* HX710B library for Arduino with MPS20N0040D pressure sensor support
* https://github.com/kurimawxx00/hx710B_pressure_sensor
*
* Based on HX711 library by https://github.com/bogde/
*
* MIT License
* (c) 2021 Roland Pelayo
*
**/
#ifndef HX710B_h
#define HX710B_h
#if ARDUINO >= 100
#include "Arduino.h"
#else
#include "WProgram.h"
#endif
class HX710B
{
private:
byte PD_SCK; // Power Down and Serial Clock Input Pin
byte DOUT; // Serial Data Output Pin
byte GAIN;
long READ_TIMES = 10;
long OFFSET = -540000;; // used for tare weight
float SCALE = 1; // used to return weight in grams, kg, ounces, whatever
float RES = 2.98023e-7;
public:
HX710B();
virtual ~HX710B();
// Initialize library with data output pin, clock input pin and gain factor.
// Channel selection is made by passing the appropriate gain:
// - With a gain factor of 64 or 128, channel A is selected
// - With a gain factor of 32, channel B is selected
// The library default is "128" (Channel A).
void begin(byte dout, byte pd_sck, byte gain);
void setGain(byte gain);
// Check if HX710B is ready
// from the datasheet: When output data is not ready for retrieval, digital output pin DOUT is high. Serial clock
// input PD_SCK should be low. When DOUT goes to low, it indicates data is ready for retrieval.
bool is_ready();
// Wait for the HX710B to become ready
void wait_ready(unsigned long delay_ms = 0);
bool wait_ready_retry(int retries = 3, unsigned long delay_ms = 0);
bool wait_ready_timeout(unsigned long timeout = 1000, unsigned long delay_ms = 0);
// waits for the chip to be ready and returns a reading
long read();
// returns an average reading; times = how many times to read
long read_average(byte times = 10);
// returns pressure in kilopascals
float pascal();
//returns pressure in atm
float atm();
//returns pressure in mmHg
float mmHg();
//returns pressure in psi
float psi();
// returns (read_average() - OFFSET), that is the current value without the tare weight; times = how many readings to do
double get_value(byte times = 1);
// returns get_value() divided by SCALE, that is the raw value divided by a value obtained via calibration
// times = how many readings to do
float get_units(byte times = 1);
// set the OFFSET value for tare weight; times = how many times to read the tare value
void tare(byte times = 10);
// set the SCALE value; this value is used to convert the raw data to "human readable" data (measure units)
void set_scale(float scale = 1.f);
// get the current SCALE
float get_scale();
// set OFFSET, the value that's subtracted from the actual reading (tare weight)
void set_offset(long offset = 0);
// get the current OFFSET
long get_offset();
// puts the chip into power down mode
void power_down();
// wakes up the chip after power down mode
void power_up();
};
#endif /* HX710B_h */