after updating my Fox H3-6.0 to firmware
Master 1.69
Slave 1.02
Manager: 1.59
the RS485 device id inside the inverter had the number 000. So the sensors did not work anymore.
I'm not sure if this is just me or a general problem.
After setting the device ID in the inverter to 247, the sensors worked again.
Would this be something for a wiki page?
Have others made such an experience after an firmware update?
The text was updated successfully, but these errors were encountered:
Hi,
after updating my Fox H3-6.0 to firmware
Master 1.69
Slave 1.02
Manager: 1.59
the RS485 device id inside the inverter had the number 000. So the sensors did not work anymore.
I'm not sure if this is just me or a general problem.
After setting the device ID in the inverter to 247, the sensors worked again.
Would this be something for a wiki page?
Have others made such an experience after an firmware update?