diff --git a/CHANGELOG.md b/CHANGELOG.md index 2659884db..0fe60ca33 100644 --- a/CHANGELOG.md +++ b/CHANGELOG.md @@ -33,6 +33,7 @@ Writeable Text entities have moved from type `sensor` to `text` in Home Assistan - shower_data MQTT payload contains the timestamp [#1329](https://github.com/emsesp/EMS-ESP32/issues/1329) - fixed helper text in Web Device Entity dialog box for numerical ranges - MQTT base with paths not working in HA [#1393](https://github.com/emsesp/EMS-ESP32/issues/1393) +- set/read thermostat mode for RC100-RC300, [#1440](https://github.com/emsesp/EMS-ESP32/issues/1440) [#1442](https://github.com/emsesp/EMS-ESP32/issues/1442) ## Changed diff --git a/dump_entities.csv b/dump_entities.csv index 4f76189c7..e194bb37b 100644 --- a/dump_entities.csv +++ b/dump_entities.csv @@ -1,8 +1,189 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/max),uom,writeable,discovery entityid v3.4, discovery entityid -BK13/BK15/Smartline/GB1x2,boiler,64,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +CS6800i/WLW176i,boiler,8,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +CS6800i/WLW176i,boiler,8,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff +CS6800i/WLW176i,boiler,8,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive +CS6800i/WLW176i,boiler,8,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive +CS6800i/WLW176i,boiler,8,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +CS6800i/WLW176i,boiler,8,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +CS6800i/WLW176i,boiler,8,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +CS6800i/WLW176i,boiler,8,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +CS6800i/WLW176i,boiler,8,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +CS6800i/WLW176i,boiler,8,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +CS6800i/WLW176i,boiler,8,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +CS6800i/WLW176i,boiler,8,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +CS6800i/WLW176i,boiler,8,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +CS6800i/WLW176i,boiler,8,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated +CS6800i/WLW176i,boiler,8,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +CS6800i/WLW176i,boiler,8,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump +CS6800i/WLW176i,boiler,8,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +CS6800i/WLW176i,boiler,8,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +CS6800i/WLW176i,boiler,8,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +CS6800i/WLW176i,boiler,8,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +CS6800i/WLW176i,boiler,8,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +CS6800i/WLW176i,boiler,8,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +CS6800i/WLW176i,boiler,8,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +CS6800i/WLW176i,boiler,8,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +CS6800i/WLW176i,boiler,8,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +CS6800i/WLW176i,boiler,8,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +CS6800i/WLW176i,boiler,8,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +CS6800i/WLW176i,boiler,8,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +CS6800i/WLW176i,boiler,8,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +CS6800i/WLW176i,boiler,8,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +CS6800i/WLW176i,boiler,8,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode +CS6800i/WLW176i,boiler,8,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode +CS6800i/WLW176i,boiler,8,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +CS6800i/WLW176i,boiler,8,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage +CS6800i/WLW176i,boiler,8,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance +CS6800i/WLW176i,boiler,8,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +CS6800i/WLW176i,boiler,8,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate +CS6800i/WLW176i,boiler,8,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops +CS6800i/WLW176i,boiler,8,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +CS6800i/WLW176i,boiler,8,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +CS6800i/WLW176i,boiler,8,nrgww,energy,ulong (>=0<=167772),kWh,false,sensor.boiler_energy,sensor.boiler_nrgww +CS6800i/WLW176i,boiler,8,nrgheat,energy heating,ulong (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat +CS6800i/WLW176i,boiler,8,metertotal,meter total,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal +CS6800i/WLW176i,boiler,8,metercomp,meter compressor,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp +CS6800i/WLW176i,boiler,8,metereheat,meter e-heater,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat +CS6800i/WLW176i,boiler,8,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal +CS6800i/WLW176i,boiler,8,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol +CS6800i/WLW176i,boiler,8,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating +CS6800i/WLW176i,boiler,8,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling +CS6800i/WLW176i,boiler,8,uptimecompww,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor,sensor.boiler_uptimecompww +CS6800i/WLW176i,boiler,8,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool +CS6800i/WLW176i,boiler,8,totalcompstarts,total compressor control starts,ulong (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts +CS6800i/WLW176i,boiler,8,heatingstarts,heating control starts,ulong (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts +CS6800i/WLW176i,boiler,8,coolingstarts,cooling control starts,ulong (>=0<=16777213), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts +CS6800i/WLW176i,boiler,8,wwstarts2,control starts2,ulong (>=0<=16777213), ,false,sensor.boiler_control_starts2,sensor.boiler_wwstarts2 +CS6800i/WLW176i,boiler,8,poolstarts,pool control starts,ulong (>=0<=16777213), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts +CS6800i/WLW176i,boiler,8,nrgconstotal,total energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal +CS6800i/WLW176i,boiler,8,nrgconscomptotal,total energy consumption compressor,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal +CS6800i/WLW176i,boiler,8,nrgconscompheating,energy consumption compressor heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating +CS6800i/WLW176i,boiler,8,nrgconscompww,energy consumption compressor,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor,sensor.boiler_nrgconscompww +CS6800i/WLW176i,boiler,8,nrgconscompcooling,energy consumption compressor cooling,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling +CS6800i/WLW176i,boiler,8,nrgconscomppool,energy consumption compressor pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool +CS6800i/WLW176i,boiler,8,auxelecheatnrgconstotal,total aux elec. heater energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal +CS6800i/WLW176i,boiler,8,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating +CS6800i/WLW176i,boiler,8,auxelecheatnrgconsww,aux elec. heater energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconsww +CS6800i/WLW176i,boiler,8,auxelecheatnrgconspool,aux elec. heater energy consumption pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool +CS6800i/WLW176i,boiler,8,nrgsupptotal,total energy supplied,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal +CS6800i/WLW176i,boiler,8,nrgsuppheating,total energy supplied heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating +CS6800i/WLW176i,boiler,8,nrgsuppww,total energy warm supplied,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_warm_supplied,sensor.boiler_nrgsuppww +CS6800i/WLW176i,boiler,8,nrgsuppcooling,total energy supplied cooling,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling +CS6800i/WLW176i,boiler,8,nrgsupppool,total energy supplied pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool +CS6800i/WLW176i,boiler,8,hppower,compressor power output,uint (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower +CS6800i/WLW176i,boiler,8,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon +CS6800i/WLW176i,boiler,8,hpactivity,compressor activity,enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity +CS6800i/WLW176i,boiler,8,hpbrinepumpspd,brine pump speed,uint (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd +CS6800i/WLW176i,boiler,8,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve +CS6800i/WLW176i,boiler,8,hpcompspd,compressor speed,uint (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd +CS6800i/WLW176i,boiler,8,hpcircspd,circulation pump speed,uint (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd +CS6800i/WLW176i,boiler,8,hpbrinein,brine in/evaporator,short (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein +CS6800i/WLW176i,boiler,8,hpbrineout,brine out/condenser,short (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout +CS6800i/WLW176i,boiler,8,hptc0,heat carrier return (TC0),short (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0 +CS6800i/WLW176i,boiler,8,hptc1,heat carrier forward (TC1),short (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1 +CS6800i/WLW176i,boiler,8,hptc3,condenser temperature (TC3),short (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3 +CS6800i/WLW176i,boiler,8,hptr1,compressor temperature (TR1),short (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1 +CS6800i/WLW176i,boiler,8,hptr3,refrigerant temperature liquid side (condenser output) (TR3),short (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3 +CS6800i/WLW176i,boiler,8,hptr4,evaporator inlet temperature (TR4),short (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4 +CS6800i/WLW176i,boiler,8,hptr5,compressor inlet temperature (TR5),short (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5 +CS6800i/WLW176i,boiler,8,hptr6,compressor outlet temperature (TR6),short (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6 +CS6800i/WLW176i,boiler,8,hptr7,refrigerant temperature gas side (condenser input) (TR7),short (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7 +CS6800i/WLW176i,boiler,8,hptl2,air inlet temperature (TL2),short (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2 +CS6800i/WLW176i,boiler,8,hppl1,low pressure side temperature (PL1),short (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1 +CS6800i/WLW176i,boiler,8,hpph1,high pressure side temperature (PH1),short (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1 +CS6800i/WLW176i,boiler,8,hpta4,drain pan temp (TA4),short (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4 +CS6800i/WLW176i,boiler,8,hptw1,reservoir temp (TW1),short (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1 +CS6800i/WLW176i,boiler,8,poolsettemp,pool set temperature,uint (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp +CS6800i/WLW176i,boiler,8,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way +CS6800i/WLW176i,boiler,8,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt +CS6800i/WLW176i,boiler,8,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt +CS6800i/WLW176i,boiler,8,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt +CS6800i/WLW176i,boiler,8,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt +CS6800i/WLW176i,boiler,8,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp +CS6800i/WLW176i,boiler,8,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat +CS6800i/WLW176i,boiler,8,maxheatdhw,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit,select.boiler_maxheatdhw +CS6800i/WLW176i,boiler,8,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost +CS6800i/WLW176i,boiler,8,pvcooling,Cooling only with PV,boolean, ,true,switch.boiler_Cooling_only_with_PV,switch.boiler_pvcooling +CS6800i/WLW176i,boiler,8,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly +CS6800i/WLW176i,boiler,8,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff +CS6800i/WLW176i,boiler,8,auxheaterstatus,aux heater status,boolean, ,false,binary_sensor.boiler_aux_heater_status,binary_sensor.boiler_auxheaterstatus +CS6800i/WLW176i,boiler,8,auxheaterdelay,aux heater on delay,ushort (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay +CS6800i/WLW176i,boiler,8,auxmaxlimit,aux heater max limit,uint (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit +CS6800i/WLW176i,boiler,8,auxlimitstart,aux heater limit start,uint (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart +CS6800i/WLW176i,boiler,8,auxheatrmode,aux heater mode,enum [eco\|comfort], ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode +CS6800i/WLW176i,boiler,8,hphystheat,on/off hyst heat,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat +CS6800i/WLW176i,boiler,8,hphystcool,on/off hyst cool,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool +CS6800i/WLW176i,boiler,8,hphystpool,on/off hyst pool,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool +CS6800i/WLW176i,boiler,8,silentmode,silent mode,enum [off\|auto\|on], ,true,select.boiler_silent_mode,select.boiler_silentmode +CS6800i/WLW176i,boiler,8,silentfrom,silent mode from,uint (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom +CS6800i/WLW176i,boiler,8,silentto,silent mode to,uint (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto +CS6800i/WLW176i,boiler,8,mintempsilent,min outside temp for silent mode,int (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent +CS6800i/WLW176i,boiler,8,tempparmode,outside temp parallel mode,int (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode +CS6800i/WLW176i,boiler,8,auxheatmix,aux heater mixing valve,int (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix +CS6800i/WLW176i,boiler,8,tempdiffheat,temp diff TC3/TC0 heat,uint (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat +CS6800i/WLW176i,boiler,8,tempdiffcool,temp diff TC3/TC0 cool,uint (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool +CS6800i/WLW176i,boiler,8,vpcooling,valve/pump cooling,boolean, ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling +CS6800i/WLW176i,boiler,8,heatcable,heating cable,boolean, ,true,switch.boiler_heating_cable,switch.boiler_heatcable +CS6800i/WLW176i,boiler,8,vc0valve,VC0 valve,boolean, ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve +CS6800i/WLW176i,boiler,8,primepump,primary heatpump,boolean, ,true,switch.boiler_primary_heatpump,switch.boiler_primepump +CS6800i/WLW176i,boiler,8,primepumpmod,primary heatpump modulation,uint (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod +CS6800i/WLW176i,boiler,8,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,switch.boiler_hp3way +CS6800i/WLW176i,boiler,8,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1 +CS6800i/WLW176i,boiler,8,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2 +CS6800i/WLW176i,boiler,8,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3 +CS6800i/WLW176i,boiler,8,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0 +CS6800i/WLW176i,boiler,8,wwalternatingop,alternating operation,boolean, ,true,switch.boiler_alternating_operation,switch.boiler_wwalternatingop +CS6800i/WLW176i,boiler,8,wwaltopprioheat,prioritise heating during dhw,uint (>=20<=120),minutes,true,number.boiler_prioritise_heating_during_dhw,number.boiler_wwaltopprioheat +CS6800i/WLW176i,boiler,8,wwaltopprioww,prioritise dhw during heating,uint (>=30<=120),minutes,true,number.boiler_prioritise_dhw_during_heating,number.boiler_wwaltopprioww +CS6800i/WLW176i,boiler,8,wwcomfoff,comfort switch off,uint (>=15<=65),C,true,number.boiler_comfort_switch_off,number.boiler_wwcomfoff +CS6800i/WLW176i,boiler,8,wwecooff,eco switch off,uint (>=15<=65),C,true,number.boiler_eco_switch_off,number.boiler_wwecooff +CS6800i/WLW176i,boiler,8,wwecoplusoff,eco+ switch off,uint (>=48<=63),C,true,number.boiler_eco+_switch_off,number.boiler_wwecoplusoff +CS6800i/WLW176i,boiler,8,hpcircpumpww,circulation pump available during dhw,boolean, ,true,switch.boiler_circulation_pump_available_during_dhw,switch.boiler_hpcircpumpww +CS6800i/WLW176i,boiler,8,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated +CS6800i/WLW176i,boiler,8,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp +CS6800i/WLW176i,boiler,8,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp +CS6800i/WLW176i,boiler,8,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +CS6800i/WLW176i,boiler,8,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus +CS6800i/WLW176i,boiler,8,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff +CS6800i/WLW176i,boiler,8,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle +CS6800i/WLW176i,boiler,8,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp +CS6800i/WLW176i,boiler,8,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype +CS6800i/WLW176i,boiler,8,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort +CS6800i/WLW176i,boiler,8,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 +CS6800i/WLW176i,boiler,8,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset +CS6800i/WLW176i,boiler,8,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization +CS6800i/WLW176i,boiler,8,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower +CS6800i/WLW176i,boiler,8,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +CS6800i/WLW176i,boiler,8,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump +CS6800i/WLW176i,boiler,8,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype +CS6800i/WLW176i,boiler,8,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston +CS6800i/WLW176i,boiler,8,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff +CS6800i/WLW176i,boiler,8,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +CS6800i/WLW176i,boiler,8,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode +CS6800i/WLW176i,boiler,8,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc +CS6800i/WLW176i,boiler,8,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp +CS6800i/WLW176i,boiler,8,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 +CS6800i/WLW176i,boiler,8,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow +CS6800i/WLW176i,boiler,8,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 +CS6800i/WLW176i,boiler,8,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 +CS6800i/WLW176i,boiler,8,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated +CS6800i/WLW176i,boiler,8,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime +CS6800i/WLW176i,boiler,8,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting +CS6800i/WLW176i,boiler,8,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging +CS6800i/WLW176i,boiler,8,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging +CS6800i/WLW176i,boiler,8,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok +CS6800i/WLW176i,boiler,8,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive +CS6800i/WLW176i,boiler,8,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve +CS6800i/WLW176i,boiler,8,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower +CS6800i/WLW176i,boiler,8,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp +CS6800i/WLW176i,boiler,8,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp +CS6800i/WLW176i,boiler,8,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +CS6800i/WLW176i,boiler,8,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +BK13/BK15/Smartline/GB1x2,boiler,64,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +BK13/BK15/Smartline/GB1x2,boiler,64,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff BK13/BK15/Smartline/GB1x2,boiler,64,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive BK13/BK15/Smartline/GB1x2,boiler,64,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -BK13/BK15/Smartline/GB1x2,boiler,64,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +BK13/BK15/Smartline/GB1x2,boiler,64,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp BK13/BK15/Smartline/GB1x2,boiler,64,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod BK13/BK15/Smartline/GB1x2,boiler,64,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp BK13/BK15/Smartline/GB1x2,boiler,64,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -10,38 +191,38 @@ BK13/BK15/Smartline/GB1x2,boiler,64,rettemp,return temperature,ushort (>=0<=3199 BK13/BK15/Smartline/GB1x2,boiler,64,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp BK13/BK15/Smartline/GB1x2,boiler,64,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress BK13/BK15/Smartline/GB1x2,boiler,64,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +BK13/BK15/Smartline/GB1x2,boiler,64,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp BK13/BK15/Smartline/GB1x2,boiler,64,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp BK13/BK15/Smartline/GB1x2,boiler,64,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas BK13/BK15/Smartline/GB1x2,boiler,64,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 BK13/BK15/Smartline/GB1x2,boiler,64,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -BK13/BK15/Smartline/GB1x2,boiler,64,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump BK13/BK15/Smartline/GB1x2,boiler,64,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork BK13/BK15/Smartline/GB1x2,boiler,64,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork BK13/BK15/Smartline/GB1x2,boiler,64,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +BK13/BK15/Smartline/GB1x2,boiler,64,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +BK13/BK15/Smartline/GB1x2,boiler,64,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +BK13/BK15/Smartline/GB1x2,boiler,64,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +BK13/BK15/Smartline/GB1x2,boiler,64,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +BK13/BK15/Smartline/GB1x2,boiler,64,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +BK13/BK15/Smartline/GB1x2,boiler,64,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +BK13/BK15/Smartline/GB1x2,boiler,64,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff BK13/BK15/Smartline/GB1x2,boiler,64,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -BK13/BK15/Smartline/GB1x2,boiler,64,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +BK13/BK15/Smartline/GB1x2,boiler,64,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +BK13/BK15/Smartline/GB1x2,boiler,64,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump BK13/BK15/Smartline/GB1x2,boiler,64,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax BK13/BK15/Smartline/GB1x2,boiler,64,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin BK13/BK15/Smartline/GB1x2,boiler,64,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -BK13/BK15/Smartline/GB1x2,boiler,64,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -BK13/BK15/Smartline/GB1x2,boiler,64,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -BK13/BK15/Smartline/GB1x2,boiler,64,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -BK13/BK15/Smartline/GB1x2,boiler,64,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -BK13/BK15/Smartline/GB1x2,boiler,64,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -BK13/BK15/Smartline/GB1x2,boiler,64,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -BK13/BK15/Smartline/GB1x2,boiler,64,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -BK13/BK15/Smartline/GB1x2,boiler,64,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +BK13/BK15/Smartline/GB1x2,boiler,64,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay BK13/BK15/Smartline/GB1x2,boiler,64,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp BK13/BK15/Smartline/GB1x2,boiler,64,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -BK13/BK15/Smartline/GB1x2,boiler,64,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow BK13/BK15/Smartline/GB1x2,boiler,64,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow BK13/BK15/Smartline/GB1x2,boiler,64,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -BK13/BK15/Smartline/GB1x2,boiler,64,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -BK13/BK15/Smartline/GB1x2,boiler,64,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -BK13/BK15/Smartline/GB1x2,boiler,64,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -BK13/BK15/Smartline/GB1x2,boiler,64,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -BK13/BK15/Smartline/GB1x2,boiler,64,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -BK13/BK15/Smartline/GB1x2,boiler,64,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +BK13/BK15/Smartline/GB1x2,boiler,64,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +BK13/BK15/Smartline/GB1x2,boiler,64,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +BK13/BK15/Smartline/GB1x2,boiler,64,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +BK13/BK15/Smartline/GB1x2,boiler,64,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +BK13/BK15/Smartline/GB1x2,boiler,64,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +BK13/BK15/Smartline/GB1x2,boiler,64,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime BK13/BK15/Smartline/GB1x2,boiler,64,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode BK13/BK15/Smartline/GB1x2,boiler,64,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode BK13/BK15/Smartline/GB1x2,boiler,64,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -55,6 +236,7 @@ BK13/BK15/Smartline/GB1x2,boiler,64,wwtapactivated,turn on/off,boolean, ,true,sw BK13/BK15/Smartline/GB1x2,boiler,64,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp BK13/BK15/Smartline/GB1x2,boiler,64,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp BK13/BK15/Smartline/GB1x2,boiler,64,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +BK13/BK15/Smartline/GB1x2,boiler,64,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus BK13/BK15/Smartline/GB1x2,boiler,64,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff BK13/BK15/Smartline/GB1x2,boiler,64,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle BK13/BK15/Smartline/GB1x2,boiler,64,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -64,12 +246,12 @@ BK13/BK15/Smartline/GB1x2,boiler,64,wwcomfort1,comfort mode,enum [high comfort\| BK13/BK15/Smartline/GB1x2,boiler,64,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset BK13/BK15/Smartline/GB1x2,boiler,64,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization BK13/BK15/Smartline/GB1x2,boiler,64,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -BK13/BK15/Smartline/GB1x2,boiler,64,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +BK13/BK15/Smartline/GB1x2,boiler,64,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp BK13/BK15/Smartline/GB1x2,boiler,64,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump BK13/BK15/Smartline/GB1x2,boiler,64,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype BK13/BK15/Smartline/GB1x2,boiler,64,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston BK13/BK15/Smartline/GB1x2,boiler,64,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -BK13/BK15/Smartline/GB1x2,boiler,64,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +BK13/BK15/Smartline/GB1x2,boiler,64,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp BK13/BK15/Smartline/GB1x2,boiler,64,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode BK13/BK15/Smartline/GB1x2,boiler,64,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc BK13/BK15/Smartline/GB1x2,boiler,64,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -88,12 +270,17 @@ BK13/BK15/Smartline/GB1x2,boiler,64,ww3wayvalve,3-way valve active,boolean, ,fal BK13/BK15/Smartline/GB1x2,boiler,64,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower BK13/BK15/Smartline/GB1x2,boiler,64,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp BK13/BK15/Smartline/GB1x2,boiler,64,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -BK13/BK15/Smartline/GB1x2,boiler,64,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -BK13/BK15/Smartline/GB1x2,boiler,64,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -GB125/GB135/MC10,boiler,72,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +BK13/BK15/Smartline/GB1x2,boiler,64,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +BK13/BK15/Smartline/GB1x2,boiler,64,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +BK13/BK15/Smartline/GB1x2,boiler,64,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +BK13/BK15/Smartline/GB1x2,boiler,64,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +BK13/BK15/Smartline/GB1x2,boiler,64,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +BK13/BK15/Smartline/GB1x2,boiler,64,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +GB125/GB135/MC10,boiler,72,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +GB125/GB135/MC10,boiler,72,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff GB125/GB135/MC10,boiler,72,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive GB125/GB135/MC10,boiler,72,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -GB125/GB135/MC10,boiler,72,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +GB125/GB135/MC10,boiler,72,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp GB125/GB135/MC10,boiler,72,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod GB125/GB135/MC10,boiler,72,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp GB125/GB135/MC10,boiler,72,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -101,38 +288,38 @@ GB125/GB135/MC10,boiler,72,rettemp,return temperature,ushort (>=0<=3199),C,false GB125/GB135/MC10,boiler,72,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp GB125/GB135/MC10,boiler,72,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress GB125/GB135/MC10,boiler,72,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +GB125/GB135/MC10,boiler,72,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp GB125/GB135/MC10,boiler,72,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp GB125/GB135/MC10,boiler,72,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas GB125/GB135/MC10,boiler,72,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 GB125/GB135/MC10,boiler,72,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -GB125/GB135/MC10,boiler,72,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump GB125/GB135/MC10,boiler,72,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork GB125/GB135/MC10,boiler,72,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork GB125/GB135/MC10,boiler,72,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +GB125/GB135/MC10,boiler,72,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +GB125/GB135/MC10,boiler,72,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +GB125/GB135/MC10,boiler,72,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +GB125/GB135/MC10,boiler,72,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +GB125/GB135/MC10,boiler,72,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +GB125/GB135/MC10,boiler,72,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +GB125/GB135/MC10,boiler,72,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff GB125/GB135/MC10,boiler,72,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -GB125/GB135/MC10,boiler,72,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +GB125/GB135/MC10,boiler,72,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +GB125/GB135/MC10,boiler,72,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump GB125/GB135/MC10,boiler,72,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax GB125/GB135/MC10,boiler,72,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin GB125/GB135/MC10,boiler,72,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -GB125/GB135/MC10,boiler,72,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -GB125/GB135/MC10,boiler,72,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -GB125/GB135/MC10,boiler,72,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -GB125/GB135/MC10,boiler,72,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -GB125/GB135/MC10,boiler,72,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -GB125/GB135/MC10,boiler,72,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -GB125/GB135/MC10,boiler,72,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -GB125/GB135/MC10,boiler,72,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +GB125/GB135/MC10,boiler,72,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay GB125/GB135/MC10,boiler,72,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp GB125/GB135/MC10,boiler,72,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -GB125/GB135/MC10,boiler,72,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow GB125/GB135/MC10,boiler,72,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow GB125/GB135/MC10,boiler,72,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -GB125/GB135/MC10,boiler,72,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -GB125/GB135/MC10,boiler,72,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -GB125/GB135/MC10,boiler,72,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -GB125/GB135/MC10,boiler,72,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -GB125/GB135/MC10,boiler,72,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -GB125/GB135/MC10,boiler,72,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +GB125/GB135/MC10,boiler,72,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +GB125/GB135/MC10,boiler,72,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +GB125/GB135/MC10,boiler,72,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +GB125/GB135/MC10,boiler,72,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +GB125/GB135/MC10,boiler,72,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +GB125/GB135/MC10,boiler,72,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime GB125/GB135/MC10,boiler,72,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode GB125/GB135/MC10,boiler,72,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode GB125/GB135/MC10,boiler,72,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -146,6 +333,7 @@ GB125/GB135/MC10,boiler,72,wwtapactivated,turn on/off,boolean, ,true,switch.boil GB125/GB135/MC10,boiler,72,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp GB125/GB135/MC10,boiler,72,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp GB125/GB135/MC10,boiler,72,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +GB125/GB135/MC10,boiler,72,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus GB125/GB135/MC10,boiler,72,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff GB125/GB135/MC10,boiler,72,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle GB125/GB135/MC10,boiler,72,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -155,12 +343,12 @@ GB125/GB135/MC10,boiler,72,wwcomfort1,comfort mode,enum [high comfort\|eco], ,tr GB125/GB135/MC10,boiler,72,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset GB125/GB135/MC10,boiler,72,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization GB125/GB135/MC10,boiler,72,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -GB125/GB135/MC10,boiler,72,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +GB125/GB135/MC10,boiler,72,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp GB125/GB135/MC10,boiler,72,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump GB125/GB135/MC10,boiler,72,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype GB125/GB135/MC10,boiler,72,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston GB125/GB135/MC10,boiler,72,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -GB125/GB135/MC10,boiler,72,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +GB125/GB135/MC10,boiler,72,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp GB125/GB135/MC10,boiler,72,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode GB125/GB135/MC10,boiler,72,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc GB125/GB135/MC10,boiler,72,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -179,12 +367,17 @@ GB125/GB135/MC10,boiler,72,ww3wayvalve,3-way valve active,boolean, ,false,binary GB125/GB135/MC10,boiler,72,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower GB125/GB135/MC10,boiler,72,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp GB125/GB135/MC10,boiler,72,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -GB125/GB135/MC10,boiler,72,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -GB125/GB135/MC10,boiler,72,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Cascade CM10,boiler,81,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +GB125/GB135/MC10,boiler,72,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +GB125/GB135/MC10,boiler,72,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +GB125/GB135/MC10,boiler,72,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +GB125/GB135/MC10,boiler,72,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +GB125/GB135/MC10,boiler,72,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +GB125/GB135/MC10,boiler,72,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +Cascade CM10,boiler,81,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Cascade CM10,boiler,81,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Cascade CM10,boiler,81,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Cascade CM10,boiler,81,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Cascade CM10,boiler,81,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Cascade CM10,boiler,81,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Cascade CM10,boiler,81,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Cascade CM10,boiler,81,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Cascade CM10,boiler,81,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -192,38 +385,38 @@ Cascade CM10,boiler,81,rettemp,return temperature,ushort (>=0<=3199),C,false,sen Cascade CM10,boiler,81,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Cascade CM10,boiler,81,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Cascade CM10,boiler,81,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Cascade CM10,boiler,81,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Cascade CM10,boiler,81,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Cascade CM10,boiler,81,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Cascade CM10,boiler,81,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Cascade CM10,boiler,81,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Cascade CM10,boiler,81,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Cascade CM10,boiler,81,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Cascade CM10,boiler,81,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Cascade CM10,boiler,81,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +Cascade CM10,boiler,81,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Cascade CM10,boiler,81,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Cascade CM10,boiler,81,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Cascade CM10,boiler,81,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Cascade CM10,boiler,81,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Cascade CM10,boiler,81,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Cascade CM10,boiler,81,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Cascade CM10,boiler,81,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Cascade CM10,boiler,81,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Cascade CM10,boiler,81,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Cascade CM10,boiler,81,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Cascade CM10,boiler,81,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Cascade CM10,boiler,81,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Cascade CM10,boiler,81,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Cascade CM10,boiler,81,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Cascade CM10,boiler,81,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Cascade CM10,boiler,81,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Cascade CM10,boiler,81,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Cascade CM10,boiler,81,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Cascade CM10,boiler,81,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Cascade CM10,boiler,81,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Cascade CM10,boiler,81,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Cascade CM10,boiler,81,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Cascade CM10,boiler,81,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Cascade CM10,boiler,81,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Cascade CM10,boiler,81,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Cascade CM10,boiler,81,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Cascade CM10,boiler,81,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Cascade CM10,boiler,81,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Cascade CM10,boiler,81,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Cascade CM10,boiler,81,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Cascade CM10,boiler,81,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Cascade CM10,boiler,81,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Cascade CM10,boiler,81,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Cascade CM10,boiler,81,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Cascade CM10,boiler,81,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Cascade CM10,boiler,81,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Cascade CM10,boiler,81,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Cascade CM10,boiler,81,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Cascade CM10,boiler,81,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Cascade CM10,boiler,81,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Cascade CM10,boiler,81,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Cascade CM10,boiler,81,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -237,6 +430,7 @@ Cascade CM10,boiler,81,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_t Cascade CM10,boiler,81,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Cascade CM10,boiler,81,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Cascade CM10,boiler,81,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Cascade CM10,boiler,81,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Cascade CM10,boiler,81,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Cascade CM10,boiler,81,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Cascade CM10,boiler,81,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -246,12 +440,12 @@ Cascade CM10,boiler,81,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,s Cascade CM10,boiler,81,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Cascade CM10,boiler,81,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Cascade CM10,boiler,81,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Cascade CM10,boiler,81,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Cascade CM10,boiler,81,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Cascade CM10,boiler,81,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Cascade CM10,boiler,81,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Cascade CM10,boiler,81,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Cascade CM10,boiler,81,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Cascade CM10,boiler,81,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Cascade CM10,boiler,81,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Cascade CM10,boiler,81,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Cascade CM10,boiler,81,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Cascade CM10,boiler,81,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -270,12 +464,17 @@ Cascade CM10,boiler,81,ww3wayvalve,3-way valve active,boolean, ,false,binary_sen Cascade CM10,boiler,81,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Cascade CM10,boiler,81,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Cascade CM10,boiler,81,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Cascade CM10,boiler,81,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Cascade CM10,boiler,81,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Logamax Plus GB022,boiler,84,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +Cascade CM10,boiler,81,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Cascade CM10,boiler,81,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Cascade CM10,boiler,81,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Cascade CM10,boiler,81,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Cascade CM10,boiler,81,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Cascade CM10,boiler,81,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +Logamax Plus GB022,boiler,84,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Logamax Plus GB022,boiler,84,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logamax Plus GB022,boiler,84,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Logamax Plus GB022,boiler,84,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Logamax Plus GB022,boiler,84,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Logamax Plus GB022,boiler,84,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Logamax Plus GB022,boiler,84,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Logamax Plus GB022,boiler,84,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Logamax Plus GB022,boiler,84,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -283,38 +482,38 @@ Logamax Plus GB022,boiler,84,rettemp,return temperature,ushort (>=0<=3199),C,fal Logamax Plus GB022,boiler,84,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Logamax Plus GB022,boiler,84,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Logamax Plus GB022,boiler,84,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Logamax Plus GB022,boiler,84,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Logamax Plus GB022,boiler,84,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Logamax Plus GB022,boiler,84,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Logamax Plus GB022,boiler,84,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Logamax Plus GB022,boiler,84,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Logamax Plus GB022,boiler,84,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Logamax Plus GB022,boiler,84,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Logamax Plus GB022,boiler,84,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Logamax Plus GB022,boiler,84,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +Logamax Plus GB022,boiler,84,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Logamax Plus GB022,boiler,84,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Logamax Plus GB022,boiler,84,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Logamax Plus GB022,boiler,84,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Logamax Plus GB022,boiler,84,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Logamax Plus GB022,boiler,84,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Logamax Plus GB022,boiler,84,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Logamax Plus GB022,boiler,84,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Logamax Plus GB022,boiler,84,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Logamax Plus GB022,boiler,84,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Logamax Plus GB022,boiler,84,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Logamax Plus GB022,boiler,84,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Logamax Plus GB022,boiler,84,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logamax Plus GB022,boiler,84,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Logamax Plus GB022,boiler,84,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Logamax Plus GB022,boiler,84,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Logamax Plus GB022,boiler,84,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Logamax Plus GB022,boiler,84,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Logamax Plus GB022,boiler,84,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Logamax Plus GB022,boiler,84,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Logamax Plus GB022,boiler,84,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Logamax Plus GB022,boiler,84,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Logamax Plus GB022,boiler,84,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Logamax Plus GB022,boiler,84,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Logamax Plus GB022,boiler,84,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Logamax Plus GB022,boiler,84,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Logamax Plus GB022,boiler,84,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Logamax Plus GB022,boiler,84,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Logamax Plus GB022,boiler,84,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Logamax Plus GB022,boiler,84,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Logamax Plus GB022,boiler,84,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Logamax Plus GB022,boiler,84,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Logamax Plus GB022,boiler,84,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Logamax Plus GB022,boiler,84,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Logamax Plus GB022,boiler,84,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Logamax Plus GB022,boiler,84,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Logamax Plus GB022,boiler,84,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Logamax Plus GB022,boiler,84,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Logamax Plus GB022,boiler,84,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Logamax Plus GB022,boiler,84,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Logamax Plus GB022,boiler,84,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Logamax Plus GB022,boiler,84,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Logamax Plus GB022,boiler,84,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -328,6 +527,7 @@ Logamax Plus GB022,boiler,84,wwtapactivated,turn on/off,boolean, ,true,switch.bo Logamax Plus GB022,boiler,84,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Logamax Plus GB022,boiler,84,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Logamax Plus GB022,boiler,84,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Logamax Plus GB022,boiler,84,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Logamax Plus GB022,boiler,84,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Logamax Plus GB022,boiler,84,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Logamax Plus GB022,boiler,84,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -337,12 +537,12 @@ Logamax Plus GB022,boiler,84,wwcomfort1,comfort mode,enum [high comfort\|eco], , Logamax Plus GB022,boiler,84,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Logamax Plus GB022,boiler,84,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Logamax Plus GB022,boiler,84,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Logamax Plus GB022,boiler,84,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Logamax Plus GB022,boiler,84,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Logamax Plus GB022,boiler,84,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Logamax Plus GB022,boiler,84,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Logamax Plus GB022,boiler,84,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Logamax Plus GB022,boiler,84,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Logamax Plus GB022,boiler,84,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Logamax Plus GB022,boiler,84,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Logamax Plus GB022,boiler,84,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Logamax Plus GB022,boiler,84,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Logamax Plus GB022,boiler,84,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -361,12 +561,17 @@ Logamax Plus GB022,boiler,84,ww3wayvalve,3-way valve active,boolean, ,false,bina Logamax Plus GB022,boiler,84,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Logamax Plus GB022,boiler,84,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Logamax Plus GB022,boiler,84,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Logamax Plus GB022,boiler,84,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Logamax Plus GB022,boiler,84,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +Logamax Plus GB022,boiler,84,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Logamax Plus GB022,boiler,84,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Logamax Plus GB022,boiler,84,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Logamax Plus GB022,boiler,84,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Logamax Plus GB022,boiler,84,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Logamax Plus GB022,boiler,84,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -374,38 +579,38 @@ Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,rette Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -419,6 +624,7 @@ Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwtap Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -428,12 +634,12 @@ Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcom Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -452,12 +658,17 @@ Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,ww3wa Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Topline/GB162,boiler,115,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +Topline/GB162,boiler,115,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Topline/GB162,boiler,115,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Topline/GB162,boiler,115,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Topline/GB162,boiler,115,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Topline/GB162,boiler,115,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Topline/GB162,boiler,115,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Topline/GB162,boiler,115,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Topline/GB162,boiler,115,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Topline/GB162,boiler,115,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -465,38 +676,38 @@ Topline/GB162,boiler,115,rettemp,return temperature,ushort (>=0<=3199),C,false,s Topline/GB162,boiler,115,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Topline/GB162,boiler,115,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Topline/GB162,boiler,115,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Topline/GB162,boiler,115,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Topline/GB162,boiler,115,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Topline/GB162,boiler,115,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Topline/GB162,boiler,115,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Topline/GB162,boiler,115,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Topline/GB162,boiler,115,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Topline/GB162,boiler,115,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Topline/GB162,boiler,115,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Topline/GB162,boiler,115,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +Topline/GB162,boiler,115,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Topline/GB162,boiler,115,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Topline/GB162,boiler,115,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Topline/GB162,boiler,115,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Topline/GB162,boiler,115,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Topline/GB162,boiler,115,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Topline/GB162,boiler,115,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Topline/GB162,boiler,115,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Topline/GB162,boiler,115,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Topline/GB162,boiler,115,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Topline/GB162,boiler,115,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Topline/GB162,boiler,115,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Topline/GB162,boiler,115,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Topline/GB162,boiler,115,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Topline/GB162,boiler,115,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Topline/GB162,boiler,115,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Topline/GB162,boiler,115,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Topline/GB162,boiler,115,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Topline/GB162,boiler,115,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Topline/GB162,boiler,115,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Topline/GB162,boiler,115,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Topline/GB162,boiler,115,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Topline/GB162,boiler,115,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Topline/GB162,boiler,115,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Topline/GB162,boiler,115,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Topline/GB162,boiler,115,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Topline/GB162,boiler,115,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Topline/GB162,boiler,115,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Topline/GB162,boiler,115,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Topline/GB162,boiler,115,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Topline/GB162,boiler,115,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Topline/GB162,boiler,115,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Topline/GB162,boiler,115,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Topline/GB162,boiler,115,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Topline/GB162,boiler,115,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Topline/GB162,boiler,115,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Topline/GB162,boiler,115,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Topline/GB162,boiler,115,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Topline/GB162,boiler,115,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Topline/GB162,boiler,115,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Topline/GB162,boiler,115,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Topline/GB162,boiler,115,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Topline/GB162,boiler,115,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -510,6 +721,7 @@ Topline/GB162,boiler,115,wwtapactivated,turn on/off,boolean, ,true,switch.boiler Topline/GB162,boiler,115,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Topline/GB162,boiler,115,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Topline/GB162,boiler,115,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Topline/GB162,boiler,115,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Topline/GB162,boiler,115,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Topline/GB162,boiler,115,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Topline/GB162,boiler,115,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -519,12 +731,12 @@ Topline/GB162,boiler,115,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true Topline/GB162,boiler,115,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Topline/GB162,boiler,115,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Topline/GB162,boiler,115,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Topline/GB162,boiler,115,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Topline/GB162,boiler,115,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Topline/GB162,boiler,115,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Topline/GB162,boiler,115,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Topline/GB162,boiler,115,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Topline/GB162,boiler,115,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Topline/GB162,boiler,115,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Topline/GB162,boiler,115,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Topline/GB162,boiler,115,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Topline/GB162,boiler,115,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Topline/GB162,boiler,115,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -543,12 +755,17 @@ Topline/GB162,boiler,115,ww3wayvalve,3-way valve active,boolean, ,false,binary_s Topline/GB162,boiler,115,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Topline/GB162,boiler,115,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Topline/GB162,boiler,115,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Topline/GB162,boiler,115,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Topline/GB162,boiler,115,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Cascade MCM10,boiler,121,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +Topline/GB162,boiler,115,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Topline/GB162,boiler,115,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Topline/GB162,boiler,115,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Topline/GB162,boiler,115,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Topline/GB162,boiler,115,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Topline/GB162,boiler,115,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +Cascade MCM10,boiler,121,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Cascade MCM10,boiler,121,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Cascade MCM10,boiler,121,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Cascade MCM10,boiler,121,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Cascade MCM10,boiler,121,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Cascade MCM10,boiler,121,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Cascade MCM10,boiler,121,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Cascade MCM10,boiler,121,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Cascade MCM10,boiler,121,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -556,38 +773,38 @@ Cascade MCM10,boiler,121,rettemp,return temperature,ushort (>=0<=3199),C,false,s Cascade MCM10,boiler,121,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Cascade MCM10,boiler,121,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Cascade MCM10,boiler,121,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Cascade MCM10,boiler,121,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Cascade MCM10,boiler,121,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Cascade MCM10,boiler,121,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Cascade MCM10,boiler,121,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Cascade MCM10,boiler,121,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Cascade MCM10,boiler,121,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Cascade MCM10,boiler,121,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Cascade MCM10,boiler,121,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Cascade MCM10,boiler,121,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +Cascade MCM10,boiler,121,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Cascade MCM10,boiler,121,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Cascade MCM10,boiler,121,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Cascade MCM10,boiler,121,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Cascade MCM10,boiler,121,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Cascade MCM10,boiler,121,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Cascade MCM10,boiler,121,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Cascade MCM10,boiler,121,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Cascade MCM10,boiler,121,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Cascade MCM10,boiler,121,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Cascade MCM10,boiler,121,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Cascade MCM10,boiler,121,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Cascade MCM10,boiler,121,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Cascade MCM10,boiler,121,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Cascade MCM10,boiler,121,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Cascade MCM10,boiler,121,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Cascade MCM10,boiler,121,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Cascade MCM10,boiler,121,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Cascade MCM10,boiler,121,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Cascade MCM10,boiler,121,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Cascade MCM10,boiler,121,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Cascade MCM10,boiler,121,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Cascade MCM10,boiler,121,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Cascade MCM10,boiler,121,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Cascade MCM10,boiler,121,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Cascade MCM10,boiler,121,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Cascade MCM10,boiler,121,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Cascade MCM10,boiler,121,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Cascade MCM10,boiler,121,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Cascade MCM10,boiler,121,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Cascade MCM10,boiler,121,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Cascade MCM10,boiler,121,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Cascade MCM10,boiler,121,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Cascade MCM10,boiler,121,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Cascade MCM10,boiler,121,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Cascade MCM10,boiler,121,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Cascade MCM10,boiler,121,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Cascade MCM10,boiler,121,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Cascade MCM10,boiler,121,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Cascade MCM10,boiler,121,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Cascade MCM10,boiler,121,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Cascade MCM10,boiler,121,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Cascade MCM10,boiler,121,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -601,6 +818,7 @@ Cascade MCM10,boiler,121,wwtapactivated,turn on/off,boolean, ,true,switch.boiler Cascade MCM10,boiler,121,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Cascade MCM10,boiler,121,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Cascade MCM10,boiler,121,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Cascade MCM10,boiler,121,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Cascade MCM10,boiler,121,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Cascade MCM10,boiler,121,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Cascade MCM10,boiler,121,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -610,12 +828,12 @@ Cascade MCM10,boiler,121,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true Cascade MCM10,boiler,121,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Cascade MCM10,boiler,121,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Cascade MCM10,boiler,121,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Cascade MCM10,boiler,121,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Cascade MCM10,boiler,121,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Cascade MCM10,boiler,121,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Cascade MCM10,boiler,121,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Cascade MCM10,boiler,121,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Cascade MCM10,boiler,121,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Cascade MCM10,boiler,121,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Cascade MCM10,boiler,121,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Cascade MCM10,boiler,121,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Cascade MCM10,boiler,121,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Cascade MCM10,boiler,121,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -634,12 +852,17 @@ Cascade MCM10,boiler,121,ww3wayvalve,3-way valve active,boolean, ,false,binary_s Cascade MCM10,boiler,121,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Cascade MCM10,boiler,121,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Cascade MCM10,boiler,121,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Cascade MCM10,boiler,121,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Cascade MCM10,boiler,121,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Proline,boiler,122,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +Cascade MCM10,boiler,121,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Cascade MCM10,boiler,121,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Cascade MCM10,boiler,121,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Cascade MCM10,boiler,121,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Cascade MCM10,boiler,121,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Cascade MCM10,boiler,121,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +Proline,boiler,122,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Proline,boiler,122,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Proline,boiler,122,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Proline,boiler,122,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Proline,boiler,122,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Proline,boiler,122,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Proline,boiler,122,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Proline,boiler,122,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Proline,boiler,122,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -647,38 +870,38 @@ Proline,boiler,122,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor. Proline,boiler,122,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Proline,boiler,122,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Proline,boiler,122,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Proline,boiler,122,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Proline,boiler,122,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Proline,boiler,122,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Proline,boiler,122,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Proline,boiler,122,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Proline,boiler,122,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Proline,boiler,122,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Proline,boiler,122,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Proline,boiler,122,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +Proline,boiler,122,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Proline,boiler,122,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Proline,boiler,122,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Proline,boiler,122,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Proline,boiler,122,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Proline,boiler,122,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Proline,boiler,122,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Proline,boiler,122,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Proline,boiler,122,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Proline,boiler,122,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Proline,boiler,122,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Proline,boiler,122,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Proline,boiler,122,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Proline,boiler,122,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Proline,boiler,122,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Proline,boiler,122,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Proline,boiler,122,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Proline,boiler,122,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Proline,boiler,122,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Proline,boiler,122,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Proline,boiler,122,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Proline,boiler,122,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Proline,boiler,122,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Proline,boiler,122,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Proline,boiler,122,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Proline,boiler,122,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Proline,boiler,122,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Proline,boiler,122,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Proline,boiler,122,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Proline,boiler,122,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Proline,boiler,122,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Proline,boiler,122,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Proline,boiler,122,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Proline,boiler,122,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Proline,boiler,122,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Proline,boiler,122,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Proline,boiler,122,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Proline,boiler,122,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Proline,boiler,122,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Proline,boiler,122,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Proline,boiler,122,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Proline,boiler,122,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Proline,boiler,122,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -692,6 +915,7 @@ Proline,boiler,122,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_ Proline,boiler,122,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Proline,boiler,122,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Proline,boiler,122,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Proline,boiler,122,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Proline,boiler,122,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Proline,boiler,122,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Proline,boiler,122,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -701,12 +925,12 @@ Proline,boiler,122,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,selec Proline,boiler,122,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Proline,boiler,122,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Proline,boiler,122,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Proline,boiler,122,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Proline,boiler,122,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Proline,boiler,122,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Proline,boiler,122,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Proline,boiler,122,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Proline,boiler,122,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Proline,boiler,122,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Proline,boiler,122,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Proline,boiler,122,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Proline,boiler,122,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Proline,boiler,122,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -725,12 +949,17 @@ Proline,boiler,122,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor. Proline,boiler,122,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Proline,boiler,122,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Proline,boiler,122,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Proline,boiler,122,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Proline,boiler,122,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +Proline,boiler,122,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Proline,boiler,122,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Proline,boiler,122,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Proline,boiler,122,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Proline,boiler,122,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Proline,boiler,122,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -738,38 +967,38 @@ GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,rettemp,return temperature,ushor GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -783,6 +1012,7 @@ GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwtapactivated,turn on/off,boole GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -792,12 +1022,12 @@ GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcomfort1,comfort mode,enum [hi GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -816,12 +1046,17 @@ GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,ww3wayvalve,3-way valve active,b GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -GB212,boiler,131,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +GB212,boiler,131,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +GB212,boiler,131,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff GB212,boiler,131,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive GB212,boiler,131,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -GB212,boiler,131,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +GB212,boiler,131,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp GB212,boiler,131,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod GB212,boiler,131,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp GB212,boiler,131,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -829,38 +1064,38 @@ GB212,boiler,131,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.bo GB212,boiler,131,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp GB212,boiler,131,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress GB212,boiler,131,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +GB212,boiler,131,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp GB212,boiler,131,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp GB212,boiler,131,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas GB212,boiler,131,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 GB212,boiler,131,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -GB212,boiler,131,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump GB212,boiler,131,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork GB212,boiler,131,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork GB212,boiler,131,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +GB212,boiler,131,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +GB212,boiler,131,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +GB212,boiler,131,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +GB212,boiler,131,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +GB212,boiler,131,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +GB212,boiler,131,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +GB212,boiler,131,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff GB212,boiler,131,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -GB212,boiler,131,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +GB212,boiler,131,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +GB212,boiler,131,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump GB212,boiler,131,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax GB212,boiler,131,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin GB212,boiler,131,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -GB212,boiler,131,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -GB212,boiler,131,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -GB212,boiler,131,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -GB212,boiler,131,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -GB212,boiler,131,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -GB212,boiler,131,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -GB212,boiler,131,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -GB212,boiler,131,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +GB212,boiler,131,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay GB212,boiler,131,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp GB212,boiler,131,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -GB212,boiler,131,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow GB212,boiler,131,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow GB212,boiler,131,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -GB212,boiler,131,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -GB212,boiler,131,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -GB212,boiler,131,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -GB212,boiler,131,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -GB212,boiler,131,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -GB212,boiler,131,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +GB212,boiler,131,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +GB212,boiler,131,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +GB212,boiler,131,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +GB212,boiler,131,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +GB212,boiler,131,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +GB212,boiler,131,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime GB212,boiler,131,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode GB212,boiler,131,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode GB212,boiler,131,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -874,6 +1109,7 @@ GB212,boiler,131,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on GB212,boiler,131,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp GB212,boiler,131,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp GB212,boiler,131,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +GB212,boiler,131,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus GB212,boiler,131,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff GB212,boiler,131,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle GB212,boiler,131,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -883,12 +1119,12 @@ GB212,boiler,131,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select. GB212,boiler,131,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset GB212,boiler,131,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization GB212,boiler,131,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -GB212,boiler,131,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +GB212,boiler,131,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp GB212,boiler,131,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump GB212,boiler,131,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype GB212,boiler,131,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston GB212,boiler,131,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -GB212,boiler,131,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +GB212,boiler,131,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp GB212,boiler,131,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode GB212,boiler,131,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc GB212,boiler,131,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -907,12 +1143,17 @@ GB212,boiler,131,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.bo GB212,boiler,131,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower GB212,boiler,131,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp GB212,boiler,131,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -GB212,boiler,131,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -GB212,boiler,131,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -GC7000F,boiler,132,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +GB212,boiler,131,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +GB212,boiler,131,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +GB212,boiler,131,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +GB212,boiler,131,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +GB212,boiler,131,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +GB212,boiler,131,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +GC7000F,boiler,132,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +GC7000F,boiler,132,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff GC7000F,boiler,132,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive GC7000F,boiler,132,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -GC7000F,boiler,132,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +GC7000F,boiler,132,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp GC7000F,boiler,132,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod GC7000F,boiler,132,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp GC7000F,boiler,132,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -920,38 +1161,38 @@ GC7000F,boiler,132,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor. GC7000F,boiler,132,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp GC7000F,boiler,132,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress GC7000F,boiler,132,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +GC7000F,boiler,132,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp GC7000F,boiler,132,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp GC7000F,boiler,132,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas GC7000F,boiler,132,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 GC7000F,boiler,132,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -GC7000F,boiler,132,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump GC7000F,boiler,132,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork GC7000F,boiler,132,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork GC7000F,boiler,132,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +GC7000F,boiler,132,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +GC7000F,boiler,132,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +GC7000F,boiler,132,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +GC7000F,boiler,132,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +GC7000F,boiler,132,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +GC7000F,boiler,132,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +GC7000F,boiler,132,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff GC7000F,boiler,132,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -GC7000F,boiler,132,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +GC7000F,boiler,132,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +GC7000F,boiler,132,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump GC7000F,boiler,132,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax GC7000F,boiler,132,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin GC7000F,boiler,132,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -GC7000F,boiler,132,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -GC7000F,boiler,132,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -GC7000F,boiler,132,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -GC7000F,boiler,132,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -GC7000F,boiler,132,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -GC7000F,boiler,132,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -GC7000F,boiler,132,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -GC7000F,boiler,132,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +GC7000F,boiler,132,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay GC7000F,boiler,132,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp GC7000F,boiler,132,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -GC7000F,boiler,132,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow GC7000F,boiler,132,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow GC7000F,boiler,132,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -GC7000F,boiler,132,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -GC7000F,boiler,132,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -GC7000F,boiler,132,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -GC7000F,boiler,132,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -GC7000F,boiler,132,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -GC7000F,boiler,132,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +GC7000F,boiler,132,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +GC7000F,boiler,132,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +GC7000F,boiler,132,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +GC7000F,boiler,132,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +GC7000F,boiler,132,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +GC7000F,boiler,132,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime GC7000F,boiler,132,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode GC7000F,boiler,132,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode GC7000F,boiler,132,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -965,6 +1206,7 @@ GC7000F,boiler,132,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_ GC7000F,boiler,132,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp GC7000F,boiler,132,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp GC7000F,boiler,132,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +GC7000F,boiler,132,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus GC7000F,boiler,132,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff GC7000F,boiler,132,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle GC7000F,boiler,132,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -974,12 +1216,12 @@ GC7000F,boiler,132,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,selec GC7000F,boiler,132,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset GC7000F,boiler,132,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization GC7000F,boiler,132,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -GC7000F,boiler,132,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +GC7000F,boiler,132,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp GC7000F,boiler,132,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump GC7000F,boiler,132,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype GC7000F,boiler,132,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston GC7000F,boiler,132,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -GC7000F,boiler,132,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +GC7000F,boiler,132,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp GC7000F,boiler,132,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode GC7000F,boiler,132,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc GC7000F,boiler,132,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -998,12 +1240,17 @@ GC7000F,boiler,132,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor. GC7000F,boiler,132,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower GC7000F,boiler,132,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp GC7000F,boiler,132,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -GC7000F,boiler,132,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -GC7000F,boiler,132,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Logano GB125/KB195i/Logamatic MC110,boiler,133,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +GC7000F,boiler,132,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +GC7000F,boiler,132,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +GC7000F,boiler,132,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +GC7000F,boiler,132,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +GC7000F,boiler,132,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +GC7000F,boiler,132,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +Logano GB125/KB195i/Logamatic MC110,boiler,133,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Logano GB125/KB195i/Logamatic MC110,boiler,133,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Logano GB125/KB195i/Logamatic MC110,boiler,133,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Logano GB125/KB195i/Logamatic MC110,boiler,133,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Logano GB125/KB195i/Logamatic MC110,boiler,133,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -1011,38 +1258,38 @@ Logano GB125/KB195i/Logamatic MC110,boiler,133,rettemp,return temperature,ushort Logano GB125/KB195i/Logamatic MC110,boiler,133,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Logano GB125/KB195i/Logamatic MC110,boiler,133,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Logano GB125/KB195i/Logamatic MC110,boiler,133,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Logano GB125/KB195i/Logamatic MC110,boiler,133,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Logano GB125/KB195i/Logamatic MC110,boiler,133,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Logano GB125/KB195i/Logamatic MC110,boiler,133,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Logano GB125/KB195i/Logamatic MC110,boiler,133,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Logano GB125/KB195i/Logamatic MC110,boiler,133,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Logano GB125/KB195i/Logamatic MC110,boiler,133,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Logano GB125/KB195i/Logamatic MC110,boiler,133,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +Logano GB125/KB195i/Logamatic MC110,boiler,133,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Logano GB125/KB195i/Logamatic MC110,boiler,133,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Logano GB125/KB195i/Logamatic MC110,boiler,133,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Logano GB125/KB195i/Logamatic MC110,boiler,133,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Logano GB125/KB195i/Logamatic MC110,boiler,133,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Logano GB125/KB195i/Logamatic MC110,boiler,133,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Logano GB125/KB195i/Logamatic MC110,boiler,133,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Logano GB125/KB195i/Logamatic MC110,boiler,133,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Logano GB125/KB195i/Logamatic MC110,boiler,133,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Logano GB125/KB195i/Logamatic MC110,boiler,133,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Logano GB125/KB195i/Logamatic MC110,boiler,133,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Logano GB125/KB195i/Logamatic MC110,boiler,133,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Logano GB125/KB195i/Logamatic MC110,boiler,133,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Logano GB125/KB195i/Logamatic MC110,boiler,133,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Logano GB125/KB195i/Logamatic MC110,boiler,133,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Logano GB125/KB195i/Logamatic MC110,boiler,133,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Logano GB125/KB195i/Logamatic MC110,boiler,133,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Logano GB125/KB195i/Logamatic MC110,boiler,133,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Logano GB125/KB195i/Logamatic MC110,boiler,133,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Logano GB125/KB195i/Logamatic MC110,boiler,133,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Logano GB125/KB195i/Logamatic MC110,boiler,133,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Logano GB125/KB195i/Logamatic MC110,boiler,133,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Logano GB125/KB195i/Logamatic MC110,boiler,133,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Logano GB125/KB195i/Logamatic MC110,boiler,133,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Logano GB125/KB195i/Logamatic MC110,boiler,133,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Logano GB125/KB195i/Logamatic MC110,boiler,133,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Logano GB125/KB195i/Logamatic MC110,boiler,133,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Logano GB125/KB195i/Logamatic MC110,boiler,133,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Logano GB125/KB195i/Logamatic MC110,boiler,133,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Logano GB125/KB195i/Logamatic MC110,boiler,133,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Logano GB125/KB195i/Logamatic MC110,boiler,133,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Logano GB125/KB195i/Logamatic MC110,boiler,133,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Logano GB125/KB195i/Logamatic MC110,boiler,133,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Logano GB125/KB195i/Logamatic MC110,boiler,133,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -1056,6 +1303,7 @@ Logano GB125/KB195i/Logamatic MC110,boiler,133,wwtapactivated,turn on/off,boolea Logano GB125/KB195i/Logamatic MC110,boiler,133,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Logano GB125/KB195i/Logamatic MC110,boiler,133,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Logano GB125/KB195i/Logamatic MC110,boiler,133,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Logano GB125/KB195i/Logamatic MC110,boiler,133,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Logano GB125/KB195i/Logamatic MC110,boiler,133,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Logano GB125/KB195i/Logamatic MC110,boiler,133,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Logano GB125/KB195i/Logamatic MC110,boiler,133,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -1065,12 +1313,12 @@ Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcomfort1,comfort mode,enum [hig Logano GB125/KB195i/Logamatic MC110,boiler,133,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Logano GB125/KB195i/Logamatic MC110,boiler,133,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Logano GB125/KB195i/Logamatic MC110,boiler,133,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Logano GB125/KB195i/Logamatic MC110,boiler,133,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Logano GB125/KB195i/Logamatic MC110,boiler,133,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Logano GB125/KB195i/Logamatic MC110,boiler,133,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -1089,12 +1337,17 @@ Logano GB125/KB195i/Logamatic MC110,boiler,133,ww3wayvalve,3-way valve active,bo Logano GB125/KB195i/Logamatic MC110,boiler,133,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Logano GB125/KB195i/Logamatic MC110,boiler,133,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Greenstar 30Ri Compact,boiler,154,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +Logano GB125/KB195i/Logamatic MC110,boiler,133,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Logano GB125/KB195i/Logamatic MC110,boiler,133,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Logano GB125/KB195i/Logamatic MC110,boiler,133,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +Greenstar 30Ri Compact,boiler,154,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Greenstar 30Ri Compact,boiler,154,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Greenstar 30Ri Compact,boiler,154,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Greenstar 30Ri Compact,boiler,154,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Greenstar 30Ri Compact,boiler,154,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Greenstar 30Ri Compact,boiler,154,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Greenstar 30Ri Compact,boiler,154,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Greenstar 30Ri Compact,boiler,154,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Greenstar 30Ri Compact,boiler,154,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -1102,38 +1355,38 @@ Greenstar 30Ri Compact,boiler,154,rettemp,return temperature,ushort (>=0<=3199), Greenstar 30Ri Compact,boiler,154,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Greenstar 30Ri Compact,boiler,154,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Greenstar 30Ri Compact,boiler,154,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Greenstar 30Ri Compact,boiler,154,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Greenstar 30Ri Compact,boiler,154,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Greenstar 30Ri Compact,boiler,154,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Greenstar 30Ri Compact,boiler,154,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Greenstar 30Ri Compact,boiler,154,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Greenstar 30Ri Compact,boiler,154,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Greenstar 30Ri Compact,boiler,154,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Greenstar 30Ri Compact,boiler,154,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Greenstar 30Ri Compact,boiler,154,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +Greenstar 30Ri Compact,boiler,154,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Greenstar 30Ri Compact,boiler,154,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Greenstar 30Ri Compact,boiler,154,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Greenstar 30Ri Compact,boiler,154,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Greenstar 30Ri Compact,boiler,154,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Greenstar 30Ri Compact,boiler,154,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Greenstar 30Ri Compact,boiler,154,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Greenstar 30Ri Compact,boiler,154,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Greenstar 30Ri Compact,boiler,154,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Greenstar 30Ri Compact,boiler,154,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Greenstar 30Ri Compact,boiler,154,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Greenstar 30Ri Compact,boiler,154,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Greenstar 30Ri Compact,boiler,154,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Greenstar 30Ri Compact,boiler,154,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Greenstar 30Ri Compact,boiler,154,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Greenstar 30Ri Compact,boiler,154,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Greenstar 30Ri Compact,boiler,154,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Greenstar 30Ri Compact,boiler,154,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Greenstar 30Ri Compact,boiler,154,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Greenstar 30Ri Compact,boiler,154,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Greenstar 30Ri Compact,boiler,154,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Greenstar 30Ri Compact,boiler,154,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Greenstar 30Ri Compact,boiler,154,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Greenstar 30Ri Compact,boiler,154,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Greenstar 30Ri Compact,boiler,154,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Greenstar 30Ri Compact,boiler,154,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Greenstar 30Ri Compact,boiler,154,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Greenstar 30Ri Compact,boiler,154,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Greenstar 30Ri Compact,boiler,154,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Greenstar 30Ri Compact,boiler,154,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Greenstar 30Ri Compact,boiler,154,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Greenstar 30Ri Compact,boiler,154,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Greenstar 30Ri Compact,boiler,154,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Greenstar 30Ri Compact,boiler,154,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Greenstar 30Ri Compact,boiler,154,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Greenstar 30Ri Compact,boiler,154,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Greenstar 30Ri Compact,boiler,154,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Greenstar 30Ri Compact,boiler,154,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Greenstar 30Ri Compact,boiler,154,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Greenstar 30Ri Compact,boiler,154,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Greenstar 30Ri Compact,boiler,154,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Greenstar 30Ri Compact,boiler,154,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Greenstar 30Ri Compact,boiler,154,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -1147,6 +1400,7 @@ Greenstar 30Ri Compact,boiler,154,wwtapactivated,turn on/off,boolean, ,true,swit Greenstar 30Ri Compact,boiler,154,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Greenstar 30Ri Compact,boiler,154,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Greenstar 30Ri Compact,boiler,154,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Greenstar 30Ri Compact,boiler,154,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Greenstar 30Ri Compact,boiler,154,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Greenstar 30Ri Compact,boiler,154,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Greenstar 30Ri Compact,boiler,154,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -1156,12 +1410,12 @@ Greenstar 30Ri Compact,boiler,154,wwcomfort1,comfort mode,enum [high comfort\|ec Greenstar 30Ri Compact,boiler,154,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Greenstar 30Ri Compact,boiler,154,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Greenstar 30Ri Compact,boiler,154,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Greenstar 30Ri Compact,boiler,154,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Greenstar 30Ri Compact,boiler,154,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Greenstar 30Ri Compact,boiler,154,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Greenstar 30Ri Compact,boiler,154,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Greenstar 30Ri Compact,boiler,154,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Greenstar 30Ri Compact,boiler,154,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Greenstar 30Ri Compact,boiler,154,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Greenstar 30Ri Compact,boiler,154,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Greenstar 30Ri Compact,boiler,154,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Greenstar 30Ri Compact,boiler,154,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Greenstar 30Ri Compact,boiler,154,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -1180,12 +1434,17 @@ Greenstar 30Ri Compact,boiler,154,ww3wayvalve,3-way valve active,boolean, ,false Greenstar 30Ri Compact,boiler,154,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Greenstar 30Ri Compact,boiler,154,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Greenstar 30Ri Compact,boiler,154,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Greenstar 30Ri Compact,boiler,154,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Greenstar 30Ri Compact,boiler,154,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Cerapur Aero,boiler,167,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +Greenstar 30Ri Compact,boiler,154,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Greenstar 30Ri Compact,boiler,154,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Greenstar 30Ri Compact,boiler,154,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Greenstar 30Ri Compact,boiler,154,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Greenstar 30Ri Compact,boiler,154,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Greenstar 30Ri Compact,boiler,154,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +Cerapur Aero,boiler,167,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Cerapur Aero,boiler,167,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Cerapur Aero,boiler,167,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Cerapur Aero,boiler,167,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Cerapur Aero,boiler,167,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Cerapur Aero,boiler,167,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Cerapur Aero,boiler,167,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Cerapur Aero,boiler,167,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Cerapur Aero,boiler,167,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -1193,38 +1452,38 @@ Cerapur Aero,boiler,167,rettemp,return temperature,ushort (>=0<=3199),C,false,se Cerapur Aero,boiler,167,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Cerapur Aero,boiler,167,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Cerapur Aero,boiler,167,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Cerapur Aero,boiler,167,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Cerapur Aero,boiler,167,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Cerapur Aero,boiler,167,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Cerapur Aero,boiler,167,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Cerapur Aero,boiler,167,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Cerapur Aero,boiler,167,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Cerapur Aero,boiler,167,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Cerapur Aero,boiler,167,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Cerapur Aero,boiler,167,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +Cerapur Aero,boiler,167,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Cerapur Aero,boiler,167,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Cerapur Aero,boiler,167,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Cerapur Aero,boiler,167,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Cerapur Aero,boiler,167,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Cerapur Aero,boiler,167,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Cerapur Aero,boiler,167,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Cerapur Aero,boiler,167,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Cerapur Aero,boiler,167,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Cerapur Aero,boiler,167,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Cerapur Aero,boiler,167,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Cerapur Aero,boiler,167,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Cerapur Aero,boiler,167,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Cerapur Aero,boiler,167,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Cerapur Aero,boiler,167,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Cerapur Aero,boiler,167,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Cerapur Aero,boiler,167,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Cerapur Aero,boiler,167,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Cerapur Aero,boiler,167,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Cerapur Aero,boiler,167,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Cerapur Aero,boiler,167,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Cerapur Aero,boiler,167,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Cerapur Aero,boiler,167,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Cerapur Aero,boiler,167,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Cerapur Aero,boiler,167,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Cerapur Aero,boiler,167,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Cerapur Aero,boiler,167,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Cerapur Aero,boiler,167,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Cerapur Aero,boiler,167,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Cerapur Aero,boiler,167,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Cerapur Aero,boiler,167,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Cerapur Aero,boiler,167,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Cerapur Aero,boiler,167,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Cerapur Aero,boiler,167,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Cerapur Aero,boiler,167,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Cerapur Aero,boiler,167,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Cerapur Aero,boiler,167,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Cerapur Aero,boiler,167,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Cerapur Aero,boiler,167,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Cerapur Aero,boiler,167,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Cerapur Aero,boiler,167,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Cerapur Aero,boiler,167,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Cerapur Aero,boiler,167,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -1238,6 +1497,7 @@ Cerapur Aero,boiler,167,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_ Cerapur Aero,boiler,167,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Cerapur Aero,boiler,167,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Cerapur Aero,boiler,167,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Cerapur Aero,boiler,167,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Cerapur Aero,boiler,167,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Cerapur Aero,boiler,167,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Cerapur Aero,boiler,167,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -1247,12 +1507,12 @@ Cerapur Aero,boiler,167,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true, Cerapur Aero,boiler,167,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Cerapur Aero,boiler,167,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Cerapur Aero,boiler,167,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Cerapur Aero,boiler,167,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Cerapur Aero,boiler,167,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Cerapur Aero,boiler,167,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Cerapur Aero,boiler,167,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Cerapur Aero,boiler,167,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Cerapur Aero,boiler,167,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Cerapur Aero,boiler,167,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Cerapur Aero,boiler,167,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Cerapur Aero,boiler,167,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Cerapur Aero,boiler,167,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Cerapur Aero,boiler,167,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -1271,12 +1531,17 @@ Cerapur Aero,boiler,167,ww3wayvalve,3-way valve active,boolean, ,false,binary_se Cerapur Aero,boiler,167,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Cerapur Aero,boiler,167,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Cerapur Aero,boiler,167,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Cerapur Aero,boiler,167,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Cerapur Aero,boiler,167,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Hybrid Heatpump,boiler,168,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +Cerapur Aero,boiler,167,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Cerapur Aero,boiler,167,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Cerapur Aero,boiler,167,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Cerapur Aero,boiler,167,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Cerapur Aero,boiler,167,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Cerapur Aero,boiler,167,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +Hybrid Heatpump,boiler,168,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Hybrid Heatpump,boiler,168,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Hybrid Heatpump,boiler,168,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Hybrid Heatpump,boiler,168,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Hybrid Heatpump,boiler,168,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Hybrid Heatpump,boiler,168,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Hybrid Heatpump,boiler,168,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Hybrid Heatpump,boiler,168,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Hybrid Heatpump,boiler,168,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -1284,38 +1549,38 @@ Hybrid Heatpump,boiler,168,rettemp,return temperature,ushort (>=0<=3199),C,false Hybrid Heatpump,boiler,168,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Hybrid Heatpump,boiler,168,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Hybrid Heatpump,boiler,168,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Hybrid Heatpump,boiler,168,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Hybrid Heatpump,boiler,168,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Hybrid Heatpump,boiler,168,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Hybrid Heatpump,boiler,168,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Hybrid Heatpump,boiler,168,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Hybrid Heatpump,boiler,168,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Hybrid Heatpump,boiler,168,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Hybrid Heatpump,boiler,168,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Hybrid Heatpump,boiler,168,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +Hybrid Heatpump,boiler,168,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Hybrid Heatpump,boiler,168,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Hybrid Heatpump,boiler,168,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Hybrid Heatpump,boiler,168,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Hybrid Heatpump,boiler,168,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Hybrid Heatpump,boiler,168,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Hybrid Heatpump,boiler,168,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Hybrid Heatpump,boiler,168,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Hybrid Heatpump,boiler,168,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Hybrid Heatpump,boiler,168,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Hybrid Heatpump,boiler,168,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Hybrid Heatpump,boiler,168,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Hybrid Heatpump,boiler,168,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Hybrid Heatpump,boiler,168,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Hybrid Heatpump,boiler,168,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Hybrid Heatpump,boiler,168,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Hybrid Heatpump,boiler,168,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Hybrid Heatpump,boiler,168,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Hybrid Heatpump,boiler,168,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Hybrid Heatpump,boiler,168,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Hybrid Heatpump,boiler,168,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Hybrid Heatpump,boiler,168,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Hybrid Heatpump,boiler,168,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Hybrid Heatpump,boiler,168,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Hybrid Heatpump,boiler,168,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Hybrid Heatpump,boiler,168,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Hybrid Heatpump,boiler,168,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Hybrid Heatpump,boiler,168,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Hybrid Heatpump,boiler,168,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Hybrid Heatpump,boiler,168,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Hybrid Heatpump,boiler,168,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Hybrid Heatpump,boiler,168,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Hybrid Heatpump,boiler,168,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Hybrid Heatpump,boiler,168,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Hybrid Heatpump,boiler,168,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Hybrid Heatpump,boiler,168,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Hybrid Heatpump,boiler,168,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Hybrid Heatpump,boiler,168,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Hybrid Heatpump,boiler,168,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Hybrid Heatpump,boiler,168,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Hybrid Heatpump,boiler,168,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Hybrid Heatpump,boiler,168,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Hybrid Heatpump,boiler,168,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -1329,6 +1594,7 @@ Hybrid Heatpump,boiler,168,wwtapactivated,turn on/off,boolean, ,true,switch.boil Hybrid Heatpump,boiler,168,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Hybrid Heatpump,boiler,168,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Hybrid Heatpump,boiler,168,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Hybrid Heatpump,boiler,168,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Hybrid Heatpump,boiler,168,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Hybrid Heatpump,boiler,168,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Hybrid Heatpump,boiler,168,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -1338,12 +1604,12 @@ Hybrid Heatpump,boiler,168,wwcomfort1,comfort mode,enum [high comfort\|eco], ,tr Hybrid Heatpump,boiler,168,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Hybrid Heatpump,boiler,168,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Hybrid Heatpump,boiler,168,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Hybrid Heatpump,boiler,168,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Hybrid Heatpump,boiler,168,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Hybrid Heatpump,boiler,168,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Hybrid Heatpump,boiler,168,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Hybrid Heatpump,boiler,168,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Hybrid Heatpump,boiler,168,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Hybrid Heatpump,boiler,168,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Hybrid Heatpump,boiler,168,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Hybrid Heatpump,boiler,168,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Hybrid Heatpump,boiler,168,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Hybrid Heatpump,boiler,168,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -1362,12 +1628,17 @@ Hybrid Heatpump,boiler,168,ww3wayvalve,3-way valve active,boolean, ,false,binary Hybrid Heatpump,boiler,168,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Hybrid Heatpump,boiler,168,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Hybrid Heatpump,boiler,168,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Hybrid Heatpump,boiler,168,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Hybrid Heatpump,boiler,168,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Logano GB212,boiler,170,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +Hybrid Heatpump,boiler,168,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Hybrid Heatpump,boiler,168,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Hybrid Heatpump,boiler,168,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Hybrid Heatpump,boiler,168,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Hybrid Heatpump,boiler,168,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Hybrid Heatpump,boiler,168,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +Logano GB212,boiler,170,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Logano GB212,boiler,170,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logano GB212,boiler,170,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Logano GB212,boiler,170,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Logano GB212,boiler,170,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Logano GB212,boiler,170,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Logano GB212,boiler,170,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Logano GB212,boiler,170,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Logano GB212,boiler,170,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -1375,38 +1646,38 @@ Logano GB212,boiler,170,rettemp,return temperature,ushort (>=0<=3199),C,false,se Logano GB212,boiler,170,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Logano GB212,boiler,170,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Logano GB212,boiler,170,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Logano GB212,boiler,170,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Logano GB212,boiler,170,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Logano GB212,boiler,170,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Logano GB212,boiler,170,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Logano GB212,boiler,170,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Logano GB212,boiler,170,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Logano GB212,boiler,170,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Logano GB212,boiler,170,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Logano GB212,boiler,170,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +Logano GB212,boiler,170,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Logano GB212,boiler,170,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Logano GB212,boiler,170,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Logano GB212,boiler,170,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Logano GB212,boiler,170,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Logano GB212,boiler,170,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Logano GB212,boiler,170,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Logano GB212,boiler,170,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Logano GB212,boiler,170,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Logano GB212,boiler,170,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Logano GB212,boiler,170,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Logano GB212,boiler,170,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Logano GB212,boiler,170,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logano GB212,boiler,170,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Logano GB212,boiler,170,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Logano GB212,boiler,170,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Logano GB212,boiler,170,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Logano GB212,boiler,170,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Logano GB212,boiler,170,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Logano GB212,boiler,170,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Logano GB212,boiler,170,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Logano GB212,boiler,170,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Logano GB212,boiler,170,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Logano GB212,boiler,170,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Logano GB212,boiler,170,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Logano GB212,boiler,170,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Logano GB212,boiler,170,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Logano GB212,boiler,170,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Logano GB212,boiler,170,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Logano GB212,boiler,170,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Logano GB212,boiler,170,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Logano GB212,boiler,170,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Logano GB212,boiler,170,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Logano GB212,boiler,170,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Logano GB212,boiler,170,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Logano GB212,boiler,170,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Logano GB212,boiler,170,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Logano GB212,boiler,170,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Logano GB212,boiler,170,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Logano GB212,boiler,170,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Logano GB212,boiler,170,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Logano GB212,boiler,170,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Logano GB212,boiler,170,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -1420,6 +1691,7 @@ Logano GB212,boiler,170,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_ Logano GB212,boiler,170,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Logano GB212,boiler,170,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Logano GB212,boiler,170,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Logano GB212,boiler,170,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Logano GB212,boiler,170,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Logano GB212,boiler,170,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Logano GB212,boiler,170,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -1429,12 +1701,12 @@ Logano GB212,boiler,170,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true, Logano GB212,boiler,170,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Logano GB212,boiler,170,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Logano GB212,boiler,170,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Logano GB212,boiler,170,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Logano GB212,boiler,170,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Logano GB212,boiler,170,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Logano GB212,boiler,170,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Logano GB212,boiler,170,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Logano GB212,boiler,170,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Logano GB212,boiler,170,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Logano GB212,boiler,170,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Logano GB212,boiler,170,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Logano GB212,boiler,170,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Logano GB212,boiler,170,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -1453,12 +1725,17 @@ Logano GB212,boiler,170,ww3wayvalve,3-way valve active,boolean, ,false,binary_se Logano GB212,boiler,170,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Logano GB212,boiler,170,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Logano GB212,boiler,170,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Logano GB212,boiler,170,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Logano GB212,boiler,170,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +Logano GB212,boiler,170,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Logano GB212,boiler,170,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Logano GB212,boiler,170,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Logano GB212,boiler,170,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Logano GB212,boiler,170,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Logano GB212,boiler,170,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -1466,38 +1743,24 @@ Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,bo Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -1507,38 +1770,41 @@ Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,bo Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecontrol,total operating time heat,time (>=0<=17476),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecompheating,operating time compressor heating,time (>=0<=17476),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecompcooling,operating time compressor cooling,time (>=0<=17476),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecompww,operating time compressor dhw,time (>=0<=17476),minutes,false,sensor.boiler_operating_time_compressor_dhw,sensor.boiler_uptimecompww -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecomppool,operating time compressor pool,time (>=0<=17476),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,totalcompstarts,total compressor control starts,ulong (>=0<=65533), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingstarts,heating control starts,ulong (>=0<=65533), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,coolingstarts,cooling control starts,ulong (>=0<=65533), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwstarts2,control starts2,ulong (>=0<=65533), ,false,sensor.boiler_control_starts2,sensor.boiler_wwstarts2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,poolstarts,pool control starts,ulong (>=0<=65533), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconstotal,total energy consumption,ulong (>=0<=65533),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscomptotal,total energy consumption compressor,ulong (>=0<=65533),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompheating,energy consumption compressor heating,ulong (>=0<=65533),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompww,energy consumption compressor dhw,ulong (>=0<=65533),kWh,false,sensor.boiler_energy_consumption_compressor_dhw,sensor.boiler_nrgconscompww -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompcooling,energy consumption compressor cooling,ulong (>=0<=65533),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscomppool,energy consumption compressor pool,ulong (>=0<=65533),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconstotal,total aux elec. heater energy consumption,ulong (>=0<=65533),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,ulong (>=0<=65533),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconsww,aux elec. heater energy consumption dhw,ulong (>=0<=65533),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_dhw,sensor.boiler_auxelecheatnrgconsww -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconspool,aux elec. heater energy consumption pool,ulong (>=0<=65533),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsupptotal,total energy supplied,ulong (>=0<=65533),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppheating,total energy supplied heating,ulong (>=0<=65533),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppww,total energy warm supplied dhw,ulong (>=0<=65533),kWh,false,sensor.boiler_total_energy_warm_supplied_dhw,sensor.boiler_nrgsuppww -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppcooling,total energy supplied cooling,ulong (>=0<=65533),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsupppool,total energy supplied pool,ulong (>=0<=65533),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgww,energy,ulong (>=0<=167772),kWh,false,sensor.boiler_energy,sensor.boiler_nrgww +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgheat,energy heating,ulong (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,metertotal,meter total,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,metercomp,meter compressor,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,metereheat,meter e-heater,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecompww,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor,sensor.boiler_uptimecompww +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,totalcompstarts,total compressor control starts,ulong (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingstarts,heating control starts,ulong (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,coolingstarts,cooling control starts,ulong (>=0<=16777213), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwstarts2,control starts2,ulong (>=0<=16777213), ,false,sensor.boiler_control_starts2,sensor.boiler_wwstarts2 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,poolstarts,pool control starts,ulong (>=0<=16777213), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconstotal,total energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscomptotal,total energy consumption compressor,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompheating,energy consumption compressor heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompww,energy consumption compressor,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor,sensor.boiler_nrgconscompww +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompcooling,energy consumption compressor cooling,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscomppool,energy consumption compressor pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconstotal,total aux elec. heater energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconsww,aux elec. heater energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconsww +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconspool,aux elec. heater energy consumption pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsupptotal,total energy supplied,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppheating,total energy supplied heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppww,total energy warm supplied,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_warm_supplied,sensor.boiler_nrgsuppww +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppcooling,total energy supplied cooling,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsupppool,total energy supplied pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppower,compressor power output,uint (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpactivity,compressor activity,enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpheatingon,hp heating,boolean, ,false,binary_sensor.boiler_hp_heating,binary_sensor.boiler_hpheatingon -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcoolingon,hp cooling,boolean, ,false,binary_sensor.boiler_hp_cooling,binary_sensor.boiler_hpcoolingon -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpwwon,hp dhw,boolean, ,false,binary_sensor.boiler_hp_dhw,binary_sensor.boiler_hpwwon -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppoolon,hp pool,boolean, ,false,binary_sensor.boiler_hp_pool,binary_sensor.boiler_hppoolon Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpbrinepumpspd,brine pump speed,uint (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcompspd,compressor speed,uint (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd @@ -1557,14 +1823,17 @@ Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,bo Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptl2,air inlet temperature (TL2),short (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppl1,low pressure side temperature (PL1),short (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpph1,high pressure side temperature (PH1),short (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpta4,drain pan temp (TA4),short (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptw1,reservoir temp (TW1),short (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,poolsettemp,pool set temperature,uint (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxheatdhw,heat limit dhw,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_dhw,select.boiler_maxheatdhw +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxheatdhw,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit,select.boiler_maxheatdhw Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pvcooling,Cooling only with PV,boolean, ,true,switch.boiler_Cooling_only_with_PV,switch.boiler_pvcooling Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly @@ -1594,6 +1863,7 @@ Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,bo Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwalternatingop,alternating operation,boolean, ,true,switch.boiler_alternating_operation,switch.boiler_wwalternatingop Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwaltopprioheat,prioritise heating during dhw,uint (>=20<=120),minutes,true,number.boiler_prioritise_heating_during_dhw,number.boiler_wwaltopprioheat Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwaltopprioww,prioritise dhw during heating,uint (>=30<=120),minutes,true,number.boiler_prioritise_dhw_during_heating,number.boiler_wwaltopprioww @@ -1605,6 +1875,7 @@ Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,bo Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -1614,12 +1885,12 @@ Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,bo Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -1638,12 +1909,13 @@ Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,bo Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Geo 5xx,boiler,173,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Geo 5xx,boiler,173,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Geo 5xx,boiler,173,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Geo 5xx,boiler,173,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Geo 5xx,boiler,173,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Geo 5xx,boiler,173,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Geo 5xx,boiler,173,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Geo 5xx,boiler,173,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Geo 5xx,boiler,173,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Geo 5xx,boiler,173,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -1651,38 +1923,24 @@ Geo 5xx,boiler,173,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor. Geo 5xx,boiler,173,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Geo 5xx,boiler,173,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Geo 5xx,boiler,173,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Geo 5xx,boiler,173,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp -Geo 5xx,boiler,173,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas -Geo 5xx,boiler,173,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Geo 5xx,boiler,173,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Geo 5xx,boiler,173,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Geo 5xx,boiler,173,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork -Geo 5xx,boiler,173,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork -Geo 5xx,boiler,173,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +Geo 5xx,boiler,173,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Geo 5xx,boiler,173,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Geo 5xx,boiler,173,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Geo 5xx,boiler,173,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Geo 5xx,boiler,173,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Geo 5xx,boiler,173,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Geo 5xx,boiler,173,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Geo 5xx,boiler,173,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Geo 5xx,boiler,173,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Geo 5xx,boiler,173,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Geo 5xx,boiler,173,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Geo 5xx,boiler,173,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Geo 5xx,boiler,173,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Geo 5xx,boiler,173,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Geo 5xx,boiler,173,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Geo 5xx,boiler,173,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Geo 5xx,boiler,173,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Geo 5xx,boiler,173,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Geo 5xx,boiler,173,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Geo 5xx,boiler,173,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Geo 5xx,boiler,173,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Geo 5xx,boiler,173,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Geo 5xx,boiler,173,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Geo 5xx,boiler,173,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Geo 5xx,boiler,173,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Geo 5xx,boiler,173,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Geo 5xx,boiler,173,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Geo 5xx,boiler,173,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Geo 5xx,boiler,173,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Geo 5xx,boiler,173,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Geo 5xx,boiler,173,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Geo 5xx,boiler,173,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Geo 5xx,boiler,173,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Geo 5xx,boiler,173,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Geo 5xx,boiler,173,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Geo 5xx,boiler,173,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Geo 5xx,boiler,173,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -1692,38 +1950,41 @@ Geo 5xx,boiler,173,maintenancetime,time to next maintenance,ushort (>=0<=31999), Geo 5xx,boiler,173,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Geo 5xx,boiler,173,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Geo 5xx,boiler,173,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Geo 5xx,boiler,173,uptimecontrol,total operating time heat,time (>=0<=17476),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol -Geo 5xx,boiler,173,uptimecompheating,operating time compressor heating,time (>=0<=17476),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating -Geo 5xx,boiler,173,uptimecompcooling,operating time compressor cooling,time (>=0<=17476),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling -Geo 5xx,boiler,173,uptimecompww,operating time compressor dhw,time (>=0<=17476),minutes,false,sensor.boiler_operating_time_compressor_dhw,sensor.boiler_uptimecompww -Geo 5xx,boiler,173,uptimecomppool,operating time compressor pool,time (>=0<=17476),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool -Geo 5xx,boiler,173,totalcompstarts,total compressor control starts,ulong (>=0<=65533), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts -Geo 5xx,boiler,173,heatingstarts,heating control starts,ulong (>=0<=65533), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts -Geo 5xx,boiler,173,coolingstarts,cooling control starts,ulong (>=0<=65533), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts -Geo 5xx,boiler,173,wwstarts2,control starts2,ulong (>=0<=65533), ,false,sensor.boiler_control_starts2,sensor.boiler_wwstarts2 -Geo 5xx,boiler,173,poolstarts,pool control starts,ulong (>=0<=65533), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts -Geo 5xx,boiler,173,nrgconstotal,total energy consumption,ulong (>=0<=65533),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal -Geo 5xx,boiler,173,nrgconscomptotal,total energy consumption compressor,ulong (>=0<=65533),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal -Geo 5xx,boiler,173,nrgconscompheating,energy consumption compressor heating,ulong (>=0<=65533),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating -Geo 5xx,boiler,173,nrgconscompww,energy consumption compressor dhw,ulong (>=0<=65533),kWh,false,sensor.boiler_energy_consumption_compressor_dhw,sensor.boiler_nrgconscompww -Geo 5xx,boiler,173,nrgconscompcooling,energy consumption compressor cooling,ulong (>=0<=65533),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling -Geo 5xx,boiler,173,nrgconscomppool,energy consumption compressor pool,ulong (>=0<=65533),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool -Geo 5xx,boiler,173,auxelecheatnrgconstotal,total aux elec. heater energy consumption,ulong (>=0<=65533),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal -Geo 5xx,boiler,173,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,ulong (>=0<=65533),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating -Geo 5xx,boiler,173,auxelecheatnrgconsww,aux elec. heater energy consumption dhw,ulong (>=0<=65533),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_dhw,sensor.boiler_auxelecheatnrgconsww -Geo 5xx,boiler,173,auxelecheatnrgconspool,aux elec. heater energy consumption pool,ulong (>=0<=65533),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool -Geo 5xx,boiler,173,nrgsupptotal,total energy supplied,ulong (>=0<=65533),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal -Geo 5xx,boiler,173,nrgsuppheating,total energy supplied heating,ulong (>=0<=65533),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating -Geo 5xx,boiler,173,nrgsuppww,total energy warm supplied dhw,ulong (>=0<=65533),kWh,false,sensor.boiler_total_energy_warm_supplied_dhw,sensor.boiler_nrgsuppww -Geo 5xx,boiler,173,nrgsuppcooling,total energy supplied cooling,ulong (>=0<=65533),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling -Geo 5xx,boiler,173,nrgsupppool,total energy supplied pool,ulong (>=0<=65533),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool +Geo 5xx,boiler,173,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Geo 5xx,boiler,173,nrgww,energy,ulong (>=0<=167772),kWh,false,sensor.boiler_energy,sensor.boiler_nrgww +Geo 5xx,boiler,173,nrgheat,energy heating,ulong (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat +Geo 5xx,boiler,173,metertotal,meter total,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal +Geo 5xx,boiler,173,metercomp,meter compressor,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp +Geo 5xx,boiler,173,metereheat,meter e-heater,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat +Geo 5xx,boiler,173,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal +Geo 5xx,boiler,173,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol +Geo 5xx,boiler,173,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating +Geo 5xx,boiler,173,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling +Geo 5xx,boiler,173,uptimecompww,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor,sensor.boiler_uptimecompww +Geo 5xx,boiler,173,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool +Geo 5xx,boiler,173,totalcompstarts,total compressor control starts,ulong (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts +Geo 5xx,boiler,173,heatingstarts,heating control starts,ulong (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts +Geo 5xx,boiler,173,coolingstarts,cooling control starts,ulong (>=0<=16777213), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts +Geo 5xx,boiler,173,wwstarts2,control starts2,ulong (>=0<=16777213), ,false,sensor.boiler_control_starts2,sensor.boiler_wwstarts2 +Geo 5xx,boiler,173,poolstarts,pool control starts,ulong (>=0<=16777213), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts +Geo 5xx,boiler,173,nrgconstotal,total energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal +Geo 5xx,boiler,173,nrgconscomptotal,total energy consumption compressor,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal +Geo 5xx,boiler,173,nrgconscompheating,energy consumption compressor heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating +Geo 5xx,boiler,173,nrgconscompww,energy consumption compressor,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor,sensor.boiler_nrgconscompww +Geo 5xx,boiler,173,nrgconscompcooling,energy consumption compressor cooling,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling +Geo 5xx,boiler,173,nrgconscomppool,energy consumption compressor pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool +Geo 5xx,boiler,173,auxelecheatnrgconstotal,total aux elec. heater energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal +Geo 5xx,boiler,173,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating +Geo 5xx,boiler,173,auxelecheatnrgconsww,aux elec. heater energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconsww +Geo 5xx,boiler,173,auxelecheatnrgconspool,aux elec. heater energy consumption pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool +Geo 5xx,boiler,173,nrgsupptotal,total energy supplied,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal +Geo 5xx,boiler,173,nrgsuppheating,total energy supplied heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating +Geo 5xx,boiler,173,nrgsuppww,total energy warm supplied,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_warm_supplied,sensor.boiler_nrgsuppww +Geo 5xx,boiler,173,nrgsuppcooling,total energy supplied cooling,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling +Geo 5xx,boiler,173,nrgsupppool,total energy supplied pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool Geo 5xx,boiler,173,hppower,compressor power output,uint (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower Geo 5xx,boiler,173,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon Geo 5xx,boiler,173,hpactivity,compressor activity,enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity -Geo 5xx,boiler,173,hpheatingon,hp heating,boolean, ,false,binary_sensor.boiler_hp_heating,binary_sensor.boiler_hpheatingon -Geo 5xx,boiler,173,hpcoolingon,hp cooling,boolean, ,false,binary_sensor.boiler_hp_cooling,binary_sensor.boiler_hpcoolingon -Geo 5xx,boiler,173,hpwwon,hp dhw,boolean, ,false,binary_sensor.boiler_hp_dhw,binary_sensor.boiler_hpwwon -Geo 5xx,boiler,173,hppoolon,hp pool,boolean, ,false,binary_sensor.boiler_hp_pool,binary_sensor.boiler_hppoolon Geo 5xx,boiler,173,hpbrinepumpspd,brine pump speed,uint (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd Geo 5xx,boiler,173,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve Geo 5xx,boiler,173,hpcompspd,compressor speed,uint (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd @@ -1742,14 +2003,17 @@ Geo 5xx,boiler,173,hptr7,refrigerant temperature gas side (condenser input) (TR7 Geo 5xx,boiler,173,hptl2,air inlet temperature (TL2),short (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2 Geo 5xx,boiler,173,hppl1,low pressure side temperature (PL1),short (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1 Geo 5xx,boiler,173,hpph1,high pressure side temperature (PH1),short (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1 +Geo 5xx,boiler,173,hpta4,drain pan temp (TA4),short (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4 +Geo 5xx,boiler,173,hptw1,reservoir temp (TW1),short (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1 Geo 5xx,boiler,173,poolsettemp,pool set temperature,uint (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp +Geo 5xx,boiler,173,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way Geo 5xx,boiler,173,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt Geo 5xx,boiler,173,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt Geo 5xx,boiler,173,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt Geo 5xx,boiler,173,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt Geo 5xx,boiler,173,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp Geo 5xx,boiler,173,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat -Geo 5xx,boiler,173,maxheatdhw,heat limit dhw,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_dhw,select.boiler_maxheatdhw +Geo 5xx,boiler,173,maxheatdhw,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit,select.boiler_maxheatdhw Geo 5xx,boiler,173,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost Geo 5xx,boiler,173,pvcooling,Cooling only with PV,boolean, ,true,switch.boiler_Cooling_only_with_PV,switch.boiler_pvcooling Geo 5xx,boiler,173,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly @@ -1779,6 +2043,7 @@ Geo 5xx,boiler,173,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,s Geo 5xx,boiler,173,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1 Geo 5xx,boiler,173,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2 Geo 5xx,boiler,173,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3 +Geo 5xx,boiler,173,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0 Geo 5xx,boiler,173,wwalternatingop,alternating operation,boolean, ,true,switch.boiler_alternating_operation,switch.boiler_wwalternatingop Geo 5xx,boiler,173,wwaltopprioheat,prioritise heating during dhw,uint (>=20<=120),minutes,true,number.boiler_prioritise_heating_during_dhw,number.boiler_wwaltopprioheat Geo 5xx,boiler,173,wwaltopprioww,prioritise dhw during heating,uint (>=30<=120),minutes,true,number.boiler_prioritise_dhw_during_heating,number.boiler_wwaltopprioww @@ -1790,6 +2055,7 @@ Geo 5xx,boiler,173,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_ Geo 5xx,boiler,173,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Geo 5xx,boiler,173,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Geo 5xx,boiler,173,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Geo 5xx,boiler,173,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Geo 5xx,boiler,173,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Geo 5xx,boiler,173,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Geo 5xx,boiler,173,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -1799,12 +2065,12 @@ Geo 5xx,boiler,173,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,selec Geo 5xx,boiler,173,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Geo 5xx,boiler,173,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Geo 5xx,boiler,173,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Geo 5xx,boiler,173,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Geo 5xx,boiler,173,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Geo 5xx,boiler,173,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Geo 5xx,boiler,173,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Geo 5xx,boiler,173,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Geo 5xx,boiler,173,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Geo 5xx,boiler,173,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Geo 5xx,boiler,173,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Geo 5xx,boiler,173,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Geo 5xx,boiler,173,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Geo 5xx,boiler,173,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -1823,103 +2089,110 @@ Geo 5xx,boiler,173,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor. Geo 5xx,boiler,173,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Geo 5xx,boiler,173,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Geo 5xx,boiler,173,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Geo 5xx,boiler,173,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Geo 5xx,boiler,173,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Condens 5000i/Greenstar 8000/GC9800IW,boiler,195,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Logamax U122/Cerapur,boiler,203,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +Geo 5xx,boiler,173,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Geo 5xx,boiler,173,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +Logamax U122/Cerapur,boiler,203,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Logamax U122/Cerapur,boiler,203,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logamax U122/Cerapur,boiler,203,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Logamax U122/Cerapur,boiler,203,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Logamax U122/Cerapur,boiler,203,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Logamax U122/Cerapur,boiler,203,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Logamax U122/Cerapur,boiler,203,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Logamax U122/Cerapur,boiler,203,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Logamax U122/Cerapur,boiler,203,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -1927,38 +2200,38 @@ Logamax U122/Cerapur,boiler,203,rettemp,return temperature,ushort (>=0<=3199),C, Logamax U122/Cerapur,boiler,203,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Logamax U122/Cerapur,boiler,203,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Logamax U122/Cerapur,boiler,203,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Logamax U122/Cerapur,boiler,203,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Logamax U122/Cerapur,boiler,203,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Logamax U122/Cerapur,boiler,203,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Logamax U122/Cerapur,boiler,203,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Logamax U122/Cerapur,boiler,203,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Logamax U122/Cerapur,boiler,203,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Logamax U122/Cerapur,boiler,203,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Logamax U122/Cerapur,boiler,203,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Logamax U122/Cerapur,boiler,203,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +Logamax U122/Cerapur,boiler,203,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Logamax U122/Cerapur,boiler,203,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Logamax U122/Cerapur,boiler,203,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Logamax U122/Cerapur,boiler,203,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Logamax U122/Cerapur,boiler,203,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Logamax U122/Cerapur,boiler,203,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Logamax U122/Cerapur,boiler,203,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Logamax U122/Cerapur,boiler,203,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Logamax U122/Cerapur,boiler,203,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Logamax U122/Cerapur,boiler,203,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Logamax U122/Cerapur,boiler,203,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Logamax U122/Cerapur,boiler,203,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Logamax U122/Cerapur,boiler,203,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logamax U122/Cerapur,boiler,203,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Logamax U122/Cerapur,boiler,203,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Logamax U122/Cerapur,boiler,203,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Logamax U122/Cerapur,boiler,203,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Logamax U122/Cerapur,boiler,203,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Logamax U122/Cerapur,boiler,203,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Logamax U122/Cerapur,boiler,203,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Logamax U122/Cerapur,boiler,203,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Logamax U122/Cerapur,boiler,203,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Logamax U122/Cerapur,boiler,203,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Logamax U122/Cerapur,boiler,203,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Logamax U122/Cerapur,boiler,203,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Logamax U122/Cerapur,boiler,203,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Logamax U122/Cerapur,boiler,203,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Logamax U122/Cerapur,boiler,203,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Logamax U122/Cerapur,boiler,203,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Logamax U122/Cerapur,boiler,203,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Logamax U122/Cerapur,boiler,203,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Logamax U122/Cerapur,boiler,203,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Logamax U122/Cerapur,boiler,203,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Logamax U122/Cerapur,boiler,203,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Logamax U122/Cerapur,boiler,203,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Logamax U122/Cerapur,boiler,203,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Logamax U122/Cerapur,boiler,203,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Logamax U122/Cerapur,boiler,203,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Logamax U122/Cerapur,boiler,203,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Logamax U122/Cerapur,boiler,203,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Logamax U122/Cerapur,boiler,203,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Logamax U122/Cerapur,boiler,203,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Logamax U122/Cerapur,boiler,203,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -1972,6 +2245,7 @@ Logamax U122/Cerapur,boiler,203,wwtapactivated,turn on/off,boolean, ,true,switch Logamax U122/Cerapur,boiler,203,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Logamax U122/Cerapur,boiler,203,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Logamax U122/Cerapur,boiler,203,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Logamax U122/Cerapur,boiler,203,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Logamax U122/Cerapur,boiler,203,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Logamax U122/Cerapur,boiler,203,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Logamax U122/Cerapur,boiler,203,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -1981,12 +2255,12 @@ Logamax U122/Cerapur,boiler,203,wwcomfort1,comfort mode,enum [high comfort\|eco] Logamax U122/Cerapur,boiler,203,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Logamax U122/Cerapur,boiler,203,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Logamax U122/Cerapur,boiler,203,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Logamax U122/Cerapur,boiler,203,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Logamax U122/Cerapur,boiler,203,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Logamax U122/Cerapur,boiler,203,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Logamax U122/Cerapur,boiler,203,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Logamax U122/Cerapur,boiler,203,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Logamax U122/Cerapur,boiler,203,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Logamax U122/Cerapur,boiler,203,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Logamax U122/Cerapur,boiler,203,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Logamax U122/Cerapur,boiler,203,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Logamax U122/Cerapur,boiler,203,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Logamax U122/Cerapur,boiler,203,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -2005,12 +2279,17 @@ Logamax U122/Cerapur,boiler,203,ww3wayvalve,3-way valve active,boolean, ,false,b Logamax U122/Cerapur,boiler,203,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Logamax U122/Cerapur,boiler,203,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Logamax U122/Cerapur,boiler,203,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Logamax U122/Cerapur,boiler,203,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Logamax U122/Cerapur,boiler,203,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Ecomline Excellent,boiler,206,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +Logamax U122/Cerapur,boiler,203,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Logamax U122/Cerapur,boiler,203,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Logamax U122/Cerapur,boiler,203,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Logamax U122/Cerapur,boiler,203,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Logamax U122/Cerapur,boiler,203,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Logamax U122/Cerapur,boiler,203,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +Ecomline Excellent,boiler,206,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Ecomline Excellent,boiler,206,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Ecomline Excellent,boiler,206,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Ecomline Excellent,boiler,206,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Ecomline Excellent,boiler,206,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Ecomline Excellent,boiler,206,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Ecomline Excellent,boiler,206,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Ecomline Excellent,boiler,206,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Ecomline Excellent,boiler,206,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -2018,38 +2297,38 @@ Ecomline Excellent,boiler,206,rettemp,return temperature,ushort (>=0<=3199),C,fa Ecomline Excellent,boiler,206,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Ecomline Excellent,boiler,206,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Ecomline Excellent,boiler,206,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Ecomline Excellent,boiler,206,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Ecomline Excellent,boiler,206,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Ecomline Excellent,boiler,206,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Ecomline Excellent,boiler,206,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Ecomline Excellent,boiler,206,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Ecomline Excellent,boiler,206,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Ecomline Excellent,boiler,206,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Ecomline Excellent,boiler,206,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Ecomline Excellent,boiler,206,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +Ecomline Excellent,boiler,206,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Ecomline Excellent,boiler,206,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Ecomline Excellent,boiler,206,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Ecomline Excellent,boiler,206,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Ecomline Excellent,boiler,206,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Ecomline Excellent,boiler,206,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Ecomline Excellent,boiler,206,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Ecomline Excellent,boiler,206,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Ecomline Excellent,boiler,206,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Ecomline Excellent,boiler,206,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Ecomline Excellent,boiler,206,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Ecomline Excellent,boiler,206,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Ecomline Excellent,boiler,206,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Ecomline Excellent,boiler,206,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Ecomline Excellent,boiler,206,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Ecomline Excellent,boiler,206,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Ecomline Excellent,boiler,206,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Ecomline Excellent,boiler,206,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Ecomline Excellent,boiler,206,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Ecomline Excellent,boiler,206,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Ecomline Excellent,boiler,206,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Ecomline Excellent,boiler,206,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Ecomline Excellent,boiler,206,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Ecomline Excellent,boiler,206,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Ecomline Excellent,boiler,206,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Ecomline Excellent,boiler,206,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Ecomline Excellent,boiler,206,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Ecomline Excellent,boiler,206,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Ecomline Excellent,boiler,206,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Ecomline Excellent,boiler,206,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Ecomline Excellent,boiler,206,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Ecomline Excellent,boiler,206,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Ecomline Excellent,boiler,206,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Ecomline Excellent,boiler,206,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Ecomline Excellent,boiler,206,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Ecomline Excellent,boiler,206,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Ecomline Excellent,boiler,206,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Ecomline Excellent,boiler,206,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Ecomline Excellent,boiler,206,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Ecomline Excellent,boiler,206,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Ecomline Excellent,boiler,206,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Ecomline Excellent,boiler,206,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Ecomline Excellent,boiler,206,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -2063,6 +2342,7 @@ Ecomline Excellent,boiler,206,wwtapactivated,turn on/off,boolean, ,true,switch.b Ecomline Excellent,boiler,206,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Ecomline Excellent,boiler,206,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Ecomline Excellent,boiler,206,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Ecomline Excellent,boiler,206,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Ecomline Excellent,boiler,206,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Ecomline Excellent,boiler,206,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Ecomline Excellent,boiler,206,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -2072,12 +2352,12 @@ Ecomline Excellent,boiler,206,wwcomfort1,comfort mode,enum [high comfort\|eco], Ecomline Excellent,boiler,206,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Ecomline Excellent,boiler,206,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Ecomline Excellent,boiler,206,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Ecomline Excellent,boiler,206,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Ecomline Excellent,boiler,206,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Ecomline Excellent,boiler,206,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Ecomline Excellent,boiler,206,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Ecomline Excellent,boiler,206,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Ecomline Excellent,boiler,206,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Ecomline Excellent,boiler,206,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Ecomline Excellent,boiler,206,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Ecomline Excellent,boiler,206,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Ecomline Excellent,boiler,206,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Ecomline Excellent,boiler,206,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -2096,12 +2376,17 @@ Ecomline Excellent,boiler,206,ww3wayvalve,3-way valve active,boolean, ,false,bin Ecomline Excellent,boiler,206,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Ecomline Excellent,boiler,206,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Ecomline Excellent,boiler,206,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Ecomline Excellent,boiler,206,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Ecomline Excellent,boiler,206,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +Ecomline Excellent,boiler,206,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Ecomline Excellent,boiler,206,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Ecomline Excellent,boiler,206,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Ecomline Excellent,boiler,206,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Ecomline Excellent,boiler,206,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Ecomline Excellent,boiler,206,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -2109,38 +2394,38 @@ Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,rettemp,return temper Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -2154,6 +2439,7 @@ Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwtapactivated,turn o Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -2163,12 +2449,12 @@ Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcomfort1,comfort mo Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -2187,12 +2473,17 @@ Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,ww3wayvalve,3-way val Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Cascade MC400,boiler,210,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +Cascade MC400,boiler,210,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Cascade MC400,boiler,210,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Cascade MC400,boiler,210,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Cascade MC400,boiler,210,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Cascade MC400,boiler,210,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Cascade MC400,boiler,210,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Cascade MC400,boiler,210,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Cascade MC400,boiler,210,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Cascade MC400,boiler,210,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -2200,38 +2491,38 @@ Cascade MC400,boiler,210,rettemp,return temperature,ushort (>=0<=3199),C,false,s Cascade MC400,boiler,210,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Cascade MC400,boiler,210,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Cascade MC400,boiler,210,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Cascade MC400,boiler,210,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Cascade MC400,boiler,210,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Cascade MC400,boiler,210,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Cascade MC400,boiler,210,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Cascade MC400,boiler,210,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Cascade MC400,boiler,210,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Cascade MC400,boiler,210,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Cascade MC400,boiler,210,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Cascade MC400,boiler,210,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +Cascade MC400,boiler,210,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Cascade MC400,boiler,210,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Cascade MC400,boiler,210,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Cascade MC400,boiler,210,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Cascade MC400,boiler,210,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Cascade MC400,boiler,210,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Cascade MC400,boiler,210,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Cascade MC400,boiler,210,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Cascade MC400,boiler,210,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Cascade MC400,boiler,210,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Cascade MC400,boiler,210,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Cascade MC400,boiler,210,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Cascade MC400,boiler,210,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Cascade MC400,boiler,210,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Cascade MC400,boiler,210,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Cascade MC400,boiler,210,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Cascade MC400,boiler,210,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Cascade MC400,boiler,210,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Cascade MC400,boiler,210,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Cascade MC400,boiler,210,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Cascade MC400,boiler,210,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Cascade MC400,boiler,210,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Cascade MC400,boiler,210,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Cascade MC400,boiler,210,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Cascade MC400,boiler,210,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Cascade MC400,boiler,210,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Cascade MC400,boiler,210,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Cascade MC400,boiler,210,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Cascade MC400,boiler,210,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Cascade MC400,boiler,210,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Cascade MC400,boiler,210,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Cascade MC400,boiler,210,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Cascade MC400,boiler,210,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Cascade MC400,boiler,210,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Cascade MC400,boiler,210,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Cascade MC400,boiler,210,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Cascade MC400,boiler,210,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Cascade MC400,boiler,210,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Cascade MC400,boiler,210,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Cascade MC400,boiler,210,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Cascade MC400,boiler,210,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Cascade MC400,boiler,210,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Cascade MC400,boiler,210,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -2245,6 +2536,7 @@ Cascade MC400,boiler,210,wwtapactivated,turn on/off,boolean, ,true,switch.boiler Cascade MC400,boiler,210,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Cascade MC400,boiler,210,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Cascade MC400,boiler,210,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Cascade MC400,boiler,210,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Cascade MC400,boiler,210,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Cascade MC400,boiler,210,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Cascade MC400,boiler,210,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -2254,12 +2546,12 @@ Cascade MC400,boiler,210,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true Cascade MC400,boiler,210,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Cascade MC400,boiler,210,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Cascade MC400,boiler,210,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Cascade MC400,boiler,210,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Cascade MC400,boiler,210,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Cascade MC400,boiler,210,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Cascade MC400,boiler,210,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Cascade MC400,boiler,210,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Cascade MC400,boiler,210,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Cascade MC400,boiler,210,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Cascade MC400,boiler,210,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Cascade MC400,boiler,210,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Cascade MC400,boiler,210,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Cascade MC400,boiler,210,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -2278,12 +2570,17 @@ Cascade MC400,boiler,210,ww3wayvalve,3-way valve active,boolean, ,false,binary_s Cascade MC400,boiler,210,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Cascade MC400,boiler,210,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Cascade MC400,boiler,210,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Cascade MC400,boiler,210,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Cascade MC400,boiler,210,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -EasyControl Adapter,boiler,211,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +Cascade MC400,boiler,210,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Cascade MC400,boiler,210,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Cascade MC400,boiler,210,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Cascade MC400,boiler,210,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Cascade MC400,boiler,210,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Cascade MC400,boiler,210,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +EasyControl Adapter,boiler,211,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +EasyControl Adapter,boiler,211,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff EasyControl Adapter,boiler,211,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive EasyControl Adapter,boiler,211,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -EasyControl Adapter,boiler,211,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +EasyControl Adapter,boiler,211,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp EasyControl Adapter,boiler,211,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod EasyControl Adapter,boiler,211,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp EasyControl Adapter,boiler,211,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -2291,38 +2588,38 @@ EasyControl Adapter,boiler,211,rettemp,return temperature,ushort (>=0<=3199),C,f EasyControl Adapter,boiler,211,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp EasyControl Adapter,boiler,211,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress EasyControl Adapter,boiler,211,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +EasyControl Adapter,boiler,211,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp EasyControl Adapter,boiler,211,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp EasyControl Adapter,boiler,211,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas EasyControl Adapter,boiler,211,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 EasyControl Adapter,boiler,211,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -EasyControl Adapter,boiler,211,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump EasyControl Adapter,boiler,211,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork EasyControl Adapter,boiler,211,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork EasyControl Adapter,boiler,211,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +EasyControl Adapter,boiler,211,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +EasyControl Adapter,boiler,211,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +EasyControl Adapter,boiler,211,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +EasyControl Adapter,boiler,211,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +EasyControl Adapter,boiler,211,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +EasyControl Adapter,boiler,211,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +EasyControl Adapter,boiler,211,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff EasyControl Adapter,boiler,211,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -EasyControl Adapter,boiler,211,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +EasyControl Adapter,boiler,211,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +EasyControl Adapter,boiler,211,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump EasyControl Adapter,boiler,211,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax EasyControl Adapter,boiler,211,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin EasyControl Adapter,boiler,211,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -EasyControl Adapter,boiler,211,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -EasyControl Adapter,boiler,211,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -EasyControl Adapter,boiler,211,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -EasyControl Adapter,boiler,211,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -EasyControl Adapter,boiler,211,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -EasyControl Adapter,boiler,211,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -EasyControl Adapter,boiler,211,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -EasyControl Adapter,boiler,211,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +EasyControl Adapter,boiler,211,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay EasyControl Adapter,boiler,211,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp EasyControl Adapter,boiler,211,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -EasyControl Adapter,boiler,211,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow EasyControl Adapter,boiler,211,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow EasyControl Adapter,boiler,211,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -EasyControl Adapter,boiler,211,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -EasyControl Adapter,boiler,211,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -EasyControl Adapter,boiler,211,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -EasyControl Adapter,boiler,211,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -EasyControl Adapter,boiler,211,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -EasyControl Adapter,boiler,211,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +EasyControl Adapter,boiler,211,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +EasyControl Adapter,boiler,211,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +EasyControl Adapter,boiler,211,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +EasyControl Adapter,boiler,211,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +EasyControl Adapter,boiler,211,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +EasyControl Adapter,boiler,211,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime EasyControl Adapter,boiler,211,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode EasyControl Adapter,boiler,211,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode EasyControl Adapter,boiler,211,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -2336,6 +2633,7 @@ EasyControl Adapter,boiler,211,wwtapactivated,turn on/off,boolean, ,true,switch. EasyControl Adapter,boiler,211,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp EasyControl Adapter,boiler,211,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp EasyControl Adapter,boiler,211,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +EasyControl Adapter,boiler,211,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus EasyControl Adapter,boiler,211,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff EasyControl Adapter,boiler,211,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle EasyControl Adapter,boiler,211,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -2345,12 +2643,12 @@ EasyControl Adapter,boiler,211,wwcomfort1,comfort mode,enum [high comfort\|eco], EasyControl Adapter,boiler,211,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset EasyControl Adapter,boiler,211,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization EasyControl Adapter,boiler,211,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -EasyControl Adapter,boiler,211,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +EasyControl Adapter,boiler,211,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp EasyControl Adapter,boiler,211,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump EasyControl Adapter,boiler,211,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype EasyControl Adapter,boiler,211,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston EasyControl Adapter,boiler,211,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -EasyControl Adapter,boiler,211,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +EasyControl Adapter,boiler,211,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp EasyControl Adapter,boiler,211,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode EasyControl Adapter,boiler,211,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc EasyControl Adapter,boiler,211,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -2369,107 +2667,103 @@ EasyControl Adapter,boiler,211,ww3wayvalve,3-way valve active,boolean, ,false,bi EasyControl Adapter,boiler,211,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower EasyControl Adapter,boiler,211,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp EasyControl Adapter,boiler,211,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -EasyControl Adapter,boiler,211,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -EasyControl Adapter,boiler,211,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Greenstar HIU,boiler,219,keepwarmtemp,keep warm temperature,uint (>=0<=254),C,true,number.boiler_keep_warm_temperature,number.boiler_keepwarmtemp -Greenstar HIU,boiler,219,setreturntemp,set temp return,uint (>=0<=254),C,true,number.boiler_set_temp_return,number.boiler_setreturntemp -Greenstar HIU,boiler,219,cwflowrate,cold water flow rate,ushort (>=0<=31999),l/min,false,sensor.boiler_cold_water_flow_rate,sensor.boiler_cwflowrate -Greenstar HIU,boiler,219,netflowtemp,heat network flow temp,ushort (>=0<=31999),C,false,sensor.boiler_heat_network_flow_temp,sensor.boiler_netflowtemp -Greenstar HIU,boiler,219,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset -Greenstar HIU,boiler,219,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive -Greenstar HIU,boiler,219,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Greenstar HIU,boiler,219,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Greenstar HIU,boiler,219,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Greenstar HIU,boiler,219,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Greenstar HIU,boiler,219,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Greenstar HIU,boiler,219,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Greenstar HIU,boiler,219,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Greenstar HIU,boiler,219,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Greenstar HIU,boiler,219,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Greenstar HIU,boiler,219,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp -Greenstar HIU,boiler,219,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas -Greenstar HIU,boiler,219,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Greenstar HIU,boiler,219,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Greenstar HIU,boiler,219,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Greenstar HIU,boiler,219,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork -Greenstar HIU,boiler,219,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork -Greenstar HIU,boiler,219,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -Greenstar HIU,boiler,219,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Greenstar HIU,boiler,219,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp -Greenstar HIU,boiler,219,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Greenstar HIU,boiler,219,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin -Greenstar HIU,boiler,219,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Greenstar HIU,boiler,219,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Greenstar HIU,boiler,219,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Greenstar HIU,boiler,219,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Greenstar HIU,boiler,219,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Greenstar HIU,boiler,219,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Greenstar HIU,boiler,219,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Greenstar HIU,boiler,219,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Greenstar HIU,boiler,219,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff -Greenstar HIU,boiler,219,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Greenstar HIU,boiler,219,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Greenstar HIU,boiler,219,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -Greenstar HIU,boiler,219,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Greenstar HIU,boiler,219,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Greenstar HIU,boiler,219,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Greenstar HIU,boiler,219,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Greenstar HIU,boiler,219,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Greenstar HIU,boiler,219,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Greenstar HIU,boiler,219,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Greenstar HIU,boiler,219,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime -Greenstar HIU,boiler,219,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode -Greenstar HIU,boiler,219,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Greenstar HIU,boiler,219,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber -Greenstar HIU,boiler,219,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage -Greenstar HIU,boiler,219,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Greenstar HIU,boiler,219,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime -Greenstar HIU,boiler,219,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate -Greenstar HIU,boiler,219,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Greenstar HIU,boiler,219,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Greenstar HIU,boiler,219,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Greenstar HIU,boiler,219,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Greenstar HIU,boiler,219,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Greenstar HIU,boiler,219,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Greenstar HIU,boiler,219,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Greenstar HIU,boiler,219,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Greenstar HIU,boiler,219,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Greenstar HIU,boiler,219,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Greenstar HIU,boiler,219,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Greenstar HIU,boiler,219,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Greenstar HIU,boiler,219,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Greenstar HIU,boiler,219,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Greenstar HIU,boiler,219,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Greenstar HIU,boiler,219,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Greenstar HIU,boiler,219,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Greenstar HIU,boiler,219,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Greenstar HIU,boiler,219,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Greenstar HIU,boiler,219,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Greenstar HIU,boiler,219,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Greenstar HIU,boiler,219,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Greenstar HIU,boiler,219,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Greenstar HIU,boiler,219,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Greenstar HIU,boiler,219,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Greenstar HIU,boiler,219,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Greenstar HIU,boiler,219,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Greenstar HIU,boiler,219,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Greenstar HIU,boiler,219,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Greenstar HIU,boiler,219,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Greenstar HIU,boiler,219,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Greenstar HIU,boiler,219,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Greenstar HIU,boiler,219,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Greenstar HIU,boiler,219,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Greenstar HIU,boiler,219,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Greenstar HIU,boiler,219,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Greenstar HIU,boiler,219,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Greenstar HIU,boiler,219,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Greenstar HIU,boiler,219,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Greenstar HIU,boiler,219,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Greenstar HIU,boiler,219,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Logamax Plus GB122/Condense 2300,boiler,234,reset,Reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_Reset,sensor.boiler_reset +EasyControl Adapter,boiler,211,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +EasyControl Adapter,boiler,211,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +EasyControl Adapter,boiler,211,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +EasyControl Adapter,boiler,211,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +EasyControl Adapter,boiler,211,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +EasyControl Adapter,boiler,211,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +Greenstar HIU/Logamax kompakt WS170,boiler,219,netflowtemp,heat network flow temp,ushort (>=0<=3199),C,false,sensor.boiler_heat_network_flow_temp,sensor.boiler_netflowtemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,heatvalve,heating valve,uint (>=0<=100),%,false,sensor.boiler_heating_valve,sensor.boiler_heatvalve +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwvalve,valve,uint (>=0<=100),%,false,sensor.boiler_valve,sensor.boiler_wwvalve +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow +Greenstar HIU/Logamax kompakt WS170,boiler,219,keepwarmtemp,keep warm temperature,uint (>=0<=254),C,true,number.boiler_keep_warm_temperature,number.boiler_keepwarmtemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,setreturntemp,set temp return,uint (>=0<=254),C,true,number.boiler_set_temp_return,number.boiler_setreturntemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,heating,heating,boolean, ,false,binary_sensor.boiler_heating,binary_sensor.boiler_heating +Greenstar HIU/Logamax kompakt WS170,boiler,219,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff +Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive +Greenstar HIU/Logamax kompakt WS170,boiler,219,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive +Greenstar HIU/Logamax kompakt WS170,boiler,219,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Greenstar HIU/Logamax kompakt WS170,boiler,219,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Greenstar HIU/Logamax kompakt WS170,boiler,219,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated +Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump +Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Greenstar HIU/Logamax kompakt WS170,boiler,219,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Greenstar HIU/Logamax kompakt WS170,boiler,219,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Greenstar HIU/Logamax kompakt WS170,boiler,219,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Greenstar HIU/Logamax kompakt WS170,boiler,219,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Greenstar HIU/Logamax kompakt WS170,boiler,219,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Greenstar HIU/Logamax kompakt WS170,boiler,219,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Greenstar HIU/Logamax kompakt WS170,boiler,219,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Greenstar HIU/Logamax kompakt WS170,boiler,219,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Greenstar HIU/Logamax kompakt WS170,boiler,219,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Greenstar HIU/Logamax kompakt WS170,boiler,219,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode +Greenstar HIU/Logamax kompakt WS170,boiler,219,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode +Greenstar HIU/Logamax kompakt WS170,boiler,219,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Greenstar HIU/Logamax kompakt WS170,boiler,219,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage +Greenstar HIU/Logamax kompakt WS170,boiler,219,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance +Greenstar HIU/Logamax kompakt WS170,boiler,219,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Greenstar HIU/Logamax kompakt WS170,boiler,219,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate +Greenstar HIU/Logamax kompakt WS170,boiler,219,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops +Greenstar HIU/Logamax kompakt WS170,boiler,219,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive +Greenstar HIU/Logamax kompakt WS170,boiler,219,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Greenstar HIU/Logamax kompakt WS170,boiler,219,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Logamax Plus GB122/Condense 2300,boiler,234,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Logamax Plus GB122/Condense 2300,boiler,234,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logamax Plus GB122/Condense 2300,boiler,234,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Logamax Plus GB122/Condense 2300,boiler,234,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Logamax Plus GB122/Condense 2300,boiler,234,selflowtemp,selected flow temperature,uint (>=0<=254),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Logamax Plus GB122/Condense 2300,boiler,234,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Logamax Plus GB122/Condense 2300,boiler,234,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Logamax Plus GB122/Condense 2300,boiler,234,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Logamax Plus GB122/Condense 2300,boiler,234,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp @@ -2477,38 +2771,38 @@ Logamax Plus GB122/Condense 2300,boiler,234,rettemp,return temperature,ushort (> Logamax Plus GB122/Condense 2300,boiler,234,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Logamax Plus GB122/Condense 2300,boiler,234,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Logamax Plus GB122/Condense 2300,boiler,234,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Logamax Plus GB122/Condense 2300,boiler,234,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Logamax Plus GB122/Condense 2300,boiler,234,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Logamax Plus GB122/Condense 2300,boiler,234,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Logamax Plus GB122/Condense 2300,boiler,234,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Logamax Plus GB122/Condense 2300,boiler,234,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr -Logamax Plus GB122/Condense 2300,boiler,234,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Logamax Plus GB122/Condense 2300,boiler,234,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Logamax Plus GB122/Condense 2300,boiler,234,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Logamax Plus GB122/Condense 2300,boiler,234,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat +Logamax Plus GB122/Condense 2300,boiler,234,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Logamax Plus GB122/Condense 2300,boiler,234,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Logamax Plus GB122/Condense 2300,boiler,234,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Logamax Plus GB122/Condense 2300,boiler,234,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Logamax Plus GB122/Condense 2300,boiler,234,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Logamax Plus GB122/Condense 2300,boiler,234,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Logamax Plus GB122/Condense 2300,boiler,234,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Logamax Plus GB122/Condense 2300,boiler,234,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Logamax Plus GB122/Condense 2300,boiler,234,heatingtemp,heating temperature,uint (>=0<=254),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Logamax Plus GB122/Condense 2300,boiler,234,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Logamax Plus GB122/Condense 2300,boiler,234,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Logamax Plus GB122/Condense 2300,boiler,234,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Logamax Plus GB122/Condense 2300,boiler,234,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logamax Plus GB122/Condense 2300,boiler,234,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Logamax Plus GB122/Condense 2300,boiler,234,pumpdelay,pump delay,uint (>=0<=254),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Logamax Plus GB122/Condense 2300,boiler,234,burnminperiod,burner min period,uint (>=0<=254),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Logamax Plus GB122/Condense 2300,boiler,234,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Logamax Plus GB122/Condense 2300,boiler,234,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Logamax Plus GB122/Condense 2300,boiler,234,boilhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Logamax Plus GB122/Condense 2300,boiler,234,boilhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Logamax Plus GB122/Condense 2300,boiler,234,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Logamax Plus GB122/Condense 2300,boiler,234,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Logamax Plus GB122/Condense 2300,boiler,234,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Logamax Plus GB122/Condense 2300,boiler,234,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Logamax Plus GB122/Condense 2300,boiler,234,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Logamax Plus GB122/Condense 2300,boiler,234,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Logamax Plus GB122/Condense 2300,boiler,234,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Logamax Plus GB122/Condense 2300,boiler,234,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Logamax Plus GB122/Condense 2300,boiler,234,burnstarts,burner starts,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts -Logamax Plus GB122/Condense 2300,boiler,234,burnworkmin,total burner operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin -Logamax Plus GB122/Condense 2300,boiler,234,burn2workmin,burner stage 2 operating time,time (>=0<=65533),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin -Logamax Plus GB122/Condense 2300,boiler,234,heatworkmin,total heat operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Logamax Plus GB122/Condense 2300,boiler,234,heatstarts,burner starts heating,ulong (>=0<=65533), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts -Logamax Plus GB122/Condense 2300,boiler,234,ubauptime,total UBA operating time,time (>=0<=65533),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime +Logamax Plus GB122/Condense 2300,boiler,234,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Logamax Plus GB122/Condense 2300,boiler,234,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin +Logamax Plus GB122/Condense 2300,boiler,234,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin +Logamax Plus GB122/Condense 2300,boiler,234,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin +Logamax Plus GB122/Condense 2300,boiler,234,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Logamax Plus GB122/Condense 2300,boiler,234,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Logamax Plus GB122/Condense 2300,boiler,234,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Logamax Plus GB122/Condense 2300,boiler,234,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Logamax Plus GB122/Condense 2300,boiler,234,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber @@ -2522,6 +2816,7 @@ Logamax Plus GB122/Condense 2300,boiler,234,wwtapactivated,turn on/off,boolean, Logamax Plus GB122/Condense 2300,boiler,234,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Logamax Plus GB122/Condense 2300,boiler,234,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Logamax Plus GB122/Condense 2300,boiler,234,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow +Logamax Plus GB122/Condense 2300,boiler,234,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Logamax Plus GB122/Condense 2300,boiler,234,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Logamax Plus GB122/Condense 2300,boiler,234,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Logamax Plus GB122/Condense 2300,boiler,234,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp @@ -2531,12 +2826,12 @@ Logamax Plus GB122/Condense 2300,boiler,234,wwcomfort1,comfort mode,enum [high c Logamax Plus GB122/Condense 2300,boiler,234,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Logamax Plus GB122/Condense 2300,boiler,234,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Logamax Plus GB122/Condense 2300,boiler,234,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Logamax Plus GB122/Condense 2300,boiler,234,wwmaxtemp,maximum temperature,uint (>=0<=70),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp +Logamax Plus GB122/Condense 2300,boiler,234,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Logamax Plus GB122/Condense 2300,boiler,234,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Logamax Plus GB122/Condense 2300,boiler,234,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Logamax Plus GB122/Condense 2300,boiler,234,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Logamax Plus GB122/Condense 2300,boiler,234,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Logamax Plus GB122/Condense 2300,boiler,234,wwdisinfectiontemp,disinfection temperature,uint (>=0<=254),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp +Logamax Plus GB122/Condense 2300,boiler,234,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Logamax Plus GB122/Condense 2300,boiler,234,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Logamax Plus GB122/Condense 2300,boiler,234,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Logamax Plus GB122/Condense 2300,boiler,234,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp @@ -2555,91 +2850,98 @@ Logamax Plus GB122/Condense 2300,boiler,234,ww3wayvalve,3-way valve active,boole Logamax Plus GB122/Condense 2300,boiler,234,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Logamax Plus GB122/Condense 2300,boiler,234,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Logamax Plus GB122/Condense 2300,boiler,234,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Logamax Plus GB122/Condense 2300,boiler,234,wwstarts,starts,ulong (>=0<=65533), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Logamax Plus GB122/Condense 2300,boiler,234,wwworkm,active time,time (>=0<=65533),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Logamax Plus GB122/Condense 2300,boiler,234,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts +Logamax Plus GB122/Condense 2300,boiler,234,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm +Logamax Plus GB122/Condense 2300,boiler,234,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Logamax Plus GB122/Condense 2300,boiler,234,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Logamax Plus GB122/Condense 2300,boiler,234,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Logamax Plus GB122/Condense 2300,boiler,234,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww Logamatic TC100/Moduline Easy,thermostat,202,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode Logamatic TC100/Moduline Easy,thermostat,202,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode Logamatic TC100/Moduline Easy,thermostat,202,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime Logamatic TC100/Moduline Easy,thermostat,202,seltemp,selected room temperature,short (>=-319<=319),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp Logamatic TC100/Moduline Easy,thermostat,202,currtemp,current room temperature,short (>=-319<=319),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp Logamatic TC100/Moduline Easy,thermostat,202,haclimate,Discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_Discovery_current_room_temperature,sensor.thermostat_hc1_haclimate -EasyControl CT200,thermostat,203,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode -EasyControl CT200,thermostat,203,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode -EasyControl CT200,thermostat,203,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -EasyControl CT200,thermostat,203,seltemp,selected room temperature,short (>=-319<=319),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp -EasyControl CT200,thermostat,203,currtemp,current room temperature,short (>=-319<=319),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp -EasyControl CT200,thermostat,203,haclimate,Discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_Discovery_current_room_temperature,sensor.thermostat_hc1_haclimate -UI800,thermostat,4,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode -UI800,thermostat,4,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode -UI800,thermostat,4,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime -UI800,thermostat,4,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset -UI800,thermostat,4,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry -UI800,thermostat,4,dampedoutdoortemp,damped outdoor temperature,short (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp -UI800,thermostat,4,floordrytemp,floor drying temperature,uint (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp -UI800,thermostat,4,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building -UI800,thermostat,4,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp -UI800,thermostat,4,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping -UI800,thermostat,4,wwsettemp,set temperature,uint (>=0<=254),C,true,number.thermostat_set_temperature,number.thermostat_wwsettemp -UI800,thermostat,4,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog\|eco], ,true,select.thermostat_mode,select.thermostat_wwmode -UI800,thermostat,4,wwsettemplow,set low temperature,uint (>=0<=254),C,true,number.thermostat_set_low_temperature,number.thermostat_wwsettemplow -UI800,thermostat,4,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode -UI800,thermostat,4,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_charge_duration,number.thermostat_wwchargeduration -UI800,thermostat,4,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge -UI800,thermostat,4,wwextra1,circuit 1 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_1_extra,sensor.thermostat_wwextra1 -UI800,thermostat,4,wwextra2,circuit 2 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_2_extra,sensor.thermostat_wwextra2 -UI800,thermostat,4,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting -UI800,thermostat,4,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday -UI800,thermostat,4,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_disinfection_time,number.thermostat_wwdisinfecttime -UI800,thermostat,4,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -UI800,thermostat,4,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -UI800,thermostat,4,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -UI800,thermostat,4,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -UI800,thermostat,4,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -UI800,thermostat,4,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -UI800,thermostat,4,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -UI800,thermostat,4,pvenableww,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenableww -UI800,thermostat,4,pvraiseheat,raise heating with PV,int (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat -UI800,thermostat,4,pvlowercool,lower cooling with PV,int (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool -UI800,thermostat,4,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -UI800,thermostat,4,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp -UI800,thermostat,4,haclimate,Discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_Discovery_current_room_temperature,sensor.thermostat_hc1_haclimate -UI800,thermostat,4,mode,mode,enum [manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode -UI800,thermostat,4,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -UI800,thermostat,4,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -UI800,thermostat,4,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp -UI800,thermostat,4,comforttemp,comfort temperature,uint (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp -UI800,thermostat,4,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp -UI800,thermostat,4,designtemp,design temperature,uint (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp -UI800,thermostat,4,offsettemp,offset temperature,int (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp -UI800,thermostat,4,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -UI800,thermostat,4,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -UI800,thermostat,4,roominfluence,room influence,uint (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence -UI800,thermostat,4,roominflfactor,room influence factor,uint (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor -UI800,thermostat,4,curroominfl,current room influence,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl -UI800,thermostat,4,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode -UI800,thermostat,4,nofrosttemp,nofrost temperature,int (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp -UI800,thermostat,4,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp -UI800,thermostat,4,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype -UI800,thermostat,4,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode -UI800,thermostat,4,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode -UI800,thermostat,4,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode -UI800,thermostat,4,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate -UI800,thermostat,4,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode -UI800,thermostat,4,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -UI800,thermostat,4,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp -UI800,thermostat,4,remoteseltemp,temporary set temperature from remote,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp -UI800,thermostat,4,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup -UI800,thermostat,4,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization -UI800,thermostat,4,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode -UI800,thermostat,4,noreducetemp,no reduce below temperature,int (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp -UI800,thermostat,4,reducetemp,off/reduce switch temperature,int (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp -UI800,thermostat,4,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio -UI800,thermostat,4,cooling,cooling,boolean, ,true,switch.thermostat_hc1_cooling,switch.thermostat_hc1_cooling -UI800,thermostat,4,coolingon,cooling,boolean, ,false,binary_sensor.thermostat_hc1_cooling,binary_sensor.thermostat_hc1_coolingon -UI800,thermostat,4,hpmode,HP Mode,enum [heating\|cooling\|heating&cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode -UI800,thermostat,4,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset -UI800,thermostat,4,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff -UI800,thermostat,4,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp +EasyControl/CT200,thermostat,203,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode +EasyControl/CT200,thermostat,203,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode +EasyControl/CT200,thermostat,203,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime +EasyControl/CT200,thermostat,203,seltemp,selected room temperature,short (>=-319<=319),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp +EasyControl/CT200,thermostat,203,currtemp,current room temperature,short (>=-319<=319),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +EasyControl/CT200,thermostat,203,haclimate,Discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_Discovery_current_room_temperature,sensor.thermostat_hc1_haclimate +UI800/BC400,thermostat,4,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode +UI800/BC400,thermostat,4,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode +UI800/BC400,thermostat,4,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime +UI800/BC400,thermostat,4,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset +UI800/BC400,thermostat,4,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry +UI800/BC400,thermostat,4,dampedoutdoortemp,damped outdoor temperature,short (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp +UI800/BC400,thermostat,4,floordrytemp,floor drying temperature,uint (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp +UI800/BC400,thermostat,4,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building +UI800/BC400,thermostat,4,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp +UI800/BC400,thermostat,4,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping +UI800/BC400,thermostat,4,wwsettemp,set temperature,uint (>=0<=254),C,true,number.thermostat_set_temperature,number.thermostat_wwsettemp +UI800/BC400,thermostat,4,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog\|eco], ,true,select.thermostat_mode,select.thermostat_wwmode +UI800/BC400,thermostat,4,wwsettemplow,set low temperature,uint (>=0<=254),C,true,number.thermostat_set_low_temperature,number.thermostat_wwsettemplow +UI800/BC400,thermostat,4,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode +UI800/BC400,thermostat,4,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_charge_duration,number.thermostat_wwchargeduration +UI800/BC400,thermostat,4,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge +UI800/BC400,thermostat,4,wwextra1,circuit 1 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_1_extra,sensor.thermostat_wwextra1 +UI800/BC400,thermostat,4,wwextra2,circuit 2 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_2_extra,sensor.thermostat_wwextra2 +UI800/BC400,thermostat,4,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting +UI800/BC400,thermostat,4,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday +UI800/BC400,thermostat,4,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_disinfection_time,number.thermostat_wwdisinfecttime +UI800/BC400,thermostat,4,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy +UI800/BC400,thermostat,4,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +UI800/BC400,thermostat,4,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +UI800/BC400,thermostat,4,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +UI800/BC400,thermostat,4,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +UI800/BC400,thermostat,4,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +UI800/BC400,thermostat,4,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +UI800/BC400,thermostat,4,pvenableww,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenableww +UI800/BC400,thermostat,4,pvraiseheat,raise heating with PV,int (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat +UI800/BC400,thermostat,4,pvlowercool,lower cooling with PV,int (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool +UI800/BC400,thermostat,4,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +UI800/BC400,thermostat,4,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +UI800/BC400,thermostat,4,haclimate,Discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_Discovery_current_room_temperature,sensor.thermostat_hc1_haclimate +UI800/BC400,thermostat,4,mode,mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode +UI800/BC400,thermostat,4,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype +UI800/BC400,thermostat,4,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +UI800/BC400,thermostat,4,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp +UI800/BC400,thermostat,4,comforttemp,comfort temperature,uint (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp +UI800/BC400,thermostat,4,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +UI800/BC400,thermostat,4,designtemp,design temperature,uint (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +UI800/BC400,thermostat,4,offsettemp,offset temperature,int (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp +UI800/BC400,thermostat,4,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +UI800/BC400,thermostat,4,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +UI800/BC400,thermostat,4,roominfluence,room influence,uint (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence +UI800/BC400,thermostat,4,roominflfactor,room influence factor,uint (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +UI800/BC400,thermostat,4,curroominfl,current room influence,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl +UI800/BC400,thermostat,4,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode +UI800/BC400,thermostat,4,nofrosttemp,nofrost temperature,int (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +UI800/BC400,thermostat,4,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +UI800/BC400,thermostat,4,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype +UI800/BC400,thermostat,4,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode +UI800/BC400,thermostat,4,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode +UI800/BC400,thermostat,4,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode +UI800/BC400,thermostat,4,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate +UI800/BC400,thermostat,4,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode +UI800/BC400,thermostat,4,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program +UI800/BC400,thermostat,4,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp +UI800/BC400,thermostat,4,remoteseltemp,temporary set temperature from remote,int (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp +UI800/BC400,thermostat,4,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup +UI800/BC400,thermostat,4,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization +UI800/BC400,thermostat,4,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode +UI800/BC400,thermostat,4,noreducetemp,no reduce below temperature,int (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp +UI800/BC400,thermostat,4,reducetemp,off/reduce switch temperature,int (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp +UI800/BC400,thermostat,4,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio +UI800/BC400,thermostat,4,cooling,cooling,boolean, ,true,switch.thermostat_hc1_cooling,switch.thermostat_hc1_cooling +UI800/BC400,thermostat,4,coolingon,cooling,boolean, ,false,binary_sensor.thermostat_hc1_cooling,binary_sensor.thermostat_hc1_coolingon +UI800/BC400,thermostat,4,hpmode,HP Mode,enum [heating\|cooling\|heating&cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode +UI800/BC400,thermostat,4,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset +UI800/BC400,thermostat,4,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff +UI800/BC400,thermostat,4,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp +UI800/BC400,thermostat,4,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control +UI800/BC400,thermostat,4,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +UI800/BC400,thermostat,4,remotehum,room humidity from remote,uint (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum RC10,thermostat,65,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC10,thermostat,65,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC10,thermostat,65,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime @@ -2719,7 +3021,7 @@ RC30,thermostat,67,noreducetemp,no reduce below temperature,int (>=-31<=10),C,tr RC30,thermostat,67,reducetemp,off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp RC30,thermostat,67,vacreducetemp,vacations off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_vacations_off/reduce_switch_temperature,number.thermostat_hc1_vacreducetemp RC30,thermostat,67,vacreducemode,vacations reduce mode,enum [nofrost\|reduce\|room\|outdoor], ,true,select.thermostat_hc1_vacations_reduce_mode,select.thermostat_hc1_vacreducemode -RC30,thermostat,67,remotetemp,room temperature from remote,short (>=-3199<=3199),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +RC30,thermostat,67,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp RC30,thermostat,67,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio RC30,thermostat,67,switchtime1,own1 program switchtime,string, ,true,sensor.thermostat_hc1_own1_program_switchtime,sensor.thermostat_hc1_switchtime1 RC30,thermostat,67,switchtime2,own2 program switchtime,string, ,true,sensor.thermostat_hc1_own2_program_switchtime,sensor.thermostat_hc1_switchtime2 @@ -2861,7 +3163,7 @@ RC35,thermostat,86,noreducetemp,no reduce below temperature,int (>=-31<=10),C,tr RC35,thermostat,86,reducetemp,off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp RC35,thermostat,86,vacreducetemp,vacations off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_vacations_off/reduce_switch_temperature,number.thermostat_hc1_vacreducetemp RC35,thermostat,86,vacreducemode,vacations reduce mode,enum [nofrost\|reduce\|room\|outdoor], ,true,select.thermostat_hc1_vacations_reduce_mode,select.thermostat_hc1_vacreducemode -RC35,thermostat,86,remotetemp,room temperature from remote,short (>=-3199<=3199),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +RC35,thermostat,86,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp RC35,thermostat,86,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio RC35,thermostat,86,switchtime1,own1 program switchtime,string, ,true,sensor.thermostat_hc1_own1_program_switchtime,sensor.thermostat_hc1_switchtime1 RC35,thermostat,86,switchtime2,own2 program switchtime,string, ,true,sensor.thermostat_hc1_own2_program_switchtime,sensor.thermostat_hc1_switchtime2 @@ -2956,7 +3258,7 @@ RC200/CW100,thermostat,157,pvlowercool,lower cooling with PV,int (>=-5<=0),K,tru RC200/CW100,thermostat,157,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp RC200/CW100,thermostat,157,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC200/CW100,thermostat,157,haclimate,Discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_Discovery_current_room_temperature,sensor.thermostat_hc1_haclimate -RC200/CW100,thermostat,157,mode,mode,enum [manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode +RC200/CW100,thermostat,157,mode,mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC200/CW100,thermostat,157,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype RC200/CW100,thermostat,157,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp RC200/CW100,thermostat,157,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp @@ -2980,7 +3282,7 @@ RC200/CW100,thermostat,157,hpoperatingstate,heatpump operating state,enum [heati RC200/CW100,thermostat,157,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode RC200/CW100,thermostat,157,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program RC200/CW100,thermostat,157,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp -RC200/CW100,thermostat,157,remoteseltemp,temporary set temperature from remote,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp +RC200/CW100,thermostat,157,remoteseltemp,temporary set temperature from remote,int (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp RC200/CW100,thermostat,157,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup RC200/CW100,thermostat,157,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization RC200/CW100,thermostat,157,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode @@ -2993,6 +3295,9 @@ RC200/CW100,thermostat,157,hpmode,HP Mode,enum [heating\|cooling\|heating&coolin RC200/CW100,thermostat,157,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset RC200/CW100,thermostat,157,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff RC200/CW100,thermostat,157,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp +RC200/CW100,thermostat,157,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control +RC200/CW100,thermostat,157,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +RC200/CW100,thermostat,157,remotehum,room humidity from remote,uint (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime @@ -3027,7 +3332,7 @@ RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,pvlowercool RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,haclimate,Discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_Discovery_current_room_temperature,sensor.thermostat_hc1_haclimate -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,mode,mode,enum [manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,mode,mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp @@ -3051,7 +3356,7 @@ RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hpoperating RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,remoteseltemp,temporary set temperature from remote,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,remoteseltemp,temporary set temperature from remote,int (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode @@ -3064,6 +3369,9 @@ RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hpmode,HP M RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,remotehum,room humidity from remote,uint (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum RC100/Moduline 1000/1010,thermostat,165,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC100/Moduline 1000/1010,thermostat,165,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC100/Moduline 1000/1010,thermostat,165,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime @@ -3098,7 +3406,7 @@ RC100/Moduline 1000/1010,thermostat,165,pvlowercool,lower cooling with PV,int (> RC100/Moduline 1000/1010,thermostat,165,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp RC100/Moduline 1000/1010,thermostat,165,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC100/Moduline 1000/1010,thermostat,165,haclimate,Discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_Discovery_current_room_temperature,sensor.thermostat_hc1_haclimate -RC100/Moduline 1000/1010,thermostat,165,mode,mode,enum [manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode +RC100/Moduline 1000/1010,thermostat,165,mode,mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC100/Moduline 1000/1010,thermostat,165,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype RC100/Moduline 1000/1010,thermostat,165,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp RC100/Moduline 1000/1010,thermostat,165,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp @@ -3122,7 +3430,7 @@ RC100/Moduline 1000/1010,thermostat,165,hpoperatingstate,heatpump operating stat RC100/Moduline 1000/1010,thermostat,165,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode RC100/Moduline 1000/1010,thermostat,165,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program RC100/Moduline 1000/1010,thermostat,165,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp -RC100/Moduline 1000/1010,thermostat,165,remoteseltemp,temporary set temperature from remote,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp +RC100/Moduline 1000/1010,thermostat,165,remoteseltemp,temporary set temperature from remote,int (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp RC100/Moduline 1000/1010,thermostat,165,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup RC100/Moduline 1000/1010,thermostat,165,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization RC100/Moduline 1000/1010,thermostat,165,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode @@ -3135,6 +3443,9 @@ RC100/Moduline 1000/1010,thermostat,165,hpmode,HP Mode,enum [heating\|cooling\|h RC100/Moduline 1000/1010,thermostat,165,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset RC100/Moduline 1000/1010,thermostat,165,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff RC100/Moduline 1000/1010,thermostat,165,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp +RC100/Moduline 1000/1010,thermostat,165,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control +RC100/Moduline 1000/1010,thermostat,165,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +RC100/Moduline 1000/1010,thermostat,165,remotehum,room humidity from remote,uint (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum Rego 2000/3000,thermostat,172,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode Rego 2000/3000,thermostat,172,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode Rego 2000/3000,thermostat,172,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime @@ -3169,7 +3480,7 @@ Rego 2000/3000,thermostat,172,pvlowercool,lower cooling with PV,int (>=-5<=0),K, Rego 2000/3000,thermostat,172,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp Rego 2000/3000,thermostat,172,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp Rego 2000/3000,thermostat,172,haclimate,Discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_Discovery_current_room_temperature,sensor.thermostat_hc1_haclimate -Rego 2000/3000,thermostat,172,mode,mode,enum [manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode +Rego 2000/3000,thermostat,172,mode,mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode Rego 2000/3000,thermostat,172,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype Rego 2000/3000,thermostat,172,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp Rego 2000/3000,thermostat,172,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp @@ -3193,7 +3504,7 @@ Rego 2000/3000,thermostat,172,hpoperatingstate,heatpump operating state,enum [he Rego 2000/3000,thermostat,172,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode Rego 2000/3000,thermostat,172,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program Rego 2000/3000,thermostat,172,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp -Rego 2000/3000,thermostat,172,remoteseltemp,temporary set temperature from remote,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp +Rego 2000/3000,thermostat,172,remoteseltemp,temporary set temperature from remote,int (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp Rego 2000/3000,thermostat,172,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup Rego 2000/3000,thermostat,172,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization Rego 2000/3000,thermostat,172,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode @@ -3206,6 +3517,9 @@ Rego 2000/3000,thermostat,172,hpmode,HP Mode,enum [heating\|cooling\|heating&coo Rego 2000/3000,thermostat,172,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset Rego 2000/3000,thermostat,172,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff Rego 2000/3000,thermostat,172,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp +Rego 2000/3000,thermostat,172,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control +Rego 2000/3000,thermostat,172,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +Rego 2000/3000,thermostat,172,remotehum,room humidity from remote,uint (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum Comfort RF,thermostat,215,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode Comfort RF,thermostat,215,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode Comfort RF,thermostat,215,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime @@ -3233,77 +3547,80 @@ Comfort+2RF,thermostat,246,haclimate,Discovery current room temperature,enum [se Comfort+2RF,thermostat,246,mode,mode,enum [auto\|off], ,false,sensor.thermostat_hc1_mode,sensor.thermostat_hc1_mode Comfort+2RF,thermostat,246,modetype,mode type,enum [off\|on], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype Comfort+2RF,thermostat,246,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp -Rego 3000/UI800,thermostat,253,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode -Rego 3000/UI800,thermostat,253,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode -Rego 3000/UI800,thermostat,253,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime -Rego 3000/UI800,thermostat,253,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset -Rego 3000/UI800,thermostat,253,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry -Rego 3000/UI800,thermostat,253,dampedoutdoortemp,damped outdoor temperature,short (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp -Rego 3000/UI800,thermostat,253,floordrytemp,floor drying temperature,uint (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp -Rego 3000/UI800,thermostat,253,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building -Rego 3000/UI800,thermostat,253,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp -Rego 3000/UI800,thermostat,253,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping -Rego 3000/UI800,thermostat,253,wwsettemp,set temperature,uint (>=0<=254),C,true,number.thermostat_set_temperature,number.thermostat_wwsettemp -Rego 3000/UI800,thermostat,253,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog\|eco], ,true,select.thermostat_mode,select.thermostat_wwmode -Rego 3000/UI800,thermostat,253,wwsettemplow,set low temperature,uint (>=0<=254),C,true,number.thermostat_set_low_temperature,number.thermostat_wwsettemplow -Rego 3000/UI800,thermostat,253,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode -Rego 3000/UI800,thermostat,253,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_charge_duration,number.thermostat_wwchargeduration -Rego 3000/UI800,thermostat,253,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge -Rego 3000/UI800,thermostat,253,wwextra1,circuit 1 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_1_extra,sensor.thermostat_wwextra1 -Rego 3000/UI800,thermostat,253,wwextra2,circuit 2 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_2_extra,sensor.thermostat_wwextra2 -Rego 3000/UI800,thermostat,253,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting -Rego 3000/UI800,thermostat,253,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday -Rego 3000/UI800,thermostat,253,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_disinfection_time,number.thermostat_wwdisinfecttime -Rego 3000/UI800,thermostat,253,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -Rego 3000/UI800,thermostat,253,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -Rego 3000/UI800,thermostat,253,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -Rego 3000/UI800,thermostat,253,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -Rego 3000/UI800,thermostat,253,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -Rego 3000/UI800,thermostat,253,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -Rego 3000/UI800,thermostat,253,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -Rego 3000/UI800,thermostat,253,pvenableww,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenableww -Rego 3000/UI800,thermostat,253,pvraiseheat,raise heating with PV,int (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat -Rego 3000/UI800,thermostat,253,pvlowercool,lower cooling with PV,int (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool -Rego 3000/UI800,thermostat,253,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -Rego 3000/UI800,thermostat,253,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp -Rego 3000/UI800,thermostat,253,haclimate,Discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_Discovery_current_room_temperature,sensor.thermostat_hc1_haclimate -Rego 3000/UI800,thermostat,253,mode,mode,enum [manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode -Rego 3000/UI800,thermostat,253,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -Rego 3000/UI800,thermostat,253,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -Rego 3000/UI800,thermostat,253,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp -Rego 3000/UI800,thermostat,253,comforttemp,comfort temperature,uint (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp -Rego 3000/UI800,thermostat,253,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp -Rego 3000/UI800,thermostat,253,designtemp,design temperature,uint (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp -Rego 3000/UI800,thermostat,253,offsettemp,offset temperature,int (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp -Rego 3000/UI800,thermostat,253,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -Rego 3000/UI800,thermostat,253,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -Rego 3000/UI800,thermostat,253,roominfluence,room influence,uint (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence -Rego 3000/UI800,thermostat,253,roominflfactor,room influence factor,uint (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor -Rego 3000/UI800,thermostat,253,curroominfl,current room influence,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl -Rego 3000/UI800,thermostat,253,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode -Rego 3000/UI800,thermostat,253,nofrosttemp,nofrost temperature,int (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp -Rego 3000/UI800,thermostat,253,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp -Rego 3000/UI800,thermostat,253,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype -Rego 3000/UI800,thermostat,253,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode -Rego 3000/UI800,thermostat,253,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode -Rego 3000/UI800,thermostat,253,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode -Rego 3000/UI800,thermostat,253,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate -Rego 3000/UI800,thermostat,253,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode -Rego 3000/UI800,thermostat,253,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -Rego 3000/UI800,thermostat,253,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp -Rego 3000/UI800,thermostat,253,remoteseltemp,temporary set temperature from remote,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp -Rego 3000/UI800,thermostat,253,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup -Rego 3000/UI800,thermostat,253,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization -Rego 3000/UI800,thermostat,253,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode -Rego 3000/UI800,thermostat,253,noreducetemp,no reduce below temperature,int (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp -Rego 3000/UI800,thermostat,253,reducetemp,off/reduce switch temperature,int (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp -Rego 3000/UI800,thermostat,253,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio -Rego 3000/UI800,thermostat,253,cooling,cooling,boolean, ,true,switch.thermostat_hc1_cooling,switch.thermostat_hc1_cooling -Rego 3000/UI800,thermostat,253,coolingon,cooling,boolean, ,false,binary_sensor.thermostat_hc1_cooling,binary_sensor.thermostat_hc1_coolingon -Rego 3000/UI800,thermostat,253,hpmode,HP Mode,enum [heating\|cooling\|heating&cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode -Rego 3000/UI800,thermostat,253,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset -Rego 3000/UI800,thermostat,253,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff -Rego 3000/UI800,thermostat,253,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode +Rego 3000/UI800/WSW196i/BC400,thermostat,253,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode +Rego 3000/UI800/WSW196i/BC400,thermostat,253,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime +Rego 3000/UI800/WSW196i/BC400,thermostat,253,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset +Rego 3000/UI800/WSW196i/BC400,thermostat,253,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry +Rego 3000/UI800/WSW196i/BC400,thermostat,253,dampedoutdoortemp,damped outdoor temperature,short (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,floordrytemp,floor drying temperature,uint (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building +Rego 3000/UI800/WSW196i/BC400,thermostat,253,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping +Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwsettemp,set temperature,uint (>=0<=254),C,true,number.thermostat_set_temperature,number.thermostat_wwsettemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog\|eco], ,true,select.thermostat_mode,select.thermostat_wwmode +Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwsettemplow,set low temperature,uint (>=0<=254),C,true,number.thermostat_set_low_temperature,number.thermostat_wwsettemplow +Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode +Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_charge_duration,number.thermostat_wwchargeduration +Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge +Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwextra1,circuit 1 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_1_extra,sensor.thermostat_wwextra1 +Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwextra2,circuit 2 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_2_extra,sensor.thermostat_wwextra2 +Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting +Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday +Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_disinfection_time,number.thermostat_wwdisinfecttime +Rego 3000/UI800/WSW196i/BC400,thermostat,253,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy +Rego 3000/UI800/WSW196i/BC400,thermostat,253,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +Rego 3000/UI800/WSW196i/BC400,thermostat,253,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +Rego 3000/UI800/WSW196i/BC400,thermostat,253,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +Rego 3000/UI800/WSW196i/BC400,thermostat,253,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +Rego 3000/UI800/WSW196i/BC400,thermostat,253,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +Rego 3000/UI800/WSW196i/BC400,thermostat,253,pvenableww,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenableww +Rego 3000/UI800/WSW196i/BC400,thermostat,253,pvraiseheat,raise heating with PV,int (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat +Rego 3000/UI800/WSW196i/BC400,thermostat,253,pvlowercool,lower cooling with PV,int (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool +Rego 3000/UI800/WSW196i/BC400,thermostat,253,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,haclimate,Discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_Discovery_current_room_temperature,sensor.thermostat_hc1_haclimate +Rego 3000/UI800/WSW196i/BC400,thermostat,253,mode,mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode +Rego 3000/UI800/WSW196i/BC400,thermostat,253,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype +Rego 3000/UI800/WSW196i/BC400,thermostat,253,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,comforttemp,comfort temperature,uint (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,designtemp,design temperature,uint (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,offsettemp,offset temperature,int (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,roominfluence,room influence,uint (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence +Rego 3000/UI800/WSW196i/BC400,thermostat,253,roominflfactor,room influence factor,uint (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +Rego 3000/UI800/WSW196i/BC400,thermostat,253,curroominfl,current room influence,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl +Rego 3000/UI800/WSW196i/BC400,thermostat,253,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode +Rego 3000/UI800/WSW196i/BC400,thermostat,253,nofrosttemp,nofrost temperature,int (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype +Rego 3000/UI800/WSW196i/BC400,thermostat,253,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode +Rego 3000/UI800/WSW196i/BC400,thermostat,253,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode +Rego 3000/UI800/WSW196i/BC400,thermostat,253,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode +Rego 3000/UI800/WSW196i/BC400,thermostat,253,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate +Rego 3000/UI800/WSW196i/BC400,thermostat,253,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode +Rego 3000/UI800/WSW196i/BC400,thermostat,253,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program +Rego 3000/UI800/WSW196i/BC400,thermostat,253,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,remoteseltemp,temporary set temperature from remote,int (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup +Rego 3000/UI800/WSW196i/BC400,thermostat,253,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization +Rego 3000/UI800/WSW196i/BC400,thermostat,253,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode +Rego 3000/UI800/WSW196i/BC400,thermostat,253,noreducetemp,no reduce below temperature,int (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,reducetemp,off/reduce switch temperature,int (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio +Rego 3000/UI800/WSW196i/BC400,thermostat,253,cooling,cooling,boolean, ,true,switch.thermostat_hc1_cooling,switch.thermostat_hc1_cooling +Rego 3000/UI800/WSW196i/BC400,thermostat,253,coolingon,cooling,boolean, ,false,binary_sensor.thermostat_hc1_cooling,binary_sensor.thermostat_hc1_coolingon +Rego 3000/UI800/WSW196i/BC400,thermostat,253,hpmode,HP Mode,enum [heating\|cooling\|heating&cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode +Rego 3000/UI800/WSW196i/BC400,thermostat,253,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset +Rego 3000/UI800/WSW196i/BC400,thermostat,253,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff +Rego 3000/UI800/WSW196i/BC400,thermostat,253,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control +Rego 3000/UI800/WSW196i/BC400,thermostat,253,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,remotehum,room humidity from remote,uint (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum ES72/RC20,thermostat,66,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode ES72/RC20,thermostat,66,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode ES72/RC20,thermostat,66,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime @@ -3383,7 +3700,7 @@ ES73,thermostat,76,noreducetemp,no reduce below temperature,int (>=-31<=10),C,tr ES73,thermostat,76,reducetemp,off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp ES73,thermostat,76,vacreducetemp,vacations off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_vacations_off/reduce_switch_temperature,number.thermostat_hc1_vacreducetemp ES73,thermostat,76,vacreducemode,vacations reduce mode,enum [nofrost\|reduce\|room\|outdoor], ,true,select.thermostat_hc1_vacations_reduce_mode,select.thermostat_hc1_vacreducemode -ES73,thermostat,76,remotetemp,room temperature from remote,short (>=-3199<=3199),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +ES73,thermostat,76,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp ES73,thermostat,76,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio ES73,thermostat,76,switchtime1,own1 program switchtime,string, ,true,sensor.thermostat_hc1_own1_program_switchtime,sensor.thermostat_hc1_switchtime1 ES73,thermostat,76,switchtime2,own2 program switchtime,string, ,true,sensor.thermostat_hc1_own2_program_switchtime,sensor.thermostat_hc1_switchtime2 @@ -3732,7 +4049,7 @@ MP100,mixer,204,poolshunt,pool shunt open/close (0% = pool / 100% = heat),uint ( SM10,solar,73,collectortemp,collector temperature (TS1),short (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp SM10,solar,73,cylbottomtemp,cylinder bottom temperature (TS2),short (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp SM10,solar,73,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump -SM10,solar,73,pumpworktime,pump working time,time (>=0<=65533),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime +SM10,solar,73,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime SM10,solar,73,cylmaxtemp,maximum cylinder temperature,uint (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp SM10,solar,73,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown SM10,solar,73,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated @@ -3741,36 +4058,36 @@ SM10,solar,73,pumpminmod,minimum pump modulation,uint (>=0<=100),%,true,number.s SM10,solar,73,turnondiff,pump turn on difference,uint (>=0<=254),C,true,number.solar_pump_turn_on_difference,number.solar_turnondiff SM10,solar,73,turnoffdiff,pump turn off difference,uint (>=0<=254),C,true,number.solar_pump_turn_off_difference,number.solar_turnoffdiff SM10,solar,73,solarpower,actual solar power,short (>=-31999<=31999),W,false,sensor.solar_actual_solar_power,sensor.solar_solarpower -SM10,solar,73,energylasthour,energy last hour,ulong (>=0<=39321),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour +SM10,solar,73,energylasthour,energy last hour,ulong (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour SM10,solar,73,maxflow,maximum solar flow,uint (>=0<=25),l/min,true,number.solar_maximum_solar_flow,number.solar_maxflow SM10,solar,73,wwmintemp,minimum temperature,uint (>=0<=254),C,true,number.solar_minimum_temperature,number.solar_wwmintemp SM10,solar,73,solarenabled,solarmodule enabled,boolean, ,true,switch.solar_solarmodule_enabled,switch.solar_solarenabled ISM1,solar,101,collectortemp,collector temperature (TS1),short (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp ISM1,solar,101,cylbottomtemp,cylinder bottom temperature (TS2),short (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp ISM1,solar,101,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump -ISM1,solar,101,pumpworktime,pump working time,time (>=0<=65533),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime +ISM1,solar,101,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime ISM1,solar,101,cylmaxtemp,maximum cylinder temperature,uint (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp ISM1,solar,101,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown ISM1,solar,101,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated ISM1,solar,101,cylmiddletemp,cylinder middle temperature (TS3),short (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp ISM1,solar,101,retheatassist,return temperature heat assistance (TS4),short (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist ISM1,solar,101,heatassistvalve,heat assistance valve (M1),boolean, ,false,binary_sensor.solar_heat_assistance_valve_(M1),binary_sensor.solar_heatassistvalve -ISM1,solar,101,energylasthour,energy last hour,ulong (>=0<=39321),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour +ISM1,solar,101,energylasthour,energy last hour,ulong (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour ISM2,solar,103,collectortemp,collector temperature (TS1),short (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp ISM2,solar,103,cylbottomtemp,cylinder bottom temperature (TS2),short (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp ISM2,solar,103,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump -ISM2,solar,103,pumpworktime,pump working time,time (>=0<=65533),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime +ISM2,solar,103,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime ISM2,solar,103,cylmaxtemp,maximum cylinder temperature,uint (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp ISM2,solar,103,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown ISM2,solar,103,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated ISM2,solar,103,cylmiddletemp,cylinder middle temperature (TS3),short (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp ISM2,solar,103,retheatassist,return temperature heat assistance (TS4),short (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist ISM2,solar,103,heatassistvalve,heat assistance valve (M1),boolean, ,false,binary_sensor.solar_heat_assistance_valve_(M1),binary_sensor.solar_heatassistvalve -ISM2,solar,103,energylasthour,energy last hour,ulong (>=0<=39321),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour +ISM2,solar,103,energylasthour,energy last hour,ulong (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour SM50,solar,162,collectortemp,collector temperature (TS1),short (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp SM50,solar,162,cylbottomtemp,cylinder bottom temperature (TS2),short (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp SM50,solar,162,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump -SM50,solar,162,pumpworktime,pump working time,time (>=0<=65533),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime +SM50,solar,162,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime SM50,solar,162,cylmaxtemp,maximum cylinder temperature,uint (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp SM50,solar,162,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown SM50,solar,162,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated @@ -3794,11 +4111,11 @@ SM50,solar,162,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heat SM50,solar,162,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown SM50,solar,162,collectormaxtemp,maximum collector temperature,uint (>=0<=254),C,true,number.solar_maximum_collector_temperature,number.solar_collectormaxtemp SM50,solar,162,collectormintemp,minimum collector temperature,uint (>=0<=254),C,true,number.solar_minimum_collector_temperature,number.solar_collectormintemp -SM50,solar,162,energylasthour,energy last hour,ulong (>=0<=39321),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour -SM50,solar,162,energytoday,total energy today,ulong (>=0<=65533),Wh,false,sensor.solar_total_energy_today,sensor.solar_energytoday -SM50,solar,162,energytotal,total energy,ulong (>=0<=39321),kWh,false,sensor.solar_total_energy,sensor.solar_energytotal -SM50,solar,162,pump2worktime,pump 2 working time,time (>=0<=65533),minutes,false,sensor.solar_pump_2_working_time,sensor.solar_pump2worktime -SM50,solar,162,m1worktime,differential control working time,time (>=0<=65533),minutes,false,sensor.solar_differential_control_working_time,sensor.solar_m1worktime +SM50,solar,162,energylasthour,energy last hour,ulong (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour +SM50,solar,162,energytoday,total energy today,ulong (>=0<=16777213),Wh,false,sensor.solar_total_energy_today,sensor.solar_energytoday +SM50,solar,162,energytotal,total energy,ulong (>=0<=1677721),kWh,false,sensor.solar_total_energy,sensor.solar_energytotal +SM50,solar,162,pump2worktime,pump 2 working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_2_working_time,sensor.solar_pump2worktime +SM50,solar,162,m1worktime,differential control working time,time (>=0<=16777213),minutes,false,sensor.solar_differential_control_working_time,sensor.solar_m1worktime SM50,solar,162,heattransfersystem,heattransfer system,boolean, ,true,switch.solar_heattransfer_system,switch.solar_heattransfersystem SM50,solar,162,externalcyl,external cylinder,boolean, ,true,switch.solar_external_cylinder,switch.solar_externalcyl SM50,solar,162,thermaldisinfect,thermal disinfection,boolean, ,true,switch.solar_thermal_disinfection,switch.solar_thermaldisinfect @@ -3826,7 +4143,7 @@ SM50,solar,162,swaprettemp,swap return temperature (TS15),ushort (>=0<=3199),C,f SM100/MS100,solar,163,collectortemp,collector temperature (TS1),short (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp SM100/MS100,solar,163,cylbottomtemp,cylinder bottom temperature (TS2),short (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp SM100/MS100,solar,163,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump -SM100/MS100,solar,163,pumpworktime,pump working time,time (>=0<=65533),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime +SM100/MS100,solar,163,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime SM100/MS100,solar,163,cylmaxtemp,maximum cylinder temperature,uint (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp SM100/MS100,solar,163,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown SM100/MS100,solar,163,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated @@ -3850,11 +4167,11 @@ SM100/MS100,solar,163,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_c SM100/MS100,solar,163,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown SM100/MS100,solar,163,collectormaxtemp,maximum collector temperature,uint (>=0<=254),C,true,number.solar_maximum_collector_temperature,number.solar_collectormaxtemp SM100/MS100,solar,163,collectormintemp,minimum collector temperature,uint (>=0<=254),C,true,number.solar_minimum_collector_temperature,number.solar_collectormintemp -SM100/MS100,solar,163,energylasthour,energy last hour,ulong (>=0<=39321),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour -SM100/MS100,solar,163,energytoday,total energy today,ulong (>=0<=65533),Wh,false,sensor.solar_total_energy_today,sensor.solar_energytoday -SM100/MS100,solar,163,energytotal,total energy,ulong (>=0<=39321),kWh,false,sensor.solar_total_energy,sensor.solar_energytotal -SM100/MS100,solar,163,pump2worktime,pump 2 working time,time (>=0<=65533),minutes,false,sensor.solar_pump_2_working_time,sensor.solar_pump2worktime -SM100/MS100,solar,163,m1worktime,differential control working time,time (>=0<=65533),minutes,false,sensor.solar_differential_control_working_time,sensor.solar_m1worktime +SM100/MS100,solar,163,energylasthour,energy last hour,ulong (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour +SM100/MS100,solar,163,energytoday,total energy today,ulong (>=0<=16777213),Wh,false,sensor.solar_total_energy_today,sensor.solar_energytoday +SM100/MS100,solar,163,energytotal,total energy,ulong (>=0<=1677721),kWh,false,sensor.solar_total_energy,sensor.solar_energytotal +SM100/MS100,solar,163,pump2worktime,pump 2 working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_2_working_time,sensor.solar_pump2worktime +SM100/MS100,solar,163,m1worktime,differential control working time,time (>=0<=16777213),minutes,false,sensor.solar_differential_control_working_time,sensor.solar_m1worktime SM100/MS100,solar,163,heattransfersystem,heattransfer system,boolean, ,true,switch.solar_heattransfer_system,switch.solar_heattransfersystem SM100/MS100,solar,163,externalcyl,external cylinder,boolean, ,true,switch.solar_external_cylinder,switch.solar_externalcyl SM100/MS100,solar,163,thermaldisinfect,thermal disinfection,boolean, ,true,switch.solar_thermal_disinfection,switch.solar_thermaldisinfect @@ -3882,7 +4199,7 @@ SM100/MS100,solar,163,swaprettemp,swap return temperature (TS15),ushort (>=0<=31 SM200/MS200,solar,164,collectortemp,collector temperature (TS1),short (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp SM200/MS200,solar,164,cylbottomtemp,cylinder bottom temperature (TS2),short (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp SM200/MS200,solar,164,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump -SM200/MS200,solar,164,pumpworktime,pump working time,time (>=0<=65533),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime +SM200/MS200,solar,164,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime SM200/MS200,solar,164,cylmaxtemp,maximum cylinder temperature,uint (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp SM200/MS200,solar,164,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown SM200/MS200,solar,164,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated @@ -3906,11 +4223,11 @@ SM200/MS200,solar,164,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_c SM200/MS200,solar,164,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown SM200/MS200,solar,164,collectormaxtemp,maximum collector temperature,uint (>=0<=254),C,true,number.solar_maximum_collector_temperature,number.solar_collectormaxtemp SM200/MS200,solar,164,collectormintemp,minimum collector temperature,uint (>=0<=254),C,true,number.solar_minimum_collector_temperature,number.solar_collectormintemp -SM200/MS200,solar,164,energylasthour,energy last hour,ulong (>=0<=39321),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour -SM200/MS200,solar,164,energytoday,total energy today,ulong (>=0<=65533),Wh,false,sensor.solar_total_energy_today,sensor.solar_energytoday -SM200/MS200,solar,164,energytotal,total energy,ulong (>=0<=39321),kWh,false,sensor.solar_total_energy,sensor.solar_energytotal -SM200/MS200,solar,164,pump2worktime,pump 2 working time,time (>=0<=65533),minutes,false,sensor.solar_pump_2_working_time,sensor.solar_pump2worktime -SM200/MS200,solar,164,m1worktime,differential control working time,time (>=0<=65533),minutes,false,sensor.solar_differential_control_working_time,sensor.solar_m1worktime +SM200/MS200,solar,164,energylasthour,energy last hour,ulong (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour +SM200/MS200,solar,164,energytoday,total energy today,ulong (>=0<=16777213),Wh,false,sensor.solar_total_energy_today,sensor.solar_energytoday +SM200/MS200,solar,164,energytotal,total energy,ulong (>=0<=1677721),kWh,false,sensor.solar_total_energy,sensor.solar_energytotal +SM200/MS200,solar,164,pump2worktime,pump 2 working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_2_working_time,sensor.solar_pump2worktime +SM200/MS200,solar,164,m1worktime,differential control working time,time (>=0<=16777213),minutes,false,sensor.solar_differential_control_working_time,sensor.solar_m1worktime SM200/MS200,solar,164,heattransfersystem,heattransfer system,boolean, ,true,switch.solar_heattransfer_system,switch.solar_heattransfersystem SM200/MS200,solar,164,externalcyl,external cylinder,boolean, ,true,switch.solar_external_cylinder,switch.solar_externalcyl SM200/MS200,solar,164,thermaldisinfect,thermal disinfection,boolean, ,true,switch.solar_thermal_disinfection,switch.solar_thermaldisinfect @@ -4001,6 +4318,18 @@ WM10,switch,71,activated,activated,boolean, ,false,binary_sensor.switch_activate WM10,switch,71,flowtemphc,flow temperature (TC1),ushort (>=0<=3199),C,false,sensor.switch_flow_temperature_(TC1),sensor.switch_flowtemphc WM10,switch,71,status,status,int (>=-126<=126), ,false,sensor.switch_status,sensor.switch_status Rego 3000,controller,240,datetime,date/time,string, ,false,sensor.controller_date/time,sensor.controller_datetime +EM10,alert,74,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.alert_set_flow_temperature,sensor.alert_setflowtemp +EM10,alert,74,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.alert_burner_set_power,sensor.alert_setburnpow +EM10/EM100,extension,243,flowtempvf,flow temperature in header (T0/Vf),short (>=-3199<=3199),C,false,sensor.extension_flow_temperature_in_header_(T0/Vf),sensor.extension_flowtempvf +EM10/EM100,extension,243,input,input,uint (>=0<=25),V,false,sensor.extension_input,sensor.extension_input +EM10/EM100,extension,243,outpow,output IO1,uint (>=0<=100),%,false,sensor.extension_output_IO1,sensor.extension_outpow +EM10/EM100,extension,243,setpower,request power,uint (>=0<=100),%,false,sensor.extension_request_power,sensor.extension_setpower +EM10/EM100,extension,243,setpoint,set temp.,uint (>=0<=254),C,false,sensor.extension_set_temp.,sensor.extension_setpoint +EM10/EM100,extension,243,minv,min volt.,uint (>=0<=25),V,true,number.extension_min_volt.,number.extension_minv +EM10/EM100,extension,243,maxv,max volt.,uint (>=0<=25),V,true,number.extension_max_volt.,number.extension_maxv +EM10/EM100,extension,243,mint,min temp.,uint (>=0<=254),C,true,number.extension_min_temp.,number.extension_mint +EM10/EM100,extension,243,maxt,max temp.,uint (>=0<=254),C,true,number.extension_max_temp.,number.extension_maxt +EM10/EM100,extension,243,mode,mode,uint (>=0<=254), ,false,sensor.extension_mode,sensor.extension_mode Logavent HRV176,ventilation,231,outfresh,outdoor fresh air,short (>=-3199<=3199),C,false,sensor.ventilation_outdoor_fresh_air,sensor.ventilation_outfresh Logavent HRV176,ventilation,231,infresh,indoor fresh air,short (>=-3199<=3199),C,false,sensor.ventilation_indoor_fresh_air,sensor.ventilation_infresh Logavent HRV176,ventilation,231,outexhaust,outdoor exhaust air,short (>=-3199<=3199),C,false,sensor.ventilation_outdoor_exhaust_air,sensor.ventilation_outexhaust @@ -4009,3 +4338,4 @@ Logavent HRV176,ventilation,231,ventinspeed,in blower speed,uint (>=0<=100),%,fa Logavent HRV176,ventilation,231,ventoutspeed,out blower speed,uint (>=0<=100),%,false,sensor.ventilation_out_blower_speed,sensor.ventilation_ventoutspeed Logavent HRV176,ventilation,231,ventmode,ventilation mode,enum [auto\|off\|L1\|L2\|L3\|L4\|demand\|sleep\|intense\|bypass\|party\|fireplace], ,true,select.ventilation_ventilation_mode,select.ventilation_ventmode Logavent HRV176,ventilation,231,airquality,air quality (voc),ushort (>=0<=31999), ,false,sensor.ventilation_air_quality_(voc),sensor.ventilation_airquality +Logavent HRV176,ventilation,231,airhumidity,relative air humidity,uint (>=0<=100),%,false,sensor.ventilation_relative_air_humidity,sensor.ventilation_airhumidity diff --git a/interface/package.json b/interface/package.json index b0d378263..c84bd3b09 100644 --- a/interface/package.json +++ b/interface/package.json @@ -27,13 +27,13 @@ "@mui/icons-material": "^5.14.18", "@mui/material": "^5.14.18", "@table-library/react-table-library": "4.1.7", - "@types/imagemin": "^8.0.4", + "@types/imagemin": "^8.0.5", "@types/lodash-es": "^4.17.11", - "@types/node": "^20.9.2", - "@types/react": "^18.2.37", - "@types/react-dom": "^18.2.15", + "@types/node": "^20.9.3", + "@types/react": "^18.2.38", + "@types/react-dom": "^18.2.16", "@types/react-router-dom": "^5.3.3", - "alova": "^2.13.1", + "alova": "^2.13.2", "async-validator": "^4.2.5", "history": "^5.3.0", "jwt-decode": "^4.0.0", @@ -47,13 +47,13 @@ "react-toastify": "^9.1.3", "sockette": "^2.0.6", "typesafe-i18n": "^5.26.2", - "typescript": "^5.2.2" + "typescript": "^5.3.2" }, "devDependencies": { "@preact/compat": "^17.1.2", "@preact/preset-vite": "^2.7.0", - "@typescript-eslint/eslint-plugin": "^6.11.0", - "@typescript-eslint/parser": "^6.11.0", + "@typescript-eslint/eslint-plugin": "^6.12.0", + "@typescript-eslint/parser": "^6.12.0", "concurrently": "^8.2.2", "eslint": "^8.54.0", "eslint-config-airbnb": "^19.0.4", diff --git a/interface/yarn.lock b/interface/yarn.lock index e980015d4..a0447cd7b 100644 --- a/interface/yarn.lock +++ b/interface/yarn.lock @@ -1414,12 +1414,12 @@ __metadata: languageName: node linkType: hard -"@types/imagemin@npm:^8.0.4": - version: 8.0.4 - resolution: "@types/imagemin@npm:8.0.4" +"@types/imagemin@npm:^8.0.5": + version: 8.0.5 + resolution: "@types/imagemin@npm:8.0.5" dependencies: "@types/node": "npm:*" - checksum: 29c490a18aced93634d9e0b7cb240041cb540bd0bc596c23af4e05be0a3db0681508599a8b6863b025cf91b0a6ca948496bebe041fcd8e90424594f1c562ca9b + checksum: 7d492a0953b932546ff952370f21f62067a2311809f6e6c23288745e6e7ec70e2dad443a455e4ab1b63e6e8d9780cbe4dfc3f3519a6e78d6812b55dc642706ac languageName: node linkType: hard @@ -1478,12 +1478,12 @@ __metadata: languageName: node linkType: hard -"@types/node@npm:^20.9.2": - version: 20.9.2 - resolution: "@types/node@npm:20.9.2" +"@types/node@npm:^20.9.3": + version: 20.9.3 + resolution: "@types/node@npm:20.9.3" dependencies: undici-types: "npm:~5.26.4" - checksum: 8bab2870bfc02efc988c53dfb0149634f8feb824132cc7f20b36f3d55d89ef893e3a43d545524a5cb3a284f4ce68ae4181d75a4a39cee6b79c586d719e6b7461 + checksum: 5d2a3a6b2b900814eab8c5093dabb7aa10895928719ec0074b9ac5584bcc83f5b680e2d2cb6c8b9751511b7b1b7fdd8586d2fc827b156f0263fdb65c4741bdef languageName: node linkType: hard @@ -1508,12 +1508,12 @@ __metadata: languageName: node linkType: hard -"@types/react-dom@npm:^18.2.15": - version: 18.2.15 - resolution: "@types/react-dom@npm:18.2.15" +"@types/react-dom@npm:^18.2.16": + version: 18.2.16 + resolution: "@types/react-dom@npm:18.2.16" dependencies: "@types/react": "npm:*" - checksum: 57ea7e9e210d95fa18fde82fc585cb6252c9118c8793a38b37b07ccbba05d09d14f88cf76af46eecda41c430b4400f789a4bbc505eec459a15cbaf13f56f887a + checksum: c0be61864a9f50bb8cd29c719d170b03b36149f4fbe308faa40194d15492c4a13814a2f344fc5ceb99b4747bfa11cdfb2d15a141ed37218a32ec0edf98b90f2b languageName: node linkType: hard @@ -1558,14 +1558,14 @@ __metadata: languageName: node linkType: hard -"@types/react@npm:^18.2.37": - version: 18.2.37 - resolution: "@types/react@npm:18.2.37" +"@types/react@npm:^18.2.38": + version: 18.2.38 + resolution: "@types/react@npm:18.2.38" dependencies: "@types/prop-types": "npm:*" "@types/scheduler": "npm:*" csstype: "npm:^3.0.2" - checksum: fab3a5960e710aad6c16ffe57f48a470c6bbbe9e6363f70accf114191ea3192a204e33b5657324f14e64b2095986327db6b728fc15156e05f7d30b6dca0d66a3 + checksum: 9f9b9925c979e848d572dce6fff34951708127ba6b1fd4306c93fbcab74f5c6cff2b2e47d4222339eeb6c19d264e93450cb2ad6b255c73c536d0a1e2093cc98a languageName: node linkType: hard @@ -1601,15 +1601,15 @@ __metadata: languageName: node linkType: hard -"@typescript-eslint/eslint-plugin@npm:^6.11.0": - version: 6.11.0 - resolution: "@typescript-eslint/eslint-plugin@npm:6.11.0" +"@typescript-eslint/eslint-plugin@npm:^6.12.0": + version: 6.12.0 + resolution: "@typescript-eslint/eslint-plugin@npm:6.12.0" dependencies: "@eslint-community/regexpp": "npm:^4.5.1" - "@typescript-eslint/scope-manager": "npm:6.11.0" - "@typescript-eslint/type-utils": "npm:6.11.0" - "@typescript-eslint/utils": "npm:6.11.0" - "@typescript-eslint/visitor-keys": "npm:6.11.0" + "@typescript-eslint/scope-manager": "npm:6.12.0" + "@typescript-eslint/type-utils": "npm:6.12.0" + "@typescript-eslint/utils": "npm:6.12.0" + "@typescript-eslint/visitor-keys": "npm:6.12.0" debug: "npm:^4.3.4" graphemer: "npm:^1.4.0" ignore: "npm:^5.2.4" @@ -1622,44 +1622,44 @@ __metadata: peerDependenciesMeta: typescript: optional: true - checksum: c9c9e7a918e2f3ef8cb200c9158b70553a1014529867411b35e141c1d26713dd281907af1a231e640e8c4c73c3245a20cfc0e56a1cc95874889ce88c04706c78 + checksum: 1b9d2bb88f3e793067d7ec1e24e11b9d22891314bd5ebdef80a11a0ddde19f5c052b341e2f2c8a466b3af48e492f1028023566feaeb10a826d3928380c3d3d88 languageName: node linkType: hard -"@typescript-eslint/parser@npm:^6.11.0": - version: 6.11.0 - resolution: "@typescript-eslint/parser@npm:6.11.0" +"@typescript-eslint/parser@npm:^6.12.0": + version: 6.12.0 + resolution: "@typescript-eslint/parser@npm:6.12.0" dependencies: - "@typescript-eslint/scope-manager": "npm:6.11.0" - "@typescript-eslint/types": "npm:6.11.0" - "@typescript-eslint/typescript-estree": "npm:6.11.0" - "@typescript-eslint/visitor-keys": "npm:6.11.0" + "@typescript-eslint/scope-manager": "npm:6.12.0" + "@typescript-eslint/types": "npm:6.12.0" + "@typescript-eslint/typescript-estree": "npm:6.12.0" + "@typescript-eslint/visitor-keys": "npm:6.12.0" debug: "npm:^4.3.4" peerDependencies: eslint: ^7.0.0 || ^8.0.0 peerDependenciesMeta: typescript: optional: true - checksum: abb2aff0d4f06937337d1b2da77df4e1501d708b0bce1707c523206ee10e6aa732e1ae6548da56b9889459f23c375a6f0ae2e3a208e972dab8eb3b46680d839a + checksum: 2e33b581bcf882336bd4734e90a90dc3618960f8c07f5f7d16e4f3a0f00af97d3b3c8adc366170e1d9c8afd922068b3cfc5e9e997fd4ca6ebcb7c46a9e5b30a1 languageName: node linkType: hard -"@typescript-eslint/scope-manager@npm:6.11.0": - version: 6.11.0 - resolution: "@typescript-eslint/scope-manager@npm:6.11.0" +"@typescript-eslint/scope-manager@npm:6.12.0": + version: 6.12.0 + resolution: "@typescript-eslint/scope-manager@npm:6.12.0" dependencies: - "@typescript-eslint/types": "npm:6.11.0" - "@typescript-eslint/visitor-keys": "npm:6.11.0" - checksum: 60702ab23710c59ab0b52ffc66f77e24382cec8f684e3e43d4269cc17f414d3cb3a3bb85e232ea9f1e0f7e85506529978a5eea3c08945c01ed7aed4d4997b472 + "@typescript-eslint/types": "npm:6.12.0" + "@typescript-eslint/visitor-keys": "npm:6.12.0" + checksum: 46c4a5575fbbb70a800934c93e89795cceef268a140b786a8d22615a0577a5356e42e316dfb23dbb43cec7271b480e712e3127ba33642040bd292fbb6a5de278 languageName: node linkType: hard -"@typescript-eslint/type-utils@npm:6.11.0": - version: 6.11.0 - resolution: "@typescript-eslint/type-utils@npm:6.11.0" +"@typescript-eslint/type-utils@npm:6.12.0": + version: 6.12.0 + resolution: "@typescript-eslint/type-utils@npm:6.12.0" dependencies: - "@typescript-eslint/typescript-estree": "npm:6.11.0" - "@typescript-eslint/utils": "npm:6.11.0" + "@typescript-eslint/typescript-estree": "npm:6.12.0" + "@typescript-eslint/utils": "npm:6.12.0" debug: "npm:^4.3.4" ts-api-utils: "npm:^1.0.1" peerDependencies: @@ -1667,23 +1667,23 @@ __metadata: peerDependenciesMeta: typescript: optional: true - checksum: 478819bbbab39a0d11dc6276fc9b90e0b2576d7e32d761c811369657dc12bfaf95084bf951714ea82015259d736dec70770d229d6547b066ea0fc4133039082f + checksum: e92709a0ea5d5aee86def3da40fe4190235d3560f41e77a73d4bc10f6f59e0df367d5a1263d4e05aa44af4deb158ca6f37b09e483248e341a38fd5e2e8b70f72 languageName: node linkType: hard -"@typescript-eslint/types@npm:6.11.0": - version: 6.11.0 - resolution: "@typescript-eslint/types@npm:6.11.0" - checksum: 3ea55101325950d9594f839b38aa1c0958c3b8401ca9a8d2e4247997bb30dff7ac5e760e888de48a3ea9af3cb656eafb3e2cddc837a523a300ebccb63e150185 +"@typescript-eslint/types@npm:6.12.0": + version: 6.12.0 + resolution: "@typescript-eslint/types@npm:6.12.0" + checksum: e52f12d01e2f543927fde985d709616dec1ef310da3a00e3d239874752ba7635e04d325e2a7cf6403d19977282f15fed7629d2477aeeb57df9140fa424f530fe languageName: node linkType: hard -"@typescript-eslint/typescript-estree@npm:6.11.0": - version: 6.11.0 - resolution: "@typescript-eslint/typescript-estree@npm:6.11.0" +"@typescript-eslint/typescript-estree@npm:6.12.0": + version: 6.12.0 + resolution: "@typescript-eslint/typescript-estree@npm:6.12.0" dependencies: - "@typescript-eslint/types": "npm:6.11.0" - "@typescript-eslint/visitor-keys": "npm:6.11.0" + "@typescript-eslint/types": "npm:6.12.0" + "@typescript-eslint/visitor-keys": "npm:6.12.0" debug: "npm:^4.3.4" globby: "npm:^11.1.0" is-glob: "npm:^4.0.3" @@ -1692,34 +1692,34 @@ __metadata: peerDependenciesMeta: typescript: optional: true - checksum: 9d2333e517d50035f2c962b3966ebf8b35db0ac139c537cf4f1c4fd7b8d8914671671ad3bccdd59ef88fc4d29f441c0412a6c119ac6463bd2fbe8059d5209219 + checksum: 16f327faf736becb145894380e059a68a993b14fdf6dab50c5b79ff3c027a1e1a61274742f44f6ecd9ebbfadfc55559f94fad52e1596e1ed2656a3053367de85 languageName: node linkType: hard -"@typescript-eslint/utils@npm:6.11.0": - version: 6.11.0 - resolution: "@typescript-eslint/utils@npm:6.11.0" +"@typescript-eslint/utils@npm:6.12.0": + version: 6.12.0 + resolution: "@typescript-eslint/utils@npm:6.12.0" dependencies: "@eslint-community/eslint-utils": "npm:^4.4.0" "@types/json-schema": "npm:^7.0.12" "@types/semver": "npm:^7.5.0" - "@typescript-eslint/scope-manager": "npm:6.11.0" - "@typescript-eslint/types": "npm:6.11.0" - "@typescript-eslint/typescript-estree": "npm:6.11.0" + "@typescript-eslint/scope-manager": "npm:6.12.0" + "@typescript-eslint/types": "npm:6.12.0" + "@typescript-eslint/typescript-estree": "npm:6.12.0" semver: "npm:^7.5.4" peerDependencies: eslint: ^7.0.0 || ^8.0.0 - checksum: 7b8c17bd191b06cc77fe341f32fb7b4126d47a6ec05e5112567d4424a1896cf851935ff867c825d7e3361c317a48fe5304f95e454089f9aecc182bd42b1e4176 + checksum: 84091ddc0f0cceb5d0a2e366139d65413867cf648f805355ab4a42ee273cdd691b9083084d1c1feb9cb3c1934c1ed338fbf92146c738a96b84de3d2ec2dfdec5 languageName: node linkType: hard -"@typescript-eslint/visitor-keys@npm:6.11.0": - version: 6.11.0 - resolution: "@typescript-eslint/visitor-keys@npm:6.11.0" +"@typescript-eslint/visitor-keys@npm:6.12.0": + version: 6.12.0 + resolution: "@typescript-eslint/visitor-keys@npm:6.12.0" dependencies: - "@typescript-eslint/types": "npm:6.11.0" + "@typescript-eslint/types": "npm:6.12.0" eslint-visitor-keys: "npm:^3.4.1" - checksum: d89ef8579737f23a1a81506724e2c5cfec92fa4431232f93c4b6970a21382c6c0ad09ba21ffe8d25725d43aecce351fee2797c9170012ef0c00e5be7592e8233 + checksum: edf3537c8176059e8fdea680c10f85a635e427fb5caa6f88473077f50edbec7b011b0dc1e4499543519085559268d30a166b1cb160d30a1315ef818fc181a6a4 languageName: node linkType: hard @@ -1743,15 +1743,15 @@ __metadata: "@preact/compat": "npm:^17.1.2" "@preact/preset-vite": "npm:^2.7.0" "@table-library/react-table-library": "npm:4.1.7" - "@types/imagemin": "npm:^8.0.4" + "@types/imagemin": "npm:^8.0.5" "@types/lodash-es": "npm:^4.17.11" - "@types/node": "npm:^20.9.2" - "@types/react": "npm:^18.2.37" - "@types/react-dom": "npm:^18.2.15" + "@types/node": "npm:^20.9.3" + "@types/react": "npm:^18.2.38" + "@types/react-dom": "npm:^18.2.16" "@types/react-router-dom": "npm:^5.3.3" - "@typescript-eslint/eslint-plugin": "npm:^6.11.0" - "@typescript-eslint/parser": "npm:^6.11.0" - alova: "npm:^2.13.1" + "@typescript-eslint/eslint-plugin": "npm:^6.12.0" + "@typescript-eslint/parser": "npm:^6.12.0" + alova: "npm:^2.13.2" async-validator: "npm:^4.2.5" concurrently: "npm:^8.2.2" eslint: "npm:^8.54.0" @@ -1781,7 +1781,7 @@ __metadata: sockette: "npm:^2.0.6" terser: "npm:^5.24.0" typesafe-i18n: "npm:^5.26.2" - typescript: "npm:^5.2.2" + typescript: "npm:^5.3.2" vite: "npm:^5.0.0" vite-plugin-imagemin: "npm:^0.6.1" vite-tsconfig-paths: "npm:^4.2.1" @@ -1853,10 +1853,10 @@ __metadata: languageName: node linkType: hard -"alova@npm:^2.13.1": - version: 2.13.1 - resolution: "alova@npm:2.13.1" - checksum: f0ef3ac891aa26d4cc125b8e601f8efac2517109ecfb75598e6ecb0872fb8e0c62d1dfc633b7920e6f57deaec377489e828960968c4534b6ab7f69ff7e29af6e +"alova@npm:^2.13.2": + version: 2.13.2 + resolution: "alova@npm:2.13.2" + checksum: 09d3949b20094833ae9a2861b7408b6697e2e7fa677d6bbb31a7c43a756bef1033a999a9aa94aff94f392eb5186f9ae2e63a381560fd42c59987948740f6a043 languageName: node linkType: hard @@ -8362,23 +8362,23 @@ __metadata: languageName: node linkType: hard -"typescript@npm:^5.2.2": - version: 5.2.2 - resolution: "typescript@npm:5.2.2" +"typescript@npm:^5.3.2": + version: 5.3.2 + resolution: "typescript@npm:5.3.2" bin: tsc: bin/tsc tsserver: bin/tsserver - checksum: d65e50eb849bd21ff8677e5b9447f9c6e74777e346afd67754934264dcbf4bd59e7d2473f6062d9a015d66bd573311166357e3eb07fea0b52859cf9bb2b58555 + checksum: 415e5fb6611f5713e460bad48039f00bcfdbde53a2f911727862d5aa9c5d5edd250059a419df382d8f031709e15a169c41eb62b6a401da5eec7ac0f4e359d6ac languageName: node linkType: hard -"typescript@patch:typescript@npm%3A^5.2.2#optional!builtin": - version: 5.2.2 - resolution: "typescript@patch:typescript@npm%3A5.2.2#optional!builtin::version=5.2.2&hash=f3b441" +"typescript@patch:typescript@npm%3A^5.3.2#optional!builtin": + version: 5.3.2 + resolution: "typescript@patch:typescript@npm%3A5.3.2#optional!builtin::version=5.3.2&hash=e012d7" bin: tsc: bin/tsc tsserver: bin/tsserver - checksum: f79cc2ba802c94c2b78dbb00d767a10adb67368ae764709737dc277273ec148aa4558033a03ce901406b35fddf4eac46dabc94a1e1d12d2587e2b9cfe5707b4a + checksum: 1b45cdfb577a78ae7a9a9d0b77a7b772142cb98ba05e4e5aefba7044a028ded885bcecef63166407a5986645cea816fe4986894336aacd5e791796ea79a6a7ed languageName: node linkType: hard diff --git a/src/version.h b/src/version.h index 29351a9ae..b7afb6a19 100644 --- a/src/version.h +++ b/src/version.h @@ -1 +1 @@ -#define EMSESP_APP_VERSION "3.6.4-dev.0" +#define EMSESP_APP_VERSION "3.6.4-dev.1"