Notifications
You must be signed in to change notification settings - Fork 26
InfluxDB Schema
Paresh Gupta edited this page Jul 21, 2020
·
5 revisions
Tag keys | Tag values |
---|---|
domain | IP address |
fi_id | A or B |
location | string |
Field keys | Field values |
---|---|
fi_fw_sys_ver | string |
load | float |
mem_available | float |
mode | string |
model | string |
name | string |
oob_if_ip | string |
ucsm_fw_ver | string |
serial | string |
sys_uptime | float |
total_memory | float |
Tag keys | Tag values |
---|---|
channel |
|
domain | IP address |
fi_id | A or B |
location | string |
port | x/yy or PC-xxxx |
transport | FC or Eth |
Field keys | Field values |
---|---|
admin_state | string |
bytes_rx_delta | float |
bytes_tx_delta | float |
crc_rx_delta | float |
description | string |
discard_rx_delta | float |
discard_tx_delta | float |
fcs_delta | float |
link_failures_delta | float |
oper_speed | float |
oper_state | string |
out_discard_delta | float |
pause_rx | float |
pause_tx | float |
signal_losses_delta | float |
sync_losses_delta | float |
Tag keys | Tag Values | Connected to 5108 Chassis | Connected to Rack server | Connected to FEX | Connected to S-series server |
---|---|---|---|---|---|
channel |
|
||||
domain | IP address | ||||
fi_id | A or B | ||||
location | string | ||||
peer | chassis-x | rack-unit-x | fex-x | chassis-x | |
peer_type | chassis | rack | FEX | S-chassis | |
peer_port | x/yy | slot-2/fabric/port-1 | adaptor-1/ext-eth-1 | slot-1/fabric/port-1 | slot-1/shared-io-module/fabric/port-4 |
port | x/yy or PC-xxxx | ||||
transport |
|
Field keys | Field values |
---|---|
admin_state | string |
bytes_rx_delta | float |
bytes_tx_delta | float |
description | string |
fcs_delta | float |
oper_speed | float |
oper_state | string |
out_discard_delta | float |
pause_rx | float |
pause_tx | float |
Tag keys | Tag Values | In 5108 Chassis | to Rack server | to FEX | to S-series server |
---|---|---|---|---|---|
bp_port | x/yy or x/PC-xxxx | ||||
channel |
|
||||
chassis | ?? | ||||
domain | IP address | ||||
fi_id | A or B | ||||
fi_server_port | x/yy or PC-xxxx | ||||
peer | blade-x | rack-unit-x | N/A | chassis-x | |
peer_type | blade | rack | N/A | S-chassis | |
peer_port | x/yy | adaptor-2/ext-eth-5 | adaptor-1/ext-eth-1 | N/A | slot-2/shared-io-module/fabric/port-5 |
peer_service_profile | string |
Field keys | Field values |
---|---|
bytes_rx_delta | float |
bytes_tx_delta | float |
fcs_delta | float |
oper_state | string |
out_discard_delta | float |
pause_rx | float |
pause_tx | float |
speed | float |
Tag keys | Tag Values | blades in 5108 Chassis | to Rack server | to FEX | to S-series server |
---|---|---|---|---|---|
chassis | ?? | ||||
domain | IP address | ||||
id | blade-x | rack-unit-x | N/A | blade-x | |
location | string | ||||
service_profile | string | ||||
type | blade | rack | N/A | blade |
Field keys | Field values |
---|---|
admin_state | string |
association | string |
memory | float |
model | string |
num_adaptors | float |
num_cores | float |
num_cpus | float |
num_vEths | float |
num_vFCs | float |
oper_state | string |
oper_state_code | float |
operability | string |
serial | string |
Tag keys | Tag Values | blades in 5108 Chassis | in Rack server | in FEX | in S-series server |
---|---|---|---|---|---|
adaptor | adaptor-x | ||||
bound_veth | string | ||||
bound_vfc | string | ||||
chassis | chassis-x | rack-unit-x | N/A | chassis-x | |
domain | IP Address | ||||
domain_name | string | ||||
fi_id | A or B | ||||
location | string | ||||
peer | IOM-x | FI-A or FI-B or fex-x | N/A | FI-A or FI-B or fex-x | |
peer_type | IOM | FI or FEX | N/A | FI or FEX | |
peer_port | x/yy | slot-1/host/port-3 | slot-1/switch-ether/port-5 or slot-1/host/port-29 | N/A | FI port from fi_port_dictor FEX port from per_bp_port_dict |
server | blade-x | rack-unit-x | N/A | blade-x | |
profile | string | ||||
transport | FC or Eth | ||||
vif_name | string |
Field keys | Field values |
---|---|
bytes_rx_delta | float |
bytes_tx_delta | float |
dropped_rx_delta | float |
dropped_tx_delta | float |
errors_rx_delta | float |
errors_tx_delta | float |