You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
1729038071019,"2024-10-16T00:21:11.019Z error graph/graph.go:426 Failed to start component {""error"": ""failed to initialize NodeCapacity: lstat /rootfs/proc: no such file or directory"", ""type"": ""Receiver"", ""id"": ""awscontainerinsightreceiver""}"
1729038071019,2024-10-16T00:21:11.019Z info [email protected]/service.go:270 Starting shutdown...
Additional context
No response
The text was updated successfully, but these errors were encountered:
Component(s)
receiver/awscontainerinsight
What happened?
Description
Even if the
HOST_PROC
env var is set the receiver can fail to start if the default host proc (/rootfs/proc
) doesn't exist.Steps to Reproduce
Run the receiver in a image without
/rootfs/proc
but withHOST_PROC
env var set to a valid location.Expected Result
The receiver should use the value in
HOST_PROC
and start without issues.Actual Result
The receiver fails to start and triggers a shutdown of the collector.
Collector version
v0.111.0
Environment information
Environment
OS: (e.g., "Ubuntu 20.04")
Compiler(if manually compiled): (e.g., "go 14.2")
OpenTelemetry Collector configuration
No response
Log output
Additional context
No response
The text was updated successfully, but these errors were encountered: