You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Hi, as I said, I was fully able to use pycomm 1.0.8 to read from my MicroLogix1100 on a 3.6.7 Python, but when I tried to deploy/reply into an Windows AWS with same py/libs versions it just doesn't work.
Btw, another thing that I tried is change to a wrong/non-plc ip, and it runs the normal timeout error.
What is the relation about OS? Cause I got a similar error on Linux Suse12 as well... There is any incompatibility about how I code the IP Address or something?
Code:
from pycomm.ab_comm.slc import Driver as SlcDriver
import logging
plc = SlcDriver()
ip = '10.11.12.123'
plc.open(ip)
strr = str(plc.read_tag("N7:0/1"))
plc.close()
print(strr)
Error:
---------------------------------------------------------------------------
TypeError Traceback (most recent call last)
d:\anaconda3\envs\pycaml8\lib\site-packages\pycomm\cip\cip_base.py in build_header(self, command, length)
616 h = command # Command UINT
--> 617 h += pack_uint(length) # Length UINT
618 h += pack_dint(self._session) # Session Handle UDINT
TypeError: must be str, not bytes
During handling of the above exception, another exception occurred:
CommError Traceback (most recent call last)
d:\anaconda3\envs\pycaml8\lib\site-packages\pycomm\cip\cip_base.py in open(self, ip_address)
785 self.attribs['ip address'] = ip_address
--> 786 if self.register_session() is None:
787 self._status = (13, "Session not registered")
d:\anaconda3\envs\pycaml8\lib\site-packages\pycomm\cip\cip_base.py in register_session(self)
634 self._session = 0
--> 635 self._message = self.build_header(ENCAPSULATION_COMMAND['register_session'], 4)
636 self._message += pack_uint(self.attribs['protocol version'])
d:\anaconda3\envs\pycaml8\lib\site-packages\pycomm\cip\cip_base.py in build_header(self, command, length)
623 except Exception as e:
--> 624 raise CommError(e)
625
CommError: must be str, not bytes
During handling of the above exception, another exception occurred:
CommError Traceback (most recent call last)
<ipython-input-1-49a9409fe35c> in <module>
218 flag = True
219 while(flag):
--> 220 plc.open("10.11.12.123")
221 string = plc.read_tag("N7:0/1")
222 plc.close()
d:\anaconda3\envs\pycaml8\lib\site-packages\pycomm\cip\cip_base.py in open(self, ip_address)
791 except Exception as e:
792 #self.clean_up()
--> 793 raise CommError(e)
794
795 def close(self):
CommError: must be str, not bytes
The text was updated successfully, but these errors were encountered:
Hi, as I said, I was fully able to use pycomm 1.0.8 to read from my MicroLogix1100 on a 3.6.7 Python, but when I tried to deploy/reply into an Windows AWS with same py/libs versions it just doesn't work.
Btw, another thing that I tried is change to a wrong/non-plc ip, and it runs the normal timeout error.
What is the relation about OS? Cause I got a similar error on Linux Suse12 as well... There is any incompatibility about how I code the IP Address or something?
Code:
Error:
The text was updated successfully, but these errors were encountered: