Hi folks
On my Altherma I use the rotex definition and I met two problems as follows.
First, I do not have the flow sensor reading so I use a constant number for that.
Secondly, as it does differ a bit from the example sensor for home assistant I altered the COP calculation.
I tried multiple solutions, that either seemed logic or found on the internet, like: R2/R4 or R1/R3 if I am not mistaken.
Question is, what do you think would be the best for these sensors:
with this data:
{ "EV (pls)": 256, "Outdoor Fan (Upper)(rps)": 0, "Outdoor Fan (Lower)(rps)": 0, "INV Comp. Frequency(Hz)": "OFF", "Comp. Preheat": "OFF", "52C Output": "OFF", "20R (SV) Output": "OFF", "20S (4-way) Output": "OFF", "Crankcase Heater": "OFF", "Ener-Cut Output": "OFF", "Indoor Suction Air Temp.(C)": 35.1719, "Indoor Heat Exchanger Temp.(C)": 34.625, "Outdoor air temp.(C)": 41.4844, "Outdoor heat exchanger temp.(C)": 36.0156, "Discharge pipe temp.(C)": 66.5, "Fin Temp.(C)": 0.00390625, "Delta-Tr(deg)": 0.625, "R/C Setpoint(C)": 0, "Operation Mode": "Heating", "Error Code": " 0", "Thermo Off Error": " 0", "Warning Code": " 0", "Caution Code": " 0", "WifiRSSI": "-56dBm", "FreeMem": "229604" }
and this is the current sensor:
- platform: template sensors: espaltherma_cop: friendly_name: "ESPAltherma COP" unique_id: "espaltherma_cop" unit_of_measurement: 'COP' # flow rate = kg/hour # (flow l per min*0.06*1.16) * (R2T-R4T) / (Amp * V / 1000) value_template: "{% if is_state_attr('sensor.althermasensors', 'Operation Mode', 'Heating') %} {{ (((28 * 0.06 * 1.16) * (state_attr('sensor.althermasensors', 'Discharge pipe temp.(C)') | float - state_attr('sensor.althermasensors', 'Outdoor heat exchanger temp.(C)')|float) ) / (states.sensor.sonoff_100147b385_current.state | float * states.sensor.sonoff_100147b385_voltage.state|float / 1000)) |round(2) }} {% else %} 0 {%endif%}"[core-ssh ~]$
The text was updated successfully, but these errors were encountered:
No branches or pull requests
Hi folks
On my Altherma I use the rotex definition and I met two problems as follows.
First, I do not have the flow sensor reading so I use a constant number for that.
Secondly, as it does differ a bit from the example sensor for home assistant I altered the COP calculation.
I tried multiple solutions, that either seemed logic or found on the internet, like:
R2/R4 or R1/R3 if I am not mistaken.
Question is, what do you think would be the best for these sensors:
with this data:
{ "EV (pls)": 256, "Outdoor Fan (Upper)(rps)": 0, "Outdoor Fan (Lower)(rps)": 0, "INV Comp. Frequency(Hz)": "OFF", "Comp. Preheat": "OFF", "52C Output": "OFF", "20R (SV) Output": "OFF", "20S (4-way) Output": "OFF", "Crankcase Heater": "OFF", "Ener-Cut Output": "OFF", "Indoor Suction Air Temp.(C)": 35.1719, "Indoor Heat Exchanger Temp.(C)": 34.625, "Outdoor air temp.(C)": 41.4844, "Outdoor heat exchanger temp.(C)": 36.0156, "Discharge pipe temp.(C)": 66.5, "Fin Temp.(C)": 0.00390625, "Delta-Tr(deg)": 0.625, "R/C Setpoint(C)": 0, "Operation Mode": "Heating", "Error Code": " 0", "Thermo Off Error": " 0", "Warning Code": " 0", "Caution Code": " 0", "WifiRSSI": "-56dBm", "FreeMem": "229604" }
and this is the current sensor:
- platform: template sensors: espaltherma_cop: friendly_name: "ESPAltherma COP" unique_id: "espaltherma_cop" unit_of_measurement: 'COP' # flow rate = kg/hour # (flow l per min*0.06*1.16) * (R2T-R4T) / (Amp * V / 1000) value_template: "{% if is_state_attr('sensor.althermasensors', 'Operation Mode', 'Heating') %} {{ (((28 * 0.06 * 1.16) * (state_attr('sensor.althermasensors', 'Discharge pipe temp.(C)') | float - state_attr('sensor.althermasensors', 'Outdoor heat exchanger temp.(C)')|float) ) / (states.sensor.sonoff_100147b385_current.state | float * states.sensor.sonoff_100147b385_voltage.state|float / 1000)) |round(2) }} {% else %} 0 {%endif%}"[core-ssh ~]$