Temperature not reflect accurately in graph; not coming back down #496

Open
andrewschafer opened this issue Nov 19, 2024 · 3 comments
Open

Comments

@andrewschafer
Copy link

There is a bug in the temperature graph. See the attached picture where the graph is stuck at ~69 deg, but the actual ASIC is at 63.5 deg.

I noticed because my BitAxe is on my garage workbench and the point where the graph goes up is when a heated car pulled up next to it (around 5 pm). As the car cooled, the ASIC temp came down, but the graph did not reflect that. I opened the garage door to let cold air in, which also reduced the ASIC more, but had no affect on the graph.

Temp Graph

Refreshing the dashboard in the browser fixed the issue with the graph.

@skot
Copy link
Owner

skot commented Nov 20, 2024

Interesting, I'm not seeing this on mine, but it looks like you have a lot of datapoints! I wonder if that's causing the problem.

@skot
Copy link
Owner

skot commented Nov 22, 2024

I got a bunch of datapoints on the graph last night. seems to be moving up and down ok. Although they are somewhat out of sync, and definitely not to the same precision
image

@WantClue
Copy link
Collaborator

Might be good if you could double check that again?
I also tested it on my devices and the temp chart does come down indeed.