MQTT subscribe to change Axis from Y > Z #33

Open
andygrillo opened this issue Jul 14, 2021 · 2 comments
Open

MQTT subscribe to change Axis from Y > Z #33

andygrillo opened this issue Jul 14, 2021 · 2 comments

Comments

@andygrillo
Copy link
Member

Allows mounting of sensor on floor.

@johnwalicki
Copy link
Member

I don't understand the requirement. Doesn't this happen when the ADXL355 sensor is calibrated?

  • Turn off the device
  • Mount it in a particular orientation
  • Turn on the device
  • The ADXL355 will be calibrated in that orientation.

@andygrillo
Copy link
Member Author

Not to my knowledge.

I thought the calibration only remove the offset from each axis. It doesn't specify which of 3 axis is 'up'.