols) +.1.3.6.1.4.1.4458.1000.3.1.37,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeTable,,not-accessible,,mandatory,,Holds the table for all CPEs in the sector. +.1.3.6.1.4.1.4458.1000.3.1.37.1,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeTableEntry,,not-accessible,winlink1000HbsAirRegisteredCpeTableIndex,mandatory,,Link table entry. +.1.3.6.1.4.1.4458.1000.3.1.37.1.1,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeTableIndex,INTEGER,read-only,,mandatory,,HSUs configuration table index. +.1.3.6.1.4.1.4458.1000.3.1.37.1.2,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeLinkId,INTEGER,read-only,,mandatory,,Link ID of specific HSU (if active link). inactive links have 255. +.1.3.6.1.4.1.4458.1000.3.1.37.1.3,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeState,INTEGER,read-only,,mandatory,noSync(1):violated(2):syncUnregistered(3):syncRegistered(4):authenticationError(5):swUpgradeRequired(6):syncRegisteredPassive(7):syncRegisteredALP(8),Holds the state of specific link. +.1.3.6.1.4.1.4458.1000.3.1.37.1.4,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeWorkingMode,INTEGER,read-only,,mandatory,unknown(1):normal(2):fullCompatibilityRemoteUpgradeAvailable(3):fullCompatibilityLocalUpgradeAvailable(4):restrictedCompatibilityRemoteUpgradeRecomended(5):restrictedCompatibilityLocalUpgradeRecomended(6):softwareUpgradeRemoteUpgradeRequired(7):softwareUpgradeLocalUpgradeRequired(8):versionsIncompatibilityRemoteUpgradeRequired(9):versionsIncompatibilityLocalUpgradeRequired(10),Indicates the sub-state within the version compatibility. +.1.3.6.1.4.1.4458.1000.3.1.37.1.5,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeSessionId,INTEGER,read-only,,mandatory,,Holds the Session ID of the link. +.1.3.6.1.4.1.4458.1000.3.1.37.1.6,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeHbsEstTput,INTEGER,read-only,,mandatory,,Holds the Estimated throughput from the HBS to the HSU. +.1.3.6.1.4.1.4458.1000.3.1.37.1.7,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeHsuEstTput,INTEGER,read-only,,mandatory,,Holds the Estimated throughput from the HSU to the HBS. +.1.3.6.1.4.1.4458.1000.3.1.37.1.8,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeRange,INTEGER,read-only,,mandatory,,Holds the range of specific link. +.1.3.6.1.4.1.4458.1000.3.1.37.1.9,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeHbsRss,INTEGER,read-only,,mandatory,,Holds the RSS of specific link (HBS side). +.1.3.6.1.4.1.4458.1000.3.1.37.1.10,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeHbsRssBal,INTEGER,read-only,,mandatory,,Holds the RSS Balance of specific link (HBS side). -2 : Radio 2 RSS is much stronger than Radio 1 RSS. -1 : Radio 2 RSS is stronger than Radio 1 RSS. -0 : Radio 2 RSS is equal to Radio 1 RSS. 1 : Radio 1 RSS is stronger than Radio 2 RSS. 2 : Radio 1 RSS is much stronger than Radio 2 RSS. +.1.3.6.1.4.1.4458.1000.3.1.37.1.11,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeHsuRss,INTEGER,read-only,,mandatory,,Holds the RSS of specific link (HSU side). +.1.3.6.1.4.1.4458.1000.3.1.37.1.12,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeHsuRssBal,INTEGER,read-only,,mandatory,,Holds the RSS Balance of specific link (HSU side). -2 : Radio 2 RSS is much stronger than Radio 1 RSS. -1 : Radio 2 RSS is stronger than Radio 1 RSS. -0 : Radio 2 RSS is equal to Radio 1 RSS. 1 : Radio 1 RSS is stronger than Radio 2 RSS. 2 : Radio 1 RSS is much stronger than Radio 2 RSS. +.1.3.6.1.4.1.4458.1000.3.1.37.1.13,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeHsuSerial,OCTET,read-only,,mandatory,,Holds the serial number for specific HSU. +.1.3.6.1.4.1.4458.1000.3.1.37.1.14,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeTxOperMode,INTEGER,read-only,,mandatory,regularMode(1):measurementMode(2),Holds the TX operation mode. +.1.3.6.1.4.1.4458.1000.3.1.37.1.15,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeHsuInBytes,INTEGER,read-only,,mandatory,,Number of frames received in the HSU Lan port. +.1.3.6.1.4.1.4458.1000.3.1.37.1.16,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeHsuOutBytes,INTEGER,read-only,,mandatory,,Number of frames transmitted from the HSU Lan port. +.1.3.6.1.4.1.4458.1000.3.1.37.1.17,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeHsuInFrames,INTEGER,read-only,,mandatory,,Number of bytes received in the HSU Lan port. +.1.3.6.1.4.1.4458.1000.3.1.37.1.18,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeHsuOutFrames,INTEGER,read-only,,mandatory,,Number of bytes transmitted from the HSU Lan port. +.1.3.6.1.4.1.4458.1000.3.1.37.1.19,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeHsuMacAddress,OCTET,read-only,,mandatory,,HSU MAC Address. +.1.3.6.1.4.1.4458.1000.3.1.37.1.20,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeMaxTputDown,INTEGER,read-only,,mandatory,,Max Throughput Downlink. +.1.3.6.1.4.1.4458.1000.3.1.37.1.21,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeMaxTputUp,INTEGER,read-only,,mandatory,,Max Throughput Uplink. +.1.3.6.1.4.1.4458.1000.3.1.37.1.22,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeCompressedMon,OCTET,read-only,,mandatory,,Holds all the link information in compressed binary (Bytes/octets). Fields included (size in bytes): Link State(1) Link Working Mode(1) Session Id(4) HBS Est. Tput(4) HSU Est. Tput(4) HBS Rss(1) HBS Rss Balance(1) HSU Rss(1) HSU Rss Balance(1) Tx Operation Mode(1) HSU In Bytes(4) HSU Out Bytes(4) HSU In Frames(4) HSU Out Frames(4) HSU ID (1 bytes) HSU Rx Rate In Kbps (4) HSU Tx Rate In Kbps (4) HSU Rx Rate In Fps (4) HSU Tx Rate In Fps (4) Peak throughput in the DL direction (4) Peak throughput in the UL direction (4) Number of local changes at HSU(1) Alignment Status(1) HBS Chain 1 Rss(1) HBS Chain 2 Rss(1) HBS Chain 3 Rss(1) HSU Chain 1 Rss(1) HSU Chain 2 Rss(1) HSU Chain 3 Rss(1) HSU Current Rate Index (2 bytes) HSU Current Rate CBW (1 bytes) HSU Current Rate GI (1 bytes) HBS Current Rate Index (2 bytes) HBS Current Rate CBW (1 bytes) HBS Current Rate GI (1 bytes) Bsa Azimuth(2) HSU LAN 1 Rx Rate In Kbps (4) HSU LAN 1 Tx Rate In Kbps (4) HSU LAN 1 Rx Rate In Fps (4) HSU LAN 1 Tx Rate In Fps (4) HSU LAN 2 Rx Rate In Kbps (4) HSU LAN 2 Tx Rate In Kbps (4) HSU LAN 2 Rx Rate In Fps (4) HSU LAN 2 Tx Rate In Fps (4) 1588TC Performance(1) SyncE Performance(1) ATPC status (1) HBS Speed(4) HSU Speed(4) IGMP MG Per CPE(2) Reserved(1) +.1.3.6.1.4.1.4458.1000.3.1.37.1.23,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeCompressedStatic,OCTET,read-only,,mandatory,,Holds all the configuration data of this link in compressed format. Helps the NMS to get info regarding new Unregistered links. Fields Included: SessionID (4 bytes) HSU IP address (4 bytes) HSU Name (32 bytes) HSU Location (32 bytes) HSU Serial number (16 bytes) HSU MAC Address (12 bytes) Air Link Range Max Throughput Down (4 bytes) Max Throughput Up. (4 bytes) Cpacity Limit (4 bytes) HSU Antenna type (1 byte) Aggregate Capacity (4 bytes) 1588TC supported (1 byte) SyncE supported (1 byte) Carrier ID (4 byte) SW version (10 byte) HW version (40 byte) +.1.3.6.1.4.1.4458.1000.3.1.37.1.24,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeCpeCapacityLimit,INTEGER,read-only,,mandatory,,Capacity Limit in Kilo bit per second. +.1.3.6.1.4.1.4458.1000.3.1.37.1.25,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeAntennaType,INTEGER,read-only,,mandatory,single(1):dual(2):undefined(3):triple(4),HSU External Antenna Type: Monopolar or Bipolar. +.1.3.6.1.4.1.4458.1000.3.1.37.1.26,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeHsuRxRateInKbps,INTEGER,read-only,,mandatory,,HSU Rx Rate in Kbps. +.1.3.6.1.4.1.4458.1000.3.1.37.1.27,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeHsuTxRateInKbps,INTEGER,read-only,,mandatory,,HSU Tx Rate in Kbps. +.1.3.6.1.4.1.4458.1000.3.1.37.1.28,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeHsuRxRateInFps,INTEGER,read-only,,mandatory,,HSU Tx Rate in Fps. +.1.3.6.1.4.1.4458.1000.3.1.37.1.29,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeHsuTxRateInFps,INTEGER,read-only,,mandatory,,HSU Tx Rate in Fps. +.1.3.6.1.4.1.4458.1000.3.1.37.1.30,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpePeakTputDown,INTEGER,read-only,,mandatory,,Peak throughput in the DL direction (kbps). +.1.3.6.1.4.1.4458.1000.3.1.37.1.31,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpePeakTputUp,INTEGER,read-only,,mandatory,,Peak throughput in the UL direction (kbps). +.1.3.6.1.4.1.4458.1000.3.1.37.1.32,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeUtilDownSecRelMill,INTEGER,read-only,,mandatory,,The average time percentage (in thousandths), out of the BTS DL capability, that was used for transmitting data to the SU. +.1.3.6.1.4.1.4458.1000.3.1.37.1.33,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeUtilUpSecRelMill,INTEGER,read-only,,mandatory,,The average time percentage (in thousandths), out of the BTS UL capability, that was used for receiving data from the SU. +.1.3.6.1.4.1.4458.1000.3.1.37.1.34,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeUtilDownAllocRelMill,INTEGER,read-only,,mandatory,,The time percentage (in thousandths), relative to the SU DL allocation, that was used for transmitting data to the SU. +.1.3.6.1.4.1.4458.1000.3.1.37.1.35,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeUtilUpAllocRelMill,INTEGER,read-only,,mandatory,,The time percentage (in thousandths), relative to the SU UL allocation, that was used for receiving data from the SU. +.1.3.6.1.4.1.4458.1000.3.1.37.1.36,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeUtilDownTrafficKbps,INTEGER,read-only,,mandatory,,Average data throughput (Exported in Kbps) transmitted in the DL towards the SU during the last second. +.1.3.6.1.4.1.4458.1000.3.1.37.1.37,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeUtilUpTrafficKbps,INTEGER,read-only,,mandatory,,Average data throughput (Exported in Kbps) received in the UL from the SU during the last second. +.1.3.6.1.4.1.4458.1000.3.1.37.1.38,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeUtilCompressedMon,OCTET,read-only,,mandatory,,One string that holds the 6 Utilization per link values: DownSecRel (2 bytes) UpSecRel (2 bytes) DownAllocRel (4 bytes) UpAllocRel (4 bytes) DownTraffic (4 bytes) UpTraffic (4 bytes). +.1.3.6.1.4.1.4458.1000.3.1.37.1.39,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeBsaAzimuth,INTEGER,read-only,,mandatory,,Absolute (geographical) azimuth of the HSU (looking from HBS site). +.1.3.6.1.4.1.4458.1000.3.1.37.1.40,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpe1588TCPerformance,INTEGER,read-only,,mandatory,high(1):low(2):notApplicable(3),TC performance. +.1.3.6.1.4.1.4458.1000.3.1.37.1.41,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeSyncEPerformance,INTEGER,read-only,,mandatory,high(1):low(2):holdover(3):syncEFailure(4):notApplicable(5):refClk(6),SyncE performance. +.1.3.6.1.4.1.4458.1000.3.1.37.1.42,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeProductName,OCTET,read-only,,mandatory,,HSU Product Name +.1.3.6.1.4.1.4458.1000.3.1.37.1.43,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeIpAddress,OCTET,read-only,,mandatory,,HSU IP Address +.1.3.6.1.4.1.4458.1000.3.1.37.1.44,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeIpAddressV6,OCTET,read-only,,mandatory,,HSU IP Address V6 +.1.3.6.1.4.1.4458.1000.3.1.37.1.45,RADWIN-MIB-WINLINK1000::winlink1000HbsAirRegisteredCpeCarrierId,INTEGER,read-only,,mandatory,,Carrier Id +.1.3.6.1.4.1.4458.1000.3.1.38,RADWIN-MIB-WINLINK1000::winlink1000HbsAirNumberOfRegisteredCpes,INTEGER,read-only,,mandatory,,Number of registered HSUs. +.1.3.6.1.4.1.4458.1000.3.1.39,RADWIN-MIB-WINLINK1000::winlink1000HbsAirNumberOfRegisteredActiveCpes,INTEGER,read-only,,mandatory,,Number of registered active HSUs. +.1.3.6.1.4.1.4458.1000.3.1.40,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierTable,,not-accessible,,mandatory,,Carrier-specific attributes that are not band-specific +.1.3.6.1.4.1.4458.1000.3.1.40.1,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierEntry,,not-accessible,winlink1000HbsAirCarrierIndex,mandatory,,Carrier table entry. +.1.3.6.1.4.1.4458.1000.3.1.40.1.1,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierIndex,INTEGER,read-only,,mandatory,carrier1(1):carrier2(2),Carrier index. +.1.3.6.1.4.1.4458.1000.3.1.40.1.2,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierState,INTEGER,read-only,,mandatory,init(1):bitFailed(2):inactive(3):spectrumMeasurement(4):scanning(5):cac(6):transceiving(7):standBy(8):rawAlignment(9),Holds the state of the HBS. +.1.3.6.1.4.1.4458.1000.3.1.40.1.3,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierOpMode,INTEGER,read-write,,mandatory,inactive(1):active(2),Holds the operation mode of the HBS. +.1.3.6.1.4.1.4458.1000.3.1.40.1.4,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierSectorCbwSupportedStr,OCTET,read-only,,mandatory,,Represents the channel bandwidth which is supported by the HBS and all connected HSUs. +.1.3.6.1.4.1.4458.1000.3.1.40.1.5,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierComboSwitchSectorFreqBandIdStr,OCTET,read-write,,mandatory,,Switch Frequency band for the whole sector, overriding some of the Combo parameters. +.1.3.6.1.4.1.4458.1000.3.1.40.1.6,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierDelayVsTputOpt,INTEGER,read-write,,mandatory,delaySensitivity(1):throughputOptimized(2),Delay vs. Throughput optimization type: 1 = Delay sensitivity 2 = Throughput optimized +.1.3.6.1.4.1.4458.1000.3.1.40.1.7,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierAtpcEnable,INTEGER,read-write,,mandatory,off(1):static(2):dynamic(3):notSupported(4),ATPC mode (off, static or dynamic) status +.1.3.6.1.4.1.4458.1000.3.1.40.1.8,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierAtpcTargetMCS,INTEGER,read-write,,mandatory,,targetRate for ATPC operation (100-309) +.1.3.6.1.4.1.4458.1000.3.1.40.1.9,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierAtpcMaxAllowedRate,INTEGER,read-only,,mandatory,,Max allowed rate (will be 207 for N products and 209 for AC products) +.1.3.6.1.4.1.4458.1000.3.1.40.1.10,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierAvailResourcesDL,INTEGER,read-only,,mandatory,,This parameter holds the number of available DL Resources (not in use) in the air interface. +.1.3.6.1.4.1.4458.1000.3.1.40.1.11,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierAvailResourcesUL,INTEGER,read-only,,mandatory,,This parameter holds the number of available UL Resources (not in use) in the air interface. +.1.3.6.1.4.1.4458.1000.3.1.40.1.12,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierBEPercentage,OCTET,read-write,,mandatory,,BE allocation percentage from the total resources (DownLink|UpLink|). +.1.3.6.1.4.1.4458.1000.3.1.40.1.13,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierMaxNumOfBeHsus,INTEGER,read-only,,mandatory,,This parameter holds the maximum number of Best Effort Hsus. +.1.3.6.1.4.1.4458.1000.3.1.41,RADWIN-MIB-WINLINK1000::winlink1000HbsAirAggregatedReferenceCounterUplink,Counter32,read-only,,mandatory,,Aggregated Up link Reference counter per sector (units are symbols) +.1.3.6.1.4.1.4458.1000.3.1.42,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierInformationTable,,not-accessible,,mandatory,,Carrier-specific attributes that are not band-specific +.1.3.6.1.4.1.4458.1000.3.1.42.1,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierInformationEntry,,not-accessible,winlink1000HbsAirCarrierInformationIndex,mandatory,,Carrier table entry. +.1.3.6.1.4.1.4458.1000.3.1.42.1.1,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierInformationIndex,INTEGER,read-only,,mandatory,carrier1(1):carrier2(2),Carrier index. +.1.3.6.1.4.1.4458.1000.3.1.42.1.2,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierInformationSubBandDescription,OCTET,read-only,,mandatory,,Carrier Current Sub Band description. +.1.3.6.1.4.1.4458.1000.3.1.42.1.3,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierInformationState,INTEGER,read-only,,mandatory,init(1):bitFailed(2):inactive(3):spectrumMeasurement(4):scanning(5):cac(6):transceiving(7):standBy(8):rawAlignment(9),Holds the state of the HBS. +.1.3.6.1.4.1.4458.1000.3.1.42.1.4,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierInformationFrequency,INTEGER,read-only,,mandatory,,Current Center Frequency. Measured in MHz if center frequency resolution value < 100, otherwise in KHz. +.1.3.6.1.4.1.4458.1000.3.1.42.1.5,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierInformationTxPower,INTEGER,read-only,,mandatory,,Current Transmit Power in dBm. This is a nominal value while the actual transmit power includes additional attenuation. +.1.3.6.1.4.1.4458.1000.3.1.42.1.6,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierInformationTotalTxPower,INTEGER,read-only,,mandatory,,Total Transmit Power in dBm. This is a nominal value While the actual transmit power includes additional attenuation. +.1.3.6.1.4.1.4458.1000.3.1.42.1.7,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierInformationChannelBandwidth,INTEGER,read-only,,mandatory,,Channel bandwidth in KHz. A change is effective after reset. +.1.3.6.1.4.1.4458.1000.3.1.42.1.8,RADWIN-MIB-WINLINK1000::winlink1000HbsAirCarrierInformationAntennaGain,INTEGER,read-only,,mandatory,,Current Antenna Gain in 0.1 dBi resolution. User defined value for external antenna. Legal range: MinAntennaGain port will reset). +.1.3.6.1.4.1.4458.1000.100,RADWIN-MIB-WINLINK1000::winlink1000General,,,,,, +.1.3.6.1.4.1.4458.1000.100.1,RADWIN-MIB-WINLINK1000::winlink1000GeneralTrapDescription,OCTET,read-only,,mandatory,,Trap's Description. Used for Trap parameters. +.1.3.6.1.4.1.4458.1000.100.2,RADWIN-MIB-WINLINK1000::winlink1000GeneralTrapSeverity,INTEGER,read-only,,mandatory,event(1):normal(2):warning(4):minor(8):major(16):critical(32),Trap's Severity. Used for Trap parameters. +.1.3.6.1.4.1.4458.1000.100.3,RADWIN-MIB-WINLINK1000::winlink1000GeneralCookie,OCTET,read-write,,mandatory,,Reserved for the Manager application provided with the product, used for saving user preferences affecting ODU operation. +.1.3.6.1.4.1.4458.1000.100.4,RADWIN-MIB-WINLINK1000::winlink1000GeneralEcChangesCounter,INTEGER,read-only,,mandatory,,This counter is initialized to 0 after a device reset and is incremented upon each element constant write operation via SNMP or Telnet. +.1.3.6.1.4.1.4458.1000.100.5,RADWIN-MIB-WINLINK1000::winlink1000GeneralTelnetSupport,INTEGER,read-write,,mandatory,enable(1):disable(2):mandatoryDisabled(3):mandatoryEnabled(4),Enable/Disable Telnet protocol. Mandatory Disabled - No option to enable the feature. Mandatory Enabled - No option to disable the feature. +.1.3.6.1.4.1.4458.1000.100.6,RADWIN-MIB-WINLINK1000::winlink1000GeneralWISupport,INTEGER,read-write,,mandatory,mandatoryDisabled(1):mandatoryEnabled(2):disabled(3):enabled(4):securedOnlyEnabled(5):securedDisabled(6):securedAllModesEnabled(7):securedAllModesDisabled(8),Enable/Disable Web Interface protocol. Mandatory Disabled - No option to enable the feature. Mandatory Enabled - No option to disable the feature. Secured Only Enabled - enable select HTTPS only. Secured Disabled - disable HTTPS. Secured all Enabled - enable select HTTP and HTTPS. +.1.3.6.1.4.1.4458.1000.100.7,RADWIN-MIB-WINLINK1000::winlink1000GeneralSNMPSupport,INTEGER,read-write,,mandatory,v1Andv3(1):snmpv1Only(2):snmpv3Only(3),Configuration of SNMP version +.1.3.6.1.4.1.4458.1000.100.8,RADWIN-MIB-WINLINK1000::winlink1000GeneralSSHSupport,INTEGER,read-write,,mandatory,enabled(1):disabled(2):unsupported(3),Enable/Disable SSH protocols +.1.3.6.1.4.1.4458.1000.100.9,RADWIN-MIB-WINLINK1000::winlink1000GeneralStrictHTTPS,INTEGER,read-write,,mandatory,disabled(1):enabled(2),Strict HTTPS Mode +.1.3.6.1.4.1.4458.1000.100.10,RADWIN-MIB-WINLINK1000::winlink1000GeneralIPForwarding,INTEGER,read-write,,mandatory,enabled(1):disabled(2),Enable/Disable IP forwarding +.1.3.6.1.5,SNMPv2-SMI::security,,,,,, +.1.3.6.1.6,SNMPv2-SMI::snmpV2,,,,,, +.1.3.6.1.6.1,SNMPv2-SMI::snmpDomains,,,,,, +.1.3.6.1.6.2,SNMPv2-SMI::snmpProxys,,,,,, +.1.3.6.1.6.3,SNMPv2-SMI::snmpModules,,,,,, diff --git a/EXTRAS/reports/silver-peak_oids b/EXTRAS/reports/silver-peak_oids index cce342ff..13040fff 100644 --- a/EXTRAS/reports/silver-peak_oids +++ b/EXTRAS/reports/silver-peak_oids @@ -73,6 +73,10 @@ .1.3.6.1.4.1.23867.1.2.60,SILVERPEAK-PRODUCTS-MIB::spsECLH,,,,,, .1.3.6.1.4.1.23867.1.2.61,SILVERPEAK-PRODUCTS-MIB::spsECXLH,,,,,, .1.3.6.1.4.1.23867.1.2.62,SILVERPEAK-PRODUCTS-MIB::spsECXLH10G,,,,,, +.1.3.6.1.4.1.23867.1.2.63,SILVERPEAK-PRODUCTS-MIB::spsEC10104,,,,,, +.1.3.6.1.4.1.23867.1.2.64,SILVERPEAK-PRODUCTS-MIB::spsEC10106,,,,,, +.1.3.6.1.4.1.23867.1.2.65,SILVERPEAK-PRODUCTS-MIB::spsEC10108,,,,,, +.1.3.6.1.4.1.23867.1.2.66,SILVERPEAK-PRODUCTS-MIB::spsECMH,,,,,, .1.3.6.1.4.1.23867.2,SILVERPEAK-SMI::silverpeakModules,,,,,,silverpeakModules provides a root object identifier from which MODULE-ENTITY values may be assigned. .1.3.6.1.4.1.23867.2.1,SILVERPEAK-TC::silverpeakTextualConventions,,,,,,This module defines the textual conventions used throughout Silverpeak Systems enterprise mibs. .1.3.6.1.4.1.23867.3,SILVERPEAK-SMI::silverpeakMgmt,,,,,,silverpeakMgmt is the main subtree for management mibs. @@ -100,7 +104,7 @@ .1.3.6.1.4.1.23867.3.1.1.2.1.1.10,SILVERPEAK-MGMT-MIB::spsActiveAlarmClearable,INTEGER,read-only,,current,no(0):yes(1),Identifies if the user can manually clear the alarm. .1.3.6.1.4.1.23867.3.1.1.2.1.1.11,SILVERPEAK-MGMT-MIB::spsActiveAlarmLogTime,OCTET,read-only,,current,,The value of sysUpTime when the alarm was generated. .1.3.6.1.4.1.23867.3.1.1.2.1.1.12,SILVERPEAK-MGMT-MIB::spsActiveAlarmServiceAffect,INTEGER,read-only,,current,no(0):yes(1),Identifies if the alarm is service affecting. -.1.3.6.1.4.1.23867.3.1.1.2.1.1.13,SILVERPEAK-MGMT-MIB::spsActiveAlarmTypeId,INTEGER,read-only,,current,,An ID that uniquely identifies a type of alarm. The following is a list of currently defined type IDs (ID listed below is in hexadecimal): ID Description ----- ------------------------------------------ 10000 Tunnel remote ID is misconfigured 10001 Tunnel state is Down 10002 Tunnel VRRP IP is misconfigured 10003 Tunnel keepalive version mismatch 10004 Tunnel WCCP GID is misconfigured 10005 Tunnel software version mismatch 10006 Connecting to a non-VX-X is not supported. Please contact sales@silver-peak.com to discuss your options. 10007 Duplicate Silver Peak license detected on peer device. 10008 Tunnel local IP address not owned by this appliance 10009 Tunnel software version mismatch results in reduced functionality. 1000a Tunnel peer encapsulation mode mismatch detected. 1000b UDP Destination Port is the same as flow redirection port 20000 Tunnel has unexpected traffic class error 30000 RAID array is degraded 30001 Disk is failed 30002 Disk is degraded 30003 Fan failure detected 30004 System bypass mode 30005 LAN/WAN fail-to-wire card failure 30006 LAN/WAN fail-to-wire card relay failure 30007 Encryption card hardware failure 30008 Network interface admin down 30009 Network interface link down 3000a Management interface link down 3000b Interface is half duplex 3000c Interface speed is 10 Mbps 3000d Config DB disk full 3000e Operating System disk full 3000f File system disk full 30010 Datapath internal loopback test failed 30011 WAN next-hop unreachable 30012 VRRP instance is down 30013 VRRP state changed from Master to Backup 30014 WAN next-hop router discovered on a LAN port (box is in backwards) 30015 Disk is not in service 30016 Disk is rebuilding 30017 Disk removed by operator 30018 LAN/WAN interfaces have different admin states 30019 LAN/WAN interfaces have different link carrier states 3001a LAN/WAN interface has been shutdown due to link propagation of paired interface 3001b Disk SMART threshold exceeded 3001c Flow redirection cluster peer is down 3001d Bonding members have different speed/duplex 3001e WCCP adjacency(ies) down 3001f WCCP assignment table mismatch 30020 Power supply not connected, not powered or failed 30021 NIC interface failure 30022 LAN next-hop unreachable 30023 Unexpected system restart 30024 Insufficient configured memory size for this virtual appliance 30025 Insufficient configured processor count for this virtual appliance 30026 Insufficient configured disk storage for this virtual appliance 30027 Interfaces have different MTUs 30028 Interfaces have different MTUs 30029 Bridge loop is detected 3002a Bridge creation failed 3002b Network interface is unassigned 3002c System optimization turned off 3002d Sub-optimal configured memory size for this virtual appliance 3002e Sub-optimal configured processor count for this virtual appliance 3002f Sub-optimal configured disk storage for this virtual appliance 40000 Software upgrade process has failed 40001 System is low on resources 40002 Significant change in time of day has occurred, and might compromise statistics. 40003 The licensing for this virtual appliance has expired. 4 +.1.3.6.1.4.1.23867.3.1.1.2.1.1.13,SILVERPEAK-MGMT-MIB::spsActiveAlarmTypeId,INTEGER,read-only,,current,,An ID that uniquely identifies a type of alarm. The following is a list of currently defined type IDs (ID listed below is in hexadecimal): ID Description ----- ------------------------------------------ 10000 Tunnel remote ID is misconfigured 10001 Tunnel state is Down 10002 Tunnel VRRP IP is misconfigured 10003 Tunnel keepalive version mismatch 10004 Tunnel WCCP GID is misconfigured 10005 Tunnel software version mismatch 10006 Connecting to a non-VX-X is not supported. Please contact sales@silver-peak.com to discuss your options. 10007 Duplicate Silver Peak license detected on peer device. 10008 Tunnel local IP address not owned by this appliance 10009 Tunnel software version mismatch results in reduced functionality. 1000a Tunnel peer encapsulation mode mismatch detected. 1000b UDP Destination Port is the same as flow redirection port 20000 Tunnel has unexpected traffic class error 30000 RAID array is degraded 30001 Disk is failed 30002 Disk is degraded 30003 Fan failure detected 30004 System bypass mode 30005 LAN/WAN fail-to-wire card failure 30006 LAN/WAN fail-to-wire card relay failure 30007 Encryption card hardware failure 30008 Network interface admin down 30009 Network interface link down 3000a Management interface link down 3000b Interface is half duplex 3000c Interface speed is 10 Mbps 3000d Config DB disk full 3000e Operating System disk full 3000f File system disk full 30010 Datapath internal loopback test failed 30011 WAN next-hop unreachable 30012 VRRP instance is down 30013 VRRP state changed from Master to Backup 30014 WAN next-hop router discovered on a LAN port (box is in backwards) 30015 Disk is not in service 30016 Disk is rebuilding 30017 Disk removed by operator 30018 LAN/WAN interfaces have different admin states 30019 LAN/WAN interfaces have different link carrier states 3001a LAN/WAN interface has been shutdown due to link propagation of paired interface 3001b Disk SMART threshold exceeded 3001c Flow redirection cluster peer is down 3001d Bonding members have different speed/duplex 3001e WCCP adjacency(ies) down 3001f WCCP assignment table mismatch 30020 Power supply not connected, not powered or failed 30021 NIC interface failure 30022 LAN next-hop unreachable 30023 Unexpected system restart 30024 Insufficient configured memory size for this virtual appliance 30025 Insufficient configured processor count for this virtual appliance 30026 Insufficient configured disk storage for this virtual appliance 30027 Interfaces have different MTUs 30028 Interfaces have different MTUs 30029 Bridge loop is detected 3002a Bridge creation failed 3002b Network interface is unassigned 3002c System optimization turned off 3002d Sub-optimal configured memory size for this virtual appliance 3002e Sub-optimal configured processor count for this virtual appliance 3002f Sub-optimal configured disk storage for this virtual appliance 30030 USB-LTE modem connection has degraded 30031 USB-LTE modem is unreachable 30032 USB-LTE modem cannot begin a call 30033 USB-LTE modem not supported on this appliance 30034 Unsupported USB-LTE modem connected to this appliance 300 .1.3.6.1.4.1.23867.3.1.2,SILVERPEAK-MGMT-MIB::silverpeakMgmtMIBConformance,,,,,, .1.3.6.1.4.1.23867.3.1.2.1,SILVERPEAK-MGMT-MIB::silverpeakMgmtMIBCompliances,,,,,, .1.3.6.1.4.1.23867.3.1.2.1.1,SILVERPEAK-MGMT-MIB::silverpeakMgmtCompliance,,,,,,The compliance statement for agents implementing silverpeakMgmtMIB.